..,f
\\
N ei%.er'i A u PART 21 IIBfTIFICATION NO. iist kc-oco C0iPATUIWE_ALgu q IMTE OF LEITER. M*i D03ET IO. %-Miuki7 DATE DISTRIBlJiED b\\*i p.m.
ORIGli?L PEPORT1 S!PPIRBiTARY N E f7.~ '~ ] ((py DISTRIBlHION:
REACTOR (P)
FUELCYCLE&
SAFEGlARDS (S) l%TERIALS GD.
- x. ~
IE FILES mr-EES IE FILES AD/SG AD/FPISI AD/RDI REGIONSI,II,III,IV,V PEGIONSI,II,III,IV,V PEGIONS I,II,III,IV,V V50]R BR P,-IV VSOJR BR. R-IV VSO3R BR. R IV LOS / tPA l4G 5715 ffSS / FCiS SS-395 NRP/D3L EOD l4G 7602 LCEB / tPA I,iB 5715 gGS / SG SS-881 NRP/IIE AEOD l13 7502 LO3 / IPA f4G 5715 NRP/DSI ASB? E/W 450 EOD I4G 7602 SAD /SP tiB-7210A ASLBP E/W 450 -
NRR/ DOL CENTPAL FILES 015 CBfTPAL FILES 016 ASLBP E/W 450 CSiTPAL FILES ( GRON)
CBITRat FILES (GR000 CSiTPAL FILES 016 PDR
.CB?TPAL FI R c - 96 m
c>
CiasYet?t!PTM5MP*
LPDR PDR e
PDR TEPA LPDR E A
d LcDR TEPA [ "JAN1 e igg;, c s~u;gnm 5 TtPA y
i ACTION:
o o
PRELIMINARY EVALUATION OF THE' ATTACHED REPORT INDICATES LEAD RESPONS FOLLOWUP AS SEDWN EELCW:
IE Z NRR[
ttSS 1 OTHER [
EES P3'. 8/1/8:
L<
- v. joy An\\u 5'
icau
GcmML DIA
'M DD 81= h0 00D j'
MISSISSIPPI POWER & LIGHT COMPANY Helpong Build Mississippi P. O. B O X 164 0, J AC K S O N, MI S SIS SIP PI 3 9 2 0 5
" j S M, Tc.f5'f January 9, 1981 Office of Inspectior. & Enforcement U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N.'.'.
Suite 3100 Atlanta, Georgia 30303 Attention: Mr. J. P. O'Reilly, Director
Dear Mr. O'Reilly:
SUBJECT:
Grand Gulf Nuclear Station Units 1 and 2 Docket Nos. 50-4 M/417 711e 0260/13525/15526 PRD-79/21, Final Report, Failure to Provide Qualified Instrumen-tatien in Safety Related Systems AECM-81/24 on December 5, 1979, Mississippi Power & Light Company notified Mr. J. K. Rausch of your office of a Potentially Reportable Defi-ciency (PRD) at the Grand Gulf Nuclear Station construction site.
The deficiency concerns General Electric's failure to provide sels-mically and environnentally qualified instru=ents for use in nuclear safety systems in the Balance of Plant (BOP) Power Generation Con-trol Complex (PGCC).
We have determined that this matter constitutes a reportable condition under 10CFR50.55(e) and 10CFR2j. This letter to you, with our final report attached and previous submittals, constitutes our required reporting of this matter under both 10CFR50.55(e) and 10CFR21 for the infor=ation which is now available.
1 Mr. N. E. Edge of MP&L notified Mr. F. Cantrell of your office by telephone of the reportability under 10CFR21 on June 12, 1980, i
and confirmed 10CFR50.55(e) time require =ents apply.
Yours trul,
r' ~ y W. P. McGaughy, J.
EWC:mt Attachments cc:
Mr. N. L. Stampley cc: (Continued on page 2)
Mr. R. B. McGehee Mr. T. B. Conner Member Middle South Utilities System
MISSISSIPPI POWER C2 LICHT COMPANY Mr. J. P. O'Reilly AECM-81/24 h1C Page 2 cc:
(Continued)
Mr. Victor Stelloi Director Division of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D.C.
20555 Mr. G. B. Taylor Sou:h Miss. Electric Power Associa:1cn P. O. Box 1589 Hattiesburg, MS 39401
Attechment A to AECM-81/24 Pcga 1 of 1 FINAL REPORT FOR PED-79/21 I.
Description of Deficienev In December, 1979, Bechtel (MP&L's Architect / Engineer) determined from General Electric purchased part drawings that several in-struments were not purchased nuclear safety related as required by Bechtel's design, Technical Information for Power Generation Control Complex (PGCC) Panel Mounted Instruments. Further in-vestigation revealed General Electric's failure to provide seismically and environmental 37 qualified instruments for use in nuclear safety related systems in the Balance of Plant (BOP)
PGCC.
II.
Safety Implications Attachment B provides a list of instruments affected. Several of these instruments (ones identified with an asterisk) at used to actively perform a set function (i.e., control enclosure building pressure, operate safety-related dampers, cause trip functions, etc.).
I= proper cperati:n of these devices would create a situation for which the plant accident analyses have not been considered and could, therefore, affect adversely safety of operation of the plant. This cendition is considered reporta-ble meeting the repoeting criteria of 10CFR50.55(e)(1)(1) and (ii) and 10CFR21, Para. 21.3(d)(1).
III.
Corrective Actions The problem involved 16 types cf in:cruments (manufacturer /model no.) that were not qualified. The tause of the problem was General Electric (GE)*interpretatics of Bechtel's requirements.
Any future customer specification requirements to be implemented by GE will be reviewed with customer to resolve any question /
disagreements on applicability of criteria prior to GE commit-ment to procure subject equipment.
The unqualified instruments are going to be replaced with instru-ments that are qualified to IEEE 323-1971 with subsequent quali-fication to IEEE 323-1974 and 314-1975. General Electric's action i
plan is to complete the qualification and replacement program by December 1981.
Details and implementation of corrective action are being tracked by Bechtel's Management Corrective Action Report, MCAR-59, which is available at the GGNS cite, l
i
Attrch=;nt B to AECM-81/24 Paga of 3 P/J:r.L I::".TP.r"rt:T 1:!.':: !'/(P'!:FP./::rO!::. ::o.
PS71 1171-TT-N612A
- Ronc=ount 442A D171-TT-5613A
- l!!71-YT-!:614A
- U!71 *IT-5615A
- 1!:71-TT-5616A
- SP41-rY-)* 603 A Es'1cy 752 1P41-1/E-R604A S..iley 766103 1TA S-JY-K6CSA
- CE 9T56Y 1T48-PDC-R503A
- Eci cy 740 1Z77-TT-N604 A Bailey 740 PS72 1E61-I/E-K6003 h iley 766 1E61-TT-56C4L h iley 740 Di71-JY-K6:03 C." ETSCY ll:71-r-N6053 & D niley 7!.0 l! 71-C-N6 Me, Mr=.cnnt 4!.1A l!!71 T-N6073 & D hiley 740 l!!71-TT-N6125 Resc=oun: 442A 11:71-T7-56133 11171-TT-N6143 D!71-TT-56153 l!!71-T -N6163 S?41-rY-K6033 Es.iley 752 1P41-I/E-K6Ct.3 Br.i'_ c y 766 1T4S-n'-K60S3 CT. 9T56Y 174S-PDC-ECC33 hilcy 740 1 !7-TT-N6043 E.iley 740 PS77 DI71-TT-N606C
'Eisc= cunt 44 A 1}!71-TT-N612C D171-TT-N613C Di71-TT-N 61!.C D:71-TT-N615C D171-TT-N616C l
1P41-1/E-K6C4C B:.iley 766 s
P878 D171-TT-K606D Rosc=ount 442A D171-TT-N612D D171-TT-N613D 11171-TT-K614D Et71-TT-N615D Y
D171-TT-N616D p.
.s' P864 1R21-XI-R611A & B GE A3-40
/-
1R21-XL-R700A & B Kirkl:nd S-14 k
i s
Perfortis active saf ety function
\\.
(.
Attech:nent B to AECSI-E1/24
{Pcg22of3 l'A';EL T:; *.TRt*':"!:T Iu'::'F/.CT"RER/!'0 DEL !;0.
P855 Sz51.1Y-K600A & B GE 9T56Y SZ51-H'R-n003A & B Bailey 771 SZ51-PR-R60.A & L Esiley. 771 SZ51-XI.-R70: A-11 JAY-EL lIR I!
SE51-XL-R702A-H J AY-EI. 2:K II PS64 IP75-1:S-1:750A & B "cc:ingh:uce FT-1 1P75-EI-R600 A & B GE 15 0 1P75-SI-R601A & B GE ISO 1P75-JI-R602A & B GE ISO 1P75-JI-R603A & 5 GE 1EO 1?75-II-R604A & B GE 13 3 1P75-EI-R605A & B GE 153 1P75-II-R6C6A & B GE 1E5 1P75-LI-R607A & B GE 15 5 1?75-LI-R60SA & B GE 1E5 1P 75-X:.-R701A-G JA'.*-EL !Z II 1P 75-XI.-R702A-C JAY-E* 12 II 1R20-HS->i769A & B Westinghouse FT-1 We::ingh: se 7FT-1 1R20-l!S-1:770A & B 1R20-HS-:1771A & B Westingh:use FT-1 1R20-HS->;772A & B Westingh:use FT-1 1R20-HS-!!773A & B Westinch:use FT-1 1R20-ES->:774A & B Wes:ingh:use FT-1 1R20-IT-R627A1, A, B1, B GE 1E5, cci-Coil SA/20!!A 1R20-E -R62SA & B GE.lE5 1R20-IT-RG29Al, A, B1, B GE 155, Cal.-Coil SA/20}!A 1R20-EI-R630A & B GE IS5 1R20-IT-R631A,A,B1,B CE lES, Cal.-coil 5Al20!!A 1R20-EI-R632A & B GE 155 1R20-IT-R 63 3A1, A, B1, B GE ISS, cal-Coil SA/2C}!A 1R20-EI-R634 A & B GE 155 1R20-IT-R 635 A1, A, B1, B CE 1S5, Cal-Coil SA/20}!A 1R20-EI-K636A & B GE ISS 1R20-EI-R647A & B GE 155 1R20-IT-R 64 SA1, A, B1, B GE ISS, Cal-Coil SA/20)!A 1R21-HS->:600A & B G E S E!!
1R21-115-!!747A & B Westinghouse FT-1 1R21-HS-1174SA & B Westinghouse FT-1 1R21-HS->:749A & B Westinghouse FT-1 IL21-EI-R603A & B GE ISO 1R21-EI-R610A & B GE ISO 1R21-EI-R612A & B CE 100 1R21-IT-RG13A1,A,B1,B GE ISS, Cal-Coil SA/2C}!A
~ _N 1R21-EI-R615A & B CE ISS f<;
1R21-IT-R 616Al, A, B1, B Cc 1SS, Cal-Coil SA/20!%
i lR21-lT-R617A1, A, B1, B CE ISS, Cal-Coil SA/20!!A
- 3 r
% ~k,.
\\
1R21-XL-R702 JAY-rL' it. Il e,
~.......
/.ttrchment B to AECM-81/24 Pcga 3 3
(
A
.s l'A!:r E.Ti nr!t hv!)r.1. ::1 PA*:CL 1NSTRr:T':T PS64 1R21-XL-R7C1 JAY-E!. II51 PS70 1E30-LR-R600.'. f. B nailey 771 lE30-XL-R701A-H JAY-EL MR II lE30-XL-R702A-H JAY-IL MK.II lE61-!!CS-:321A' & B L & :: S248 lE61-PDR ".C01A f. B Dailey 771 1E61-AR-R602A & B t.iley 771 lE61-TI-R603A & B CE 1.t "
1E01-JI-R6C4A & B CE 13C 1E61-XL-R7 0LA-H,J,K JAY-;L MR II lE61-XL-R7 02A-11,J,K
!/a*.L 1E II D171-PDF,-R601A & B Bail:y 771 1M71-TR-R602A & B D:71-TR-F:03A & B lI:71-TJRS-REC 4A & 3 Di71-TR-R603A & B & C & D
'D171-XL-R701A-E J AY-E~.
1E II D 71-XI.-R702A-E 1P41-FI-R601 GE 100 1P41-PI-R6C2 CE 1S0 1P41-LR-F.60' A & B B iley 771 1P41-11R-F.606A & B JP41-XL-R7C1A-H,J K JAY-IL I'E I_I l
1P41-XL-R7 C2A-li,J.K 1P41-XL-R7C3A,B & C 1P42-XL-R701A-D 1P42-XL-R702A-D 1P53-RS-M612A&3 GE CR29'0 1P64-HS-M629A & B $
1P81-LI-R600 CE 155 1P 81-I.1-F 6Ci l?S -XL-R7CO JAY-EL 1E II LP,Sl-XI.-R7 C1 It'01-XL-R7 C 2 1T48-FR-R600A & B Bailcy 771 1T48-PDR-R601A & B 1T48-PDR-R602A & B IT4 S-XL-R7 C1P.-H,J JAY-EL MK II f
1T4S-XL-K702A-H,J 1E61-HC-R605A & B
- Bourns 3650 PS71 lE61-I/E-R600 A Bailey 766000 1E61-TT-560'. A Bailey 740
,['%-
D171-JY-R600A CE 9 56Y D171-TT-N605A & C Br.iley 740 g
i-IM71-TT-5606A Rosecount 442A
'.c.I i
Ut71-TT-5607A & C
- 11:11cy 740 t
\\
s.
v
- ~: _-..
____