ML20062E544

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 82-02 Re Degradation of Threaded Fasteners in Rcpb.Action Item 1,procedures for Threaded Fastener Practices,Will Be Implemented Prior to Action Item 2 Insp
ML20062E544
Person / Time
Site: Millstone, Haddam Neck  File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 07/28/1982
From: Cagnetta J, Counsil W
CONNECTICUT YANKEE ATOMIC POWER CO., NORTHEAST NUCLEAR ENERGY CO.
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
REF-SSINS-6820 A02544, A2544, IEB-82-02, IEB-82-2, NUDOCS 8208100142
Download: ML20062E544 (2)


Text

_.,

?

  • "*"' ' "" "
  • S * '*" 5 "'

8""" C="* c" c"'

NORTHEAST IFFII.ITIES 5

C '." Z ', T % IO T ~

f84froNcONNECTICUT 06101

';=:::,'"O'ZT ""~

a m m e91$

L L

J ; %.ll L',"::" ? : ::

July 28, 1982 Docket Nos. 50-213 50-336 A02544 Mr. Ronald C. Haynes Regional Administrator Region 1 Of fice of Inspection and Enforcement U.S. 1:uclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406

Reference:

(1)

I&E Bulletin No. 82-02 dated June 2, 1982.

Gentlemen:

Haddam Neck Plant Millstone Nuclear Power Station, Unit No. 2 Response to I&E Bulletin No. 82-02 In reference (1), Connecticut Yankee Atomic Power Company (CYAPCO) and Northcar,t Nuclear Energy Company (NNECO), were requested to take certain actions with respect to degradation of threaded fasteners in the reactor coolant boundary of the Haddam Neck Plant and Millstone Unit No. 2, respectively.

Confirming a telephone conversation between the Technical Contact identifed in reference (1) (W. J. Collins) and my staf f (W. D. Bartron) on July 16, 1982, regarding clarification of the requested due dates for the I&E Bulletin No. 82-02 Action Items, it is our understanding that Action Item 1 is to be completed prior to the performance of Action Item 2, but not necessarily before the completion of Action Item 3.

That is, f

the Action Item 1 procedures for threaded fastener practices shall be implemented prior to the performance of the Action Item 2 inspections.

The report of the completion of Action Items 1 and 2 shall be submitted within 60 days following the completion of the outage during which Action Item 2 was performed. Action Item 3 shall be completed and a report submitted within 60 days of the data of the bulletin.

8206100142 820728 1( q PDR ADOCK 05000213 G

PDR 2

e2-If you have any questions in this regard, please contact me.

Very truly yours, CONNECTICUT YANKEE ATOMIC POWER COMPANY NORTHEAST NUCLEAR ENERGY COMPANY as. s.(Lclf

'W. G. Counsil Senior Vice President By

//h

/P. Cagn ta ice Pres ent Nuclear & Environmental Engineering

$-e n

(J G

i t

i I

i 1

-