Text

VIRGINIA E LE CTRf C AND FCM R COMPANY Surry Power Station P. O. Box 315 Surry, Virginia 23883 Serla1 fio:

82-056 AUG 3 13 S 3 Docket flo:

50-280 N

License flos :

DPR-32 z

i Mr. James P. O'Reilly Regional Administrator Office of I r, E, USf4RC Region ll p

101 Marietta Strcet, Suite 3100 g

Atlanta, Georgia 30303 r-J c-

Dear Mr. O'Reilly:

Pursuant to Surry Power Stat ion Technical Specificat ions, the Virginia Electr ic and Power Company hereby submi ts the following Licensee Event Reports for Surry Unit 1.

Re po r t flumber Applicable Technical Specification 81-047/03X-1 T. S. 6.6.2.b(2)

T. S. 3.1.D.4 82-049/03X-1 T. S. 6.6.2.b(2)

These reports have been reviewed by the Stat ion fluclear Saf ety and Operat ing Committee and will be reviewed by Safety Evaluat ion and Control.

Very truly yours, 5

J. L. Wilson S ta t ion Manager l

Enclosures cc:

Mr. Richard C. DeYoung, D i r ec to r (3)

Of fice of Inspect ion and Enforcement Mr. florman Haller, Director (3)

ED ORICl b

  1. DEbI Of fice of Management and Program Analysis

.,,. > nu Ib 820012o110 020eca