1

~*

i

+

i GPU NuclearCorporation (J Nuclear

enes:reo o

Middletown Pennsylvania 17057-0191 717 944 7621 TELEX 84 2386 Writer's Direct Dial Number:

)

(717) 948-8400 November 12,1993

+

C312-93-2079 C000-93-2273 US Nuclear Regulatory Commission Attn: Do ument Control Desk Washington, DC 20555 i

i Three Mile Island Nuclear Station Unit 2 (TMI-2) l Operating License No. DPR-73 Docket No. 50-320 TA11-2 Radiation and Contamination Surveys

Dear Sir:

' nil-2 License Condition 2.F. requires, in part, the submittal of completed plant radiation and contamination surveys prior to entry into PDMS. The information contained in Enclosure 1

'I fulfills that ponion of the TMI-2 PDMS license condition.

The data in Enclosure I summarizes the extensive radiological surveys that were undenaken at TMI-2. The actual survey " maps" are contained in files located in the TMI Radiological Controls Depanment and are available for your review.

_i i

Sincerely,

,s t

/

7-R. L. Iong Director, Services Division /TMI-2 i

EDS/dib i

Enclosure i

cc:

M. G. Evans - Senior Resident Inspector, TMI T. T. Manin - Regional Administrator, Region I l

M. T. Masnik -_ Project Manager, PDNP Directorate L. H. Thonus - Project Manager, TMI 0

1oncs, 9311180290 931112 be gk PDR ADOCK 05000320 fM i

P PDR id GPU Nuclear Corporanon is a subsidia y of General Pubhc Ubhbes Corporation

/'

i j

~

i TMI-2 PDMS j

PLANT RADIATION AND CONTAMINATION SURVEY DATA I

Reactor Building Survey Summary Sheet Auxiliary / Fuel Handt:ng Building Survey Summary Sheet Overheads - Auxiliary /FuelIIandling Building Survey Summary Sheet t

Other Buildings Survey Summary Sheet i

Overheads - Other Buildings Survey Summary Sheet i

I i

i f

f L

i i

.)

I i

REACTOR BUILDING SURVEY $UMMARY SHEET

~

UPDATED 8/31/93 AREAS IN POMS==>

0 NUMBER OF EXCEPTIONS=====>

21 i

]

% EXCEPfl0NS=e==>

91.3%

NUMBER MEAN NUMBER 0F G.A.

OF

% OF AREA MEAN SHEAR NUMBER SMEAR SMEARS EXPOSURE nR/h NUMBER G.A.

PolNTS MEETING SMEAR T-TEST OF RESULT ABOVE RATE T-TEST OF mR/h ABOVE CONTAMINATIDN AREA ACTIVITY RESULTS SMEARS GOALS GOAL (in mR/h) RESULTS P0lNTS GOALS GOAL GDAL PASS / Fall 1

AREA At 84154 112403 39 < $0000 16 24.5 28.8 48 < 30 12 59.0% FAIL <<<<

I 2

AEEA B1 271060 399650 50 < 50000 26 37.6 40.6 43 < 100 0

48.0% FAIL <<<<

3 AREA C1 185267 233743 60 < 50000 40 51.3 58.8 44 < 100 2

33.3% Fall <<<<

4 AREA D1 331647 709931 17 < $0000 11 29.4 32.4 22 < 30 6

35.0% FAIL <<<<

5 AREA E1 675973 878653 74 < 50000 69 122.7 154.8 66 < 100 19 7.0% FAIL <<<<

j 6

AREA F1 3551907 5501740 43 < 50000 43 76.1 87.2 18 < 30 17 0.0% FAIL <<<<

7 AREA G1 41111 64092 18 < 50000 3

25.9 32.7 33 < 30 9

83.0% FAIL <<<<

8 AREA H1 61828 84904 29 < 50000 10 28.7 31.4 49 < 30 18 66.0% FAIL <<<<

9 AREA J1 646498 1366032 55 < 50000 21 22.8 25.1 73 < 30 11 62.0% FAIL <<<<

- 10 AREA K1 2828704 3868378 71 < 50000 66 119.4 158.3 103 < 100 16 7.0% Fall <<<<

{

11 AREA L1 132277 265912 47 < 50000 12 66.6 76.5 57 < 100 6

74.0% FAIL <<<<

12 AREA M1 9310933 15095799 15 < 50000 15 77.1 90.7 24 < 100 5

0.0% Fall <<<<

13 AREA N1 1155023 2189771 44 < 50000 22 271.1 496.5 75 < 100 21 50.0% FAIL 14 AREA P1 1072581 1473724 31 < $0000 30 139.4 150.8 78 < 100 53 3.0% FAIL <<<<

15 AREA 01 1019043 1401646 23 < 50000 23 170.4 221.7 25 < 100 14 0.0% Fall <<<<

16 AREA T1 681000 804616 47 < 50000 47 30.3 34.1 26 < 30 6

0.0% FAIL <<<<

17 ALL STAIRS 376061 513894 82 < 50000 46 97 110.7 64 < 100 23 44.0% FAIL <<<<

18 ENCLOSED S.W.

27692 33535 26 < 50000 2

60.2 75.6 22 < 100 4

92.0% PASS 19 DPEN 5.W.

642543 870331 46 < 50000 39 127.3 150.0 31 < 100 18 15.0% FAIL <<<<

l 20 TEMP. STAIRS 56000 75930 10 < 50000 5

85.5 95.3 11 < 100 1

50.0% FAIL <<<<

21 MISC. R.V.

N/A N/A N/A N/A N/A 867500.0 '964268.6 12 N/A N/A h/A N/A 22 MISC.-BASEMENT N/A N/A N/A N/A N/A 83000.0 204439.5 13 N/A N/A N/A N/A 23 MISC.-EV.EQ.RM 212000 298969 5 < 50000 5

42.5 46.8 6 < 30 6

0.0% FAIL <<<<

24 MISC. SERV.CR.

208889 270923 9 < 50000 9

21 25.9 4 < 30 0

0.0% FAIL <<<<

25 D-RINGS 2758613 4862970 15 N/A N/A 1655.7 2839.0 51 N/A N/A N/A N/A l

I I

b 4

k t

r i

THI - 2 REACTOR BUILDIt1G f

305' ELEVATION

u. -_ p g 1-

/

~.

~,

Li

/

AHEA DESCHIPTIOti Hi

/p Is 1 305* CI.EV CPT - 1A

'/

To Pcason4EL llATCll NI l

1.1 305* lioin'T A14CA *

- l l

l TO OPEtt STAIRWEl.i.

l fil 30$' IIIGli H AD ABCA 5

Ut1 DER CFT - B 5

g g

~

lil 30S' PERSotitsCL

~

IIATCil TO CFT - D

~

01 p3 3ns, orcri siATcia TO A1H COOLER AHEA

~

Q1 305' ItiCORC CilASE TO EQUIPHENT llATCil Ki

[

l l

3 l

l l

D Y

1 T

tA I

4 1

T L

O S

S l BC YI T

DA i

/

l A

D 3t E EC A

0A 6

b V

AL AR GT l

DF E

3 J

U EO A

AA t

i AH L

HF D

Hl l 1 t

l A

i DH C

AI I Y O l At o

A DA T0 4

t l

C l

KA TN SC l

T l

AG AG F

CA SW SE L

E) l P

l I

l J

4 O

HM H

P YD 1

A VI VI E

O GI DO D

Aw

  1. s t l n rP ER ER P

l M CS AA A

AD Ro C

rE L -

L -

O "R

ll C OT l

E1 Cn CO S

CR CD CD T

8O IW CS iT HA S

E T

I D

D L

'V R

V

  • F T

N A

A AT 7O 9E 9E 7A "A

7D 7E 7E 7E Lo 4O 4L 4L 6l 3L 43 4P 4R 4R Oi i

t t

3T 3E 3E 3S 3P 3A 3O 3A 3A Pt A

E l

l 1

1 l

1 1

i J

l a

A u

C D

F G

l J

T l

A

~

GS 1 O d[Ge=

1 i

'~

E i

G i

1 t s

=

D. T I

I M

IA UV DE LE t

I l

B O

9gY i

T' C7 H

A6

&D E3 A

1 I

D F

2N A

I7 4

~

!T3 l

l I

l pJ i

l I

l g

M l

l C

s

/

/i D

i l

A

4 Aux /FHB SURVEY

SUMMARY

SHEET UPDA'iE0 11/11/93 1

CUBICLES / AREAS IN PDMS=*>

136 No. OF EXCEPf!ONSas=>

19 NUMBER WRITTEN======>

20 *

% EXCEPflDNSama=>

14.0%

NUMBER MEAN NUMBER

(

OF G.A.

OF MEAN SMEAR NUMBER SMEAR SMEARS EXPOSURE mR/h NUMBER C.A.

PolNTS t

LMEAR 1-TEST OF RESULT ABOVE RATE T-TEST OF mR/h ABOVE

(

RDOM ACTIVITY RESULTS SMEARS GOALS GDAL (in mR/h) RESULTS POINTS GOALS GDAL PASS / FAIL F

1 Ax001 592 819 165 < 1000 15 1.5 2.2 76 < 2.5 10 PASS i

2 Ax001a 80739 179781 23 < 1000 17 2.4 2.9 9 < 2.5 5 FAIL

  • 3 Ax002 112 128 200 < 1000 1

1.5 2.2 90 < 2.5 6 FASS 4 Ax002a 105 119 32 < 1000 0

1.8 2.5 12 < 2.5 3 PASS r

1 5 Ax003 2944 4791 159 < 1000 46 0.8 1

63 < 2.5 4 FAIL 6 Ax004 68385 95673 26 < 50000 10 116.0 1 79.0 10 < 1000 0

Fall' <<<<

{

7 Ax005 39982 56587 57 < 50000 13

7. 7 11.2 16 < 500 0 PASS 8 Ax006 87533 162807 45 < 50000 9

58.0 82.0 13 < 500 0 FAIL <<<<

9 Ax007 9195 12729 41 < 50000 0

37.0 57.0 to < $00 0 PASS l

10 Ax008 958762 1414103 21 "As !$"

N/A 712.2 1104.9 40 "A$ IS" N/A PASS 11 Ax009 2976667 5523733 3

"AS IS" N/A 1736.4 2358.0 11 "A$ IS" N/A PASS 12 Ax010 1366320 2007944 25 "AS IS" N/A 181.3 248.8 40 "AS !$" N/A PASS 13 Ax011 3233 5047 30 < 5000 5

8.0 10.3 8 < 50 0 PASS f

14 Ax012 392407 923368 27 < 5000 27 560.0 740.5 10 < 50 10 FAIL <<<<

15 Ax013 133 1 74 84 < 1000 1

5 9.5 38 < 500 0 PASS 16 AX014 20300 31485 80 < 50000 5

17.5 23.4 34 < 500 0 PASS 17 Ax015a 10412 16400 34 < 50000 1

114.2 161.9 28 < $00 1 PASS 18 Ax015b 21222 34288 36 < 50000 4

37.7 51.9 26 < 500 0 PASS l

19 Ax016 21222 34288 36 < 50000 4

37.7 51.9 26 < 500 0 PASS 20 Ax017 10412 16400 34 < 50000 1

114.2 161.9 28 < 500 1 PASS t

21 Ax018 17233 29738 60 < 50000 4

10.4 14.7 26 < 500 0 PASS 22 Ax019 7750 12458 24 < 50000 1

18.8 35.4 9 < 500 0 PASS

{

23 Ax020 521859 1139946 64 < 50000 25 155.8 191.1 40 < 500 1

FAIL 24 Ax021 1805 2650 195 < $0000 1

17.6 21.9 80 < $00 0 PASS p

25 Ax022 443 467 26 < 1000 0

0.3 0.4 37 < 2.5 0 PASS

{

26 Ax023 24598 64278 32 < 50000 1

14.4 17.5 5 < 10 5

FAIL <<<<

27 AXO24 6433 11354 34 < 50009 1

15.3 19.7 11 < 500 0 PASS E

28 Ax025 1007 1864 36 < 1000 3

3.5 5

18 < 500 0 Fall <<<<

j 29 Ax026 9028 19090 1B < 50000 1

12.1 18.6 15 < 500 0 PASS r

30 Ax027 476 494 32 < 1000 0

0.2 0.2 16 < 2.5 n PASS 31 Ax101 86 86 62 < 1000 0

0.2 0.2 22 < 2.5 0 PASS 32 Ax102 9264 12543 22 < 50000 0

47.4 63.6 7 < 1000 0 PASS

[

33 Ax103 469 482 23 < 1000 0

0.2 0.2 12 < 2.5 0 PASS

~ {

34 Ax104 4 71 548 25 < 1000 0

0.2 0.2 13 < 2.5 0 PASS J

35 Ax105 480 480 53 < 1000 0

0.2 0.2 25 < 2.5 0 PASS 36 Ax106 480 480 56 < 1000 0

0.2 0.2 30 < 2.5 0 PASS 5

37 Ax107 464 483 45 < 1000 0

0.2 0.2 17 < 2.5 0 PASS 38 Ax108 477 482 43 < 1000 0

0.2 0.2 19 < 2.5 0 PASS 39 Ax109 96 97 120 < 1000 0

0.2 0.2 32 < 2.5 0 PASS l

40 Ax110 100 1DB 137 < 1000 0

0.2 0.3 17 < 2.5 0 PASS l

41 AX111 439 4 64 40 < 1000 0

0.7 1.0 19 < 50 0 PASS i

42 AX112 347609 695004 69 < 50000 22 99.2 165.1 22 < 1000 0 FAIL <<<<

t 43 Ax113 22380 38974 71 < 50000 5

18.6 38.9 17 < $0 1 PASS 44 Ax114 9820 12402 62 "As IS" W/A 72752.8 99575.5 18 "AS IS" N/A PASS 45 Ax115 31128 56155 69 "AS IS" N/A 68169.2 109381.8 13 "AS IS" N/A PASS 46 Ax116 313652 687389 69 < $0000 8

59.7 E3.8 27 < $00 0 Fall <<<<

f 47 Ax117 330872188 8.5E+08 8

  • AS IS" N/A 935 1491 10 < 1000 3 PASS

[

48 Ax118 1000 1000 60 < 1000 0

1.1 1.4 32 < 2.5 1 PASS l

49 AX119 477 822 43 < 1000 4

0.4 0.7 10 < 2.5 0 PASS 50 Ax120 355 493 38 < 1000 4

0.6 0.9 13 < 2.5 0 PASS l

51 Ax121 248 3 77 17 < 1000 1

0.3 0.4 5 < 2.5 0 PASS 52 Ax122 465 465 23 < 1000 0

0.2 0.2 21 < 2.5 0 PASS 53 tX123 158 194 200 < 1000 4

0.2 0.3-98 < 2.5 0 PASS f

~.

j 54 Ax124 3269 5316 26 < 50000 0

3.3 4.5 6 < 500 0 PASS 55 Ax125 1026 1069 154 < 50000 0

0.2 0.2 40 < 500 0

PASS-56 Ax126 98 103 44 < 50000 0

0.2 0.2 15 < 500 0 PASS 57 Ax127 6363 11952 161 < 50000 3

0,6 1

50 < 500 0 PASS

)

58 Ax120 1009 1025 108 < 50000 0

2,7 4.9 23 < 500-0 PASS

{

59 Ax129 1013 1027 32 < 5000C 0

0.3 0.4 11 < 500 0 PASS l

60 Ax130 535 535 56 < 50000 0

0.5 0.7 27 < 500 0 PASS 61 Ax131 1892 2351 50 < 5000 6

121.6 180.6 11 < 50 9 FAIL <<<<

62 Ax132 104 109 630 < 1000 0

0.2 0.2 109 < 2.5 0 PAS $

)

63 Ax133 495 495 28 < 1000 0

0.2 0.2 16 < 2.5-0 PASS 64 Ax134 12868 23615 41 < 50000 2

13.1 20.1 10 < 50 0 PASS 65 Ax135 125 136 69 < 1000 0

0.2 0.2 9 < 2.5 0 PASS i

66 AX201 450 476 20 < 1000 0

0.2 0.2 17 < 2.5 0 PASS 67 Ax202 480 480 56 < 1000 0

0.2 0.3 5 < 2.5 0 PASS

.i 68 Ax203 4"

480 27 < 1000 0

0.2 0.2 18 < 2.5 0 PASS l

69 Ax204 464 480 33 < 1000 0

0.2 0.2 16 < 2.5 0 PASS 70 Ax205 96 97 124 < 1000 0

0.7 0.9 61 < 2.5 2 PASS I

71 Ax206 195321 387196 28 N/A N/A 10.2 13.8 18 < 50 0-PASS 72 AX207 197143 348210 28 N/A N/A 12.8 18.5 17 < 50 0 PASS 73 AX208 3893 6897 28 N/A N/A 0.4 0.5 17 < SO O PASS 74 AX209 10250 16581 28 N/A N/A 0.7 1.0 18 < 50 0 PASS 75 AX210 12250 19946 28 N/A N/A 0.9 2.1 18 < 50 0 PASS 76 Ax211 7196 11544 28 N/A N/A 0.3 0.3 15 < 50 0 PASS 77 AX212 95 99 135 < 1000 0

0.2 0.3 50 < 2.5 0 PASS 78 AX213 127 1 73 161 < 1000 1

0.2 0.2 40 < 2.5 0 PASS 79 AX214 145 180 100 < 1000 1

0.3 0.3 40 < 2.5 0 PASS 80 AX214a 4430 7326 24 < 1000 16 0.4 0.5 8 < 2.5 0 FAIL

  • i 81 AX215 450 450 17 N/A N/A 0.2 0.2 11 < 2.5 0 PASS 82 AX216 450 450 17 N/A N/A 0.2 0.2 13 < 2.5 0 PASS 83 Ax217 115 127 156 < 1000 0

0.2 0.2 46 < 2.5 0 PASS 84 Ax218 1860 2590 50 < 50000 0

15.2 24.5 13 < 500 0 PASS 85 AX219 393 743 115 < 1000 5

0.3 0.5 67 < 2.5 1

PASS 86 Ax220 437 452 45 < 1000 0

1.4 2.2 18 < 500 0 PASS 87 AX221 445 451 73 < 1000 0

0.8 1.5 26 < 500-0 PASS 88 AX222 104 104 10 < 1000 0

0.2 0.2 3 < 2.5 0 PASS 89 Ax223 493 493 130 < 5000 0

0.8 1.1 38 < 2.5 5 PASS r

90 Ax301 98 130 29 < 1000 0

0.2 0.2 13 < 2.5 0 PASS 91 Ax302 480 480 20 < 1000 0

0.2 0.2 12 < 2.5 0 PASS 92 Ax303 505 505 96 < 1000 0

0.2 0.2 16 < 2.5 0 PASS 93 Ax304 74 5 1161 20 < 1000 0

0.6 0.9 4 < 2.5 0 PASS 94 Ax305 652 945 22 < 1000 0

0.2 0.2 13 < 2.5 0 PASS 95 Ax401 93 93 512 < 1000 0

0.2 0.2 1 73 < 2.5 0 PASS 96 Ax402 113 130 75 < 50000 0

0.2 0.2 38 < 500 0 PASS 97 Ax403 115 129 58 < 50000 0

0.2 0.2 21 < 500 0 PASS 98 Ax501 365800 873244 10 < 5000 9

16.8 22.7 11 < 25 2 Fall u"

99 Ax502 113596 154187 89 *AS IS" N/A 30.6 37.1 31 < 25 15 FAIL ""

'I 100 Ax503 43267 97184 15 < 50000 1

11.1 15.8 17 < 25 1

PASS 101 Ax504 15250 22291 76 < $0000 6

6.1 7.3 19 < 25 0 PASS

[

102 FH001 70113 112275 53 *AS IS" N/A 18.9 30.7 13 < 500 0 PASS 103 FH002 1000 1000 47 < 1000 0

1.5 2.3 15 < 2.5 5 PASS 104 FH003a 140690 197160 58 < 50000 34 68.6 80.0 14 < 1000 0 FAIL uu 105 FH0036 510545 918754 84 < 50000 33 221.3 302.1 38 < 1000 1

Fall ""

l 106 FH004 37717 89124 46 < $0000 1

59.3 112.0 32 < 500 1

PASS 107 FH005 2714 3863 21 < 50000 0

2.4 3.5 8 < $00 0 PASS 108 FH006 1063 1487 190 < 1000 26 6.4 13.3 73 < 500 0 FAIL uu 109 FH007 100 105 130 < 1000 0

0.8 1.3 40 < 500 0 PASS 110 FH008 21900 33253 50 < 50000 6

183.8 230.9 16 < 500 0 PASS 111 FH009 20730 34281 37 < 50000 3

146.5 207.7 11 < 500 0 PASS 112 FH010 2446 3413 28 < $0000 0

4.3 6.1 13 < 500 0 PASS i

113 FHD11 13944 23043 36 < 50000 3

9.1 11.9 11 < 500 0 PASS 114 FH012 2760 3786 50 < $0000 0

30.9 40.8 23 < 500 0 PASS 115 FH013 96 96 70 < 1000 0

0.2 0.2 28 < 500 0 PASS 116 FH014 35261 60400 23 < 50000 3

110.0 150.6 10 < 500 0 PASS j

117 FH101 847161 1865354 31 < 50000 25 202.0 263.2 10 < 500 0 FAIL uu i

118 FH102 203 233 105 < 1000 0

1.1 1.3 40 < 2.5 1 PASS 119 FH102a 384500 1189944 4 < 1000 4

4 N/A 1 < 2.5 1

FAIL

  • l 120 FH103 4029 7238 34 < 50000 1

1.2 1.9 15 < 50 0 PASS i

i 121 FN104 118 136 60 < 1000 0

0.2 0.2 18 < 2.5 0 PASS r

o y*-

n nv u-

,e

l

.\\

122 FH)D5 101 101 60 < 1000 0

0.2 0.3 34 < 2.5 0 PASS 123 FH105a 22400 58583 10 < 1000 7

21.3 36.2 4 < 2.5 4 FAIL

  • 1 124 FH106 329 499' 114 < 1000 6

0.7 0.9 12 < 2.5 0 PASS 1

125 FH107 104 108 27 < 1000 0

0.2 0.2 12 < 2.5 0 PASS

)

126 FH108 71 71 69 < 1000 0

0.2 0.2 31 < 2.5 0 PASS 1

127 FH109 54859411 75901788 56 "As IS" N/A 234.7 278.2 120 "AS IS" N/A PASS 128 FH110 175600 213839 20 < 1000 20 6.9 9.9 1B < 2.5 13 FAIL- ""

i 129 FH111 146667 239534 12 < 1000 12 0.3 0.5 4 < 1000 0 FAIL <"<

130 FH112 3524 6356 53 < 50000 1

19.3 32.0 17 < 100 1 PASS 131 FH201 424 480 75 < 1000 1

1.0 1.2 40 < 2.5 3 PASS 132 FH202 483 543 42 < 1000 2

0.2 0.2 11 < 2.5 0 PASS 133 FH203 1000 N/A 1 < 50000 0

27.9 32.9 9 < 500 0 PASS j

134 FN204 1000 1000 72 < 1000 0

0.2 0.2 30 < 500 0 PASS 135 FH205 695 919 59 < 50000 0

B.7 13.7 18 < 100 0 PASS 136 FH301 241 457 90 < 1000 2

3.9 4.4 46 < 2.$

34 FAIL ""

-l 137 FH302 481 564 200 < 1000 4

1.2 1.6 40 < 2.5 6 PASS

{

138 FH303 303 420 200 < 1000 7

0.2 0.2 74 < 2.5-O PASS 139 FH304 2205 3660 22 < 50000 0

0.6 0.7 1D < 500-0 PASS 140 FH305 392 625 154 < 1000 6

1.3 1.8 66 < 2.5 5 PASS For the purposes of this table, f our shielded / enclosed areas within cubicles were separated from their parent cubicle and a single exception written.

l Therefore, there were 19 exceptions written for individual cubicles and one

[

combined exception written f or the four enclosed / shielded areas within cubicles.

t i

i i

a 5

9 j

h b

l t

i

~

a.

I

)

I OVERHEADS AUX /FHB SURVEY

SUMMARY

SHEET 11/11/93 a

i NUMBER OF ROOMS MEETING OVERHEAD PDMS SAR GOALS >

105

% Meeting PDMS SAR Requirementsan=>

90%

1 NOTE 1: One generic exception was written for all AFHS overheads.

NOTE 2: Cubicles with "M" designator are overheat mezzanines.

NOTE 3: A mean smear activity denoted by an **" was calculated by adding 2-Sigma to the mean smear value below 7',

j NUMBER n

OF MEAN SMEAR NUMBER SHEAR SMEARS SMEAR T-TEST OF RESULT ABOVE ROOM ACTIVITY' RESULTS SMEARS GOALS-GOAL PASS / FAIL 1 Ax001 2450 3987 12 < 10000 1

PASS 2 Ax001a 6500 41227 2 < 10000 1

PASS 3 Ax002 1263 1810 10 < 10000 0 PASS 4 Ax002a N/A N/A N/A N/A N/A 5 Ax003 2298 3913 16 < 10000 1

PASS 6 Ax004 754500 1468783 4 < 50000 4

Fall 7 Ax005 29600 53051 15 < 50000 3 PASS 8 Ax006 28667 61760 3 < 50000 0 PASS 9 Ax007 21222 30312 9 < 50000 0 PASS 10 Ax008 3378050*

"AS IS" PASS I

11 Ax009 5998344*

"AS IS" PASS i

12 Ax010 5116317*

"AS IS" PASS i

13 Ax011 4900 6722 10 < 50000 0 PASS 14 Ax012 67500 171732 4 < 50000 1

FA]L 15 Ax013 138 226 4 < 10000 0 PASS 16 Ax014 8100 12684 10 < 50000 0 PASS 17 Ax015e 8667 10613 3 < 50000 0 PASS 18 Ax015b 13000 24073 16 < 50000 1

PASS 19 Ax015-M 5534 7769 44 < 50000 0 PASS 20 Ax016 13000 24073 16 < $0000 1 PASS 21 Ax017 8667 10613 3 < 50000 0 PASS 22 Ax018 14444 20192 18 < 50000 1

PASS 1

23 AX019 5692 7153 13 < 50000 0 PASS 24 Ax020 202111 326398 9 < 50000 5

FAIL I

25 Ax021 11579 14897 19 < 50000 0 PASS 26 Ax022 N/A N/A N/A N/A N/A 27 Ax023 N/A N/A N/A N/A N/A 28 Ax024-M 10775 17483 12 < 50000 0 PASS 29 AX025 311 577 10 < 10000 0 PASS 30 Ax026 1077 1214 13 < 50000 0 PASS

^

31 Ax027 N/A N/A N/A N/A N/A 32 Ax101 110 156 8 < 10000 0 PASS 33 Ax102-M 4164 7049 75 < 50000 2 PASS i

34 Ax103 478 553 10 < 10000 0 PASS 35 Ax104 471 548 10 e 10000 0 PASS 36 Ax105 530 530 to < 10000 0 PASS 1

37 Ax106 530 530 10 < 10000 0 PASS 1

38 Ax107 530 530 10 < 10000 0 PASS 39 Ax108 501 554 10 < 10000 0 PASS 40 AX109 128 159 10 < 10000 0 PASS 41 Ax110 129 182 to < 10000 0 PASS 42 Ax111 406 478 10 < 10000 0 PASS 43 Ax112 37800 83029 5 < $0000 1 PASS 44 Ax113 6400 11336 5 < 50000 0 PASS 45 Ax114 34078*

"AS IS" PASS 46 Ax115 279586*

  • AS IS" PASS 47 AX116 23143 40242 7 < 50000 2 PASS 48 Ax117 M 2414 3252 29 < 50000 0 PASS 49 Ax118 3017 6224 11 < 10000 1

PASS 50 Ax119 332 564 12 < 10000 0 PASS

.~

51 Ax120-M 1045 1930 50 < 10000 1

PASS i

52 Ax121 N/A N/A N/A N/A N/A 53 Ax122 N/A N/A N/A N/A N/A I

54 Ax123 139 178 25 < 10000 C PASS f

$5 Ax124 1846 2290 13 < 50000 0 PASS f

56 Ax125 1000 1000 11 < 50000 0 PASS t

57 Ax126 155 226 11 < 50000 0 PASS 58 Ax127 691 1201 20 < $0000 0 PASS 59 Ax128 1273 1767 11 < 50000 0 PASS I

60 Ax129 598 736 13 < 50000 0 PASS i

61 Ax130 519 540 8 < 50000 0 PASS 62 Ax131 6500 11599 10 < 50000 0 PASS 63 AX132 97 99 10 < 10000 0 PASS

{

64 Ax133 N/A N/A N/A N/A N/A 65 Ax134 45457 909%

14 < 50000 2 PASS 66 Ax135 115 128 20 < 10000 0 PASS 67 Ax201 N/A N/A N/A N/A 0.

N/A l

68 Ax202 480 480 5 < 10000 0 PASS j

69 AX203 455 501 11 < 10000 0 PASS 70 Ax204 480 480 14 < 10000 0 PASS f

71 Ax205 129 174 17 < 10000 0 PASS 72 AX206 N/A N/A N/A N/A N/A f

73 Ax207 N/A N/A N/A N/A N/A 74 AX208 N/A N/A N/A N/A N/A l

75 Ax209 N/A N/A N/A N/A N/A f

76 Ax210 N/A N/A N/A N/A N/A f

77 Ax211 N/A N/A N/A N/A N/A 78 Ax212 93 93 20 < 10000 0 PASS 79 AX213 117 147 15 < 10000 0 PASS 80 AX214 96 96 10 < 10000 0 PASS 81 Ax215 N/A N/A N/A N/A N/A 82 AX216 N/A N/A N/A N/A N/A e

83 AX217 374 479 14 < 10000 0 PASS f

84 Ax218 1000 1000 0 < 50000 0 PASS 85 AX219 5878 10156 10 < 10000 2 PASS 86 Ax220 357 604 10 < 10000 0 PASS 87 Ax221 878 1349 16 < 10000 0 PASS 88 AX222 N/A N/A N/A N/A N/A s

89 AX223 448 525 10 < 10000 0 FASS 90 Ax301 168 225 10 < 10000 0 PASS 91 AX302 480 480 5 < 10000 0 PASS 92 Ax303 505 505 21 < 10000 0 PASS 93 Ax304 505 505 2 < 10000 0 PASS 94 Ax305 388 1129 2 < 10000 0 PASS 95 Ax401 N/A N/A N/A N/A N/A 96 Ax402 231 362 10 < 50000 0 PASS i

97 Ax403 127 158 10 < 50000 0 PASS 98 Ax501 2116677*

< 50000 FAIL 99 Ax5b2 537437*

  • AS 15" PASS 100 Ax503 280427'

< 50000 FAIL I

101 Ax504 88735*

< 50000 FAIL i

102 FN003 89143 168519 7 < 50000 2 FAIL 103 FH002 1455 2278 11 < 10000 0 PASS 104 FH003a 76667 130400 6 < 100000 2 PASS 105 FN003b 180000 306280 2 < 100000 2 FAIL 106 FH004 1124769 3052021 13 < 50000 3 FAIL 107 FH005 1500 2677 4 < 50000 0 PASS 108 FH006 1418 1875 26 < 10000 0 PASS 109 FH007 459 666 12 < 10000 0 PASS j

110 FH008 4650 9243 1b < 50000 0 PASS 111 FH009 8250 14792 4 < 50000 0 PASS 112 FHD10 6250 9669 12 < 50000 0 PASS 113 FH011 19500 43525 4 < 50000 1 PASS 114 FH012-M 1163 1620 40 < $0000 0 PASS 115 FH013 96 96 10 < 10000 0 PASS l

116 THD14 7500 10657 2 < 50000 0 PASS 117 FN101 14100000 31905480 2 < $0000 2 FAIL i

118 FH102 31369 45343 10 < 10000 8 FAIL

i 119 FH103 1600' 2223 to < 50000 0 PASS i

120 FH1D4

.103 105 12 < 10000 0 PASS 1

121 FH105 101 101 10 < 10000 0 PASS i

1 122 FH106 107 118 28 < 10000 0 PASS 1 23 FH107 129 155 10 < 10000 0 PASS 3

124 FH108 71 71 11 < 10000 0 PASS 125 FH109 N/A N/A N/A N/A N/A 126 FH110 N/A N/A N/A N/A N/A I

127 FH111 N/A N/A N/A N/A N/A 128 FN112 843 2172 7 < 50000 0 PASS 129.FH201 9356 18629 10 < 10000 2 PASS 130 FH202 492 497 3 < 10000 0 PASS I

131 FH203 INACCES$1BLE

< 50000 FAIL 132 TH2D4 1000 1000 9 < 10000 0 PASS 133 FH205 S450 13559 7 < 50000 0 PASS 134 FH301 298 1513 2 < 10000 0 PASS 135 FH302 402 475 20 < 10000 0 PASS l

136 FH303 155 208 17 < 10000 0 PASS 137 FH304 2167 3454 3 < 50000 0 PASS I

138 FH305 900 1663 17 < 10000 0 PASS P

I l

1 r

I l

1 1

E 1

I

'l i

t SB Q!SC. OR OTHER AREAS SU3VEV SUMMAR7 SHEET SMEQR REMOVAL EFFICIENCT==>

10%

UPDATEp' 11/11/93 1

J NUMBER OF EXCEPTIONS=====>

2 i

% EXCEPTIONS====>

10.0%

NUMBER MEAN NUMBER 0F G.A.

OF ESilMATED TOTAL f

MEAN SMEAR NUMBER SMEAR SMEARS EXPOSURE nR/h NUMBER G.A.

POINTS SURFACE SMEARABLE ROOM SMEAR T-TEST OF RESULT ABOVE RATE T-TEST OF mR/h ABOVE AREA ACTIVITY l

OR AREA ACTIVITY RESULTS SMEARS GOALS GOAL (in FA/h) RESULTS folNTS GOALS GOAL PASS / FAIL (Cl)

.............................................................................................................(ft*2) j

$8000 SERVICE BUILDING 281' Lt.

j 28158000 89 89 188 < 1000 0

0.2 0.2 80 < 2.5 0 PASS 16911 6.30E-05 281SB001 140 172 45 < 1000 0

0.5 0.6 18 < 2.5 0 PASS 2767 1.62E-05 28158003 99 106 194 < 1000 0

0.6 0.8 110 < 2.5 3 PASS 12424 5.15E-05 TOTAL==> 1.31E-04 TB000 TURBINE BUILDING 281' El.

281TBWEQ 96 96 87 < 1000 0

0.2 0.2 59 < 2.5-U PASS 36340.1.46E-04 281TsNWQ 93 93 118 < 1000 0

0.2 0.2 40 < 2.5 0 PASS 36340 1.41E-04 281TBSEQ 98 98 120 < 1000 0

0.2 0.2 43 < 2.5 0 PASS 36340 1.49E-04

'281TBSWQ 101 101 154 < 1000 0

02 0.2 40 < 2.5 0 PASS 36340 1.54E-04 TOTAL==> 5.90E- 04 SS100 SERVICE BUILDING 305' El.

SB10000A 111 117 200 < 1000 0

0.2 0.2 45 < 2.5 0 PASS 3000 1.39E-05 i

30558100 98 99 154

< 1000 0

0.2 0.2 40 < 2.5 0 PASS 14220 5.83E-05 TOTAL==> 7.23E-05 SB100 Secondary themistry Laboratory 305' El.

305SB102 1733 3140 200 < 1000 16 0.2 0.2 34 < 2.5 0 FAIL <<<<

5250 3.81E-04 QA104 BWST AREA 305' El.

BWST-AREA 93 93 40 < 1000 0

0.3 0.4 36 < 2.5 0 PASS 1840 7.16E 06 BWST PH 97 103 34 < 1000 0

0.2 0.2 11 < 2.5 0 PASS 1135 4.61E-D6 BWST-VM 94 96 90 < 1000 0

0.2 0.2 24 < 2.5 0 PASS 4439 1.75E-05 TOTAL==> 2.92E-05 PA108 CACE Building 305' El.

CACE BLDG 103 108 123 < 1000 0

0.4 0.4 77 < 2.5 0 PASS 6231 2.69E-05 RA101 NST Pum House Area 305' El.

PWST AREA 121 125 121

< 1000 0

0.2 0.2 40 < 2.5 0 PASS 5369 2.72E 05 RA101 PWST Su m 305' El.

l PWST SUMP 118 118 30 < 1000 0

0.3 0.2 12 < 2.5 0 PASS 513 2.53E-06 SB002 M-20 Area 281' El.

SB002M 20 107 108 200 < 1000 0

0.2 0.3 40 < 2.5 0 PASS 26000 1.16E 04 0 SB002 M 20 Area Sump 281' El.

0-20 SUMP 1000 1000 4 < 1000 0

0.3 0.4 3 < 2.5 0 PASS 249 1.04E-05

~

1 $B100 RB Containment Control cubicle 305' El.

SB100a(C3) 1254 1808 81

< 1000 18 0.2 0.2 18 < 2.5 0 FAIL <<<<

1090 5.72E-05 2 59500 Tendon Access Gallery 258' El.

SB500-TAG 107 107 129 < 1000 0

0.3 0.4 40 < 2.5 0 PASS 1.22E-04

.............................................................................................................27200 TOTAL Cl==>

1.57E-03 f

I

DVER P*, ADS 58 & MISC OTHER AREAS SURVEY

SUMMARY

SHEET 11/12/93 WUMBER OF MEAN SMEAR NUMBER SMEAR SMEARS ROOM SMEAR T-TEST OF RESULT ABOVE OR AREA ACTIVITY RESULTS SMEARS COALS COAL 1 281SB000 92 96 12 < 10000 0

2 281SB001 8 72 1833 to < 10000 0

3 281SB003 110 148 11 < 10000 0

4 281TBNEQ 96 96 10 < 10000 0

5 281TBWVQ 93 93 12 < 10000 0

6 281TBSED 98 98 16 < 10000 0

7 281TBSWQ 101 101 11 < 10000 0

8 305S8100 100 108 10 < 10000 0

9 3055B102 135 168 19 < 10000 0

10 AIR INTAKE 101 101 11 < 10000 0

11 BWST-PH 93 93 6 < 10000 0

12 BWST-VM 93 93 16 < 10000 0

13 CASE BLDG 100 103 12 < 10000 0

14 PWST AREA 107 107 10 < 10000 0

15 SB002M-20 107 113 12 < 10000 0

16 SB100a(C3) 4042 5993 15 < 10000 2

17 58100DGA 437 666 54 < 10000 0

18 SB500-TAG 107 107 15 < 10000 0

19 281CB000 100 100 9 < 10000 0

6