ML20059N640
| ML20059N640 | |
| Person / Time | |
|---|---|
| Site: | Grand Gulf (NPF-29-A-071, NPF-29-A-71) |
| Issue date: | 10/09/1990 |
| From: | Quay T Office of Nuclear Reactor Regulation |
| To: | |
| Shared Package | |
| ML20059N644 | List: |
| References | |
| NUDOCS 9010170074 | |
| Download: ML20059N640 (5) | |
Text
.
1 sl_
g A ff tilgf
<*: M UNITED STATES
,' 1
!(? '
j
- 3.
. NUCLEAR REGULATORY COMMISSION -
3f 5
J[
f WASHINGTON D. C,20666 b
e....
j ENTERGY OPERATIONSbINC.
SYSTEM ENERGY' RESOURCES. INC..
SOUTH MISSISSIPPI' ELECTRIC POWER ASSOCIATION l
. MISSISSIPPI POWER AND LIGHT COMPANY:
DOCKET N0;'50-416 a
GRAND-GULF NUCLEAR ~ STATION.-UNIT 1~
AMENDMENT TO' FACILITY OPERATING ~ LICENSE 4
y L.,
t Amendment' No.I71
. License No.lNPF-29 1.-
The Nuclear Regulatory Commission (the Commission) has found thato A;
The application for_ amendment by theilicensee' dated August 10, 1990, as revised August'20,.1990, complies with the standards and:
l requirementsofthe:AtomicEnergy:Act'of1954,.as' amended (th'e'Act),'
and the Conunission'sirules and regulations set forth in 10 CFR LChapter :I; B.
The facility will operate in conformity-with the application,xthe; provisions of the Act and the rules and regulations of the' Coinnission; C.-
There is reasonable: assurance'(i);that the activ'ities; authorized tiyf this' amendment-can be,conductediwithout endangering the health;and.
safety:of the publichand (11) thatasuch activities will'be conducted L
'in compliance with the Consiission's regulations;t
,(
ll D.
The issuance of this' amendment will not be11nimical to the comunon /
defense and security. or to the health?and; safety of the public; and
}
E.
The' issuance ofcthis amendment is in accordance with:10.CFR PartL513 l
ofc the Cossnission's regulations and all applicable requirements 1have; been satisfied.
s
-i l
9010170074 901009 I
PDR ADOCK 05000416i, p
PNV ('
s N
o
.2
=
f l[
.; m
+
j e'-
q k _.
l 12.
- Accordingly,J the license is amended by ' changes to the Technical; -
p-Specifications,ias indicated in the-attachment to this. license' amendment;-
_ andparagraph2.C.(2)ofFacilityOperatingLicenseNo.NPF-29)ishereby:
amended to read as follows:
~
. (2).' Tech'nical' Specifications 7
The Technical Specifications containedz in Appendix A:and the.
L
. Environmental, Protection Plan contained in Appendix B,:as revised through.1 Amendment No. 71'.- are hereby incorporated into this license. - Entergy Operations, Inc shall, operate.the. facility in
- accordance with the Technical Specifications and the Environmental:
Protection Plan -
+
3.
This license-amendment-is effective as of:its date of issuance..
FOR THE: NUCLEAR REGULATORY COMMISSION-g-
udCh
M:nimum level: > Minimum level Above' top of Level indication mark, indication mark, , plates,- and < %",above and.< %" above
- and: noti t
maximum ~1evel. maximum ievel overflowing 1 L indication mark . indication mark-i Float Voltage - > - 2.13 volts >-2.13 volts (b) ) 2.07: volts - ~ 1 Not~more than .020 below the average of;all; > 1.190 connected cells; 1.195(C) Average.of all-L Average, of-~ all I. Specific Gravity (a) connected cells. connected cells u 11.190(C) I >11.200 q (a). Corrected for electrolyte temperature land level'. (b) May be' corrected for average electrolyte temperature. (c) 'Or battery charging current, following.a~ battery-serviceJor performance t 4 -discharge. test, is.less than 2 amps _when on float charge._, (1) For any Category A parameter (s)foutside the limit (s).'shown, the-: battery may be considered OPERA 8LE provided that within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> all'the Category B measurements.are taken and found to.be:within-their allowable; values, and provided alll Category A and B parameter (s) are restored _to within limits: i within the next 6 days.. (2) For any Category 8 parameter (s) outside the limit (s) shown, the battery ' 'may be= considered OPERABLE provided that the Category B parameters-areL within their allowable values and provided.the ' Category:B_ parameter (s). are restared to within limits within 7 days. (3) Any Category B parameter not within its' allowable valuelindicates an inoperable battery. f GRAND GULF-UNIT 1 3/4 8-13L AmendmentLNo. 3 et ,mn, e .-..r.e-2 .w i L V ELECTRICAL POWER SYSTEMS i k.- 1* j; BASES i x .t ~ l A.C.-SOURCES, D.C. SOURCES and ONSITE POWER DISTRIBUTION SYSTEMS (Continued)' q -The surveillance requirements for demonstrating the OPERABILITY of the-unit batteries are in accordance with the recommendations of Regulatory Guide 1.129 " Maintenance Testing and Replacement of Large Lead Storcge Batteries for Nuclear Power Plants," February 1978, and IEEE Std 450-1980, 't "IEEE Recommended Practice for. Maintenance Testing, and Replacement of Large Lead Storage Batteries' for Generating Stations-and Substations.". Verifying average electrolyte temperature above the minimum for which the-i battery was sized,Ltotal battery terminal voltage onfloat charge, connection' ~ i resistance values and the performance of battery service <and discharge tests ensures the effectiveness.of-the charging system, the ability to handle high discharge rates and compares the battery capacity.at.that time-with the rated, capacity. Table 4.8.2.1-1 specifies the normal limits for each designated pilot cell and each connected cell for electrolyte' level,. float voltage =and specific-gravity. The limits for;the designated pilot cells ~ float voltage and specific gravity, greater than 2.13 volts and 0.015 below the manufacturer's ful1~ charge - specific gravity or a battery charger current that had stabilized at a low value, is characteristic of-a charged cell with adequate capacity..The normal limits for each connected cell-for ficat voltage and specific gravity;- greater:than - 2.13 volts.and not more than 0.020 below the manufacturer's full charge specific _ gravity with an average specific gravity'of all.the connected cells'not more. than 0.010 below the manufacturer's ful.1-charge specific gravity,: ensures the i OPERABILITY and capability of the battery... Exceptions to the specific: gravity-t y requirements lare taken to allow for the normal-deviations: experienced after. t a battery discharge and subsequent recharge associated with ~a; service.or, per-formance discharge test. The specific gravity deviations are recognized by-l and discussed in IEEE 450-1980.- . Operation with a battery cell's parameter)outside the normal limit but' within the-allowable:value specified-in Table 4.8.2.1-1Lis permitted for up.- L to 7 days. During this 7 day period:--.(1) theLallowable values"for electrolyte j level ensures no physical damage to-the-plates with'an adequate' electron transfer h capability;:(2) the allowable value for the average specific gravity of all. the cells, not more than 0.020 below the' manufacturer's recommended full. charge 3' specific gravity, ensures that.the decrease in rating will be less than the 4 safety margin provided in sizing; (3):the allowable value for an individual J L cell's specific gravity ensures that.an individual cell's specific gravity will L .not-be more than 0.040-below the manufacturer's full charge. specific gravity-J and that the overall capability of the battery will'be maintained within ani r acceptable limit; and-(4) the allowable value-for an individual cell's float-voltage, greater: than 2.07 volts, ensures the battery's capability to perform i its design function. I f .1 GRAND GULF-UNITJ1 B 3/4 8-2, AmendmentNo.11 -. ~ -.-