{{#Wiki_filter:_, MET
- CH EM TESTI N G LA B O R ATO R I ES. I N C..
369 W. Gregson Ave.
- Salt t_ake City, Utah 84115-3440 * (801) 487-0801 I
October 28, 1993 f i Chief Transportation Certification Branch _ j U.S. Nuclear Regulatory Commission Washington, D. C. 20555 i l Re: Quality Assurance Program.for Radioactive' Material Package h No. 71-0509
Dear Sir:
In accordance with 'i O CFR 71, we are requesting that Met-Chem's Quality Assurance Program, No. 71-0509, be renewed. Please find enclosed a copy of our program and a check in the amount of $280.00. S
- erel i
I ~ ston l R ia son S ety Officer DRJ/sh Enclosures / 1 r blb ' 9t 'b k,N(, bb-9 08n015 ty ( 9311090177 931028 E PDR ADOCK 07200509 l-C . ppg ~
M ET
- C H EA 389 West Gregson Avenue Sett Lake City, UtahTESTING LABORATORIES. OF U 84115 (8013487-0801 QUALITY ASSURANCE PROGRAM MET-CllEM TESTING LABORATORIES, OF UTAH, INC.
1 10CFR71 QA PROGRAM l l l } i i l r PREPARED BY A M4/ 4, A. - l DobGLAS g/. JOHNSTON { C rporate Radi tion Safety Officer APPROVED BY 6/1 b ~ N. %<iNE HANSEN President 1 i I DATE JANUARY 29, 1986 i l l l 1 s t i ) b d +/ p--.,..gQlqf3-{}~}10{PR71QAPROGRAM Page 1 of 4 J 9( ,} ju 1
l METeQ TESTING LASORATORIES, OF UTAH, INC. 1 388 West Gregson Avenue Sett Leke City, Utah 8411 S (801)487-0801 I i 1.0 ORGANIZATION i 1.1 The final responsibility for the Quality Assurance Pro-l gram for Part 71 requirements rests with Met-Chem Test-ing Laboratories, of Utah, Inc. 1.2 Design and fabrication shall not be conducted under this Quality Assurance Program. The Radiation Safety Officer is designated the responsible individual for the Part 71 l quality assurance requirements. i 1.3 The Radiation Safety Officer is responsible for overall administration of the program, training and certifica-l tion, document control and auditing. 1.4 The radiographers are responsible for handling, storing, shipping, inspection, test and operating status and record keeping. 2.0 QUALITY ASSURANCE PROGRAM 2.1 The management of Met-Chem Testing Laboratories, of l Utah, Inc. establishes and implements this Quality Assurance Program. Training, prior to engagement, for all quality assurance functions is required according to written procedures. Quality Assurance Program revisions will be made according to written procedures with man-agement approval. The Quality Assurance Program will ensure that all defined Quality Assurance Procedures, i engineering procedures and specific provisions of the package design approval are satisfied. The Quality Assurance Program will emphasize control of the charac-teristics of the package which are critical to safety. 2.2 The Radiation Safety Officer shall assure that all radioactive material shipping packages are designed and manufactured under a Quality Assurance Program approved by the Nuclear Regulatory Commission for all packages designed or manufactured after January 1, 1979. This requirement shall be satisfied by receiving a certifica-tion to this effect from the manufacturer. i l 4 ,d 10CFR71 QA PROGRAM Page 2 of 4 b i E- - -
m_ i M ET
- C H E M 369 West Gregson Avenue Salt Lake City Utah 84115 TESTING LABORATORIES, OF UTA (801)487-0801 i
l l l 3.0 DOCUMENT CONTROL 3.1 All documents related to a specific shipping package will be controlled through the use of written proced-ures. All document changes will be performed accord-l ] ing to written procedures approved by management. 1 3.2 The Radiation Safety Officer shall ensure that all qual-l ity assurance functions are conducted in accordance with the latest applicable changes to these documents. i 4.0 HANDLING, STORAGE AND SHIPPING l l 4.1 Writter, safety procedures concerning the handling, stor-l age and shipping of packages for certain special form ] radioactive material will be followed. Shipments will i not be made unless all tests, certifications, accept-ances and final inspections have been completed. Work instructions will be provided for handling, storage and shipping operations. 4.2 Radiography personnel shall perform the critical handl-ing, storage and shipping operations. 5.0 INSPECTION, TEST AND OPERATING STATUS l 5.1 Inspection, test and operating status of packages for l certain special form radioactive material will be in-l dicated and controlled by written procedures. Status j will be indicated by tag, label, marking or log entry. j Status of non-conforming parts or packages will be l positively maintained by written procedures. 1 J 5.2 Radiography personnel shall perform the regulatory re-j quired inspections and test in accordance with written j procedures. The Radiation Safety Officer shall ensure that these functions are performed. 6.0 QUALITY ASSURANCE RECORDS 6.1 Records of package approvals (including references and drawings), procuremants, inspections, tests, operating i 10CFR71 QA PROGRAM Page 3 of 4 i 8
l M ET
- C H E M 369 West Gregson Avenue Sett Lake City. UtahTESTING LABORATORIES, OF UTAH, INC.
84115 (8013 487-0B01 l l i i t i logs, audit results, personnel training and qualifica-j tions and records of shipments will be maintained. De-i scriptions of equipment and written procedures will also be maintained. i 6.1.1 The records will be maintained in accordance with a written procedure. 6.1.2 The records will be identified and retrievable. 6.1.3 The Radiation E. ety Officer will maintain a list of the records and their storage location. 1 7.0 Al'DITS l 1 7.1 Established schedule of audits of the Quality Assurance Program will be performed using written check lists. Results of audits wil] be maintained. Audit reports will be evaluated and deficient areas corrected. The audits ) will be dependent of the safety sirnificance of the activity being audited, but each activity will be audit-ed at least once a year. Audit reports will be main-l tained as part of the quality assurance records. Mem-bers of the audit team shall have no responsibility in the activity being audited. a ,1 l l l l ~ n i L A knM f RA'Ifi A[ON SpiY ~ FFICER' O l a I 1 4 i ) 1 I i l j 10CFR71 QA PROGPJLM Page 4 of 4 i i l .-.-m---. ., - - _ _ _ _ _ - _ _ _ _}}