s 4

REVISED DATA FOR APRIL 1982 REPORT (Ref. LAC-8259)

J OPERATING DATA REPORT DOCKET NO. _50-409 DATE _05-05-82 COMPLETED BY __G.R.GADOW TELEPil0NE - 608-689 2331 s

OPERA TING STATUS

1. Uni Narne: l.a Crosse Boiling Water Reactor 1

Notes

2. Reporting Period: 0001, 04-01-82 to 2400. 04-30-82 3.1 icensed Thermal Power (MWt):

165

4. Nameplate Rating (Gross MWe):

65.3 50

5. Design Electrical Rating (Net MWe):
6. Maximum Dependable Capacity (Gross MWe):

50 6

48

7. Masimum Dependable Capacity (Net MWe).
8. If Changes occur in Capacity Ratings (Items Nombd 3 Through 7),Since Last Report.Gise R.none r

s t

i 4

9. Power Lesel To Which Restricted,if Any (Net MWel:'.,

1

10. Reasons For Restrictions. If Any:

i r

s I t.

,A r

t i t x

s

\\ ~ This Month 4

Yr..te Date

. Cumulaine I1. Ilours In Reporting Period 719 2879 109,538

12. Number Of floun Reactor Was Critical 197.9 1796.6 73,070.2 0

0 478

13. Reactor Reserve Shutdown flours

/

14. Ilours Generator On-Line 197.8 1706.2 67,393.4 15 Unit Reserve Shutdown Ifours

- 0 16 Gross ThermalIncrgy Generated (MWI) 23,639.8

_0_

79 212,692.4 9,208,481.1 17 Gross Electrical Energy Generated (MWill 6601

._52.,143 3.749.001

__ _,s.

18 Net Ekctrical Energy Generated (MWil) 5796 54.397 2,542,389 u

19. Unit Senice Factor 27.5 59.2 61.5
20. Unit Availability Factor 27.5

' (59.2 61.6 s

3 l

21. Unit Capacity Inctor (Using MDC Nes) 16.81c, s 39.4 43.4 16.1 37.8 46.4 l
22. Unit Capacity Factor (Using DER Net)
23. Unit Forced Outage Rate 0

27,i6 8.1

24. Shutdowns Scheduled Over Nest 6 Months (Type. Dats and Duratirm of kach):

Refueling in Progress - Commenced Apiil 9, 1982.

Exoncted Dora tion i <: 12 Wonk(.

\\

25. II Shut Down At End Of Report Period. Estimated Date of Startup-July 6, 1982
26. Units in Test Status (Prior to Commercis Operation):

Forecast Ac hies ed s x

f INIII\\L CRillCALITY INITI A'L ELLCTRICITY j

l CostvCRO ti. Ort:R s rioN t

l I

8208120310 820707 PDR ADOCK 05000409

\\e l

R PDR

' ! i,

\\

I 50-409 UNil SIIU1 downs AND PowLa Rt!)UcIloss IXX KE T NO.

'"O " K UNIT N A%f E DATE UD-UD-d2 ntroniyoNTI, APRIL 1982 COMPLETED BY 6.n.bnLun TELEPIIONE oub-ob9-c4jl 1

=

- m.5 7

L 55

?

-3 _E f lC"'

51 E *',

Cause A C. ore,anc Dd ' #

I.

2?

,4 2 i er I 'c ut

7

{?

A6 u..n s..

3. E
2 j di j RcP nl r E0

}'

Prevent Recurrente d

l 82-07 04-09-82 S

521.1 C

1 t1A t1A flA SCHEDULED REFUELIt4G OUTAGE.

I 1

EXPECTED DURATI0t1 0F 11 WEEKS.

l l

l l

e.

mm MM

'O <

OH N Cn 8MC

^C 0 4 2

3 4

"i >

l !. cJ Reason M et h.ed I.sinhit G. Instru o.uis s

s L bcJ uf ei!

A E luipment Failure ti.splani)

! Manual for P.eparation of Data t* o 13 Maintenan,e or Test

' Manual S r.nn I.nin Shects t.n 1.isensee

$,,N c-aanen,,,

u.. t.. n.i,. s.,..,

i,c,,, ace. a i a i rac i u ni <.

D Regulat..rs Rest eisti..n 4-41 lece el splaini 01r 1 i m ac l -Operator Tranung A i secose I wninati..n 11 AJnu nnt rat ne

  • t-'

G Operati..n 11 :.. Il spl.nn t i sintut I % nec % o, c

~

i.

's ll Othee il sp'ain i

[