ML20063A044

From kanterella
Jump to navigation Jump to search
Forwards Reactor Containment Integrated Leakage Rate Test Results Rept 1982, Summarizing Performance of Type a & 1980 & 1982 Type B & Type C Local Leak Rate Test Results
ML20063A044
Person / Time
Site: Beaver Valley
Issue date: 08/19/1982
From: Williams H
DUQUESNE LIGHT CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20063A046 List:
References
ND1SS1:621, NUDOCS 8208240167
Download: ML20063A044 (1)


Text

e

^

g5Q,

'A@

Telephone (412) 4564000 Nuclear Division P.O. Box 4 Shippingport, PA 15077-0004 August 19, 1982 NDISSl:621 Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 1982 Reactor Containment Integrated Leak Rate Test Report United States Nuclear Regulatory Commission Director of Nuclear Reactor Regulation Washington, D. C.

20555 Centlemen:

As per the requirements of Title 10 Code of Federal Regulations, Part 50, Appendix J,Section V. B.

1, attached is the BVPS Unit No. 1 Reactor Containment Integrated Leak Rate Test Report. This report summarizes the results for the 1982 performance of the Type A ILRT, and the 1980 and 1982 Type B and Type C local Leak Rate Test results.

Very truly yours, ibf n

H. P. Williams Superintendent md Attachement cc:

Mr. W. R. Troskowski, Region I 820 8 24 0 l(o] k