i Comments on the NRC Safety Research Program Budget for Fiscal Years 1984 and 1985 l

U.S. Nuclear Regulatory Commission Advisory Committee on Reactor Safeguards pa =< coq hf l

888 Fura!

0875 R PDR

NOTICE Availability of Reference Materials Cited in NRC Publications Most documents cited in N RC publications will be available from one of the following sources:

1. The NRC Public Document Room,1717 H Street, N.W.

Washington, DC 20555

2. The N RC/GPO Sales Program, U.S. Nuclear Regulatory Commission, Washington, DC 20555
3. The National Technical Information Service, Springfield, VA 22161 Although the listing that follows represents the majority of documents cited in NRC publications, it is not intended to be exhaustive.

Referenced documents available for inspection and copying for a fee from the NRC Public Docu-ment Room include N RC correspondence and internal NRC memoranda; NRC Office of Inspection and Enforcement bulletins, circulars, information notices, inspection and investigation notices; Licensee Event Reports; vendor reports and correspondence; Commission papers; and applicant and licensee documents and correspondence.

The following documents in the NUREG series are available for purchase from the NRC/GPO Sales Program: formal NRC staff and contractor reports, NRC-sponsored conference proceedings, and N RC booklets and brochures. Also available are Regulatory Guides, N RC regulations in the Code of Federal Regulations, and Nuclear Regulatory Commission issuances.

Documents available from the National Technical Information Service include NUREG series reports and technical reports prepared by other federal agencies and reports prepared by the Atomic Energy Commission, forerunner agency to the Nuclear Regulatory Commission.

Documents available from public and special technical libraries include all open literature items, such as books, journal and periodical articles, and transactions. Federal Register notices, federal and state legislation, ar'd congressional reports can usually be obtained from these libraries.

Documents such as theses, dissertations, foreign reports and translations,and non NRC conference proceedings are available for purchase from the organization sponsoring the publication cited.

Single copies of NRC draft reports are available free upon written request to the Division of Tech-nical Information and Document Control, U.S. Nuclear Regulatory Commission, Washington, DC 20555.

Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at the NRC Library, 7920 Norfolk Avenue, Bethesda, Maryland, and are available there for reference use by the public. Codes and standards are usually copyrighted and may be purchased from the originating organization or, if they are American National Standards, from the American National Standards Institute,1430 Broadway, New York, NY 10018.

GPO Printers copy price: _ $32_ __

NUREG-0875

= _

Comments on the NRC Safety Research Program Budget for Fiscal Years 1984 and 1985 Manuscript Completed: July 1982 Date Published: July 1982 Advisory Committee on Reactor Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555 f.....w.

/

p ucqDo UNITED STATES

~

8 NUCLEAR REGULATORY COMMISSION e,

,E ADVISORY COMMITTEE ON REACTOR SAFEGUARDS WASHINGTON, D. C. 20555

/g July 14, 1982 Honorable Nunzio J. Palladino Chairman U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Dr. Palladino:

The Advisory Committee on Reactor Safeguards is pleased to transmit its comments on the Office of Nuclear Regulatory Research Budget proposed for Fiscal Years 1984 and 1985.

Only that portion of the budget relating to Program Support has been considered.

No attempt has been made to distinguish between Program Support Funds for research and for work related to standards development, since the latter represent a relatively small proportion of the total.

The proposed funding levels considered are those included in the recom-mendations of the Executive Director for Operations which were provided to the Committee for its 267th meeting, July 8-10, 1982.

We will be pleased to discuss these comments with you and the Commis-sioners, if you desire.

Sincerely,

\\

P. "Shewmon Chairman

l TABLE OF CONTENTS PAGE 1.

INTRODUCTION.......................

1 2.

GENERAL COMMENT

S.....................

1 2.1 Introduction.

1 2.2 Light-Water-Reactor (LWR) Safety Approach in Other Countries.....................

I

2. 3 Design-Related Sa fety Research..........

1 2.4 Externally-Produced Floods............

2 2.5 Seismic Effects in Control Room.

3 2.6 Design Against Sabotage..............

3 3.

SPECIFIC COMMENTS AND RECOMMENDATIONS...........

4 3.1 Reactor and Facility Engineering.........

4 3.1.1 Mechanical Engi neeri ng..............

4 3.1.2 Seismic Safety Margins Research Program (SSMRP)..

4 3.1. 3 Pr1.'ary System Integrity..

4 3.1.4 Electrical Equipment Integrity..........

5 3.1.5 Process Control..................

5

3. 2 Fa c i l i ty Ope ra t i on s................

5 3.2.1 Human Engineering and Man-Mach ne.........

5 3.2.2 Plant Instrumentation and Control.........

5 3.2.3 Occupation al Protection..............

6 3.2.4 Sa f e g u a r d s....................

6

3. 3 Thermal Hydraulic Transients...........

7 3.3.1 Semi scal e and M00-5................

7 3.3.2 Transient Models and Codes............

7 3.4 Si ti ng and Heal th.................

8 3.4.1 Earth Sciences..................

8 3.4.2 Site and Environment.

8 3.4.3 Health Effects..................

8

3. 5 Risk Analysis........

8 3.5.1 General......................

8 3.5.2 Risk Methodology and Regulatory Analysis.....

8 3.5.3 Reactor Risk Analysis...............

9 v

I l

PAGE s

3. 6 Accident Evaluation and Mitigation.

9 3.6.1 General......................

9 3.6.2 Severe Accident Analysis.............

10 3.6.3 Damaged Fuel...................

10 3.6.4 Containment Loading................

10 3.6.5 Fission Product Source Term............

11 3.6.6 Improved Safety Systems..............

11

3. 7 Loss-of-Cool ant Accidents.............

11 3.7.1 2D/30 Program...................

11 3.8 LOFT.......................

11 3.9 Advanced Reactors.................

12 3.9.1 Clinch River Breeder Reactor (CRBR)........

12 3.9.2 Probabilistic Risk Assessment of CRBR.......

12 3.10 Waste Management.

12 3.10.1 Ge n e r a l......................

12 3.10.2 Comments on Waste Management Programs.......

13 4.

BUDGET RECOMMENDATIONS..................

13 4.1 Fiscal Year 1984..

13 4.2 Fi scal Yea r 1985.................

14 TABLE 1 - 0FFICE OF NUCLEAR REGULATORY RESEARCH PROGRAM SUPPORT BUDGET FOR FISCAL YEARS 1984 AND 1985........

17 APPENDIXES..........................

19 APPENDIX A - REFERENCES..................

21 APPEliOIX B - GLOSSARY...................

23 I

l l

l vi l

1

l 1.

INTRODUCTION Our comments are divided into three parts.

Section 2 relates generally to programs for which we think greater effort or emphasis is needed.

Section 3 provides specific comments on the proposed programs in each Decision Unit and, in most cases, for individual Subelements within each Decision Unit.

Specific recommendations regarding the Research Program Support Budget are given in Section 4.

2.

GENERAL COMMENT

S 2.1 Introduction The Office of Nuclear Regulatory Research (RES) still fails to give to certain programs the emphasis recommended by the ACRS.

Several of the more important programs in this category are discussed in the remaining portion of this Section, and recommendations for funding, as appropriate, are given in Section 4.

2.2 Light-Water-Reactor (LWR) Safety Approach in Other Countries There now exist increasingly sophisticated approaches to LWR safety, or specific aspects thereof, in many foreign countries including France, the Federal Republic of Germany (FRG), Japan, Sweden, and the United Kingdom.

The NRC Staff should make a major effort to remain current concerning such developments, including not only a knowledge of differences from U.S. practice but also the detailed reasons for these differences.

For example, the Japanese have specific approaches to seismic design and qualification, the British have developed many significant additional safety requirements for their version of the Standardized Nuclear Unit Power Plant System (SNUPPS), and the Germans and Swiss, among others, have developed special requirements for shutdown heat removal and sabo-tage protection.

The NRC Staff appears to have maintained a casual, even parochial, atti-tude with regard to understanding foreign safety approaches to LWRs.

RES should devote enough resources to this task so that, working in concert with the Office of Nuclear Reactor Regulation (NRR), they can develop the relevant information expeditiously.

2.3 Design-Related Safety Research In our previous report to the Commission (Ref.1)*, we called attention to an aspect of safety research that has been weak or deficient in the past

  • References appear in Appendix A.

1

NRC program, namely design-related safety research and analysis.

We noted the importance of a knowledge of design possibilities, capabilities, costs, and tradeoffs, and called attention, as examples, to the need for more effort of this kind in the areas related to severe accident rulemak-ing and design to reduce the potential for sabotage.

The recently initi-ated studies of detailed plant behavior in support of the Unresolved Safety Issue, Task Action Plan A-47 (Ref.2), on the Safety Implications of Control Systems is an example of such rasearch.

Another example is an examination of the relative merits of an improved direct capability for pressure reduction in the primary system of a pressurized water reactor (PWR) compared to increased diversity and/or redundancy in the auxiliary feedwater system.

Automatically controlled pressure restoration and direct control of pressure to suitably low values af ter a chilling tran-sient, along with automatic restoration, if necessary, of core submergence (or other mode of cooling) might be worth investigating as a solution to the current Pressurized Thermal Shock (PTS) problem.

We believe that a thoughtful program of design-related safety research and analysis should be instituted.

2.4 Externally-Produced Floods There is fairly general agreement that it is now di f ficul t to quantify the contribution to risk from accidents which arise from externally-produced floods.

The uncertainties in any estimate of the recurrence frequency of the " probable maximum flood" are very large, and the degree of protection afforded by the approach currently approved by the NRC Staff may vary widely from site to site.

Although we have recommended on several occasions that priority be given to research on flood probabilities in the NRC Safety Research Program, the NRC program includes no flood-related research in FY 1982 and 1983.

However, we are pleased to note that about $0.5 million per year is

+

proposed currently for flood-related research both in FY 1984 and 1985.

In addition to a continuing inability to assess the adequacy or the possible excessive stringency of the current requirements for flood protection, the low priority given to this matter by the Staff in the past leaves the NRC ill-equipped to deal with flooding in connection with the newly proposed NRC safety policy.

For example, the adequacy of design basis flood conditions is being questioned in several plants as part of the Systematic Evaluation Program.

Decisions regarding the allocation of resources in backfitting cases such as these may require, or could benefit from, flood probability guidance.

We believe that the NRC should maintain the necessary priority for flood-related research in FY 1984 and 1985, and should accomplish some repro-gramming of money to this task in FY 1983.

We recommend that the NRC 2

state its intention to support research in tnis area, set aside appro-priate funds, and encourage the receipt of well thought-out proposals from recognized experts having the potential for making a significant contribu-tion to NRC needs in this area.

An area for emphasis should be that to obtain improved knowledge of increasingly severe precipitation conditions and the accompanying hydrological status (or at least a better definition of the uncertainties and their causes).

2. 5 Seismic Effects in Control Room The NRC has research programs on Human Factors, Seismic Safety, and Severe Accident Sequence Analysis, including some evaluation of the emergency operating procedures currently under development by the indus-t ry.

In addition, work is underway or contemplated on prioritization of ala rms.

However, a topic not specifically identified is the matter of how severe earthquakes nay unpredictably and simultaneously impact a nuclear power plant in a large number of different ways, leading not only to a transient and/or possibly concurrent small LOCAs, but also to an indeterminate set of failures in non-safety systems, possible failure of some engineered safety features, a loss of most of the information normally available to the control room, and the existence of spurious information.

The vendors maintain that their newly developed symptom-oriented proce-dures should be adequate for the seismically induced transient / accident, as well.

However, this is currently a poorly studied area, and warrants a well-focused safety researcr. effort that takes advantage of other relevant programs.

2. 6 Design Against Sabotage On several prior occasions, we have recommended that the NRC Staff perform necessary research to obtain enough information to enable the NRC to de-velop a regulatory approach regarding the matter of what additional provisions, if any, should be included in LWR design to reduce the likeli-hood of a serious accident arising from sabotage by insiders or outsiders.

The NRC Staff has performed some safety research in this area.

However, the Staff states that budget constraints have limited the extent to which they are developing a regulatory policy on possible design approaches to prevent sabotage.

We believe tnat it is time this matter received the needed priority.

We anticipate that the attempt to write a proposed rule and/or the comments from the nuclear industry will clarify further research needs requiring substantial funding beyond that currently contemplated by the Staff, if this matter is to be dealt with in a timely fashion.

3

3.

SPECIFIC COMMENTS AND RECOMMENDATIONS 3.1 Reactor and Facility Engineering 3.1.1 Mechanical Engineering Redirecting some of this effort toward showing the effect of allowing ductile fluid system boundary piping to work in the inelastic deformation range would be of value in clarifying the failure potential associated with malfunction of anchors and snubbers, unanticipated thermal movement, and mislocation of restraints.

Since such errors cannot be totally avoided by design, there is a need to show that some structural tolerance exists for this type of error.

In addition, much of the safety significance of pressure system ruptures is dependent upon the manner in which system ruptures occur and how the rupture size is affected by fluid system forces applied to the rupture opening. Not enough has been done to relate system pressure change, fluid mass flow, and rupture geometry in a manner that would give realistic characterization of the effects of fluid system ruptures on public safety matters. Recent events at the Ginna Nuclear Power Plant, as well as prior concerns for asymmetric loads under postulated guillotine pipe ruptures, further emphasize the importance of such research.

The plai: for develop-ing improved understanding of rupture behavior should be clarified prior to implementation of the FY 1984 safety research program in this area.

3.1.2 Seismic Safety Margins Research Program (SSMRP)

NRR has recently issued a strong user need request for short-term and long-term probabilistic seismic analysis methodology.

Although we have been critical of the SSMRP in the past, we have been urging the develop-ment of such an analytical capability and support NRR's request. Further, we reiterate our previous recommendation that the SSMRP include a limited probabilistic seismic safety study of a boiling water reactor.

3.1.3 Primary System Integrity The proposed program on Primary System Integrity is so'und.

The increased funding is primarily for work on material fracture in relation to the con-cern about possible pressure vessel rupture resulting from PTS.

The program should provide a basis for regulatory decisions concerning:

(a) Which, if any, available nondestructive-examination techniques would allow one to determine if the irradiated region of the pressure ves-sel is free of cracks that can give rise to catastrophic consequences from PTS events.

4

(b) The problems associated with annealing an irradiated reactor pressure vessel in place.

3.1.4 Electrical Equipment Integrity This program continues to include fire qualification work.

We still believe that the fire safety work should be supported by industry spon-sors, but concede that if the need is as urgent as the NRC Staff believes, then NRC funding might be justified.

3.1.5 Process Control This program appears to be in need of a better definition of its goals and of improved organization.

3.2 Facility Operations 3.2.1 Human Engineering and Man-Machine The proposed budget and scope for Human Factors research have been in-creased significantly in FY 1984 and 1985, continuing the trend of the past few years.

We believe that this trend is appropriate and that the proposed funding levels are adequate.

The NRC Staff has responded satis-factorily to the concerns related to the Human Factors research program as expressed in our report to the Congress (Ref. 3). We believe that the new and modified programs proposed for FY 1984 and 1985 will be of substantial benefit; however, consideration should be given to an expanded program di-rected toward reducing the safety impact of human failure in maintenance and testing.

We also note that there is a trend toward increasing re-search on human performance as compared to that on the machine aspects of the human-machine system. We believe that this trend should continue into future years.

3.2.2 Plant Instrumentation and Control We continue to support research in this area.

The proposed budget for FY 1984 and 1985 represents a significant increase over the FY 1982 and expected FY 1983 funding levels.

We endorse the proposed levels of fund-ing for FY 1984 and 1985.

Nevertheless, based on our review of the on-going and the proposed research in this area, we believe that the major activities being conducted are comparatively new and are trying to find a mission.

We believe that they have not yet succeeded. What is needed is a more careful definition of the problems to be solved and the questions to be answered.

We believe that the ongoing and the proposed work should be reexamined to establish relevance to NRR licensing needs and to determine its effective-ness on a cost-benefit basis.

The review should address the timeliness of 5

the expected results, and whether the specific projects planned are more properly an industry or NRC responsibility. We believe that NRR should be an active participant in this review.

The work as currently planned appears to put too much emphasis on the be-havior of specific systems and components and not enough on the develop-ment of a statement of safety needs and performance criteria.

We believe that this is a weakness that must be remedied.

We believe especially that the work that is directed toward evaluating and developing methods for defining the safety implications of control systems should be given a high priority and should be directed toward the prompt resolution of the Unresolved Safety Issue, Task Action Plan A-47 (Ref. 2),

on the Safety Implications of Control Systems.

It is unlikely that this will be achieved under the current work plan.

We urge that additional planning effort be given to the tasks of this Subelement and that better coordination be established with users of the expected results.

3.2.3 Occupational Protection As mentioned in our May 12, 1982 letter to the Executive Director for Operations (Ref. 4), we believe that greater effort needs to be directed to occupational protection.

A concerted effort should be made to gain a better understanding of the control of radionuclides and their removal from nuclear power plant cooling systems.

A clearer definition of overall goals and objectives, and a specification as to how each research project assists in the attainment of these objectives would be beneficial.

Among the specific projects reviewed, the one on Optimization Studies may de-serve increased funding support for both FY 1984 and 1985.

3.2.4 Safeguards This Subelement includes a nun aer of routine--though necessary--chores which will require continuing attention.

These include support for new rules and guidance, equipment acceptance criteria, optimization of the use of inspection manpower, and study of the vulnerability of Independent 2

Speht Fuel Storage Installations. The budget for this Subelement has been drastically reduced ($3.6 M in FY 1982, $2.2 M in FY 1983, and $1.0 M in FY 1984-1985).

This appears to be appropriate, at least so far as items of the sort referred to above are concerned.

However, there are several safeguards projects which deserve greatefk emphasis in FY 1984 and 1985.

These include studies of both design @ human factors to minimize the likelihood of sabotage by insiders, and studies to acquire knowledge of foreign technology for safeguards against sabotage.

The budget should be set and/or apportioned to enable studies of these matters.

W s

?

?

I e

6 a

s j

s J

3. 3 Thermal Hydraulic Transients 3.3.1 Semiscale and MOD-5 There are many integral facilities that simulate the Westinghouse type PWR.

Among these are Semiscale, LOBI, PXL, CCTF, and SCTF.

We endorse the possibility that the NRC will play a role in the integral Japanese facility, ROSA-IV.

It should be noted that all of these f acilities use electrically-heated rods and have received some criticism for this reason.

Some of the differences in performance between nuclear and electrically-heated rods have been overcome in recent designs and the remaining differences are understood and can be compensated for by proper analysis of tests.

There is a need for an integral f acility that would simulate the Babcock &

Wilcox type PWR.

We strongly urge that the proposed Semiscale h00-5 be made available as soon as possible for this simulation.

Without such a facility, it is dif ficult for NRR to perform its required regulatory func-tions for this family of reactors.

We reiterate our previous recommenda-tion that the NRC seek significant financial contribution from industry for this effort.

Further, we believe that the Semiscale MOD-S facility should be located at the Idaho National Engineering Laboratory so that the program can profit from the significant experimental and theoretical ex-perience already gained with other versions of Semiscale.

3.3.2 Transient Models and Codes We note with approval the continuing development of the advanced codes, RELAP and TRAC.

Much of the basic development has already taken place although further improvements are expected.

Continued code assessment is required, but the assessment program should be reviewed carefully since funding for it has been seriously reduced. As a general point, we continue to favor strongly the continued development and use of RELAP.

There are some particulars in the advanced code programs which should be mentioned.

Tne transferability of the codes needs considerable improve-ment.

By transferability, we mean use of the code by others rather than the original developing group.

Apparently, the RELAP instruction manual is more useful than the manual for TRAC, but improvements in botn are needed.

It would seem desirable to reduce significantly the number of special codes developed and used oy the NRC.

Some of these codes are of marginal value.

7

I 3.4 Siting and Health 3.4.1 Earth Sciences We recommend that the proposed experimental program on Atmospheric Disper-sion be deferred in order to provide funding for other higher priority research.

3.4.2 Site and Environment There nay be a need for increased support of the project on the Socio-economic Effects of Accidents. Aspects of this work pertaining to psycho-logical impacts appear to be particularly important.

3.4.3 Health Effects The work in this Subelement is well coordinated with related research oy other Federal agencies.

Particular projects for which we recommend sup-port are:

(a) Gastrointestinal Absorption of Actinides, and (b) Relative Biological Effectiveness of Fission Neutrons at Occupational Exposure Levels. Witn respect to this latter project, some benefit might be gained through a detailed examination of the records of the Department of Energy (D0E) relative to neutron exposures of workers in plutonium f acilities.

3. 5 Risk Analysis 3.5.1 General Although in the letter f rom R. B. Minogue, RES, to R. F. Fraley, ACRS, dated May 27,1982 (Ref. 5), the NRC Staff agreed in detail or in princi-ple with almost all of the recommendations made in our previous report to the Congress (Ref. 3) concerning the Risk Analysis (previously Systems and Reliability Analysis) Decision Unit, for many, if not most, of these rec-ommendations the proposed level / scope of effort is not sufficiently re-sponsive eitner to our recommendations or to the needs of the NRC.

3.5.2 Risk Methodology and Regulatory Analysis The proposed effort on nethodology for incorporating risk cont ributors such as seismic events, design errors, operator errors of commission, sabotage, and systems interactions into probabilistic risk assessments (PRAs) is inadequate for tne need.

The possible introduction of quantita-tive safety guidance into the regulatory process adds emphasis to the need for such nethodology. A focused, priority effort should be placed on each 8

of these matters either to provide a method suitable for incorporation I

into PRAs on a trial basis or to identify and evaluate the sources of uncertainty which make this impractical and to suggest regulatory ap-proaches in the light of these uncertainties.

The proposed programs on LWR Safety Approach in Other Countries, Design Against Sabotage, and Externally-Produced Floods are discussed in Section 2.

i 3.5.3 Reactor Risk Analysis The ongoing program on core damage and core melt prevention and mitigation features is inadequate for the needs of the NRC.

It does not include, or includes on too modest a basis, the effects of external events.

It does not adequately treat or evaluate the role of uncertainties.

It lacks I

sufficient conceptual design backup.

This program should be augmented markedly, preferably in FY 1983 rather than waiting until FY 1984.

3.6 Accident Evaluation and Mitigation 3.6.1 General We have recommended repeatedly in our reports to the Commission and to the Congress that the research in the Accident Evaluation and Mitigation Decision Unit be structured to answer questions arising in connection with reactor regulation and licensing.

In our recent reports, specific atten-tion was called to the need for organizing the research under this Deci-sion Unit to answer questions likely to arise in connection with the Commission's stated intention to modify the licensing process to take specific account of accidents more serious than those generally identified as Design Basis Accidents.

However, there is still a lack of definition of even one approach to deal with the severe accident issue. Considering the difficulty of the problem, effort should probably be made to define several alternatives. Until these efforts have produced some initial results, guidance for research of the type described will not be avail-able.

Although efforts are said to have been made to describe a correlation between the regulatory process and the research program, we find little identification of soecific questions associated with rulemaking, or with other means for dealing with severe accidents, that can be answered by the proposed research.

As a result, this Decision Unit, which represents a significant fraction of the proposed research budget, has the appearance of a heavily loaded cannon which may be aimed at the wrong target.

9

3.6.2 Severe Accident Analysis In this area, there is najor empnasis on code development, and on the de-tailed analysis of some of the more obvious accident sequences brought to light by the TMI-2 accident, and by the possibility of PlS. These deserve attention, but there snould also be investigations, on a less detailed basis, of other less obvi ou s sequences.

Additional effort should go toward attempts to identity initiators and sequences not yet encountered by operating nuclear power plants.

We support the concept of some research ef fort that tries to consider the impact of various, possible actions by the licensee during the course at an accident involving severe core damage or core nelt.

However, we are skeptical that this effort is likely to evolve into detailed re gu latory requirements in the forseeable future.

We cannot support major expendi-tures in this ared based on currently available inf ormation and would not use tnis program to justify an expensive experimental program.

3.6.3 Damaged Fuel Phase I experiments being performed in the Power Burst Facility (PBF) will provide useful information.

Current ef forts are aimed at " understanding,"

but the processes being studied are so conplicated and the research so expensive, that better definition of the questions to be answered should precede the research.

We have previously questioned the amount of detail that it is possible or desirable to define in an actual accident.

Signi-ficant additional attention should be given to this question in order that the research will be useful.

With this in mind, we do not recommend the work planned in the Atomic Energy of Canada Ltd., Test Reactor (NRU),

Annular Core Research Reactor (ACRR), or Phase 11 experiments in PBF at this tine.

3.6.4 Containment Loading In our previous report to the Congress (Ref. 3), we stated that the exper-iments underway and contemplated are elaborate and expensive, but we have not seen evidence indicating tnat they reflect adequately the processes that will be critical in defining the rate of dama9e evolution.

A more coherent analysis should be nude to define the most probable evolution of the accident and to identify the critical information required to assess accident progression.

The code development work associated with these studies is extensive.

Howeve r, not enou gh attention has been given to the question of how much detail is desirable or feasible.

We have no additional inf ormation that changes this view.

10

3.6.5 Fission Product Source Term Work under this Subelement appears to be well managed, and funding f or FY 1984 and 1985 seems adequate.

We urge that continuing attention be given to the information needed for licensing and regulatory decisions.

A significant part of the funds requested are for development of a variety of codes, and experimental work is justified partly as being needed for validation of the codes.

Careful, early planning must ensure that the codes are likely to contribute the information needed for decision-making and do not simply become ends in themselves.

We believe that the peer review process being used will help to prevent this.

The related research on better definition of the source terms for accidents in LWR fuel cycle facilities and in facilities using radioactive materials should be sub-jected to similar planning and review, and should be better coordinated with the work pertaining to nuclear power plants.

3.6.6 Improved Safety Systems We urge that work in this area take advantage of the increasingly sophis-ticated approaches to LWR safety in many foreign countries (see Section 2.2).

3.7 Loss-of-Coolant Accidents 3.7.1 2D/3D Program This program was designed to contribute to the understanding of large-break LOCAs in PWRs.

Tne large-break LOCA has been a safety question of decreasing concern relative to other possible transients. At present, the major project in this program is the proposed construction of the Upper Plenum Test Facility (UPTF) by the FRG.

If the FRG proceeds with the construction of this facility, it will require long-term expenditures by the U.S. NRC to support analyses and instrumentation.

The estimated cost of UP1F has risen to such an extent that there is even greater concern with the benefit, which is quite small, for a very large expenditure. As an additional comment on UPTF, it should be noted that not only is it di-rected toward the Westinghouse type PWR but it also has as a major objec-tive the study of hot-leg injection which is a feature special to the FRG type PWR.

We reiterate our previous reconinendation that the NRC expendi-tures for this program be reduced to the absolute minimum consistent with the international agreement governing this effort.

3. 8 LOFT There are discussions under way at this time regarding the formation of a consortium that would obtain considerably increased financial support from abroad for continuing a test program in LOFT.

We wish to point out 11

~\\

again that test programs in a nuclear f acility are more costly and require much longer test times than in an electrically-heated f acility. Tnere are already test f acilities available with electrically-heated rods that have other significant advantages over LOFT. Our analytic capabilities are now suf ficiently mature to correct for diff erences between electrically-heated rods and nuclear rods.

It is therefore, in our view, undesirable to give f avorable consideration to an extended program in LOFT.

3.9 Advanced Reactors 3.9.1 Clinch River Breeder Reactor (CRBR)

The entire Liquid Metal Fast Breeder Reactor (LMFBR) research effort is being directed to support CRBR licensing.

The proposed budget for FY 1984 and 1985 appears adequate for that purpose.

However, we believe that funding should be provided also for generic safety research aimed toward plants significantly larger tnan CRBR, if Congress continues to support LMFBR development.

We repeat the recocoendation in our previous report to the Congress (Ref. 3) that $1.0 million be earmarked specifically for research to aid the development of a regulatory position f or post-CRBR LMFBRs.

3.9.2 Probabilistic Risk Assessment of CRBR We recommend that the NRC Safety Research Program include a PRA of the CRBR.

The background and experience gained by such a study is needed f or a proper evaluation of the PRA being performed by the CRBR project as well as to provide long-term guidance f or future LMFBR research.

3.10 Waste Management 3.10.1 General We believe that the proposed funding for Waste Management Research for FY 1984 and 1985 should be supplemented by $1.0 million per year to recover part of the funds taken f rom this ef fort to support Semiscale M00-5.

Particularly, we would like to see the restoration of the cuts made in the Low-Level Waste (LLW) Program relating to Engineered Disposal and Shallow-Land Burial Alternatives, Characterization of Cnemically Toxic Components of LLW, Nondestructive Tests (NDT) f or Waste Packages, and the Source Terms of Radionuclides, as well as those aspects of the High-Level Waste Program relating to the Fracturing and Geomechanics of Jointed Rock.

With the recommended supplement, we believe that the funding would be ac-ceptable for planning purposes; however, a number of actions currently being contemplated by the Congress and DOE may cause even this level to be inadequate.

Such actions include the accelerated schedules proposed by 12

both DOE and the Congress for the construction and operation of a high-level waste repository.

Should these proposals be confirmed, a sizable increase may become mandatory.

3.10.2 Comments on Waste Management Programs In the way of comments on other aspects of the current Waste Management Program, we offer the following:

(a) The Program has definitely matured over the past few years, and the methodology for selecting specific areas for study and assigning priorities for actions has improved significantly.

(b) We are encouraged by the steps being taken to subject the Program to peer review. Our only caution is that those involved in such reviews be given an opportunity to become sufficiently informed about the Program to enable them to make effective recommendations.

(c) We continue to be concerned about an apparent lack of awareness on the part of the NRC Staff and its contractors of existing data that may be relevant to some of the basic technical questions being asked in the areas of rock mechanics, mining engineering, and geochemistry.

A more aggressive effort to seek relevant data, particularly fran other government agencies such as the Bureau of Mines, Bureau of Reclamation, and Corps of Engineers, is recommended.

(d) Although cooperation with DOE officials at the upper levels appears good, we note a lack of a full interchange of ideas and data at the technical working level.

In some cases, for example, it appears that data provided by DOE to NRC may be incomplete or " sanitized."

Efforts should be made to correct this situation.

4.

BUDGET RECOMMENDATIONS Our recommendations for changes in the proposed levels of funding are given in Table 1 and explained and discussed below as they relate to the recommendations in Sections 2 and 3.

4.1 Fiscal Year 1984 (a) We recommend no change in the total budget.

(b) We recommend an increase of $1.5 million for Decision Unit 2, Facil-ity Operations, to be allocated as follows:

  • $0.5 million for a program on Seismic Effects in Control Room, as discussed in Section 2.5.

13

  • $1.0 million for research we expect to be needed in FY 1984 on Design Against Sabotage, as discussed in Section 2.6.

(c) We recommend elimination of the experimental program on Atmospheric Dispersion in Decision Unit 4, Siting and Health, with a reduction in funding of $0.9 million.

(d) We recommend an increase of $3.0 million for Decision Unit 5, Risk Analysis, for the following purposes:

  • $1.0 million for increased effort on Risk Methodology and Regu-latory Analysis, as discussed in Section 3.5.2.
  • $1.0 million for increased effort on Reactor Risk Analysis, as discussed in Section 3.5.3.
  • $1.0 million for work relating to LWR Safety Approach in Other Countries, as discussed in Section 2.2.

In connection with the last item above, we recognize that the effort and funding may not appropriately belong solely within this Decision Unit.

It should cut across existing lines and may be in part a Standard's effort.

(e) We recommend a reduction of $5.6 million in the program on Damaged Fuel in Decision Unit 6.

This reduction is recommend 2d partly to emphasize and be consistent with our dissatisfaction with this program, as expressed in Sections 3.6.1 and 3.6.3, and partly t.,

provide funds for the increases reccmmended for important research in other areas.

We note that this reduction would not be needed if the

$10.0 million allocated to the LOFT Consortium could be used instead for other areas.

Your attention is directed to our comments on the LOFT program in Section 3.8.

(f) We recommend an increase of $1.0 million for Decision Unit 9, Ad-vant.ed Reactors, for research to aid the development of a regulatory position for post-CRBR LMFBRs, as discussec in Saction 3.9.1.

(g) We recommend an increase of $1.0 million for Decision Unit 10, Waste Management, chiefly to restore several of the programs that were cancelled or reduced in scope to provide funds for Semiscale M00-5, as discussed in Section 3.10.1.

4.2 Fiscal Year 1985 For FY 1985, we have proposed increases in funding for some Decision Units, corresponding generally but not in all cases to those recommended 14

f for FY 1934.

However, we have proposed no offsetting decreases, with the result that the total budget is somewhat greater than that proposed.

We are not at all comfortable with the proposed rather significant decrease in funding for. FY 1985 as compared to FY 1984.

Although some of the existing programs will be completed or greatly reduced in size as research objectives are reached, it seems highly likely that new questions will l

arise between now and the beginning of FY 1985. Unless these are as dra-matic as the TMI-2 accident, it would seem more desirable to budget for l

contingencies or for "new programs" rather than having to seek a supple-mental appropriation.

15

L i

TABLE 1 4

l OFFICE OF NUCLEAR REGULATORY RESEARCH PROGRAM SUPPORT BUDGET FOR FISCAL YEARS 1984 AND 1985 (DOLLARS IN MILLIONS) 4 FY 1984 FY 1985 I

ACRS ACRS PROPOSED RECOMMENDATIONS PROPOSED RECOMMENDATIONS 1.

REACTOR AND FACILITY

40. 5 40.5 42.8 42.8

{

ENGINEERING 2.

FACILITY 16.8 18.3 17.1 18.6 OPERATIONS 3.

THERMAL HYDRAULIC 27.5 27.5 22.6 22.6 TRANSIENTS i

4 SITING AND HEALTH 11.0 10.1 11.7 11.7 j

5.

RISK ANALYSIS 19.3 22.3 22.2 25.2 I

6.

ACCIDENT EVALUATION 45.4 39.8 38.6 38.6 AND MITIGATION 7.

LOSS-OF-COOLANT 10.5 10.5

9. 2
9. 2 ACCIDENTS t

8.

LOFT 17.5 17.5 10.0 10.0 9.

ADVANCED REACTORS

9. 5 10.5 8.5
9. 5 10.

WASTE MANAGEMENT 11.9 12.9 12.3 13.3 TOTAL 209.9 209.9 195.0 201.5-i i

17 i

-x- - -. -- - -

---,m,-.

1 APPENDIXES l

19

APPENDIX A REFERENCES L

{

1.

Advisory Committee on Reactor Safeguards, U.S.

Nuclear Regulatory Commission, " Comments on the NRC Safety Research Program Budget for Fiscal Year 1983," NUREG-0795, July 1981.

2.

U.S. Nuclear Regulatory Commission, " Unresolved Safety Issues Summary,"

NUREG-0606, Vol. 3, No. 2, dated May 15, 1981.

3.

Advisory Committee on Reactor Safeguards, U.S.

Nuclear Regulatory Commission, " Review and Evaluation of the Nuclear Regulatory Commis-sion Safety Research Program For Fiscal Year 1983 - A report to the 1

Congress of the United States of America," NUREG-0864, February 1982.

4 4.

Letter from P.

G.

Shewmon, Chairman, Advisory Committee on Reactor Safeguards, to W.

J. Dircks, Executive Director for Operations, NRC,

Subject:

Control of Occupational Exposures, dated May 12, 1982.

5.

Memorandum from R. B. Minogue, Director, Office of Nuclear Regulatory Research, to R.

F. Fraley, Executive Director, Advisory Committee on Reactor Safeguards, "262nd Meeting of the ACRS - Actions, Recommendae tions, and Requests," dated May 27, 1982.

?

21 i

+-

APPENDIX B GLOSSARY ACRS Advisory Committee on Reactor Safeguards CCTF Cylindrical Core Test Facility CRBR Clinch River Breeder Reactor DOE Department of Energy FRG Federal Republic of Germany FY Fiscal Year LLW Low Level Waste LMFBR Liquid Metal Fast Breeder Reactor LOBI Loop for Blowdown Investigations (Italy)

LOCA Loss-of-Coolant Accident LOFT Loss of Fluid Test LWR Light-Water Reactor NDT Nondestructive Test NRC Nuclear Regulatory Commission NRR Office of Nuclear Reactor Regulation PBF Power Burst Facility PKL Primarkreislauf-Hydraulic Test Facility in Germany designed to model plant systems behavior during Loss-of-Coolant Accidents and Transients PRA Probabilistic Risk Assessment PTS Pressurized Thermal Shock PWR Pressurized Water Reactor 23

RELAP Advanced System Code used to model Loss-of-Coolant Accidents RES Office of Nuclear Regulatory Research ROSA-IV Rig of Safety Assessment (Japan)

SCTF Slab Core Test Facility SNUPPS Standardized Nuclear Unit Power Plant System SSMRP Seismic Safety Margins Research Program TMI-2 Three Mile Island, Unit 2 TRAC Transient Reactor Analysis Code UPTF Upper Plenum Test Facility 24

y7 U.S. DeUCLE AR REGULATORY COMMIS$3ON BIBLIOGRAPHIC DATA SHEET NUREG-0875

3. TITLE AN D SU8 TITLE (Aad Vodume Na, erwarer, sert
2. (Les e bleef Comments on the NRC Safety Research Program Budget for Fiscal Years 198A and 1985 3 RECIPIENT'S ACCES$10N NO.
7. AUTHOR (S) 5 DATE REPORT COVPLETED Advisory Committee on Reactor Safeguards

" July 1982

9. PERFORMING ORGANI2ATION N AME AND M AILING ADDRESS (tacr de 24a Code /

DATE REPORT ISSUED u

won 7H lTIAN Advisory Committee on Reactor Safeguards July 1982 US Nuclear Regulatory Comission s

a,,,, ue e s Washington, DC 20555 8 (Leave blank)

12. SPONSORING ORGANIZATION N AVE AND M AILING ADDRESS (laciudr I.o Codel PR m m E M RA M @
11. CONT R ACT NO Same as 9., above.
13. TYPE OF REPORT PE RICO COV E RE D (lactusare defeJ/
15. SUPPLEMENTARY NOTES 14 (Leave meal
16. ABSTR ACT COO words or less/

g Recommendations of the Advisory Cc pittee on Reactor Safeguards are presented to the Comissioners for their cons'ideration for FY 84 and 85 budget for the NRC safety research program.

V

17. KEY WORDS AND DOCUMENT AN ALYSIS 17a DESCRIPTORS 1

17b IDENTIFIERS /OPEN-ENDE D TERMS

18. AVAILABILITY STATEMENT
19. SE CURITY CLASS (This report) 21 NO OF PAGES Un cl a c c i fi c..-4 Unlimited 20 SECURITY CLASS (Thes page)
22. PRICE S

NKCpORM335 (7 77)

[

UNITED STATES s oucta ct ass ua.t NUCLEAR REGULATORY COMMISSION "5j" 'u s a g,-

g an 0"

WASHINGTON, D.C. 20666 riami,sa o e O

n. in OFFICIAL BUSINESS PENALTY FOR PRiyATE USE. 8300
  • ' s 1

i A,

o s.

a.a i i ~

,, e

. r s,

4 k

ki s r-j t

?

t

'6, n.

l, N

1 0

i i