BALTIMORE GAS AND ELECTRIC l

CHARLES CENTER P.O. BOX 1475 BALTIMORE, MARYLAND 21203 ARTHUR E. LUNDVALL, JR.

vice pacs.ocut S**v July 27,1982 U.S. Nuclear Regulatory Commission Docket Nos.

50-317 Region I 50-318 631 Park Avenue License Nos.

DPR-53 King of Prussia, PA 19406 DPR-69 ATTENTION:

T. T. Martin, Director Division of Engineering and Technical Programs Gentlemen:

This refers to your Inspection Report 50-317/81-17; 50-318/81-16, which transmitted one item of apparent noncompliance with NRC requirements. Enclosure (1) to this letter is a written statement in reply to that item noted in your letter of June 28,1982.

Should you have further questions regarding this reply, we will be pleased to discuss them with you.

Very truly yours,

,r

  • f _ &m" -

Vice President - Supply AEL/DWL/gla Enclosure cc:

3. A. Biddison, Esquire G. F. Trowbridge, Esquire -

D. H. Jaffe, NRC R. E. Architzel, NRC F208230323 820819 PDR ADOCK 05000317 O

PDR

Mr. T. T. Martin July 27,1982 Page 2 STATE OF MARYLAND TO WIT:

CITY OF BALTIMORE Arthur E. Lundvall, Jr., being duly sworn states that he is Vice President of the Baltimore Gas and Electric Company, a corporation of the State of Maryland; that he provides the foregoing response for the purposes therein set forth; that the statements made are true and correct to the best of his knowledge, information, and belief; and that he was authorized to provide the response on behalf of said C poration.

_ctd WITNESS my Hand and Notarial Seal:

/

Notary Public My Commission Expires:

f. // /[bb v

V 4

l l

[

i s

=.

a ENCLOSURE (1)

REPLY TO APPENDIX A OF NRC INSPECTION REPORT 50-317/81-17; 50-318/81-16 Effective August 26, 1981, the handling of Spent Radioactive Resins was addressed in Radiation Safety Procedure (RSP 2-204), " Packaging, l.abeling, and Shipment of Radioactive Material."

On April 7,1982,' a change to this procedure was made incorporating, " Resin Shipment Worksheets" as an aid in determining Specific Activities, Activity Concentrations, and Total. Activity. The worksheet is filled out with each shipment and includes information on quantities of ingredients used and weight of shipment. In addition, once per ten shipments, a sample of non-radioactive resins is processed using the same solidification ingredients to study such factors as set-up time, quality of ingredients, and possible residual water.

It is acknowledged that RSP 2-204 has not received POSRC review. All revisions to this procedure have been reviewed by the Plant Superintendent and all, changes to this procedure have received approval by the Radiation Safety Section Supervision and/or Staff. However, by August 13,1982, Calvert Cliffs Instruction (CCI)-805, "Calvert Cliffs Radiation Safety Procedure Format", will be changed to reflect the requirement for POSRC review.

RSP 2-204 will be upgraded to include sign-offs for the resin solidification process control procedure and the latest revision with incorporated changes will be submitted for POSRC review. Full compliance will be achieved by September 3, 1982.