ML20062B525

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 780816-18
ML20062B525
Person / Time
Site: Purdue University
Issue date: 09/21/1978
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20062B521 List:
References
50-182-78-02, 50-182-78-2, NUDOCS 7810310033
Download: ML20062B525 (1)


Text

.

Appendix A NOTICE OF VIOLATION Based on the results of NRC inspection on August 16-18, 1978, it appears that certain of your activities were not conducted in full compliance with conditions of your NRC Facility License No.

R-87 as indicated below. The item is categorized as a deficiency.

Paragraph 4 of the Facility License states, that the license is deemed to contain Section 50.54 of Part 50 of 10 CFR which requires anyone that operates the reactor to have a valid operating license at that facility.

Contrary to the above, the reactor control rods were individually moved July 28, 1978 to perform a surveillance test by an operator whose license had expired on July 22, 1978.

l l

l l

l l

1.03.1. oo33

-