Text
,
'
.
.,
',
.
.
!
Dockets Nos.:
50-072/90-01
50-407/90-01
,
License Nos.:
R-25
>
R-126
Dr. James J. Brophy
Vice President of Research
University of Utah
Salt Lake City, Utah 84112
Gentlemen:
This refers to the inspection conducted by Messrs. B. Murray and J. B. Nicholas
of this office and M. M. Mendonca of the Office of Nuclear Reactor Regulation,
during the period September 24-28, 1990, of activities authorized by NRC
Operating Licenses R-25 and R-126 for the University of Utah's AGN-201 and
TRIGA reactors, respectively, and to the discuasion of our findings with you
!
and other members of the university staff at the conclusion of the inspection.
Areas examined during the inspection included reactor operations, radiological
controls, emergency preparedness, nuclear _ materials safeguards, and physical
security programs associated with the university reactor facility. Within
these areas, the inspection consisted of selective examination of procedures
and representative records, interviews with personnel, and observations by the
inspectors.
The inspection findings are documented in the enclosed inspection
report.
During this inspection, it was found that certain of your activities were in
violation of NRC requirements. However, in accordance with 10 CFR Part 2
Appendix C,Section V.A. of the NRC's Enforcement Policy, no citation is being
issued for the violation described in paragraph 14 of the enclosed inspection
,
l
report. No deviations were identified.
We have also examined actions you have taken with regard to previously
<
identified inspection findings. The status of these items is identified in
paragraph 2 of the enclosed inspection report.
There are a number of open items listed in paragraph 3 of the enclosed
inspection report that identify commitments made by you and your staff that
l
will be review 3d at a future time by NRC inspectors.
RIV:RPEPS
HQ:NRR
C:RPEPS
PD:P P
0:DRSS
- BNicholas:nh MMMendo
f
- BMurray
SHWei
ABBeac
3
i
/ /90
- Previously con llurred./ib/90
- n
/ /90
9A6/
o/t6/90
)
c
'
Y
"by
Nfy
.
y
9011280359 901116
ADDCK 05000072
O
PNV
-
0
?
,
"'-L
s)
,
!
'.
.
University of Utah
-2-
Should you have any questions concerning this inspection, we will be pleased:to
discuss them with you.
Sincerely,
hM
A.. Bill Beach, Director
+
Division.of R8diation Safety
-and Safeguards
Enclosure:
Appendix - NRC Inspection Report
j
50-072/90-01
50-407/90-01
,
cc w/ enclosure:
University of Utah
ATTN:
K. J. Schiager
r
Radiation Safety Officer
i
Radiological ~ Health Department
'
100'0rson Spencer Hall
Salt Lake City, Utah 84112
.
University of Utah
ATTN: Gary Sandquist, Director,-NEL
Merrill Engineering Building
l
Department of Mechanical Engineeving
'
St.lt Lake City, Utah 84112
University of Utah
ATTN:
D. K. Gehmlick, Reactor Administrator
Merrill Engineering Building
-t
Department of Mechanical Engineering
Salt Lake City, Utah 84112
University of Utah
ATTN:
K. C. Crawford, Reactor Supervisor
Merrill Engineering Building
>
Department of Mechanical Engineering
Salt Lake City,-Utah 84112
Radiation Control Program Director
Bureau of Radiation Control
Dept. of Health-
P.O. Box 16690
Salt Lake City, Utah 84116-0609
,
.
>
!
'.
,
1
-
University of Utah
-3-
'
bec to DMB (IE01)
i
bCC:
'
R. Martin
- B. Nicholas, RPEPS
A. Adams, NRR Project Manager
- B. Murray, RPEPS
- DRP
Lisa Shea, RM/ALF
- RIV File
- MIS Coordinator
- RSTS Operator
- DRS
- A. B. Beach, DRSS
- L.-Yandell, DRSS
- RPEPS-DRSS
M. M. Mendonca, NRR
,
- w/766
,
4
i
k
.
.
9