GENuclear Energy V
c,enew rwax cner 175 Cunner keme. San Jose. CA 95 US January 17,1994 MFN No. 004-94 Docket STN 52-004 Document Control Desk U.S. Nuclear Regulatory Commission Washington DC 20555
[
4 Attention:
Richard W. Borchardt, Director Standardization Project Directorate
Subject:
NRC Requests for Additional Information (RAls) on the Simplified Boiling Water Reactor (SBWR) Design
Reference:
Transmittal of Recuests for Additional Information (RAls) for the SBWR Design, Letter from M. Millov to P. W. Marriott dated January 5,1994.
We have received your reference letter transmitting 98 RAls which requested extremely short turn-around (responses) back to NRC. In order to be responsive to your request, we are using the SBWR/ABWR Similarities document, NEDC-32231, to reference previously supplied answers on ABWR RAls. With that consideration, we expect to be able to answer 27 of the RAls as requested by January 31,1994. There are 12 questions which focus on plant reliability / availability as effected by non-safety equipment / systems; these questions will be answered when the SBWR Regulatory Treatment of Non-Safety Systems (RTNSS) analysis is completed mid-to-late this year. The remaining 59 questions wil be answered by March 31,1994.
See the attached table entitled I&C RAIs.
Sincerely,
)f
~
< (-
tt $l5Mr i
J. E. Leatherman SBWR Certification Manager MC-781, (408)925-2023 cc:
M. Malloy, Project Manager (NRC) (2 attachments)
F. W. Hasselberg, Project Manager (NRC) (1 attachment) lJd j
tuu ma
\\
PDR ADOCK 05200004 h
9401310106 940117 4
A PDR
]
MFN No. 004-94 Table I&C RAls RAI Number Resoonse Date Footnote 420.01 1/31/94 1
.02 1/31/94 1
.03 1/31/94 1
.04 3/30/94
.05 3/30/94
.06 1/31/94 1
.07 3/30/94
.08abc 3/30/94
.08de Summer '94 2
.09 1/31/94 1
.10 1/31/94 1
.11
'1/31/94 1
.12 Summer '94 1, 2
.13 Summer '94 2
.14 3/30/94
.15 3/30/94
.16 3/30/94 i
.17 1/31/94 1
.18 3/30/94
.19 3/30/94
.20 Summer '94 2
.21 3/30/94 i
.22 3/30/94
.23 Summer '94 2
.24 3/30/94
.25 3/30/94
.26 3/30/94 l
.27 3/30/94
.28 3/30/94
)
.29 3/30/94
.30 3/30/94 31 3/30/94 32 3/30/94 33 3/30/94
.34 1/31/94 1
.35 3/30/94
.36 3/30/94
.37 Summer '94 2
i'
.38 1/31/94
.39 1/31/94
.40 1/31/94
.41 3/30/94
.42 3/30/94
.43 3/30/94
.44 -
3/30/94
- 1. NEDC32231
- 2. SBWR/RTNSS nux = =
.i 4
~
MFN No. 004-94 Table I&C RAls RAI Number Response Date Footnote 420.45 3/30/94
.46 3/30/94
.47 3/30/94
.48 3/30/94
.49 3/30/94
.50 Summer '94 1, 2
.51 3/30/94
.52 3/30/94
.53 3/30/94
'l
.54 3/30/94
.55 3/30/94
.56 3/30/94 l
.57 3/30/94
.58 3/30/94
.59 3/30/94
.60 3/30/94
)
.61 3/30/94
.62 3/30/94 i
.63 3/30/94
.64 3/30/94
.65 1/31/94
.66 3/30/94
.67 1/31/94
.68 Summer '94 2
.69 3/30/94
.70 Summer '94 2
.71 3/30/94 i
.72 Summer '94 2
.73 3/30/94
.74 3/30/94
.75 Summer '94 2
.76 1/31/94
.77 1/31/94
.78 1/31/94
.79 1/31/94-
.80 1/31/94
.81 3/30/94
.82 '
1/31/94
.83 Summer '94 2
.84 3/30/94
.85 3/30/94
.86 3/30/94
.87 3/30/94
- 1. NEDC 32231
- 2. SBWR/RTNSS LTRhK 94-02 U __
MFN No. 004-94 Table I&C RAls RAI Number Response Date Footnote 420.88 3/30/94
.89 3/30/94
.90 3/30/94
.91 1/31/94 l
.92 1/31/94
.93 1/31/94
.94 1/31/94 95 3/30/94
.96 1/31/94
.97 1/31/94
.98 1/31/94 I
f i
i
- 1. NEDC32231
- 2. SBWR/RTNSS LTRBK 94-02 i