ML20059M107

From kanterella
Jump to navigation Jump to search
Forwards SER Accepting Category 3 Qualification in Lieu of Category 2 Qualification for Pressure Monitoring Instrumentation,Per GL 82-33 & Reg Guide 1.97,Rev 2
ML20059M107
Person / Time
Site: North Anna  Dominion icon.png
Issue date: 11/15/1993
From: Engle L
Office of Nuclear Reactor Regulation
To: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
Shared Package
ML20059M109 List:
References
RTR-REGGD-01.097, RTR-REGGD-1.097 GL-82-33, NUDOCS 9311180163
Download: ML20059M107 (3)


Text

[,.

~

Novnber 15, 1993 s

Docket Nos. 50-338 and'50-339 Mr. W. L. Stewart Senior Vice President - Nuclear Virginia Electric and Power Co.

d 5000 Dominion Blvd.

Glen Allen, Virginia 23050

Dear Mr. Stewart:

SUBJECT:

'.NSTRUMENTATION TO FOLLOW THE COURSE OF'AN ACCIDENTL(REGULATORY-

^

GUIDE 1.97) - NORTH ANNA POWER STATION, UNIT NOS. 1 AND.2 (NA-1&2):

Section 6.2 of Generic Letter 82-33 requested lice'nsees to provide a report on"

~

their impicmentation of Regulatory Guide 1.97 (Revision 2), including 1 methods'-

for complying with the Commission's regulations and supportirg technical justification for any proposed alternatives.or deviations..A_large number.'of exception requests were received from PWR licensees asking that the environmental qualification requirement for accumulator, level and pressure -

monitoring instrumentation be relaxed from Category 2 to' Category 3, which would allow commercial grade instruments to be used. Prior to 1987 thesei requests were denied by the staff. Since then, these~ exceptions have been.

considered as an open item until a generic resolution. can be found.

The staff has now reviewed the bases-for these exceptions:and has concluded that no operator action is based on this post-accident instrumentation and:

that it does not perform a safety function.: Since this' instrumentation does not perform any post-accident safety function, its qualification requirements-can be reduced to Category 3. _ A copy of the Safety Evaluation' is ' enclosed.

You have already installed Category 2 instrumentation to monitor accumulator level and pressure. You are no longer bound by this: commitment, and may, at.

your discretion, replace this instrumentation with Category instrumentation.

Ple se notify me of the actions _ you plan to take and 'the _ schedule 'for-implementation.

If you have any questions regarding this issue, please do not hesitate to' contact me at (301) 504-1480.

Sincerely, (Original Signed By)

Leon B. Engle, Project Manager Project Directorate II-2 Division of-Reactor Projects - I/II

Enclosure:

M.

As stated LA:PDII-2 D:

ETana 4ff LE

ms HB r l

cc w/ enclosure:

11/ 9

/93 11/16/93-11 93:

j See next page 9311100163 931115 PDR ADOCK 05000338 l

P PDR 170036 E0 IEE OE E c

.c Mr. W. L. Stewart North Anna Power Station Virginia Electric-1 Power Company Units I and.2-

-cc:

Pr. William C. Porter, Jr.

Robert B. Strobe,'M.D., M.P.H.

wanty Administrator State Health Commissioner:

L

.Louisa County Office of the Commissioner

-Louisa, Virginia 23093 _

Virginia Department of Health-P.O.-Box 160 P.O. Box 2448.

Richmond, Virginia 23218; Michael W.'Maupin, Esq.

Hunton and Williams Regional Administrator, RII L

~ Riverfront Plaza, East Tower U.S. Nuclear Regulatory Commission 951 E. Byrd Street 101 Marietta Street, N.W.,' Suite 2900'

~

. Richmond, Virginia 23219 Atlanta,: Georgia'30323 Dr. W. T.-Lough Virginia State Corporation Commission Mr. G. E. Kane, Manager Division of' Energy Regulation.

North Anna Power Station P.O. Box 1197 P.O. Box 402 Richmond, Virginia 23209 Mineral, Virginia 23117 Old Dominion Electric Cooperative 4201 Dominion Blvd.

Glen Allen, Virginia' 23060 Mr. M. L. Bowling, Manager

. Nuclear; Licensing & Programs

. Virginia Electric and Power Company Innsbrook Technical Center 5000 Dominion Blvd.

Glen Allen, Virginia 23060

-Office of the Attorney General Supreme Court Building 101 North 8th Street 1 Richmond, Virginia'23219 Senior Resident Inspector North Anna Power Station U.S. Nuclear Regulatory Commission Route 2, Box 78 Mineral, Virginia 231172 i

1 o

-i T

w