ML20062N747

From kanterella
Jump to navigation Jump to search
Monthly Operating Repts for Dec 1993 for Brown Ferry Nuclear Plant,Units 1,2 & 3
ML20062N747
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 12/31/1993
From: Salas P, Tanya Smith
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9401210046
Download: ML20062N747 (13)


Text

,...

.f i

i 0-

)

r i

Tennesfee Vaiiey Auttmty Port Off>ce th 2OOO.Decats Alariama 3%c9 JAN 111994 U.S. Nuclear Regulatory Commission

{

ATTN:

Document Control Desk i

Washington, D.C.

20555 i

Gentlemen:

In the Matter Of

)

Docket Nos.'50-259 Tennessee Valley Authority

)

50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN) - MONTHLY OPERATING = REPORT.

FOR THE MONTH OF DECEMBER 1993 l

In accordance-with the requirements of BFN Units 1,.2,:and 3 Technical Specifications Section 6.9.1.3, TVA is submitting the Monthly Operating Report for the month of December 1993 in the enclosure.

t If you have any questions, please telephone me at l

(205) 729-2636.

1 1

Sincere I

m Pedro Salas i

Manager'of Site Licensing

Enclosure:

i 3

cc: :See page 2 t

j

'i

-l 9401210046 931231

. gDR-:. ; ADOCK105000257 -

I

-16 AY

' '~

PDR llg

1 O.S. Nuclear Regulatory-Commission Page 2 JAH 1 1 h84 Enclosure cc (Enclosure):

Project _ Chief Mr.

R. V.

Crlenjak, U.S.

Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 t

Mr. Frederick J. Hebdon, Director Project Directorate II-4 Division of Reactor Projects I-II Office of Nuclear Reactor Regulation, Mail-13 H3 Washington, D.C.

20555 INPO Records Center Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30389 Mr. Ted Martson, Director Electric Power Research Institute P.

O.

Box 10412 Palo Alto, California 94304 NRC Resident Inspector Browns Ferry Nuclear Plant Route 12, Box 637 Athens, Alabama 35611 i

Regional Administrator U.S.

Nuclear Regulatory Commission Region II 101 Marietta Street,-NW, Suite 2900 i

Atlanta, Georgia 30323

{

Mr. Fred Yost, Director of Research Services, Utility Data Institute, Inc.

1700 K Street, NW, Suite 400 Washington, D.C.

20006 9

I

=_

ENCLOSURE MONTHLY OPERATING REPORT BROWNS FERRY NUCLEAR PLANT TENNESSEE VALLEY AUTHORITY DECEMBER 1993 DOCKET NUMBERS 50-259, 50-260, AND 50-296 LICENSE NUMBERS DPR-33, DPR-52, AND DPR-68 I

l t-a Y

d

OPERATIONAL

SUMMARY

i DECEMBER 1993 t

BROWNS FERRY 1 L

Unit i remains on administrative-hold to resolve various TVA~and NRC concerns.

Unit I has been on administrative hold since June 1,

1985.

As a result, TVA considers that accrual of reporting hours is suspended since the unit has a maximum dependable capacity of 0 MWe.

Accordingly, TVA does not consider cumulative reporting period hours for the period beginning June 1,

1985, when calculating the operating status variables.

BROWNS FERRY 2 Unit 2 operated continuously during the month of December at a capacity factor of 102.4 percent and generated 830,240 megawatt hours gross electrical power.

As of December 31, 1993, Unit 2 has operated continuously for 211 days since returning to service in early June 1993 following the Cycle 6 refueling out, age.

i BROWNS FERRY 3

' Unit 3 remains on administrative hold to resolve various TVA and l

NRC concerns.

Unit 3 has been on administrative hold since June 1,

1985.

As a result, TVA considers that accrual of reporting hours is suspended since the unit has a maximum dependable.

capacity of 0 MWe.

Accordingly, TVA does not consider cumulative-reporting period hours for the period beginning June 1,

1985, when calculating the operating status _ variables.

l E

I f

i s

AVERAGE DAILY UNIT POWER LEVEL i

DOCKET No:

50-259 UNIT:

BROWNS FERRY 1 PREPARED BY T.

R.

Smith j

TELEPHONE:

(205) 729-2955-l t

MONTH December 1993 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL

+

(HWe-Net)

(MWe-Net) f 1

0 17 0

't 2

0 18 0

3 0

19 0

4 0

20 0

I r

.s 5

0 21 O

t t

6 0

22 0

7 0

23 0

8 0

24 0

l 9

0 25 0

3

i 10 0

26 0

11 0

27 0

12 0

28 0

13 0

29 0

l 14 0

30 0

)

i 15.

0 31 0

I

.l 16 0

i

.b

l i

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO: ~50-260 UNIT:

BROWNS FERRY 2

'f PREPARED BY:

T.

R.

Smith TELEPHONE:- f2051 729-2955 d

MONTH December 1993 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY' POWER LEVEL l

(MWe-Net)

'(MWe-Net) 1 1092 17 1092 2

1090 18 1084 1

i 3

10' 19 1098 i

4 1931 20 1085 i

5 1090 21 1092

'i t

6 1094 22 1093 r

I 7

1091 23 1091 8

1090 24 1088 9

1090 25 1085 l

10 1092 26 1095 j

11 1085 27 1093 l

12 1091 28 3090 13 1093 29 1091 14 1089 30 1091 I

15 1092 31 1093 16 1089

f i

?

i l

i

~.

.~.

AVERAGE DAILY UNIT POWER LEVEL i

DOCKET NO:

50-296

'{

IINIT: BROWNS FERRY 3 PREPARED BY:

T.

R.

Smith TELEPHONE: 1205) 729-2955 I

MONTH December 1993 i

DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) i l

1 0

17 0

2 0

18 0

3 0

19 0

i 4

0 20 0

5 0

21 0

'I 6

0 22 0

7 O

23 0

i' 8

0 24 0

f 9

0 25 0

10 0

26 0

i 11 0

27 0

.l 12 0

28 0

i 13 0

29 0

i 14 0

30 0

i

}

15 0

31 0

16 0

l

[

l e

DCCKET 8to: 50-259 UNIT SHUTDOWNS AND POWER REDUCTIONS UNIT: BRouMS FERRY 1 PREPARED BY:

T. R. Smith REPORT MONTH:

Dece h r 1993 TELEPHONE: (205) 729-2955 Method of License cause ord Corrective Duration Shutting Event System Copponent Action to Prevent No.

Date Type' (Hours)

Reason Down Reactor Eeport No.

Code

  • Code' Recurrence 2

8 1

06/01/85 S

?44 F

4 Adninistrative hold to resolve various TVA and NRC concerns.

'F: Forced

' Reason:

' Method:

~' Exhibit G-Instructions S: Scheduled A-Equipment Failure (Explain)'

1-Manual for Preparation of Data

-B-Maintenance or Test 2%vual Scram Entry sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File D-Regulatory Restriction 4-Cor tinuation of Existing Outege (NUREG-061)

E-Operator Training and License Examination 5-Recluction F-Achinistrat ive 9-Other G-Operational Error (Explain)

  • Exhibit I Same Source

.H-Other (Explain)

.__.;..~.___.. -.

DOCKET Wo: 50 200 U4tf SMUTDOWNS ACD POWER CEDUCTIONS CIT CROW 3 FERQ7 2 PREPARED BY:

T. R. Smith REPORT MONTH:

Deced =r 1993 TELEPHONE: -(205) 729-2955 Method of License Cause end Corrective Duration Shutting

. Event System comonent Action to Prevent No.

Date Type' (Mours)

Reason' Down Reactor' Report No.

Code' Code' Recurrence N/A

'F:. Forced

' Reason:

hthod:

  • Exhibit G-Instructions 5: Scheduled A-Equipment Falture (Explain) 1-Manual for Preparation of Data B Maintenance or Test-2-Manual Scram Entry sheets for L!ciensee C-Refueling 3-Automatic Scram Event Report (LER) File D-Regulatory Restriction 4-Continuation of Existing Dat e '

(NUREG-061)

E-Operator Training and License Examination 5-Reduction F-Adninist rative 9-Other G-Operational Error (Explain).

' Exhibit I-Same Source H-Other (Emplain)

_., ~.,. _._ _.,__. _

_ _ _.. -, _. ~ ~.-.

. ~ _... _ _,.. _ -... _ _ - _ _ _ _. _ -_,

LOff SMUTDOWWS AND POWER REDUCTIONS UNII: BCKnMS FERRY 3_'

[~

DCCKET 50: 50+296

~

PREPARED BY:

T, R. Smith REPCRT w] NTH:

Dece @ r 1993 TELEPHokE: (205) 729-2955 Method of License Cause and Corrective Duration Shutting Event System Conponent Action to Prevent No.

Date Type' (Moors) acason' Down Reactor' Report No.

Code' Code' Recurrence 1

06/01/85 S

744 F

4 Adninistrative hold to resolve various TVA and NRC concerns.

J

'F: Forced

' Reason:

Method:

' Exhibit G-Instructions S Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram Entry sheets for Licensee C-Refueling "3-Automatic Scram Event Report (LER) File D-Regulatory Restriction 4-Continuation of Existing Outage (NUREG-061)

E-Operator Training and License Examination 5-Reduction

' F-Adninistrative 9-Other G-Operational Error (Explain)

' Exhibit I-Same Source H-Other.(Explain).

..-~-.

- _.~

~-... -., _

OPERATING DATA REPORT 4

DOCKET:

50-259 UNIT - BROWNS PERRY I PREPARED BY:

T.

R.

SMITH TELEPHONE:

(205) 729-29,11 OPERATING STATUS

1. Unit Names BROWNS FERRY UNIT 1
2. Reporting Period DECEMBER 1993 i
3. Licensed Thermal Power (MWt):

3293

4. Nameplate Rating (Gross MWe):

1152

5. Design Electrical Rating (Net MWe):

1065

6. Maximum Dependable capacity (Gross MWe): 0 l
7. Maximum Dependable Capacity (Net MWe):

0 8.

If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reason: N/A

9. Power Level To Which Restricted, If Any (Net MWe):

0

10. Reason For Restrictions, If Any: Administrative Hold I

THIS MONTH YEAR TO DATE CUMULATIVE

  • t
11. Hours in Reporting Period 0

0 95743

12. Hours Reactor Wa' Critical 0

0 59521 s

13. Reactor Reserve Shutdown Hours 0

0 6997

14. Hours Generator On Line 0

0

.58267

15. Unit Reserve Shutdown Hours 0

0 0

16. Gross Thermal Generation (MWh) 0 0

168066787 j

17. Gross Electrical Generation (MWh) 0 0

55398130

18. Net Electrical Generation (MWh) 0 0

53796427

19. Unit Service Factor 0

0 60.9 j

20. Unit Availability Factor 0

0 60.9-

21. Unit Capacity Factor (MDC Net) 0 0

52.8

22. Unit Capacity Factor (DER net) 0 0

52.8

23. Unit Forced Outage Rate 0

0 25.6

24. Shutdowns Scheduled Over Next 6 Monthe

'(Type, Date, and Duration of Each): N/A

25. If Shut Down At End Of Reporting Period, Estimated Date of Startup: To be determined i

Excludes hours under administrative hold (June 1, 1985 to present)

4 l

.~

OPERATING DATA REPORT l

t DOCKET:

50-260

+

UNIT:

BROWNS FERRY 2 s

PREPARED BY:

T.

R.

SMITH l'

TELEPHONE:

(205) 729-2955 OPERATING STATUS

1. Unit Names BROWNS FERRY UNIT 2
2. Reporting Period DECEMBER 1993
3. Licensed Thermal Power (MWt): 3293
4. Nameplate Rating (Gross MWe):

1152

5. Design Electrical Rating (Net MWe):

1065

6. Maximum Dependable capacity (Gross MWe):

1098.4

7. Maximum Dependable Capacity (Net MWe):

1065 l

8.

If Changes occur in capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reason: N/A

9. Power Lavel To Which Restricted, If Any (Net MWe): N/A
10. Reason For Restrictions, If Any:

N/A THIS MONTH YEAR TO DATE CUMULATIVE *

11. Hours in Reporting Period 744 8760 113311
12. Hours Reactor Was Critical 744 5854 74817
13. Reactor Reserve Shutdown Hours 0

0 14200

14. Hours Generator On Line 744 5754 72625 l
15. Unit Reserve Shutdown Hours 0

0 0

16. Cross Thermal Generation (MWh) 2445505 17818949 208547601
17. Gross Electrical Generation (MWh) 830240 5930270 69207918
18. Net Electrical Generation (MWh) 811267 5776842 67244662
19. Unit Service Factor 100.0 65.7 64.1
20. Unit Availability Factor 100.0 65.7 64.1 21.' Unit capacity Factor (MDC Net) 102.4 61.9 55.7
22. Unit capacity Factor (DER net) 102.4 61.9 55.7
23. Unit Forced Outage Rate 0

0 18.5 i

24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each): N/A

~

25. If Shut Down At End Of Reporting Period, Estimated Date of Startup N/A 1

l.i Excludes hours under administrative hold (June 1, 1985 to May 24, 1991)

i OPERATING DATA REPORT t

DOCKET:

50-296 UNIT:

BROWNS FERRY 3 PREPARED BY:

T.

R.

SMITH TELEPHONE:

(205) 729-2955 OPERATING STATUS

1. Unit Names BROWNS FERRY UNIT 3
2. Reporting Period DECEMBER 1993
3. Licensed Thermal Power (MWt): 3293
4. Nameplate Rating (Gross MWe):

1152

5. Design Electrical Rating (Net MWe):

1065

6. Maximum Dependable Capacity (Gross MWe):

0

7. Maximum Dependable Capacity (Net MWe):

0 8.

If Changas Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reason: N/A

9. Power Level To Which Restricted, If Any (Net MWe):

0

10. Reason For Restrictions, If Any Administrative Hold THIS MONTH YEAR TO DATE CLHULATIVE*
11. Hours in Reporting Period 0

0 73055

12. Hours Reactor Was Critical 0

0 45306

13. Reactor Reserve Shutdown Hours 0

0 5150

14. Hours Generator On Line 0

0 44195

15. Unit Reserve Shutdown Hours 0

0 0

16. Gross Thermal Generation (MWh) 0 0

131868267

17. Gross Electrical Generation (MWh) 0 0

43473760

18. Net Electrical Generation (MWh) 0 0

42114009

19. Unit Service Factor 0

0 60.5

20. Unit Availability Factor 0

0 60.5

21. Unit Capacity Factor (MDC Net) 0 0

54.2

22. Unit Capacity Factor (DER net) 0 0

54.2

23. Unit Forced Outage Rate 0

0 21.6

24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each): N/A
25. If Shut Down At End Of Reporting Period, Estimated Date of Startup: To be determined Excludes hours under administrative hold (June 1, 1985 to present)

,