f

I

DEC 2 31993

Docket Nos. 50-348, 50-364

License Nos. NPF-2, NPF-8

Southern Nuclear Operating Company, Inc.

ATTN: Mr. D. N. Morey

Vice President

P. O. Box 1295

Birmingham, AL 35201

Gentlemen:

SUBJECT: NRC INSPECTION REPORT N0. 50-364/93-400

This refers to the inspection conducted by NRC Mobil Nondestructive Examina-

tion (NDE) Laboratory personnel on October 4-15, 1993. The inspection

included a review of activities authorized for your Farley facility. At the

conclusion of the inspection, the findings were discussed with those members

of your staff identified in the report.

Areas examined during the inspection are identified in the report. Within

,

these areas, the inspection consisted of selective examinations of procedures

i

and representative records, interviews with personnel, and observation of

activities in progress.

The inservice inspection nondestructive examination program, presently

deployed at Farley, was found to be well implemented as confirmed by indepen-

dent testing, discussions with site personnel and ISI-NDE procedure and

program review.

Relative to the discovery of the indication in the feedwater nozzle to pipe

weld (APR2-4350-22), of the feedwater line to steam generator "C," we have

reviewed our radiographic and ultrasonic results, the original archival

radiographs, the radiographs taken by Farley during this inspection and site

.

'

generated ultrasonic data.

In addition, we have applied our own special

techniques and transducers to this indication.

Based on this information, our

experiences with nuclear power stations across the nation, the location and

nature of the weld and the materials of construction; we are characterizing

this indication as a 2" long thermal fatigue crack with approximately 0.3"

throughwall dimension as determined by UT techniques. Subsequent to the

inspection exit meeting, the licensee provided to the Region 11 staff informa-

tion on the operation of the auxiliary feedwater/feedwater system operation

,

that shows the driving force for thermal fatigue crack growth to be relatively

i

low due to the normally low auxiliary feedwater flow rate. Additionally, the

fracture mechanics analysis provided at that time indicates that a crack of

the size noted above, if it were present, would not propagate to unacceptable

-

dimensions prior to the next refuel outage. However, the site NDE staff has

characterized the indications as internal root undercut. Our current opinion

030041

940xo4o225 932223 ~

Of

PDR

ADOCK 05000348

G

PDR _

gQ(

-

,

e

'

.~

DEC 2 31993

- -

Southern Nuclear Operating

2

Company, Inc.

is that the subject area of weld APR2-4350-22 should be examined by appropri-

ate NDE (UT) techniques to track the status of the indication during the next

refuel outage, and sooner if a brief outage provides time for an examination.

,

Within the scope of the inspection, violations or deviations were not identi-

fied.

In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of

this letter and its enclosure will be placed in the NRC Public Document Room.

Should you have any questions concerning this letter, please contact us.

Sincerely,

,

l

Original signed by

Jerme J. Blake for/

)

Caudie A. Julian, Chief

Engineering Branch

,

Division of Reactor Safety

Enclosure:

NRC Inspection Report

cc w/ encl:

B. L. Moore

Licensing Manager

Southern Nuclear Operating

I

Company, Inc.

P. O. Box 1295

Birmingham, AL 35201-1295

R. D. Hill, Jr.

General Manager, Farley Plant

Southern Nuclear Operating

Company, Inc.

P. O. Box 470

Ashford, AL 36312

W. R. Bayne, Supervisor

Safety Audit and Engineering Review

Farley Nuclear Plant

P. O. Box 470

Ashford, AL 36312

(cc w/ encl cont'd - See page 3)

4

i

i

. _ _ - -

.

1

r

!

..

.

23 E

i

Southern Nuclear Operating

3

Company, Inc.

i

cc w/ encl cont'd

State Health Officer

-

Alabama Department of Public Health

434 Monroe Street

Montgomery, AL 36130-1701

James H. Miller, III, Esq.

Balch and Bingham

P. O. Box 306

1710 Sixth Avenue North

-

Birmingham, AL 35201

Chairman

Houston County Commission

P. O. Box 6406

Dothan, AL 36302

bcc w/ encl:

B. Siegel, NRR

J. Strosnider NRR

J. Blake RII

F. Cantrell, RII

G. Hallstrom RII

i

Document Control Desk

,

i

NRC Resident Inspector

i

U.S. Nuclear Regulatory Commission

,

Route 2, Box 24

.

Columbia, AL 36319

.i

i

i

File Name:

S:\\DRS\\EB\\FAR93400.LTR

,

RS

RII:DRP

W

Blake

kScantrell

24W93

12/pk/93

)

]

!