ML20062H340

From kanterella
Jump to navigation Jump to search
Summary of 790830 Meeting W/Bnl Re Physics Technical Assistance Program
ML20062H340
Person / Time
Site: Crane 
Issue date: 09/21/1979
From: Dunenfeld M
Office of Nuclear Reactor Regulation
To: Kniel K
Office of Nuclear Reactor Regulation
References
NUDOCS 7910240458
Download: ML20062H340 (2)


Text

' ~~' (

me_ epR

. e.

[f..y jo UNITED STATES g

NUCLEAR REGULATORY COMMISSION a

3 E

WASHINGTON, D. C. 20656 e

,,,./

SEP 21197g MEMORANDUM FOR:

Karl Kniel, Chief, Core Performance Branch, DSS THRU:

Daniel Fieno, Leader, Reactor Physics Section, CPB/ DSS.h FROM:

Mary Dunenfeld, Reactor Physics Section, DPB/ DSS

SUBJECT:

BNL-DSS PHYSICS TECHNICAL ASSISTANCE MEETING ON AUGUST 30, 1979 M. Dunenfeld visited BNL on August 30, 1979 to discuss progress on the DSS Physics Technical Assistance Program.

(

J. Carew reported the results of analysis of the TMI-2 sour'ce range detector response. We have been attempting t4ericusate the large variation in source range detector response observed during the early part of the TMI-2 accident. The results indicate the sensitive factor is voiding in the downcomer region of the reactor. A report is available (addressed to 0. Fieno, from J. Carew, dated August 28,1979) for anyone interested in further details of this work.

D. Diamond reportad the pronress made by S. Cheng on analyses being performed with ME"IN. A report is being written covering the BUR calculations and the rod ejection calculations performed by J. !ierczip before he left BNL. The BHR rod drop calculations are not ouite complete, as another case is in preparation which uill try to duolicate nore exactly the 2 dimensional TWIGL reference case with which the 3 dimensional MEKIN case will be compared.

/ ~

A. Aronson reported that earlier problems in operability of the DWARF code have been solved. We have been modifying DWARF to enable use of an axially detailed model for EOL load follow analyses. This unfortunately makes DWARF run much slower than before.

In retrospect, it seems it would have been wiser to modify NODE to do these calculations: a proposed activity for FY 81 is to program all the necessary searches into SIMULATE, which will replace N0DE. The searches are on baron concentration, axial offset, control rod position, etc.

The BWR rod drop calculations mentioned above are not finished because they are awaiting completion of programing of revised reactivity edits in MEKIN. Also programing changes which allow variable specific heat and thermal conductivity in the fuel have not been tested. These efforts should be completed shortly.

Contact:

M. Dunenfeld, x27577 7910 2 4 0 + 5 7

l l

M. Todosow reported the results of the first load following cases performed with the modified version of DWARF. These cases duplicated I

three BOL cases that had been done by A. Buslik a few years ago. The results are essentially identical. This constitutes part of the check-out of the modifications to DWARF. The other part consists of comparing NODE and DWARF unrodded power distributions with and without temperature feedback. A 4th order polynomial fit of the cross sections with temperature for DWARF has provided excellent agreement in these power shapes.

Therefore, it is considered that the modified code is checked out.

Running of the load follow cases for the EOL constant axial offset control and power distribution control analyses is now in progress.

It is probable that this project will not be completed this fisal year, as scheduled, and will run over at least two months in FY 80.

(

L. Eisenhart reported on the details of how he is setting up a system for generating cross sections for use in full core 3 dimensional kinetics calculations. He, and it. Todocow, also reported on the visits of Radkowsky and Rothenstein to BNL this suniner, and their discussions of the Radkowsky work on the effect of fission products on the Doppler Coefficient.

These discussions again point to the need for additional work to show if there is any reduction of the Doppler in the presence of fission products.

D. Cokinos reported on the status of generation of cross sections for the Ouad Cities reactor. The simulation oives better acreement with data 'for center fuel locations than the core edge. This is usually the case for most power distribution calculations in the absence of more sophisticated treatment of the core boundar.ies.

,l Y'l.,c.s.hf l I M. 'Dunenfeld t

Reactor Physics Section Core Performance Branch Division of Systems Safety cc: See attached distribution m

~

_ _ _.. -