J January 20, 1994-

- j Document Control Desk U.S.

NUCLEAR REGULATORY COMMISSION Mail Station P1-137 Washington, DC 20555 Gentlemen:

DOCKET 50-301 STEAM GENERATOR INSPECTION RESULTS POINT BEACH NUCLEAR PLANT. UNIT 2 Below are the steam generator inspection results for Point Beach Nuclear Plant, Unit 2.

The inspections.were performed October 7-13, 1993, during.the Unit 2 fall 1993 refueling outage.

1 This information is. submitted in accordance with Technical Specification 15.4.2.A.7(a), "After each in-service examination, j

the number of. tubes plugged or repaired in each steam 1 generator.

1 shall be reported to the Commission as'soon as practicable."

'I In the "A" steam generator, full-length eddy current testing was performed on 1717 tubes. 'Of the 1717. tubes tested,'46 tubes'(2.7%)

.i were degraded and 1 tube' (0.06%) was defective.

A'totaloof 21-I tubes were' subsequently plugged in accordance with the' technical d

specification plugging limit of 40% through-wall defect or as a.

]

result of industry recognized pluggable indications.

i In the "D" steam generator, 1816 tubes were full-length tested.

Of.the 1816 tubes tested, 97 tubes (5.3%) were degraded.

No tubes H

werc defective.

A total of 12 tubes were subsequently plugged in'

~

accordance with the technical specification plugging limit of 40%

through-wall-defect or as a result of-industry recognized pluggable indications.

Please contact us if any further information is lequired.