[E%Mf f 7E @Loceswn og dtjere*
M E /#.DDE EE3 ( f erlude N ATION AL POLLUTANT D12CH AM2 ELIMIN ATffiN OYOT5M ( APDf.3)
IDFFl AN'FOWal r ecmtp Aarr.1/
OtSCH ARGE MONETomNG REPORT (Dun)
OMB No.1.%8. ROO e ns _ _ _A RKAES A A_') P.DHER _A_M D2_ ICL_ _ _ _
'2 m
'im A oDR Em_J)(_ C A VAN AU GH_ lII_ _ _ ___ _ _ _ _
AR0001392 001
__ ___APJLECLEABmP_Q_ AQX_551______
"E"""
"'""E"
._ _ _ _L M
3 BJmL_____J_
Mo~iToai~c rEaico
^'
ra curtty_ _ --
01 7 91 62 04.! 3J1]
041 i4:5[ gy 7: sin
. TOC ATiOw-
$2 rao" an m ~d se aA ip.
em m NOTE: Read instructions t>efere completing this form.
( J Card Onl) )
QU ANTITY OR LOADING (4 ( erd Ogly )
QU ALITY OR CONCENTR ATION PARAMETER (46 13)
(3441)
(3841)
(46-31)
(3441)
NO
"'O','*
SAMPLS g
p ANA o...
AVERAGE M AXlMUM UNITS MINIMUM A%ERAGE M AXIMUM UNITS g
g, S A M PLE Once Through Cooling MEASUaEMENT 591.6 1143.5 NGD 0
Cont.
Recor Water (001)
PERMIT Flow R Ec uiR EM ENT 1123 1145 Cont.
Recor S A M PLE M E ASuREM ENT 62.9 69.2 0F 0
Cont.
Recor Temperature PERMIT R EoUiR EM E NT 105 110 Cont.
Recot S AM PLE Free Available MEASuac"EN' O.904 3.76 Kg/ day N/A
.044 0.13 ng/l 0
2/7 Grab Chlorine NOT REouiREMENT 71 181 3PECIFIED 0.2 0.5 in Grab SAMPLE MEASUREMENT PERMlT R EQUIREM ENT S AMPLE MEASUREMENT PERMIT R EQ UIR EM ENT Om A S AM PLE N O 3.
MEASUREMENT gQ 00 PERMIT NO R EQUIREM ENT mOO S AM PL E g
MEASUREMENT g
OO PER MIT 4Q REQUIR EM ENT 04 (D
N AME / TITLE PRINCIPAL EXECUTIVE OFFICER I CE NM W UNOLR PENA.TY OF L A Ww THAT e HAvt PE RSON ALL Y E R AMtNED TELEPHONE DATE Og AND AM F AMaU AR wtTH THE INFORMATION SuBuiTTED ME REsN ResPONs o based NO AN
~~T~. M. Levine E roR
,c< T-Os.r No vo,r utvtuns ~Mm A n,a,M.Tn o.NFO.M A T,0N
'/
'w Mv eeuRv m a.e -
~,0,~ A T oM T-t su Om uNG T-E
..//
General Manager
.s, iC ANY T~ue Accuaarr A~o C = Err i AM A* ARr T~Ar T-< ae Apr sc k
N,,r Pt' N AL T it,$, FORANo ~,TTtNG su'Nr'*MATCN s,NCL,UCNNG,,ogiuREOri.RINCiPALEXECuTivE 501 964-3100 1982 07 14 suMM*
FAtsf
.,.. ass eioTV e
,N
.R.sc-NT io usC co ANo 33Uc.c %1119 *l%iatters andre these staturre mas ena lseir-fuere up seu $1.. nte l DA4 TYPED OR PRINTED
- */ "'"'*"***""Ph*""""
d b '" "' * "'"*' A *
- d i "* '
FFICER C4 AUTHORIZED AGENT NUMBER YEAR MO COMMENT AND EXPLAN ATION OF ANY VIOL ATIONS ( Artrrrm e ml tt.a hments ##rre) 2P A Fpem 33201 (Rev.10 79) PREVIOUS EDITION TO BE USED (REPLACES EPA FORM T-40 WHICH M AY NOT BE USED.
PAGC 1 OF
[
UNTIL SUPPLY IS EXH AUSTED
PE.RMITTEE MM E/ADME33 fl9d8de N ATION AL POLLUTANT Dl!CH ACGE ELIMIN ATISH CY2 TEM (NPDES) rorm Affrontd r ada>.samef twnws af discrerrs DISCH ARGE MONITORING REPORT toMA)
OMB.%'.133. ROO ms__JEXAGAs_t_ogg1MGM._qo
<2 im
<rm g ORE _SS W M.1&YAMAU_9 H_ J LI_ __ _ ___ _ _ _
AR0001392 002
_ _ _ _ 3BK lyCLI&B 4_Q_101_55_L _ _ _ _ _
'""**a'~"-"-
i__ __MML5_MU AB 321L 3_ _ __ __ __4_
e~IToai~c eCaioO tssnr tu_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
vEAn MO DAv vEAn i MO_
OAv
~~LOCATroN~~
62 04 01 7 91 821 04 30 R U '"'^ % *
- 3's NOTE: Read instructions before completing this form.
co i. ru n tr' '$'
( f Card Only) QU ANTITY OR LOADING (4 Card Only)
QU ALITY OR CONCENTR ATION antoutNcv PAR A M ETER (46-JJ)
{$4 Al 3 (1843)
(46.33)
(3441)
NO.
g g u pgg gp EX TvPE
,, w )
..L,,,,
AVERAGE M AXIMUM UN 4 TS MINIMUM AVERAGE M AXIM UM UNITS g,
S AM PLE Esti-Cooling Tower Blow-3.5 5.76 MGD 0
Daily mte "E^*u"E"5"'
down Water (002)
~
Esti-
,.E R M,7 Flow
" Eau iR EM E"'
20 35 Daily mte S AM PLE Free Available MEASUR m ENT 0.025 0.032 kg/ day N/A 0.1 0.1 mg/l 0
1/7 Grab Chlorine NOT
,E,,M,7 R EauiR EM E"7 15 38 SPECIFIED 0.2 0.5 1/7 Grab S AM PL E pil 7.6 N/A 8.4 pli 0
17/30 Grab
"'^*""*"5"'
NGr PERMIT 6.0 SPECIFIED 9.0 1/7 Grab _
S A M PLE e4 E A S U R EM EN T PERMIT REQUIREMENT S A M PLE M E ASUREM ENT PERMlf R EQUlR EM ENT SAMPLE MEASUREMENT PERMIT R EQUIR EM ENT S AMPLE MEASUREMENT PERMIT R EQUIR EM ENT N AME/ TITLE PRINCIPAL EXECUTIVE OFFICER I CERTSY UNDER PE NA L T Y OF LAW THAT I MAVE PERSONALLY ER AMINE D TELEPHONE DATE AND AM F AMILIAR WITH THE INFORM ATeON SUBM'TTED MEREIN AND BASED E
/
- I. M. lev 1ne ON "v e,utnRv Or TwmE >NDiviDuAts iMw D ATELv REsPowStE rOR OBT AiNsNG THE INFORMATeON, TETE TH.E INFOR,M ATIO.N 1j-4 BEL IE VE SUBMITTED General Manager A~D CoM AM A m T AT T ERE A,E
's 'auE. Accu ATE N#81C ANT PF N ALT tE S FOR SLftM'TTfMG FALSE INe ORMatsON #NCLUDtNG
_ yw SIGe+AT URE OF PRINCIPAL EXECUTIVE 501 164-3100 1982 07 14 THE POMOLIT Y Or reNE AND IMPR60NMENT CEE 18USC 91001 AND 3 3 u SC % 1319 r renaltern under thene erotures me, anclude (mee op ta $1ojun j
'A
^
TYPED CR PRINTED
- "'< ar ** "**m **Pr8a.m menr uf fortuovn 6 montha and a wre re s 9FFICER OR AUTHORIZED AGENT NUM BER YEAR MO DAY C DE COM M EN T AN D EXPLAN ATION OF ANY VIOL ATION S ( Melternd t all at'sa hmteris here)
C Pr.. w 33201 (Rev.10 79) PREVIOUS EDITION TO BE USED (REPLACES EP A FORM T.40 WHICH M AY NOT BE USED.)
PAGE 7 OFr UNTIL SUPPL e R$ EXHAUSTED
rhMITTEd N4ME/ADOKr@il (InduJr N ATION AL POLLUTANT Of7,CHAACE ELIMIN ATION CVSTEM ( APDIS) form AppFEntd Ienkt> hametLm erwn #1 diferen DISCH ARGE MONITORING REPORT (DMR)
OMB.%r.158 - R007 m u _ _ _A RKMB AA_')RO F KR _& _kIGBT_ IQ_ _ _ _ _
e io
7 '$>
A D'Du.._JfM__QUANAUEF_IU_ __ _ __ _ _ _ __
APooo1392 003
_ _ _ _ _A BJLNJ C L it 4B =.P_Q ARK _ML _ _ _ _ _
'""'"o' ~"- '"
_ _____L11TLE_RQCE_AR 7211L_ _____3_
Mo~iToai~G rEaioo
! o"
">a "o
i o"
usmar_____________________
"a"
-o
..__0 L 0 1 M. _ 6 2 _ 041 30_
3
" _8 2
_ LOC 2TanM___ ____
em mm ai m g mm am m em NOTE: Read instructions before completing thin form.
l(J Card Ont)) QU ANTITY OR LO A DIN G (4 Card Only)
QU ALITY OR CONCEN TR ATION PAR AM ETE R (4M 3)
(34 6f t (1847)
( 4Ml)
(34 4 I)
NO.
,,u,,,,
AVERAGE M AXIM UM UNITS MINIMUM AVERAGE M AXIM UM UNITS gg gy,
.g SAMPtE Total-Oily Water Separator
.1054
.2034 MGD 0
Daily ired Discharge (003)
PERMIT Total-Flow
"'"'"'"""7 0.2 0.5 Daily ired Total Suspended "E^*""'"'"'
4.11 4.99 Kg/ day N/A 8.64 15.0 mg/l 0
1/7 Grab
' solids NOT PERM 7 R EQUiR EM E"7
~23 76 SPECIFIED 30 100 1/7 arnb m
S AM PLE 011 and Grease M E ASU R EM ENT 7.87 14.73 Kg/ day N/A 12.47 19.2 mg/l 0
1/7 3 rah PERMIT NOT
"'"'"'"""7 11 15 SPECIFIED 15 20 1/7 3 rah _
SAMPLE pil 6.5 N/A 7.3 pli 0
1/7 Grab NGI' PER MiT
"*"'"*"'"7 6.0 SPECIFIED 9.0 1/7 3 rah S A M PLE MEASUREMENT PERMIT REQUIREMENT SAM *LE MEASUREMENT PERMIT R EQUIR EM ENT SAMPLE MEASUREMENT PERMIT R EQUIR EM ENT N AME/ TITLE PRINCIPAL EXECUTIVE OFFICER I CE RTsF V UNDER PENALTY O.
(An THAT I HAVE PERSONALLY E R AMsNED TELEPHONE DATE AND AM F AMILIAR w'TH THE INFORMATION SUBM11TED HEREIN AND SASED ON MV #NQUtRY OF THfME holviOUAt $ 8MMEDI A TEL Y RESPONS8BLE FOR j
OBT A'NeNG THE INFORMATaON. I BEL IEV E THE SUPMtTTED INFORM ATION J, y, {pyjpg t% TRUE ACCURATE AND COMPLETE I AM A w apf THAT THERE ARE Sir. -
/
[ [
jg f-htFIC ANY PE N ALTIE S f'OR SURMITTING FALSE
- NF ON M ATION sNCLUDiNG
\\ ~-
General Manager e:GN,A4uRE OrVRiNCiPAL EXECUTIVE 501 164-3100 1982 07 14
'-< "o**"
o' * *c '"o '"""5o~"ca' 5' ' '
- u s c * 'oo' ^~o 33USC 11Y 9 tPrnahare under theer araterrn mes unlaJe fence up to Stosuus A
A TYPED OR PRINTED
- 'l ** mamamam emmeinnient of kruwn 6 m nlha mad.S trars '
DFFICER OR AUTHOHlZED AGENT NUM B ER YEAR MO DAY COM M EN T AN D EX PL AN ATION OF ANY VIOL ATIONS t Rrferrive vil wit *H hments herr)
P A f orm 33201 (Rev. 10 79) PREVIOUS EDITION TO BE USED (REPLACES EPA FORM '-40 WHICH M AY NOT BE USEC.
PAGE 3 OF 5
UNTIL SUPPLY IS EXH AUSTED
E 3QlyTgg N'AM E /ADDAECg (fach,Jr N ATION AL POLLUTANT DISCH A2GE ELIMIN ATION SYSTEM l A PD7..$)
ION Afffold Iealets hame/Lmeswn of Jderent)
OSSCH ARGE MONITORING REPORT (DMR)
OMB Ne.135. R00,.
e w.x__JBXAUAA_lMI!LE_kIGM.IO
'2 ' *
7 '
- WM__qtyAMAU_Gillu_. _ _ _ _ _ _ _ _ _
AR0001392 004 ADDRE..
____JBJULUCLE&B =P_L EQX J1L__ _ __ _
l _ _ __LIIILE_AQCE_AE_72211__ _ _ _ __4_.
McNiroai~o rEaioO "o
I L'""!
" l r e tn _ _. _ _ _ _ _ _ ___._ _ _ _ _ _ _ _ _ _
.. 8 2._ 0 4 L O 1 T M L _ 8 2 L O 4 L 3 0J
' LOC _m au_
<.w sn a2 n,
<n is, g min
<n.w,
<.m n, NOTE: Read instructions before completing this form.
(f ( erd Only) QU ANTITY OR LO A DING Id CarJ Onip )
QU ALITY OR CONCENTR ATION
' *g,o"r,'
(J441)
(33Jf)
(46-33)
(5441)
NO-SA" N TYPE EX g g,g
/,
('2 ")
AvERAoE M AXiu uM UNITS minimum AvERAcE M AXiM UM UNITS SAMPLE Each Total-
"'^*""'"'"'
Low Volume
.088131
.341390*
MGD 1
Relensei~ed Waste h'ater (004)
PERMIT Each Total-Flow O.15 0.3 nelense ima SAMPLE Total Suspended 5.1 7.1 Kg/ day N/A 11.2 25.3 mg/l 0
1/7 Grab
"'^*""E"'"'
Solids iW PERuiT 17.1 N/A SPECIFIED 30 100 1/7 Grah S A M PL E
""^*""5"5"'
Oil and Grease O.3 0.5 Kg/ day N/A 0.9 3.0 mg/l 0
1/7 Grah PERMIT N0f
""*"'"E"""7 8.5 N/A SPECIFIED 15 20 1/7 Gralt
- AMPLE pil 6.0 N/A 9.0 pil 0
1/7 Grab PERMIT NOT 6.0 SPECIFIED 9.0 1/7 Grah S A M PL E MEASUREMENT-PERMIT R EQUIR EM ENT S AM PLE MEASUREMENT PERMIT R EQ UIR EM ENT SAMPLE MEASUREMENT PERMIT REQUIREMENT N AME/ TITLE PRINCIPAL EXECUTIVE OFFICER I CERTTY UNDER PE N ALTY Or LAW THAT I HavE PE RSONAL LY Ea AMtNED TELEPHONE DATE AND AM r AMst r AR W TH THE INFORMAYiON SUBMiTTTD HERCIN AND BASED
]*
pjg
.Or THO%E IND.iveDU AL S RE SPONrORM AYiON
/
ON MV #NQUsRY iMMEDe A TE L Y N5iBLE FOR g
Nr oRM ATiON swEvE w runMiTTr D Oni A*iNo THE General Mana8er
'5,ric" ANT ^cc""^s ^r' orc o"uo*M.TT,~c"" * ^" **^"",ORMAT,0N'" '"'"5 Ne"t uD.~o M/4/ j
^t 5*
> w~ -
~
ri N A<T,C s
rALsE N
501 964-3100 1982 07 14 THE N BeuTY & mf ANO IMPR@ MENT SEE IB UGC 9 1001 AND Si f/AT U R E F PRINCIPAL EXECUTIVE 33U%C b13t9 rivnetters under theer areterre me, vertens,e (mee a,p to $ Dpire
!bFFICER OR E
TYPED OR PRINTED 8"d*"****'""*P"*""*#"'"lN'"*^"**"'"**'"I8F"'**
AUTHORIZED AGENT NUMBER YEAR MO DAV DE COMMENT AND EXPLAN ATION OF ANY VIOLATIONS I Ma'le rem e a# assei hments Arre) 8Ref. CL-2048 PC Fom 33201 (Rev. 10 79) PREVIOUS EDITION TO BE USED (REPLACES EPA FORM v.40 WHICH M AY NOT DE USED.
PAGE 4 OFg UNTIL SUPPLY IS EXH AUSTED
7 ARKANSAS POWER E. LIGHT COMPANY FIRST NATIONAL DUILDING/PO. BOX 551/LITTLE ROCK, ARKANSAS 72203/l501) 371-4422 May 21, 1982 WILUAM CAVANAUGH, lll Senior Vice President Energy Supply CL-2048 Mr. Dick Whittington Regional Administrator United States Environmental Protection Agency Region VI First International Building 1201 Elm Street Dallas, Texas 75270
REFERENCE:
Arkansas Nuclear One NPDES Permit Number AR0001392
Dear Mr. Whittington:
This letter represents a noncompliance report as required by Part II, Paragraph A.2 of the above referenced Permit.
On April 28, 1982, the flow limitation (0.15 MGD daily average and 0.30 MGD daily maximum) for outfall 004, low volume waste-water, was exceeded due to a discharge on this date of 0.34 MGD.
All other parameters were within limits.
This violation was not detected until May 14, 1982, because flow accounting is performed monthly to accrue data for the Discharge Monitor-ing Reports.
This high discharge volume was related to the simultaneous start-up of both units which resulted in an ab-normally high number of releases for this outfall.
We are implementing administrative actions that will include a daily accounting of the volume released via outfall 004 and should prevent a recurrence of this violation.
Yours very truly, tL<At-~ 9 w
William Cavanaugh, III WC/DLS/ew cc:
Messrs.
J.
L.
Maulden C.
L.
Steel W.
G.
Coleman D.
L.
Swindle J.
D.
Jackson J.
M.
Griffin J.
Levine J.
Southall, Director i
Arkansas Department of
{
Pollution Control and Ecology l
F E:ttilT TE E, NA M E/ A DD%E20 @h lude N ATIONAL POLLUT A NT D17 CHARGE ELIMIN ATION SY3 TEM L APD/.5) rorNI ATPW fd
/ wal4 A.me/Lmsnm 41 discree')
DISCH ARGE MONITORING REPORT (DwR)
OMB Net IM - R00-
. ec___ARKMj AS P0HIH _&_kIGM.IQ_____
ofo
'3 7 '*
A_9mEm __H1 E MARAUSH_lII_.__ _ _____ _ _ _
AROM1192 005
_ _ _ _ _A RKJiU CR&B - P_Q_ BD X _551__ __ _ _ __ _
'""^aa"""'a
,._ _ _,_, _}h h
)Nb_____
MONITOMING PERICO I
TEAR MO DAY YEAR MO DAY }
EAGMTJ_ _ _._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -
04 0{
_} p g._) p M2C.AT.LON_
"(J C ard Only )
QU ANTITY OR LOADING (4 Card Only)
QU ALITY OR CONCE NTR AYlON F a t o,u t NC v g a u ptg PAR AM ETER (44-31)
($441)
( JS-43 )
(46J3)
(3447)
NO.
EK TYPE AN Atests I
I AVERAGE M AXIMUM UNITS MINIMUM AVERAGE M AXIMUM UNITS
,q p
,,41,,
(,, 7,,
bstk*
S AM PLE Sanitary Sewage "E^5u"E"'"'
.012600
.0210 MGD 0
Daily ute Discharge (005)
Esti-R EQ u iR E,.T
,ERu, ENT 0.025 0.1005 Daily ute Flow
" E^.A M PLE N/A 5.00 9.0 ng/l 0
1/7 Grab S
Total Suspended u"'"5"'
Solids NOT
,,,,,7 "E*"'"*"E"'
SPECIFIED 30 45 1/7 Grnb S A M PL E Biochemical Oxygen N/A 12.44 15.8 mg/l 0
1/7 Grnh "EAsuRE"'"'
Demand m
3.E,,,7 "E*"'"E"""'
SPECIFIED 30 45 1/7 Grab _
S AVPLE pil 6.2 N/A 7.3 pil 0
1/7 Grab "E"'"*"'
NUr PERMIT 6.0 SPECIFIED 9.0 1/7 Grah S A M PLE MEASUREMENT PERMtf R EQU,IR EM ENT S AM PLE MEASUREMENT PERMIT R EQUIR EM ENT SAMPLE MEASUREMENT PERMIT REQUIREMENT N AME/ TITLE PRINCIPAL EXECUTIVE OFFICER 6 CE RTsF Y UNDE R PENALTY OF LAW THAT I MAVE PERSONALLY E R AM6NED TELEPHONE DATE AND AM F AMtL TAR wtTH THE INFORM ATION SUBMf 7TED Mf REIN AND BASED ON My sNOUiRY OF TMO5E *NDV4 DUALS IM*4E3 A % Y Rf SPONSsBLE FOR
</,
OETT AihtNG THE INFOp*M A TION I BELIEVE THE SUBM'TTED ##ORM A TION g
'/Mema J. M. Levine
's Taut accuaa'< ^~o coma'r'E '
^M aaaat 'aa' ' tat aat
_ General Manager SI.N,iTURE OP PRiNCi,AL executive
'~<==*v oF r'~<
^~o *M'*So~Mc~r Src 'a u s c
- ioo' A~D cn1 oW&W _&h, 31 U SC 113 t 9 tPenaltern osader threr eretutre mas snela,nte [snee op to Sta. rite TYPED OR PRINTED eruf es meramam ampraaaament sV hrta**= 4 munths end S yrere J
/OFFVER OR AUTHORIZED AGENT NUMBER YFAR MO DA)
.A" A
c g
COMMENT AND EXPLAN ATION OF ANY VIOLATIONS t Refrrent e all afha hnstnff hr'el F
EP A Form 33201 (Rev. 10 79) PREVIOUS EDITION TO BE USED (REPLACES EPA FORM T.40 WHICH M AY NOT BE USED.
PAGE 5 UNTIL SUPPLY IS EXH AUSTED
9 hERMITTEE NAM E /ADOJtE2G tiarlevde N ATION AL POLLUTANT DitC H ARG E elf MINATION SYSTEM 4 NfDf 5, form Ap,*POWJ Enahp Name/Lmaswn sj dderent)
OtSCH ARGE MONSTORING REPORT (OMR)
OMB ho 1.4 - ROO
&M1__3R1AN3AS tD)LERR Ir k1UT 10 a sa
" t 's' E XA_VANAUElLl U_._ _ _ _ _ _ _ __
AR0001392 001 aooRE..
r__ _ _ 3RK_N3CLI P P._Q_B91_551.__ _ _ _ _
'""a*
_ _ _ _ l1TTLE._RQCE_AR 31213__ _ _ _ __A_
Mo~iToNi~c eENioo
'EAa a
oAv i i
'<Aa a
oav re.nau_ -- -- -
" _B 2 _05.._01] Tft L.s 2u05_31.
LsC2722N_
min m as; m as, R U c"
- 2" NOTE: Reed instructions before completing this form.
(J Card Only )
QU ANTITY OR LOADING (4 Card ORly)
QU ALITY OR CONCENTR Af TON PAR AM ETER (46-33)
(3441)
(3345)
( d$-JJ )
($441)
No.
'mu 8 "v"P t
"'I gr T
Ex A~A o...
,,,,,7, AVERAGE M AXIMUM UNITS MINIMUM AVERAGE M%RIMUM UNITS gg g
SAMPLE
"'^*""'"'"'
Once Through Cooling 785.5 1143 MGD 0
Cont.
Record h'ater (001)
,E R M I T Flow 1123 1145 Cont.
Record SAMPLE O
"'^*""'"*"'
79.7 92 F
0 Cont.
Recorc Temperature 105 110 Cont.
Record
,E R M,7 R EQUIR EM CNT S A M PL E Free Available 2 M9 5 7M Kg/ day N/A n _ nu n?
mg/l 0
M Grab.
NOT Chlorine PER M,7
" EoUiR EM E"7 71 181 SPECIFIED 0.2 0.5 1/7 Grab S AM PL E MEASUREMENT PE R MIT R EQU IR EM ENT S AM PLE MEASUREMENT PERM IT R EQ UIR EM EN T S AM PLE MEASUREMENT PERMIT R EQ UIR EM ENT S AM PLE MEASUREMENT PERMt?
REQUIREMENT N AM E / TITLE PRINCIPAL EXECUTIVE OFFICER I CFRTMY UNDER PE NAL TY OF LAW THAT I HAVE PF RSON ALLY E N AWNf D TELEPHONE DATE AND AM F AMtLtAR WITH THE. INFORM ATION SUBwTTt.D eFRf th AND BASED ON MY INOuiRY OF THOSE *Ntuv eOU ALS IMME Dra r E L Y WESPONS HL E FOR
/)
08' A*NG T*.E INFORMATION 9 BELIEVE THE SURMITTE D INFOeEM ATIO.c.
N n
Levine N'FCANY PE' N ALTiE S FOR SUE 1MTTING F AL 5F 6NFORM AYiON INCLUOtNG
. h!v.
<...c.
is TaoE Accu AYE A~n coM LETE. AM AaARs Thar THEPE ARE s
- .1 General Manager StoND uRE OP4RiNCiPAL EXECUTIVE 501 964-3100 1982 07 14
/
w Posw.mv Or r,~E Aso ~~aso~ MENT sEE is usC % 20o'
^~o
- 3) u sC % i199 1% no trwe onder threr stats tre mav owlede fuere up to $ loan A ^
c[nE TYPED OR PRINTED
- a' *A *'* ** ** **'* *'"' al h* "8 8 *aa' A * *d 5P'* ** #
OFFlCER OR AUTHORIZED AGENT NUMBER YEAR MO DA)
COM MEN T AND EXPL AN ATION OF ANY VIOL ATIONS ( Referrare all eff<ss hmems herr 3 E P A Form 33201 (Rev. 10 79) PREVIOUS EDITION TO BE USED (REPLACES EPA FORM v-40 WNBCN M AY NOT DE USEC.:
PAGE 1 OF5 UNTf L SUPPLY IS EXN AUSTED
r
.s hERMITTdE Ns'.ME/ADDTE23 Ilarlede N ATION Al., POLLUT ANT DB2CH A: IGE ELtMIN ATION CYOTEM t.VDf.5) form Affrmed lacanto %umo/Locanu>R st dderent)
DISCH ARGE MONITORING REPORT (DMR)
OMB h I.M - RCO h s__,__ ARK &NSAS POWER _&_L.IGHT_.CQ__ _ _ _
'2 1 *
'17 l'"
, dor o__W1. c1VARAt1Gli._112_ _ _ _ ___ _ _ _
an oo 0139 002 A
_ _ _ __ ARK _RUCLEAR-R_0_EDX_551.._ _ _ _ _
"""u""5" o'*c"'" ~**"
-__ _ __LITTLE_ROCE_AR_7221.3_____ _ _ __A_
MosaawlsseEmoo
. w. n u r _ _ ---
"o i o"
*a "o
I o"
._ loc;_T2n*_
82.051_01 TR _81_01!_21.
e:rs <:: i, ru m p g esin o n, m srs NOTE: Read instructions before completing thiS form.
($ Card Onl)) QU ANTITY OR LOADING (4 (.srd Only)
QUALITY OR CONC ENTR ATION FREouthcv PARAMETER (46 33)
(541)
(3445) 44643)
($447 )
NO.
gau gg gp Ex n <
.NAL,...
AVERAGE M AxlMUM UNITS MINIMUM AVLRAGE M AXIM UM UNITS y
g p.,g Cooling Tower Blow-
$^Me'E Esti-down Water (002) 3.569 5.76 MGD n
nn i h-
,t, t n Listi-Flow PERmT 20 35 Daily nate SAMPLE Free Available MtASuacME~T
.028
.091 kg/ day N/A 0.1 0.2 ng/l 0
1/7 Grab Chlorine NOT REQUIREMENT 15 38 SPECIFIED 0.2 0.5 1/7 Grab E A M PLE "E^"uREME"'
7.7 N/A 8.6 pli 0
23/31 Grab PERMIT
"'*"'at"""'
6.0 SPECIFIED 9.0 1/7 Grab S AM PLE MEASUREMENT PERMIT R EQUIR EM ENT S AMPLE MEASUREMENT PERMIT R EQUIR EM ENT S A M PLE MEASUREMENT PERMIT REQUIREMENT S A M PLE MEASUREMENT PERMIT REQUIREMENT N AME / TITLE PRINC6 PAL EXECUTIVE OFFICER I Cf RTIFv L ADE'R Pt. NAL T Y OF LAW THAT t HAVE Pf pSONAt L V E N AM NED TELEPHONE DATE AND AM F AMilsAR W TH THE sNFOFMATsON SUBMNP HE *E N AND BASED ON MY DNQUtRY OF
- HOSE ADVIDUALS IMMe > A ttt y RgsppNSggg yog
/,)
1 r%f A.N.NG T >+E sNF ONh A T SON I Bf t fEVE THE SUBMITTED INF C RM A TION f
sI. h {
Pa.
14CY1nC N TRu ACCUR A TE AND COMPL ET E e AM A A ARE THAT THERE ARE SG
{- f '/ s# L"*,
PeIF( ANT PLNALT +[ S FOR $UtgMsTTING FALSE AFORMATON i,NCLUE%G N
e General Manager SiaNWRE Or %6NCiPAL ExECurivE501 964-3100 1982 07 14 THE ow,T v o, rat AND.M-so~MsNT stE isuSC ou'
^~o 3 3 U S C % 1319 elvmahare a (8 prae oferwar. mev seris.fr /sers asp to Fff# t*=*
emd.a me umam ampes oame ri,nder A
A..
NUMBER YEAR MO DA' of haris,ce 6 mogra. end s >'*'* 8 OFf1CER OR AUTHORIZED AGENT TYPED OR PRINTED c
COMMENT AND ExFLAN ATION OF ANY VIOLATIONS t hrferrer< e -id offm hments Irrre )
EP d Form 33201 (Rev.10 79) PREVIOUS EDITION TO BE USED (REPLACES EPA FORM T-40 WHICH M AY NOT BE USED.)
PAGE Z OF5 UNTIL SUPPLY 15 ExH AUSTED
m - - - -
PERMITTEE N Ah4E/ ADD %E03 (inflade N ATION AL POLLUTANT Dil: CHARGE ELIMIN ATION SY3 TEM (N/Dfj)
[Orm AffrOn td hohen bame/Loceswn at dderent*
DISCH ARGE MONtTORING REPORT (DMR)
OMB.% IM - ROO s n _ _ ARK MSAS POMER_ft'LIGHI__CQ__ _ _ _
'2 io
<ir 19e A D~ Em_JdR. C AVM AUGtLlu__________
AR0001392 003
'__ _ __AB MUcLEAB=_P__Q_BDX_551__ _ _ _ _
"Ea"i' "u""Ea
= ~ aa' ~u M a'a
_ _ _ _ _ L I T T L E _ R n c E._ A R _7 1 2 1 L _ _ _ _ _ _ 4 ___
Mo~iToRiNo eEa.oo
'Eaa
-o o"
' E
- a !
~o ! oa'
~
. rmttr_ _ _
'a " _e 2 _ _05_0L TH _B2L_05 L_31.
'OCATiOu co m em m"
R U "" * * * * " 3n NOTE: Read instructions before completing this form.
($ CarJ Unit )
QU ANT 6TY OR LOADING 84 Card Only)
CU A4.4TY OR CONCENTR ATION
- a ' $','.*.C '
PAR A M ETER (443I)
(34 41)
(3343)
(46-33)
(3443)
NO.
sAMPL Em TvPE A~Ao AVERAGE M AXIM UM U N IT S MINIMUM AVERAGE M AXtMUM UNITS y
SAMPLE Total Oily Water Separator
.1155
.2204 MGD 0
Daily 1,ed lotal Discharge (003)
- PERM, R Ec uiR EM ENT 0.2 0.5 Daily ined Finw S A M PLE Total Suspended MEASUREMENT 3.89 6.51 Kg/ day N/A 7.85 17.5 mg/l 0
1/7 Grab Solids wt PERM IT R Eovia EM ENT 23 76 SPECIFIED 30 100 1/7 Grab S A M PL E Oil and Grease MEASUREMENT 6.58 12.58 Kg/ day N/A 10.36 17.4 mg/l 0
1/7 Grab PE RM IT R EouiREM Ea7 11 15 W*
SPFCTFTFD l t; 20 1/7 Grah SAMPLE "EASuREuENT pH 7.2 N/A 74 pH 0
1/7 Grnh PER M IT REoU REuENT (i _0 SPFCTFTFD 0n 1/7 Crnh SAMPLE MEASUREMENT PEPMIT R EQ UIR EM ENT S AM PL E MEASUREMENT PERM IT REQUIRE M RNT S A M PLE MEASUREMENT PERMIT REQuf REM ENT N AME/ TITLE PRINCIPAL EXECUTIVE OFFICER 6 Cf.RT T Y UNDER PENALTV OF LAW THAT I HAVE PERSONALLY E R AM'NED TELEPHCNE DATE AND AM F AM4 TAR WITH TMF INFORM AT'ON SUMM**-* L O ME REIN AND SASFD
-[
.J. M. LOVinC ON My rr3PRV of Ter tNDeVtDUAL5 IMME DIA TE LY RE SPONS*BL E FOR c,eT A.N.sG TMr r.roRMAvom i ettie s t T*r sueM.TTr0 r.rORM AT,0N
/h q#
{2Cncral 4fanagCr AC, CURATE TMf RE.~ARE
.M /
g f5 TRUE.
AND COMPLETE # AM AAARE THAT SIG f
N& wu o
~,r.C A~T r uAtTie s rOR susMiTTisc r AtsE isrORMAY.O~
Ct uDi~o URE Oh'PRINCIPAt. EXECUTIVE 501 964-3100 1982_07 _1L St NA 3 U%
6 1
=cl r 4 se. r te me nr(, f n a op it TYPED OR PRINTED
- /"'***"""*'*P""*"*#M""*d'*"*'A'**'a***
hFICER OR AUTHORIZED AGENT A"E^
NUM BER YEAR MO DA%
C DC COM MENT AND EX PL AN ATION OF ANY VIOL ATIONw E Nrfreen< a vil attua tements hrre)
E Pd Form 33201 (Rev.10-79) PREVfOUS EDITION TO BE USED (REPLACEG EPA FORM T-40 WHICH M AY NOT BE USED.9 PAGE 3 OF UNTIL SURPLY lS EXH AUSTED
FE2MITTEE N AM E /ADDRE39 (Intladr N ATION AL POLLUTANT Ot@CH ARGE ELIMIN ATION SYSTEM tNPDM) forat Approud 9 yds,ts bame/Loceswn ry dderens) gggcygpag ygyg3ORlyG pgpORy goggy QMg Na_ l}$. RC9 e n _ __ARKAU A8 PCMER.Ji_LIGBT..CQ-_ _ _ _
'2 'o
" m>
. ADD E.S__MM_ CLYAMAUGH lIL_ ___
l ARQAQ1392 004 ARK _IDELEARsP_Q_3DX_551__ _ _ _ _
l J *c " ' "" ' '" " " "
p _ _ __LITTLE_ RACE _AR_72213_____ _ __4__
M o~ a o R m o rE,u o o n AR MO l DAv vEARI Mo i cAv
. ruu,ur_ _ -
.nOC2T22=_
_ 02 0,5L01. TM _821_05 i 31.
corn m as, m as, p y on 7s
<:a w im 3n NOTE: Reed instructions before completing thle form.
( f ( erJ Ont) )
QU ANTITY OR LOADING (4 ( sed Only )
QU ALITY OR CONCENTR ATION F n Eo,u E W v PAR AMETER (46-34)
(54 6f p (33-45)
(46Jf)
'3443)
NO.
g pgg p
A~ Ao.s.
,y.,,,
AVERAGE M AXtM UM UNITS MINIMUM AVERAGE MAXIMUM UNITS g
Each Total SAMPLE Low Volume MEAbuREMENT 0.142517 0.2976 MGD 0
Release iced Waste Kater (004)
Each Total
,E R M,7 Flow R EouiR EM ENT 0.15 0.3 Release irei E A M PL E Total Suspended "EASuRE"E"'
93.8 456.5 Kg/ day N/A 178.4 868*
mg/l 1
1/7 Grab Solids NOT
,E R M,7 R E a u ' a '" *"'
17.1 N/A 3PFCIFTED 30 100 1/7 Grab S AM PLE Oil and Grease
" ' ^ " ' " ' " ' " '
2.1 8.8 Kg/ day N/A 3.9 16.8 mg/l 0
1/7 Grah_
NOT PERM 7
"""E"""'
8.5 N/A 3PECIFIED 15 20 1/7 Grah_
"5""'"'N' 6.1 N/A 9.0 pli 0
1/7 Grab p!!
PER MIT a'
u'a'"""7 6.0 SPECIFIED 9.0 1/7 Grab
'B A M PLE MEASUREMENT PERMIT R EQ UIR E M ENT S AM PLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MtASUREMENT PERMIT R EQUIR EM EN T N AME/ TITLE PRINCIPAL EXECUTIVE OFFICER
' CERT >Fv UNLfp PE NALTV OF LAW THAT a HAVE PTRSONALLY ER AMiNED TELEPHONE DATE AND AM F AMtLIAR WITH THE INFOstM AT*0N SUDMITTf D MERf rN AND RA",ED ON My WQtJfRY OF TME WDV *DU AL S iMMED A T E L Y PE SPONS3BL E FOR j, k [GgFfgg
// /g,,[ /*'.Q-
,p COT ArNAG TMC INF O*W ATION a BE Lit vE THr sueMeTTED INFORMATION 45 TRUE ACCURATE AND COM8"LETE I AM AWARE THAT THER; ARE SIG.
g
~*ca~T
= 5 'oa 5""" ~
'a'5*
General Manaper POSc eLeTv "OV
'aro"" =.,actu=~c gggggyf qg og pg"gjNCIP AL EXECUTIVE 501 964-3100 1982 07 1.:
o TwE F tNE ANO 'M5*MWMLNT SEE toUSC 1001 ANO 33USC 613'9 r fvoa fteen under theer eroterre me, ena larte fenre p to $1Qaos
- y AR A TYPED OR PRINTED 8"d *' me tamam f*Pesso#emest ef Arravve 6 must4s esid $ yrees s O(FICER OR AUTHORIZED AGENT NUMBER YEARi MO DA4 c, g COMMENT AND EXPL AN ATION OF ANY VIOL ATIONS I Nrferrna r all art.n hments herr)
.*Ref. CL-2112 GP A F'orm 33201 (Rev.10 79) PREVIOUS EDITION TO BE USED (8tEPLACES EPA FORM T-40 WHICH M AY NOT BE USED.
PAGE 4 OF 5 UNTIL SUPPLY IS EXH AUSTED
7 ARK ANSAS POWER & LIGHT COMPANY FIAST NATICNAL BUILDING /P O. BOX 551/UTTLE ROCK. AAKANSAS 722o3/(5011371-4422 June 23,1982 WILLfAM CAVANAUGH, lll Senior Vice Prescent Energy Succ:y CL-2112 Mr. Dick Whittington Regional Administrator United States Environmental Protection Agency Region VI First International Building 1201 Elm Street Dallas, Texas 75270
REFERENCE:
Arkansas Nuclear One NPDES Permit Number AR000i392
Dear Hr. Whittington:
This letter represents a noncompliance report as required by Part II, Para-graph A.2 of the above referenced Pemit.
On June 4,1982 the limit for total suspended solids (pemit limits 30 mg/l daily average,100 mg/l daily maximum and 17.1 kg/ day) for outfall 004, low volume waste, was exceeded due to a discharge concentration on this date of i
868 mg/l or 457.5 kg/ day. All other parameters were within limits.
Analysis from this outfall is accomplished with a composite sar.ple which is gathered over a one week period; therefore, results are not available until after the weekly composite sample is completed. This violation was reported to the General Office on June 16, 1982.
An investigation has revealed that this violation was caused by events fol-lowing a primary to secondary leak in the ANO-1 steam generator. The unit was shut down to repair the leak and the contents of the steam generators were drained to the turbine building sump. Because the contents of the steam generators were potentially radioactive, the water had to be collected and sampled to ascertain its radioactivity or lack thereof. To accomplish this collection, the turbine building sump discharge had to be diverted from its nomal treatment system (the oily-water separator and dissolved air flotation polisher) to the 65,000 gallon neutralization tank. Once the water was in the tank, no means existed for conveying the water back to the oily water separator treatment system.
It was therefore discharged from the neutralization tank without its normal processing.
It should be noted that these primary to secondary leaks are infrequent in occurrence.
2 i
CL-2112 Mr. Dick '.!hittington June 23, 1982 We are presently evaluating alternative procedures for the accounting of radioactive liquid releases during these unusual occurrences. We are also evaluating the option of further treatment of discharges from the neutrali-zation tank. We will chcose the best alternative to ensure that a viola-tion of this type does not occur in the future.
Yours very truly, f
f La=
^*
.1
, / y Z.
..Mn WilliamCadnaugh I;I
/
~...'
WC/DLS/ew cc: "es s rs.
J. L. Maulden C. L. Steel
'l.
G. Coleman D. L. Swindle /
J. D. Jackson J. M. Gri f fin J. Levine J. Southall, Di rector Arkansas Department of Pollution Control and Ecology l
~
+.
9sERMITTEE N AM E/ ADDIE03 (loclude N ATION AL POLLUTANT DIECH ARGE ELIMINATION SYCTEM 4 AfDES)
[OPPPI Afff0lfd r ecqir, Aemc/Laerwm sf dd< rent)
OlSCH ARGE MONITORING REPORT (DM2)
OMB No. W - R00 dii_ _ A RKAMB AA_IDER _LkI GELC Q_ _ _ _ _
<2 'o
'm*
scones;___WM__CAYANAUGILIIL _________ _
An0001392 005
___ _ _._ _.ABK_RUCLI AB =_P__Q RQX _5 51___ _ _ __ _
' " " ' * " ~ " " " ' "
'.___ _ _.__LUlkE_ AQC3_.AR _71213_.__ __ _ _ __4_
uoNiToniNo eEnico i
" i a'
rnurtir_ _ _ _._ _ _ ___ _ _ _ _ _ _ _ __ _ _ __ _ _ _
toc AT:Ou__ ___
"__$ 2 _0}j_01 M _12-_0 5 l 31___
ca ssi tra rij
<r4 m R tj ca st, ca.%
..w sn NOTE: Flead instructions before completing this form.
( f Card Om/r )
QU ANTITY OR LOADING (4 Card Only)
QU ALITY Ost CONCENTR ATION PARAMETER
(#6-j f )
($4 41)
(1845)
(46-53)
($441)
NO.
FatouthCs g g u pgg gp EX TYPE AN Au sts AVERAGE M AltlM UM UNITS MINIMUM AVERAGE M AXIMUM UNITS g
g Esti-SAMPLE Sanitary Sewage MEASUREMENT
.010613
.021 MGD 0
Daily mnte Discharge (005)
Esti-PER MiT Flow REauiREMENT 0.025 0.1005 Daily mnte SAMPLE N/A 4.96 7.0 mg/l 0
1/7 Grah Total Suspended
"'^SUREME"'
Solids NOT
"'*"'"'"*"7 SPECIFIED 30 45 1/7 Grnh S AM PLE N/A 12.55 19.5 mg/l 0
1/7 Crnb_
Biochemical Oxygen MEASUREMENT Demand NOT P E,,,7
"'*"'"C"*"'
SPECIFIED 30 45 1/7 Grnh S AMPLE pil MEASuREMEN' 6.2 N/A 6.7 pil 0
1/7 Grao NOT PER MiT 6.0 SPECIFIED 9.0 1/7 Grah S A M PLE MEASUREMENT PERMIT REQUIREMENT g
S AM PLE MEASUREMENT PERMIT R EQ UIR EM E NT S A M PLE MEASUREMENT PERMIT R EQU IR EM E NT N AM E/T8TLE PRINCIPAL EXECUTIVE OFFICER t CE R TsF Y UNDE R PE NAL TY OF LAW THAT i HAVE P ER*.ONALL Y Ell AMsNE D TELEPHONE DATE AND AM F AMILLAR W8TH THE eMORMATON SURMITTED Mt pf ete AND BASED
'ON MY INOiHRY OF THOSE tNDviDuaLS eMMED AT E L Y RESPONSsRLE FOR OBT AIN+sG THE INF ONM A f SON BEL sEVE THE SVRMrTTED INF ORM ATO.G. & f((y-- E N
.l. M. LeVine
's tauE ACCupATE AND Comet RTE i AM A ape TWAT TwERE A r,E S NtFIC ANT PE N ALTtF S 90R SURMITTING FALSE *NFORMATION INCL OONG S,GN,4TURE OVPRiNCiPAL EXECUTIVE 501 964-3100 198' 07 14 General Manager iaE e<=n v cR raf ANo -ea*~ME~r StE isuSC i imi a~o
~
+
33 UV 913 99 al>nahare esewire theer etaterre near norlude knen up to $10lkus A
TYPED OR PRINTED 8'"I"**"*'"***P"'""*'"40"#'*****'***d3>#8"'
QFFICER OR AUTHORIZED AGENT NUMBER YEAR MO DA) g COM MENT AND EXPL AN ATION OF ANY VIOL ATIONS i Nrferrai r all utf44 tterait here)
- EP A Form 33201 (Rev.10 79) PREVIOUS EDITION TO BE USED (REPL ACES EPA FORM T-40 WHICH M AY NOT DE USEDa PAGE g OFf UNTIL SUPPLY 15 EXH AUSTED
y_
PERMITTEE NAM E/ADDAES$ (laclude N ATION AL POLLUTANT DIECH ARC E ELIMIN ATION SYSTEM INPDf 3) forrri Aff'rcstd fec4 pome /Lacesnow ut dWeren')
WSCli ARGE MONITORING REPORT (DMR)
OMB No.133 - RC3 7
N4ns_.>_bEKLUAA 2.0%EB_s k1GBLC0____-
a i*
m' ADoaus_Jf!LJA' VANAUMLlH_ _ __.____ _ _ _
AR00Q1392 OA1
__ _ _ _A RK_HD C L E AE =_P_CL. RD X _551__ _ _ _ _ _
"'""""""E" a'""*""~"-""
1 ______LIIILE_RDCE_AA_72213__ _ _ _ __6__
MoNiToni~o eEa,co o"
r a urtu _ _
Traa Mo o"
. '<aa Mo
' LOC A Tion _ _ _. ___
g{ Q6 Qg
]g _g g_ 6 l
)_Q_
FROM Q
oorn m as, tse rs' R U *n
'2" 2*
'" 3n NOTE: Read instructions before completing this form.
( f ( ord Onts ) QU ANTITY OR LO ADING (d Card Only)
QU ALITY OR CONCENTR ATION
'" EOg[ *'C '
PAR AMETER (44-33)
(54 61)
(38 45) t d6-JJ )
(5441)
NO.
SAM I
AN a m o,.,,,
AVERAGE M AXIM UM UNITS MINIMUM AVERAGE MAXIMUM UNITS Oh WO W N)
SAMPLE Once 'nirough Cooling 1023 1129 0
Ccnt.
Recor "E^"""E"*"'
Water (001)
MGD PE R MiT Flcw "E
" '" E" E"Y 1123 1145 Q,nt.
Recor S A M PLE "E^"uREuENT 86.4 94.8 0
Cont.
Recor PERMIT
'f
'Ibnperature R EouiR EM ENT 105 110 Cont.
2.137 5.25 N/A 0.078 0.18 0
2/7 Grab Free Available Kg/ day Nor.
mg/l
,E MiT Glorine REou REME"'
71
. 181 SPEunw -
0.2 0.5 1/7 Grab _
SAMPLE MEASUREMENT PERMIT RECURREMENT S AMPLE MEASUREMENT PERMlT R EQ UIR EM ENT S AMPLE MEASUREMENT PERM 87 R EQ UIREM ENT SAMPLE MEASUREMENT PERMIT R EQUIR FM EN T N AME/ TITLE PRINCIPAL EXECUTIVE OFFICER I C E CT'F Y L NDrR M NsLTY Or L AW YnnT e NA,E Pres.ON ALLv Ex AM'NED TELEPHONE DATE AND AM F AMtLiAR WITH T* d INFONMATION SUBMITTED e(qEIN AND B ASED ry a
J. M. Levine ON, A,Nm T E
,O,,e,0,THO.*1,0NIND,eviDUALS,E8M,ME D** T L.vTTEo
,N,./S.LE MY INGUppy E
- ESPONf FOR A
r co omt
.E So.
0 AT,0N Cicneral gh, nager as,,T R,UC A,CC,,UR A ' EA,ND,, C OMPL ET E,No A,M
,Nro T THE RE, Net uo No
{
rw-t AWARE THA ARE SsG.
e N c NT
.< ALT Es 0
SonM,TT ALSE A T,0N A
v 501 964-31001982 0
la T HE POS%#DsUTY Or FINE AND IMPRISONMENT SEE 18 USC 6 1001 AND SIGNpiURE OF
- PRINCIPAL EXECUTIVE 33USC %1319 f f'enaltu a under theer eretuten mas snelude lanen op to SinsMnb A
A and ar r no s4mu n empemenaienr ef lu ruwn d monias ensf 5.wors s DFFICER OR AUTHORIZED AGENT NUMBER YEAR MO DA)
TYPED OR PRlNTED a
c g
COMM ENT AND EXPLAN ATION OF ANY VlOL AT8GNS t Rr/rtrm e eed offm hments hfrt)
- EP A (orm 33201 (Rev. 10 79) PREVIOUS EDITION TO BE USED (REPLACES EPA FORM T-40 WHICH M AY NOT RE USED.
PAGE OF UNTIL SUPPLY lS EMH AUSTED u
l __
__5 _ _ __
PERMlTTEE NAM E /ADDREES tindrede N ATION AL POLLUTANT Dl2CH ARCE ELIMINATION CY3 TEM (NPDF.3) l'orm AffrtM rd Ikith b enei matwo of dsCerent),
DISCH ARGE MONITORING RCPORT (DsHE)
OMB No. !!S - R0th l
Naip__ _'_ARKAESAS POL'tH 5_h1GNI._C0__ __ _
e na o n9, fDrEss__WM CAVAMARGl_IU _ _ _ _ _ _ _ ___.._
AR0001192 002 PERMIT NUMBER DISCMamGE Nuussa
_ _ __ ARK N UCLfdB =P_0_3D X _5 51 _____
.__ _ __LIITLE_ RACE _AR_71113__ _________3_
MON.TOo,No oEn,oD VEAa MO oAv i vEAR MO ; cAv ranur _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
_62.. 0 9_01. TM L_8 2_o st3_0j j
.qC. Anna __ --
i oirn es a cem gg asm c e 29, sw m NOTE: Read instructions before complehng this form.
' g 3 f ord Only) QUANTITY OR LOADING (4 ( ard Only )
QUALITY OR CONCENTR ATION
'"EQ$E*C' PAR AM ETER (46-53) d3441)
( Jd.43 )
(46-33)
($448 )
NO.
S A M plt g
AN A6vses
}
g j7; AVERAGE l
M AXIM UM UNITS MINIMUM AVERAGE M AXIMUM UNITS g
.g bt-SAMPLE Cooling Tower Blow-5.257 5.76 0
Daily Imte EASuREMENT down Water (002)
MGD Esti-PERuiT "E
" ' " E" 5"7 FIN 20 35 Daily mate SA M PL E
"'^*""*"'N'
.026
.045 N/A
.058 0.1 0
1M Grab kg/ day NOI' mg/l Free Available PERMIT Chlorine 15 38 datmru 0.2 0.5 1/7 Grab __
19/30 M
""^""E"'N' 7.8 N/A 8.6 0
N PERMIT pH 6.0 SPECIFIED 9.0 1/7 Grab _
S AM'
)
S AM PLE MEASUREMENT PERMIT R EQUIREM ENT l
S AM PLE MEASUREMENT PERMIT REQUIREMENT j
l N AME/ TITLE PRINCIPAL EXECUTIVE OFFICER 1 (E RT+ v UNt fR PENALTV OF LAW THAT I MAVT PE RSONAL LY E A AMfNE D TELEPHONE DATE 1
AND AM FAMC.AH W4 TH THE *NFORM ATION SUBMiTT ED MEREIN AND BASED I
(#4 Mf INQU+R f OF THOC,E INDIV4DU AL S IMME Di A TE L Y RESPONS DLE FOR OHT A>NaNG THf IN* Of*M ATION t BE L IE VE THE 5.UMM 7TfD INF ORM A TION 3
j, f.h [G(Ff yQ IS TRUE ACCL,R AT E AND COMPL ETE I AM A A ARE THAT THE RE ARE sag N4 pC ANT PE N A LTsFS FOR ( ul4MtTT*NG FALSE tNF%M ATION INCLUDING era 1 ba@p SI,GN,ITUR E OP 'PRINCIP AL EXECUTIVE501 964-3100 13.8 2 07 14 M
iam F E ANO IMPRISONMENT SEL 10 USC 6 lODI AND 33UsC 91319 ti'enaltare ennter the.e staturre ma s emiude p to $losuni a'=t v* m8 84*8
- r'P'8*am'n t ul Artu een E munthe and.5 pers, fnnen
' OFFICER OR AUTHORIZED AGENT NUMBER YEAR MO DAD TYPED OR PRINTED COMMEN T AND EM PLAN ATION OF ANY VIOL ATIONS INcfstr8ac erJ utt.nhergts here) 3P4 rorm 33201 (Rev. 10 79) PREVIOUS EDIT 80N TO BE USED (REPLACES EPA FORM T-40 WHICH M AY NOT SE USED.
PAGE 2 OF $'
UNTIL SUPPLY IS EXH AUSTED
P%MITTEE NAM E/AJD%E33 (in(It de N ATION AL POLLUTANT Dl!CHl.RCE elf MIN ATION SYOTEM (NPl>t.S p forrrt A Trotrd
/
E wa,t> Aagtmanwa./ aggrews)
OtSCH ARCE' MONITORING REPORT eDMR)
OMB A>. UA. ROO ea__JRKANJAsjtog13_Ll@Lc0_____
003
<2 io cim W M C A VMAUJLJ U_ __ _ __ _ _ _ _
A_R0001392 A eDr E..
4___JU.ECMA_B'=1_OlolJ s 1 M o ~1To m ~ a rE nto O PERMIT NuM=Ea E".c-cE Nu-ER
____ k1 TIKE _RQCLARJ121L_____J_
~o o_
~* ' "*'
w,nto__
LOCATIOu
'"o*
82 06 01 TN ~82 06 1 30 aoso m si 7 42
RU
- 2^
- 3*
NOTE: Read instructions before completing th!n form.
(J Card Only) QUANTITY OR LOADING (4 Card Only)
QU ALITY OR CONCENTR ATION F e E Qu,E hc v g g u ptg PAR A M ETER (46-33)
(3441)
(33-45 )
(4033)
($44f )
NO.
g our)
AVERAGE M AXIM UM UNITS MINIMUM AVERAGE M AxlM UM UNITS
, g
/
'10tal
' Oily Water Separatoru E ASuiEM ENT 0.1834 0.2523 0
Daily ized Discharge (003)
MGD
'10tal F1w REo"u'!%IlENT 0.2 0.5 Daily ized M E A s'u"#Et'LT 8.97 11.53 N/A 13.2 20.5 0
1/7 Grab Total: Suspended Kg/ day Mr ng/l Solids
,Eo"USEENi 23 76 setu.tnw 30 100 1/7 Grab M Ellu"R EM ENT 6.85 8.44 e N/A 9.2 9.95 0
1/7 Grab Kg/ day sr ng'l Oil and Grease rec"i REM Eu?
11 15-dnunw 15 20 1/7 Grab
^ "
M E/Su"R EM ENT 7.2 N/A 7.9 0
1/7. Grab rur pH pH R e.o"uMEN-6.0 SPECIFIED 9.0 1/7 Grab S AM PL E e
MEASUREMENT PERMIT REQUSREMENT S AM PL E MEASUREMENT PERMIT R EQuiREM ENT S A M PL E M E ASU REM ENT PERMIT
/
REQUIREMENT N AME/ TITLE PRINCIPAL rJtECUTIVE OFFICER I Cf RTirW UNDER PE NALTY OF LAW THAT I HAVE PE RSONAL L Y ER AMINED TELEPHONE DATE FAM ltAR WITH THE INFORMATON SUBMITTFD HEprlN AND BASED ant.,AM i
ON My eaQU RY OF THO5E tNDIVIDUALS eMME DI A T E L Y RE Sf*ONS BLE FOR Opf A N NG THE iN'ORMATON I BE L'E W E THE SU BMITT E D INFORMATION
<W//
.T. M. Levine is TauE accoRarE a~D coMeLETE i AM Aa
- RE THAr TacRE A RE Seo-m b
NhC As t PEN #s T ES FOR SURMITTING FALSE INe ar4M ATON INCLUDING
'-c * *" or
"~E
- "*aso = T EtE ' u s c * 'oo'
^~o JTURE OF PRINCIPAL EXECUTIVE 501 964-3100 'L982 07 14 General Manager e
33ubC\\1319 t rM. alters wwer three stanten mov snelude fare 6p in $10.tstm
/
ARE e, d or ma ssm.m **.*pn=aamenst o/ hrtuws n montha and 5 waru OFFICER OR AUTHORIZED AGENT NUMBER YEAR MO CAY TYPED OR PRINTED i
e 5DE AND EXPL AN Ais 3N OF ANY VIOL ATIONS E Rr/ crena r wh strut /tmearts here p
. COMMENT
, E P A ' Form 33201 (Rev. 10 79) PREVIOUS EDITION TO BE USED 1 REPLACES EPA FCsRM v.40 WHICH M AY NOT BE USED.)
PAGE 3 OF 5 UNTIL SUPPLY IS EXH AUSTED
8 E lim 4 fT E E N A M E / A D DR EES ( las l*s./r N AT40N AL POLLUTANT DISCH ARGE ELIMIN ATION SYSTEM t VDEJ)
[OFF't APPPOlfd 8
f9de, hume/Lmotwo of dderent)
DISCH ARGE MONITORING REPORT (DuR)
OUR No. 08. RO
sp_2 ARKAtIAAA_E0Hf4_&_LIGli2__CQ ___.__
'im gD_. E2.__. f M_.COlANA4GIL_IU_._ __ _ __._ _ _ _ __
An0001392 004
.,_.__ _ _ _ _.A BKJiUCE&B =P_Q_ BQ X _51L _ _ _ __ _
"5"""u""'"
- "~'"'~"~a
[___,
kh MONITORING PERIOD
* " I "
^'
faq.StIy _ _.
LOC ATION_
_ 6 2. _06 0L TM _ST5 LOS.L 10 ]
FROM
<so rn cis m tre m RU man mw man NOTE: Read instructions tietore completing this form.
(3 CerJ Only) QU ANTITY OR LOADING (4 Card Only)
QU ALITY OR CONCENTR ATION PAR AM ETER (46-31)
(5461)
(184J)
(45-31)
($441)
NO.
FREouaNcv g g u ptg g
Ex TvPE A N Am...
AVERAGE M AXIM UM UNITS MINIMUM AVERAGE M ARIM UM UNITS ggy
,gg Each fotal-S AM Po t Low Voltune "Easu"E"E"'
.109252
.252667 MGD 0
Releas e itc Waste Water (004)
Each Total-
,E MIT Flow
" EQ u '" '" S"'
O.15 0.3 Release ized SAMPLE Total Suspended "E^="E"E"'
10.9 26.0 Kg/ day N/A 26.4 61.0 mg/l 0
1/7 Grab Solids NOT
,ER M IT R EQUiR EM ENT 17.1 N/A SPECIFIED _,,, _ 3 0 100 1/7 Grab S AM PL E Gil and Grease "Easu"'"*"'
O.4 0.7 Kg/ day N/A 1.0 1.9 mg/l 0
1/7 Grab NOT PERMIT 8.5 N/A SPECIFIED 15 20 1/7 Grab S A M PL E pil 6.2 N/A 9.0 pH 0
1/7 Grat NOT PER M IT 6.0 SPECIFIED' 9.0 1/7 Grat S A M PLE MEASUREMENT PERMIT R EQ UIR E M ENT S AM PLE MEASUREMENT PERMIT R EQ UIREM E NT S AM PLE MEASUREMENT PERMIT REQUIREMENT N AMF / TITLE PRINCIPAL EXECUTIVE OFFICER I CE RYi, Y UNMR FT N A L T Y OF LAW THAT t MAWE PfRSONA TELEPHONE DATE THE tNFO,vou Ats.SUBusTTED Nf RE,LLv E M AMINEDO~s D BA, SED AND AM FAMI WITH PW AT80N
--J.r M. Levine
.~Ou.L EAR Re sN AN ON -v Rv Or T OsE
~D
--mAfrt y LE OR t*erOftMA TION t BELEVE THE SL Bus TT E D WFORw a iia.JN ORT AthiNG THE ao c a r'r
A*
I
,.AI.
General Manager
- Taus Accuaa f t A*
- ai T-AT T-<ar at S'G
<t Pt N ALT tFS.FO. RAND..'T%G INFO, o u s C N+FIC ANT SUBM FALSE RM AT CN INCLUDtNG sinduRE Or%NCiPAL EXECUTIVE 501 964-3100 1982 07 14 T-r om.mB,oTv Or scoorNT set iioD' ao 33n.sSC \\f319 rl'enelewe uMer threr etaturre nues mrluie finre op to $:ispwn
/
^ ^
TYPED OR PRINTED
- '" "* ***** 'mP***'8a m** f "/ hrfu.ve d arenth e sM 3 we'*
- 0598CER OR AUTHORIZED AGENT NUMBER YEAR MO DA4 C
E COMMENT AND EXPLANATION OF ANY VIOLATIONS 4 Refrrres e sali estui hetrats here )
l l
l l
2P A Form 33201 (Rev.10 79) PREVIOUS EDITION TO DE USED (REPL ACES EPA FORM T.40 WHICH M AY NOT BE USED.:
PAGE OF UNTIL SUPPLY 13 EX H AUST ED 4
g
bO N 'Ad 138-R00',
fIIIDI P
MITTE' N ATION AL POLLUTANT DISCHK.RGE elf MIN ATION SYSTEM ( AfDE3) iYa,5.w,E NAM E/ADDRE20 (include OM8 c/t.ce:wa of accrent)
DISCH ARGE MONITORING REPORT (OMR)
N_ m _ _ _A RIUL U U J D U A _& _ A I E L _C Q _ _ _ _ _
e'*
m e_JM_14Bh4GH_lU____
Anooo1392 005 AB NUCLMP_P__Q_ LOX _51L__
. _ _ _ _ _,_ _ _ _i n T L E_.MCE __AR _7121L _ _ _ _ _ _3_
eawamso eEN,co "a
a o"
"'a ! ~ ! o" _
wuatr_____________________
LOCAT m __
___.____________i_
" _ B 2 _063 TM J 2Lo6L_3.01 an si, ese m n' RU ** ' ' ' *
'm m NOTE: Read instructions before completing this form.
~
~13 ( sid Only) QUANTfTY OR LOADING (d ('ard Only )
QU ALITY OR CONCEN1R ATION F R Eo,u,E mec v S AM PLE P A R A M ET E R (46 33)
(3441)
(18 43)
(46-33)
(344I)
NO.
EX TYPE ANAusit AVERAGE M AXIM UM UNITS MINIMUM AVERAGE M AXIMUM UNITS g
g, g
""^*""'"E"'
Sanitary Sewage
.0125
.0210 MGD n
n, ; h.
mate Discharge (005)
PE R M,7 Esti-Flow
" EQU iR EM E"' O.025 0.1005 Daily nate SAMPLE Total Suspended N/A 12.0a 31.0 ng/l 0
1/7 Grnh
"'^'""'"'"'
Solids NCrr.
,ERM T SPECIFIED 30 45 1/7 Grah S AM PLE "E^*""*"'"'
Biochemical Oxygen N/A 11.67 13.0 mg/l 0
1/7 Grah Demand NM
,e RM iT SPECIFIED 30 45 1/7 Grnh S AM PLE pli 6.1 N/A 6.5 pH 0
1/7 Grah PERMIT 6.0 9PECIFIED 9.0 1/7 Grah 8 AM PLE MEASUREMENT PERMIT R EQUIR EM ENT S A M PL E MEASUREMENT PERMIT R EQUIREM ENT S AM PLE MEASUREMENT PERMIT REQUIREMENT N AME/ TITLE PRINCIPAL EXECUTavE OFFICER I CERTWY UNDER PE NALTV OF law THAT I MAVE PERSONALLY E xAMmED TELEPHONE DATE AND AM F AMILIAR WITH THE MORMAT*0N SLBusTTED MEREm AND BASED
- d. h, hMRO ON Mf INQUIRv OF THOSE 'NDvsDU ALS eMMED ATE L Y RESPONstBLE FOR
's TauE = ~ ATE ANo coM*ETE ' AM AaAaE T-Ar T-EaE AaC s+
./
Oeva % c r-E ucwMarioN e swEvE TsE sueM,TTeD wORMATeoN General Manager NS < ANT PEN ALT 4 S FOR SveM'TThNG FALSE #wF ORM A YiON INCL UDNG TME h
& F iNE AND iMPR60NMENT SEE seUSC 9 1001 AND gggggjuME OF PR NCIPAL EXECUTIVE 501 964-3100 1982 07 14 33u5C %t319 e Arnetrars widra the se ersto es me v soie fede fasce op to $10 twas I
r TYPED OR PRINTED
- *J ar ** *"""* "#'* *"*' "t hr'"* 8 *onr4 s sad $ ye ri s OFF 4CER OR AUTHORIZED AGENT A R E A, NUMBER YEAR MO DA) g g COMMENT AND EXPLANATION OF ANY vlOLATIONS ( N#frecrM r ud strwhments hert)
L IP'A Form 3320-1 (Rev. 10 79) PREVIOUS EDITION TO DE USED (REPLACES EPA FORM v.40 WHICH M AY NOT BE USED.)
PAGE 5 "5
UNTIL SUPPLY IS ExH AUSTED