ML20059M369
| ML20059M369 | |
| Person / Time | |
|---|---|
| Issue date: | 09/11/1990 |
| From: | Hagan T NRC OFFICE OF ADMINISTRATION (ADM) |
| To: | Lofy R PARAMETER, INC. |
| Shared Package | |
| ML20059M365 | List: |
| References | |
| CON-FIN-L-1351, CON-NRC-03-89-029, CON-NRC-3-89-29 NUDOCS 9010040107 | |
| Download: ML20059M369 (5) | |
Text
.. m%
J,,
- j *,v.. T ),
' NUCLEAR REGULATORY COMMISSION :
l WASW NGT oN. D. C. 205s5
- s t
a
\\..... '
SEP 11 1990 L
Parameter, Inc.
ATIN:
Richard A. Lofy 13380 Watertown Plank Road Elm Grov9, Wisconsin 53122
Dear Mr. Lofy:
Subject:
Contract No. NRC-03-89-029, Task Order No. 8 Entitled " Vendor Inspection of Anchor / Darling" (FIN L-1351)-
i You are hereby authorized to commence work on'the subject task order.
effective September 11, 1990 with an established ceiling of $10,450.25.
In accordance with Section G.5, Task Order Procedures, of the subject contract, this letter definitizes Task Order No. 8.
This effort shall be l
performed in accordance with the enclosed Statement of Work and Parameter Inc. 's proposal dated Sept. ember 4,1990, incorporated herein by reference The period of performance for Task Order No.~ 8 is September 11, 1990 through October 5, 1990.
The total cost ceiling.is $10,450.25.
The amount i
of $10,168.48 represents the total reimbursable costs, the amount of $11.77 i
represencs the facilities capital cost of money, and the amount of $270.00 represents the fixed fee.
Accounting data for Task Order No. 8 is as follows:
B&R No.:
020-19-14-03-0 l
FIN No.:
L-1351 y
Appropiation No. :
31X0200.200 Obligated Amount:
$10,450.25 The following individual is considered by the Government to be essential to the successful performance of the work hereunder:
D. Jew i
The contractor agrees that such personnel shall not be removed from the effort under this task order without compliance with Contract Clause tl.1 -
Key Personnel.
i 9010040107 900915 PDR CONTR NRC-03-89-029 PDC
f.
Richard A. Lofy-NRC-03-89-029 Task Order No. 8 l
Page 2 of 2 The issuance of this task order does not amend any terms or conditions of the subject contract.
Acceptance of Task Order No. 8 should be made by executing three copies of this document in the space provided and returning two copies to the Contract Administrator.
You should retain the third copy for your records.
Should you have any questions regarding this matter, please feel-free to l'
contact Brenda DuBose, Contract Management Assistant, on (301) 492-7442.
Sincerely, 1
ll?l!<
E Timothy F. I gan, Contracting Officer Contract Ad inistration Branch No. 1 Division of Contracts and Property Management Office of Administration
Enclosure:
As stated i
ACC ED:
der No. 8 h
Up NAME
?kfltc DATE
7 g..
~
a STATEMENT OF WORK.FOR' TASK ORDER NO.' 8-UNDER CONTRACT NO. NRC-03-89-029 -(FIN L-1351)
TITLE:-
Vendor Inspection of Anchor / Darling Industries, incorporated Lead Inspector:
Robert L. Pettis=, Jr.
(301) 492-3214 Report No.:
99901115/90. NRR Priority No.:
1 i
BACKGROUND' NRC will conduct an' inspection of the vendor's program for providing snubbers l
to nuclear power plants and will specifically review the areas of quality assurance-(QA), procurement ~andequipmentqualification.
OBJECTIVE The objective of this Task Order is to~obtain technical expertise from Parameter, Inc. to assist the staff-in conducting a review and evaluation of
'./Dl's activities and programs.
WORK REQUIREMENTS Parameter, Inc. will provide one specialist with background and knowledge-in shock suppressor (snubber) qualification, design, testing, and repair with considerable experience in 10 CFR Part 50, Appendix B QA inspection 4
techniques to perform the work outlined below,
.l s
l Tasks Scheduled Completion i
1.
Prepare for the inspection by reviewing-September 13-14, 1990 l
background material at NRC Headquarters l
(Rockville, Maryland) as provided by the Lead inspector _
i i
2.
Review A/Ql's records relating to snubber-September.17-21, 1990 qualification, design, testing, and repair, y
Prepare input for the exit meeting.
t i
Specifically, the inspection will consist i
of examining:
i a.
Documentation, test reports and procedures which govern snubber l
qualification, design, testing, and repair activities at A/01 as' identified above.
-l i
I s
i 1
.1
N.
s 2<
l
~
Tasks (continued)-
Scheduled' Completion b.
Safety-related procurement documents and procedures that control A/Dl's procurement activities, c.
Review material purchase requests, approved vendor lists, material receipt inspection records, certificates of conformance and other related technical information as directed by.the Lead Inspector.
3.
Prepare input to the Inspection Report 'in September 28, 1990 the areas inspected in a format provided l
by the lead inspector.
LEVEL OF fff0RT AND PERIOD Of PERFORMANCE 5elevelofeffortisestimatedat12professionalstaffdaysapportionedas follows among the tasks for planning purposes:
Tasks Level of-Effort (Days) 1 2
2 5
i 3
5 TOTAL TE-The planning meeting is scheduled for September 13, 1990 while the inspection y
is scheduled fer the week of September 17, 1990. The period of performance is projected to be from September 11, 1990 to October 5,.1990.
l l
TECHNICAL REPORTING REQUIREMENTS 1.
At the completion of Task 2., provide summary notes of observations and findings pertinent to the inspection to the Lead Inspector. Provide a-summary of the cork performed in the Monthly Business Letter Report.
2.
At the completion of Task 3., submit a Technical Letter Report to-the Project Officer with a copy provided to the Lead Inspector and to the Contract Administrator that contains a suninary of the work performed, including observations, and findings in the areas inspected and any pertinent conclusions pertaining to the inspection activities conducted.
'f 8
l
. 3
(
(
t s _
MEETINGS AND TRAVEL One one-person, one-day trip to NRC Headquarters, Rockville, Maryland.
One rne-person, five-day trip to Anchor / Darling Industries, incorporated-located in Laconia, New Hampshire.
NRC FURNISHED MATERIALS Background information pertinent to this inspection will be provided to the Principal Investigator on September 13, 1990.
e
\\
l
.}
u Y
' l