x

, WallinC Addr:ss

)

.A Akham2 Power,1 iy

=

600 North 18th Sk M[

Po,t Othee Box ?641 j

Bammgham, AL t ama 3L291 j

telephone PD5 783 f 090 q

R. P. Mc Donald i

Senior Vice President j

Flmiddge Building Ala X1ma power a: :v..

r,,

Docket No.

k l

l August 23, 1985 t

Dr. J. W. Grace, Regional Administrator U. S. Nuclear Regulatory Commission f

Region.II, Suite 3100 101 Marietta Street, N. W.

i Atlanta, Georgia 30303 i

Joseph M. Parley Nuclear Plant <- Unit 1 i

Interval 1 Period 3 Outage.1 4asarvtas4Laspeetten Beges27 2 Gentlemen

(

The Joseph M. Farley Nuclear Plant Unit-1 Interval 1 Period 3 Outage 1 Inservice inspection Report is herewith submitted for yNr review. This report' describes and summarizes the inservice-inspection activities J

performed during the Unit 1 sixth refueling outage. These activities were i

completed on May 25, 1985.

I Information contained in this report is being submitted pursuant to Article IWA-6220 of Section XI of the 1974 Edition through the-Summer 1975' i

Addenda of the ASME Boiler and Pressure Vessel Code. Other pertinent report information, as required by IWA-6210, including, as applicable, examination plans and schedules, examination results and reports, i

examination methods and procedures, evaluation of results, and corrective actions and repairs, is available at Farley Nuclear Plant for r review.

t Yours truly, j

(.

t f ' '(.

//

N R. P. Mcdonald RPM / STB drs/D-361 Enclosure cc Mr. L. B. Long t

Mr. S. A. Varga t

9008230142hhhhh Mr.-E. A. Reeves

((DR ADOCK Mr. W. H. Bradford 4g PDC i

85 - u/

h6

//r i