ML20059D069

From kanterella
Jump to navigation Jump to search
Amend 107 to License NPF-5,revising Tech Spec 4.0.2 by Deleting That Combined Time Interval for Three Consecutive Intervals Not Exceed 3.25 Times Specified Surveillance Intervals
ML20059D069
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 08/20/1990
From: Matthews D
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20059D073 List:
References
NUDOCS 9009060077
Download: ML20059D069 (7)


Text

,,

V puau

' ' _.k

UNITED STATES --
5' te.i//-- iw l,E' r

NUCLE AR REGULATORY COMMISSION n

\\.jyl /

, ASHINGTON, D. C. 20555 W

GEORGIA POWER COMPANY OGLETHORPE POWER CORPORATION MUNICIPAL ELECTRIC AUTHORITY-0F-GEORGIA 3

CITY-OF DALTON, GEORGIA EDWIN 1. HATCH NUCLEAR PLANT UNIT 2 A'4ENDMENT TO FACILITY OPERATING LICENSE Amendment No.107 License No NPF 1.

The' Nuclear Regulatory Comission (the Comission) has found that:

The app (lication for amendment to the Edwin 1. Hatch Nuclear Plant,. Unit 2 the fac A-the Georgia Power Company, acting for itself, Oglethorpe Power Corpo-ration, Municipal Electric Authority of Georgia, and City of Dalton, Georgia (thelicensees)-datedApril 11, 1990,. complies with the standards and requirements of the Atomic' Energy Act of 1954, as e

amended (the Act), and the Comission's rules:and_ regulations set forth in 10'CFR Chapter I; B.

The facility will operate in conformity with the application, the-provisions of the Act, and the rules and regulations of the Comission; C.

There.isreasonableassurance(1)thattheactivitiesauthorizedby this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission'c regulations set forth in 10 CFR Chapter I; D,

The issuance of this license amendment will not be. inimical to the common defense and security or to the health and safety of the public; and n

E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

9009060077 900820 PDR P

ADOCK 05000366 PDC

j i

2.

Accordingly, the license;is hereby' anended by page changes to the Technic 61'-

, Specifications as indicated in the attachnent to this license anendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-S is hereby amended to read as follws:

-Technical Specifications l

i The Technical Specifications-contained in Appendices A and B, as revised'

[

through Amendnient No.107, are hereby incorporated in the license.

l The licensee shall operate the f acility. in accordance.with the Technical Specifications.

3.

This license anendnent is effective as of its date of issuance and shall be implenented within 60 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION s

?

44 David B. 1.atthews, Director i

Project Directorate II-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation 1

L

Attachment:

L

, Changes to the Technical Specifications Date of Issuance:

August 20, 1990 1

L 1

1-i i

[*

, ~

I R

-ATTACHMENT TO LICENSE AMENDMEl4T NO. 107 1

FACILITY OPERATING LICENSE ~NO.:NPF-5 DOCKET NO. 50-366 a

-t Replace the fol. lowing pages ot the Appendix A Technical Specifications with.

the enclosed pages. The revised pages ere identified-by amendrent number and.

centain vertical lines indicating the areas of change. Overleaf page-provided to maintain document completeness.

Remove Pages Insert-Peges 3/4.0 3/4 0-1.

3/4 0 3/4 0 !

B 3/4.0-1 B 3/4 0-1

.C B'3/4 0-2 8 3/4 0-2 d

f

.i t

i 1

r 5

4 I

l-I

1,,

I 3/k LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTSJ 3/4.0 ' APPLICABILITY LIMITING CONDITION FOR OPERATION.

I 3.0.1 Limiting Conditions for Operation and ACTION requirements shall be applicable during the OPERATIONAL CONDITIONS or other states specified for each specification..

3.0.2 Adherence to the requirements of the Limiting Condition for Operation and associated ACTION within the specified time interval shall constitute compliance =with the specification.

In the event the Limiting Condition for Operation is restored prior to expiration of'the specified time interval, completion of the ACTION statement is not required.

-3.0.3 In the event a Limiting Condition for Operation and/or associated ACTION requirements cannot be satisfied because of circumstances in excess of those addressed in the specification, the facility shall be plaed in at least HOT SHUTDOWN within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> unless corrective measures are completed that permit operation under the permissible ACTION statements for the specified time interval as measured from initial discovery er until the reactor is placed in an OPERATIONAL CONDITION i

in which the specification is not applicable.

Exceptions to these requirements shall be stated in the individual specifications.

3.0.4 Entry into an OPERATIONAL CONDITION or other specified applicability state shall not be made unless the conditions of the Limiting Condition for Operation are met without reliance on provisions contained in the ACTION statements unless otherwise excepted.

This provision shall not prevent passage thru OPERATIONAL CONDITIONS required to comply with ACTION requirements.

t 3.0.5 When a system, subsystem, train, component, or device is determined to-

~

be inoperabic solely because its emergency power source is inoperable, or solely because its-normal power source is inoperable, it may be considered 0PERABLE for the purpose of satisfying the requirements of its applicable Limiting Condition for Operation, provided:

(1) its corresponding normal or emergency power source is OPERABLE; AND (2) all of its redundant system (s),

subsystem (s), train (s), component (s), and device (s) are OPERABLE, or likewise satisfy the requirements of this specification ~

Unless both conditions (1) and (2) are satisfied, the unit shall be placed in at least HOT SHUTDOWN within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in at least COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

This specification is not applicable in Conditions 4 or 5.

SURVEILLANCE REQUIREMENTS 4.0.1 Surveillance Requirements shall be applicable during the OPERATIONAL

= CONDITIONS, or other states specified for individual Limiting Conditions for Operation, unless otherwise stated in the individual Surveillance Requirements.

4.0.2 Each Surveillance Requirement shall be performed within the specified surveillance interval with a maximum allowable extension not to exceed 25 percent of the surveillance interval.

HATCH - UNIT 2 3/4 0-1 Amendaent No. 107

t i, _

APPLICABILITY:

SURVEILLANCE REQUIREMENTS (Continued) 4.0.3 Performance-of a Surveillance Requirement within the specified time interval shall constitute. compliance with OPERABILITY requirements for a Limiting Condition for Operation and associated ACTION statements unless otherwise required by the specification.

Surveillance require-ments do not have to be performed on inoperable equipment.

4.0.4 Entry into an OPERATIONAL CONDITION or other specified applicable c

state shall not be made unless the Surveillance Requirement (s) associated with the Limiting Condition for Operation have been performed within the applicable surveillance interval or as otherwise specified, t

-4.0.5 Surveillance Requirements for inservice inspection and testing of ASME Code Class 1, 2, and 3 components shall be applicable as follows:

a.

During the time period:

1.

From issuance of the Facility Operating License to the start of facility commercial operation, inservice testing of ASME. Code. Class 1, 2, and 3 pumps and valves shall be performed in accordance with Section.XI of the ASME Boiler and Pressure Vessel Code 1974 Edition, and Addenda 1

through summer 1975, except where specific written relief has been granted by the Commission.

2.

Following start of facility commercial operation, inservice inspection of ASME Code, Class 1, 2, and 3 components and inservice testing of.ASME Code Class 1, 2, and 3 pumps and valves shall be performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda as required by 10 CFR 50, Section 50.55a(g), except where specific written _ relief has been granted by the Commission pursuant to 10 CFR 50, Section 50.55a(g) (6) (1).

b.

Surveillance intervals specified in Section XI of the ASME

. Boiler and Pressure Vessel Code and applicable Addenda for the inservice inspection and testing activities required by the ASME Boiler and Pressure Vessel Code and applicable Addenda shall be applicable as follows in these Technical Specifications:

HATCH - UNIT 2 3/4 0-2 Amendment No.107 4

~

m

.v 3/4.0' APPLICABILITY BASES The specifications of this section provide the general reouirements applicable to each of the Limiting Conditions for Operation and Surveillance L

Requirements within Section 3/4 l -

i

3. 0,,1 This specification states the applicability of each soecification in terms of defined OPERATIONAL CONDITION ~ and is provided to delineate specifically when each specification is applicable.

3.0.2 This soecification' defines those conditions necessary to constitute l

compliance with the terms of an individual Limiting Condition for Ooeration and associated ACTION reovirement.

3.0.3 This specification delineates the ACTION to be taken for circumstances not directly provided for in the ACTION statements and whose occurrence would violate the intent of the specification.

For example, Specification 3.5.1 calls for the FPCI to De OPERABLE and specifies explicit' i

reoJirements if it become inoperable.

Under the terms of Specification 3.0.3 -

if the reovired additional systems are not OPERABLE, the facility is' to be placed in HOT SHJTOOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and be 1.n COLD SHUT 00WN witnin the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

The unit shall be brought to HOT SHL ' WN and COLD SHUTDOWN within the required times by promptly initiating and carrying out an oroerly shutdown.

It is intended that this guioance also acoly whenever an ACTION statement reauires a unit to be in (at least) STARTUP within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or in (at least) M0T SHUTDOWN within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

3.0.4 This specification' provides that entry into an OPERABLE CONDITION-must ce made with- (a) the full: complement of required systems, eculpment or compenents OPERABLE and (c) all other parameters as soecifito in the Limiting Concitions= for Operation being met without regard for allowable deviations ano out of -service provisions contained in the ACTION statements.

The intent of this provision is to insure that facility operation is not initiated with either reovired equipment or systems inocersole or other limits seing exceeded.

Exceptions to this provision have been provided for a limited. number of I

soecifications when startup with inoperable eculpment woulc not affect plant safety.

These exceotions are stated in the ACTION statements of t".e

,acorcoriate soecificatiens.

3.0.5 When a system, subsystem, train, comoonent, or cevice loses either its normal electrical supply or its emergency electrical supply, the eouipment is still capable of performing its intended function in the recuired manner.

Tne safety analyses are performed assuming the loss of function of a critical piece of eculpment; thus, with a source of electrical power unavailable, a single failure is still required to reach the conditions analyzed in the FSAR.

It is recognized, however, that operation with one source of electrical power unavailable means the system, subsystem, '. rain, component, or oevice is in a degraded mode.

The ACTION statement for the loss of an electrical source is designed to allow operation to continue for a reasonable time while repairs are affected and the lost electrical source returned to service.

Therefore, there is no need for all coulement supplied by the electrical source to be olaced in ACTION statements.

HATCH - UNIT 2 B 3/4 0-1 Amendment No. 5, 49

(

y l

APPLICABILITY BASES-4.0.1 This specification provides that surveillance activities necewary to insure the Limiting Conditions for Operation are met and will be performed during the OPERATIONAL CONDITIONS for which the Limiting i

Conditions for Operation are applicable.

Provisions for additional surveil-lance activities to be performed without regard to the applicable OPERA-TIONAL CONDITIONS-are provided in the individual Surveillance Requirements.

s 4.0.2 This specification establishes the limit for which the specified time interval for Surveillance Requirements may be extended. -It permits an allowable extension of the normal surveillance interval to facilitate surveillance scheduling and consideration of plant operating conditions =that.

may not be suitable for conducting the surveillance; e.g., transient conditions or other ongoing surveillance or maintenance activities.

It also provides flexibility to' accommodate the langth of a fuel cycle for surveillances that are performed at each refueling outage and are specified with an 18-month surveillance interval-.

It is not intended that this provision be used repeatedly as a convenience to extend surveillance intervals beyond that specified for surveillances that are not performed during refueling outages. The limitation of this specification is based on engineering judgment and the recognition that the most probable result of any particular surveillance being performed is the verification of conformance with the Surveillance Requirements.

This pr0 vision is sufficient to ensure l-that the reliability ensured through surveillance activities is not significantly degraded beyond that obtained from the specified surveillance interval.

4.0.3 The provisions of this specification set forth the criteria

.'for determination of compliance with the OPERABILITY requirements of the Limiting Conditions for Operation.

Under this criteria, equipment, E

systems or components are assumed to be OPERABLE if the associated surveil-I lance activities have been satisfactorily performed within the specified time-interval. Nothing in this provision is to be construed as defining-i equipment, systems or components OPERABLE, when such items are found or i

known to be inoperable although still meeting the Surveillance Requirements.

4.0.4 -This specification ensures that surveillance activities l

associated with a Limiting Condition for Operation have been performed within the specified' time interval prior to entry into an applicable L

CONDITION. The intent of this provision is to ensure that surveillance L

activities have been satisfactorily demonstrated on a current basis as L

required to meet the OPERABILITY requirements of the Limiting Condition l

.for Operation.

l HATCH - UNIT 2 B 3/4 0-2 Amendment No. 107 i