ML20062D871

From kanterella
Jump to navigation Jump to search
Forwards Reactor Containment Bldg Integrated Leak Rate Test, for 820514-19 & Related Appendices Describing Type a Test,Per 10CFR50 App J Requirements
ML20062D871
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 07/28/1982
From: Holyoak R
COMMONWEALTH EDISON CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20062D872 List:
References
NUDOCS 8208060248
Download: ML20062D871 (1)


Text

0 T

~#

/ Commonwealth Edison LaSalle County Nuctur Station 1 Rural Route #1, Box 220 )

g v Marseilles, filinois 61341 i x Telephone 815/357-6761 July 28, 1982 Director of Nuclear Reactor Regulation U. S. Nuclear Regulat,ory Commission Washington, D.C. 20555

SUBJECT:

Reactor Containment Building Integrated Leak Rate Test LaSalle County Nuclear Power Station Docket No. 50-373, NPF-11, Unit 1 Enclosed please find the report " Reactor Containment Building Integrated Leak Rate Test, LaSalle County Nuclear Power Station, Unit One, May 14-19, 1982" and related appendices describing the Type A test. The performance of this test was witnessed and inspected by representatives of the NRC Region 111 Office.

This report is submitted to you in accordance with the requirements of 10CFR50, Appendix J, Section V.B.1. The information contained in Appendix A of this report is intended to comply wi th requirements of 10CFR50, Appendix J, Section V.B.2.

According to 10CFR50, Appendix J, Section 111.D., the next Type A test will be performed on Unit One during the second refuel outage. This shut-down is scheduled for 1984.

Very truly yours, COMMONWEALTH EDISON COMPANY LASALLE COUNTY NUCLEAR POWER STATION

,-~~

N N

H. Holyo cooI p

ation S erin dent RHH/RK/dJp Attachment K0 fj3 PDR

.. - -