Text

- - - - -.

BALTIMORE GAS AND ELECTRIC

[

CALVERT CLIFFS NUCLEAR POWER PLANT 1650 CALVERT Ct.lFFS PARKWAY

  • LUSBY. MARYLAND 20657-4702 CHARLES H. CRUSE PL ANT GENERAL MANAGER CALVERT CUFFS November 12,1993 U. S. Nuclear Regulatory Commission Washington,DC 20555 ATTENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Powe. Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 October 1993 Operatine Data Reports The subject reports are being sent to you as required by Technical Specification 6.9.1.6.

Should you have any questions, please contact Mr. Bruce Mrowca at (410) 260-3989.

Very truly yours,

/,a 'd 6

,tsrt-CHC/FP,bjd Attachments cc:

D. A. Brune, Esquire J. E. Silberg, Esquire R. A. Capra, NRC D. G. Mcdonald, Jr., NRC T. T. Martin, NRC P. R. Wilson, NRC R. I. McLean, DNR J. II. Walter, PSC R. A. Hartfield, NRC P. Ixwis, INPO K. Larsen, ANI 180000 9311170478 931031 17 I I PDR ADOCK 05000317 C R

PDR kj

oco*************************************************************************

UNIT 1 OPERATING DATA REPORT oco*************************************************************************

Douxet No. 50-317 November 12, 1993 Prepared by Frank Piazza Telephone: (410) 260-3821 OPERATING STATUS 1.

UNIT NAME Calvert Cliffs Unit 1 2.

REPORTING PERIOD OCTOBER 1993 3.

LICENSED THERMAL POWER (MWT) 2700 4.

NAMEPLATE RATING (GROSS MWe) 918 5.

DESIGN ELECTRICAL RATING (NET MWe) 845 6.

MAXIMUM DEPENDABLE CAP'Y (GROSS MWe) 866 7.

MAXIMUM DEPENDABLE CAP'Y (NET MWe) 830 8.

CHANGE IN CAPACITY RATINGS NONE 9.

POWER LEVEL TO WHICH RESTRICTED N/A

10. REASONS FOR RESTRICTIONS N/A Cumulative
  • This monthYear-to-Date to Date

{

11. HOURS IN REPORTING PERIOD 745 7,296 162,037
12. NUMBER OF HOURS REACTOR WAS CRITICAL 745.0 7,155.0 115,505.0
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 3,019.4
14. HOURS GENERATOR ON LINE 745.0 7,135.5 113,114.4
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 2,004,134 19,134,378 286,413,229
17. GROSS ELECTRICAL ENERGY GFN'TED'MWH) 661,477 6,345,988 95,173,522
18. NET ELECTRICAL ENERGY GENERATED (MWH) 634,970 6,087,225 90,556,611
19. UNIT SERVICE FACTOR 100.0 97.8 E9.8
20. UNIT AVAILABILITY FACTOR 100.0 97.8 69.8
21. UNIT CAPACITY FACTOR (01ING MDC NET) 102.7 100.8 67.7
22. UNIT CAPACITY FACTOR (USING DER NET) 100.9 98.7 66.1
23. UNIT FORCED OUTAGE RATE 0.0 2.2 8.8
24. SHUTDOWNS SCHEDULED OVER THE NEXT SIX MONTHS (TYPE, DATE AND DURATION):

Refueling, February 4, 1994, 90 days

  • Time change
25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START-UP:

N/A

Um VM UNIT SIIUTDOWNS AND l'OWER llEDUCTIONS DOCKET NO.

50-317 UNIT NAME Calvert Cliffs-U1 DATE November 12.1W3' COMPLETED BY Frank Pia 77a TELEPilONE (410) 2N1-3321 REPORT MONTil Octolnr 1993 l

METIIOD OF l

SIIUTMNG 1.ICliNStili CAUSl! & CORRECDVI!

l DURATION DOWN livliNT SYSTEM COMFONENT ACDON TO l

NO.

DATI!

TYPlil (IlOURS)

REASON 2 RIMCTOR3 REPORT #

CODiid CODI!5 PRIiVENT RECURRiiNCli l

l l

There were no signific ant power reductions l

this month.

1 F: Forced 2 Reason:

3 Method:

4 IEEE Standard 805-1984 S: Scheduled A - Equipment Failure 1 - Manual B - Maintenance or Tes!

2 - Manual Scram.

C - Refueling 3 - Automatic Scram.

5 IEEE Standard 803A-1983 D - Regulatory Restriction 4 - Continued E - Operator Training & License Examination 5 - Reduced Load F-Administrative 9 - Other G - Operational Error 11 - Other

AVERAGE DAILY UNIT POWER LEVEL oco*********************************************************************

Docket No. 50-317 Calvert Cliffs Unit No. 1 November 12, 1993 Prepared by Frank Piazza Telephone: (410) 260-3821 OCTOBER 1993 Average Daily Power Level Average Daily Power Level Day (MWe-Net)

Day (MWe-Net) 1 855 17 855 2

853 18 855 3

853 19 856 4

854 20 855 5

853 21 855 6

854 22 855 7

854 23 791 8

852 24 829 9

850 25 857 10 854 26 860 11 854 27 860 12 853 28 860 13 853 29 860 14 854 30 860 15 855 31 896 16 855

DOCKET NO. 50-317 CALVERT CLIFFS - UNIT 1 November 12,1993

SUMMARY

OF OPERATING EXPERIENCE October 1993 The unit began the month at 100rc power. On 10/8S3, at 2330, generator output power was reduced from 850 MWe to 830 MWe as a result of taking 15 circulating water pump off line for bearing repairs. The unit was returned to full generator output power on 10SS3 at 0204. The reactor power remained at 100Tc during this repair since the loss of generator output power was due to an efficiency decrease with 15 circulating water pump offline.

The unit remained at 100% power and full generator output until 10/23S3 at 0200 when power reduction began to allow for condenser water box cleaning, Amertap repairs,16 Feedwater Heater relief valve modifications and oilleak repair on 12 condensate pump. The unit power decreased to 95?c reactor power during the maintenance and was returned to 100% on 10/24S3 at 2120.

The unit completed the month at 860 MWe and 100% power.

6

s..

November 4, 1993 NFM'93-456 Page 2 of 3 REFUELING INFORMATION RE00EST 1.

Name of facility: Calvert Cliffs Nuclear Power Plant, Unit No.1.

2.

Scheduled date for next refueling shutdown:

February 4, 1994.

3.

Scheduled date for restart following refueling: May 9, 1994.

4.

Will refueling or resumption of operation thereafter require a Technical Specification change or other license amendment?

Operation after refueling will require either " Core Operating Limits Report" or will require a change to Technical Specification 3/4.2.2,

" Linear Heat Rate".

5.

Scheduled date(s) for submitting proposed licensing action and supporting information.

Submitted Septembc. 1993 for Core Operating Limits Report.

6.

Important licensing considerations associated with the refueling.

Mone identified at this time.

7.

The number of fuel assemblies (a) in the core and (b) in the spent fuel storage pool.

(a) 217.

(b) 1498.

Spent fuel pools are common to Units 1 and 2.

8.

(a) The present licensed spent fuel pool storage capacity, and (b) the size of any increase in licensed storage capacity that has been requested or is planned, in number of fuel assemblies.

(a) 4710. (NOTE 1)

(b)

O.

9.

The projected date of the last refueling that can be discharged to the Spent Fuel Pool assuming the present licensed capacity and maintaining space for one full core off-load.

March 2014 NOTE 1: 4710 total licensed site storage capacity.

(1830 pool + 2880 ISFSI) l

l 1

o**o************************************************************************

UNIT 2 OPERATING DATA REPORT ocoo************************************************************************

Docket No. 50-318 i

November 12, 1993 Prepared by Frank Piazza Telephone:(410)260-3821 OPERATING STATUS 1

1.

UNIT NAME Calvert Cliffs Unit 2 2.

REPORTING PERIOD OCTOBER 1993 3.

LICENSED THERMAL POWER (MWT) 2700 4.

NAMEPLATE RATING (GROSS MWe) 911 5.

DESIGN ELECTRICAL RATING (NET MWe) 845 6.

MAXIMUM DEPENDABLE CAP'Y (GROSS MWe) 866 7.

MAXIMUM DEPENDABLE CAP'Y (NET MWe) 830 8.

CHANGE IN CAPACITY RATINGS NONE i

9.

POWER LEVEL TO WHICH RESTRICTED N/A

10. REASONS FOR RESTRICTIONS N/A Cumulative
  • This monthYear-to-Date to Date
11. HOURS IN REPORTING PERIOD 745 7,296 145,392
12. NUMBER OF HOURS REACTOR WAS CRITICAL 745.0 4,608.4 104,572.8
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1,296.6 i
14. HOURS GENERATOR ON LINE 733.7 4,477.8 103,059.6
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 l
16. GROSS THERMAL ENERGY GENERATED (MWH) 1,939,061 11,795,515 262,940,307
17. GROSS ELECTRICAL ENERGY GEN'TED(MWH) 648,093 3,877,417 86,836,195 i
18. NET ELECTRICAL ENERGY GENERATED (MWH) 621,756 3,706,308 82,974,737 i

l

19. UNIT SERVICE FACTOR 98.5 61.4 70.9
20. UNIT AVAILABILITY FACTOR 98.5 61.4 70.9
21. UNIT CAPACITY FACTOR (USING MDC NET) 100.6 61.4 69.2 1
22. UNIT CAPACITY FACTOR (USING DER NET) 98.8 60.1 67.5 l
23. UNIT FORCED OUTAGE RATE 1.5 1.3 5.8
24. SHUTDOWNS SCHEDULID OVER THE NEXT SIX MONTHS (TYPE, DATE AND DURATION):

N/A

  • Time change
25. IF UNIT IS SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START-UP:

N/A i

UNIT SIIUTDOWNS AND l'OWER REDUCI' IONS DOCKLT NO.

50-318 UNIT NAME Cakert CliflLU2 DATE November 12.19'8 COMPLETED BY Frank Piana TELEPilONE (410) 260 u21 ItEPORT MONTil October 1993 MiiTilOD OF SillTITING LICliNSlit!

CAUSI! & CORREC11VI!

D1IRNi1ON DOWN EVI!NT SYSTliM COMPONiiNT ACllON TO N O.

D Nili TYPlil (IIOURS)

RiiASON2 RiiACIOR3 REPORT #

CODii'8 CODii5 PRiiVENT RECURRiiNCI!

93-06 931010 F

11.3 B

N/A N/A TA ECBD Unit power was reduced to 10% and the Unit was removed from the Grid for repairs to Governor Valve 4 (GV-4). After a power reduction for condenser water box cleaning and turbine vaive testing and during power escalation, GV-4 started oscillating. The failure was due to a failure of an electrical control card which controls GV-4. The GV-4 electrical control card was replaced while the generator was otT the grid. The Unit was returned to full power at 1800 on 10/11/93.

I I F: Forced 2 Reason:

3 Method:

4 IEEE Standard 805-1984 S: Scheduled A - Equipment Failure 1 - Manual B - Maintenance or Test 2 - Manual Scram.

C - Refueling 3 - Automatic Scram.

5 IEEE Standard 803A-1983 D - Regulatory Restriction 4 - Continued E - Operator Training & License Examination 5 - Reduced Load F-Administrative 9 - Other G - Operational Error 11 - Other

AVERAGE DAILY UNIT POWER LEVEL ocoo********************************************************************

Docket No. 50-318 Calvert Cliffs Unit No. 2 November 12, 1993 Prepared by Frank Piazza Telephone: (410) 260-3821 OCTOBER 1993 Average Daily Power Level Average Daily Power Level Day (MWe-Net)

Day (MWe-Net) 1 860 17 864 2

859 18 864 3

861 19 864 4

861 20 865 5

861 21 864 6

862 22 864 7

861 23 864 8

861 24 865 9

735 25 865 10 116 26 865 11 842 27 865 12 862 28 866 13 864 29 866 14 863 30 867 15 865 31 904 16 864 l

l l

l l

l

e at l

~

DOCKET NO. 50-318 CALVERT CLIFFS - UNIT 2 November 12,1993

SUMMARY

OF OPERATING EXPERIENCE October 1993 The unit began the month at 100Fc power and 860 MWe.

Power was reduced on 10SS3 commencing at 0202 for main turbine valve testing and water box cleaning. The reactor power was reduced '.o 84% at 0710 on 109B3 for this testing and cleaning. At 1210 power was increased to restore full power when electrical output power oscillations caused operators to reduce power at 1250. The o.cillations were caused by problems with Governor Valve

  1. 4. At 2210 the unit power was decreased for GV-4 repairs and the unit was taken off the grid at 0309 on 10/10/93. During repairs, the reactor power remained at 10rc. The unit was again paralleled to the grid at 1428 on 10/1093. At 1800 on 10/11S3 the unit was restored to 100c/c power.

The unit remained at 1007c power and 865 MWe for the remainder of the month.

i l

l l

1 l

6 l

- November 4, 1993 NFM 93-4S6 i

Page 3 of 3 i

REFUELING INFORMATION REQUEST l

1.

Name of facility: Calvert Cliffs Nuclear Power Plant, Unit No. 2 2.

Scheduled date for next refueling shutdown:

March 3, 1995.

3.

Scheduled date for restart following refueling: May 17, 1995.

4.

Will refueling or resumption of operation thereafter require a Technical Specification change or other license amendment?

Unknown.

5.

Scheduled date(s) for submitting proposed licensing action and supporting information.

Unknown.

6.

Important licensing considerations associated with the refueling.

None identified at this time.

7.

The number of fuel assemblies (a) in the core and (b) in the spent fuel storage pool.

(a) 217.

(b) 1498.

i Spent fuel pools are common to Units 1 and 2.

8.

(a) The present licensed spent fuel pool storage capacity, and (b) the size of any increase in licensed storage capacity that has been requested or is planned, in number of fuel assemblies.

(a) 4710 (NOTE 1)

(b) 0.

9.

The projected date of the last refueling that can be discharged to the Spent Fuel Pool assuming the present licensed capacity and maintaining space for one full core off-load.

March 2016.

NOTE 1: 4710 total licensed site storage capacity.

(1830 pool + 2880 ISFSI)