Reissued NPDES Permit IL0036919,issued to Clinton Nuclear Power Station
ML20059A212
Person / Time
Site: Clinton Constellation icon.png
Issue date: 07/25/1990
From: Mcswiggin T
ILLINOIS, STATE OF
To:
Shared Package
ML20059A208 List:
References
IL0036919, IL36919, NUDOCS 9008220165
Download: ML20059A212 (6)


Text

.. _ ~

l NP0t$ Permit No. It0036919 111tnots Environmental Protection Agency i

Division of Water Po11ution Control 2200 Churchill Road l

P.O. 50s 19276 Springfield. 111tnois 62794-9276 i

NATIONAL P0ttWTMT 0!$ CHARGE ELIMINATION SYSTEM

[

Reissued (NP0t$) Permit Empiration Date April 1, 1998 Issue Date: July 25, 1990 (ffective Date! August 24, 1990 i

Name and Address of Permitteet Facility Name and Address!

Illinois Power Company Clinton Nuclear Power Station 500 South 27th St.

R.R. 3. Post Office Box 228 Decatur. 111tnots 62825 Clinton. Illinots 61727 DeWitt County I

Discharge Number and Namet Receiving Waters Nt, 002 Discharge flume Clinton take No. 002(a) Sewage treatment plant effluent No. 002(b) Rad waste treatment system effluent No. 003 Water treatment wastes No. 004 Transformer area Oil-water separator.

No. 00$ Diesel generator area 011-water separator No. 006 Screen house intake screen backwash and sump discharges No. 007 Safe shutdown service water system In compliance with the provisions of the Illinois Environmental Protection Act. Subtitle C Rules and Aegulations of the Illinois Pollution Control Soard, and the FWPCA. the above named permittee is hereby authorized to discharge at the above location to the above-named receiving waters in accordance with the standard conditions and attachments herein.

I Permittee is not authorized to discharge after the above expiration date. In order to receive authorization to discharge beyond the expiration date, the permittee shall submit the proper application as required by the Illinois Eny,ironmental Protection gency (IEPA) not later than ISO days prior to the exp' ration date.

g oma Mc$wiggin. P t.

Manager. Permit section Otvision of Water Pollution Control t

TGM:GC:ct/2440.sp 1

I

.)

9008220165 900810 1

PDR ADOCK 05000461 P

PDC i

i..,,,..,

.n..

~

w a

-- -~ - - - - - - -

i f

1 1

Page 2 l

NP0t$ Perett No. It0036919 f

Effluent Lteitations and Monitoring I

LOAD LIMITS CONCENTRATION 1ht/ day LIMIf1 ma/1 l

30 DAY DAILY 30 OAY DAILY SAMPLE SAMPLC PARAMETER AVG.

MAX.

AVG.

max.

FRt0VENCY TYPt

1. From the effective date of this permit untti Aprt) 1. 1996, the effluent of the following discharge (s) thall be monitored and limited at all times as follows:

1 Outfalt(s): No. 002 Discharge Flume This discharge consists of:

Approximate Flow i

1. Main condenser cooling water 846 MGD
2. Station service water
  • 62.6 MGD t
3. Sewage treatment plant effluent 0.04 MCD
4. Radweste treatment system effluent Intermittent Flow (MGO)

Continuous pH See Special Condition No. 1

'1/ week Grab l

l Total Residual Chlorine 0.2 1/ week Tenperature See Special Condition No. 4 Continuous *"

Outfall(s): No. 002(a) Sewage Treatment Plant Effluent This discharge consists of:

Approximate flow 1.

Extended aeration sewage treatment plant effluent (OMF 0.0427 MG0) 2.

Contact stabiliaation sewage treatment plant effluent (DMF 0.0$ MGO) 3.

C&! process simulator war.tewater Intermittent Flow (MGO) 1/ week 24hr. total pH See Special Condition No. I 1/ week Grab 000s 23.2 46.4 30 60 1/ week 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> composite Total Suspended I

solids 23.2 46.4 30 60 1/ week 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> l

composite Station service water discharge consisting of various pump and bearing cooling waters, various l

heat exchangers, chillers. the HVAC system and fire protection system maintefiance flushwaters.

See Special ?ondition No. 3 and No. 6.

"* See special Condition No. 4(a)

B

. - - =...

i Pa,gt 3 NP0ts Permit No. IL003601g Effluent Limitations and Monitoring LOAD LIMITS CONCINTRATION.

i 1ht/aar LIMitt as/1 30 DAY DAILY 30 DAY DAILY

$ AMPLE SAMPLE PARAMEftp AVG.

MAX.

AVC.

MAX.

FRt00ENCY TYPt l

2. From the effective date of this permit until April 1. 1996, the effluent of the following discharge (s) shall be monitored and limited at all times as follows:

Outfall(s): No. 002(b) Redwaste treatment system effluent Approximate Flow intermittent Thia discharge consists of:

1. Equipment drain subsystem
2. Floor drain subsystem
3. Laundry waste subsystem l
4. Chemical waste subsystem 1

Flow Continuous Total Suspended solids 18 30 1/ week 8 Hour composite

}

011 and Grease 15 20 1/ week Grab a

Outfall(s):

No. 003 Water treatment wastes this discharge consists of:

Maximum Flow

1. F10ccu14 tot blowdown-(0.216 MGO)
2. Pressure filter backwash
3. Carbon coluem backwash
4. pH adjusted dominera11rer regenerant waste
5. Auxiliary boiler blowdown
6. Standby liquid control pap surveillance operation wastewater F10W 1/ week 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Total pH See $pecial Condition No. 1 1/ week Grab Total Suspended Solids 15 30 1/ week 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> composite l

t

1 1

Page a NP0t$ Permit No. IL0036313 Ef fluent Limitations and Monitoring l

LDAD LIMITS CONCENTRATION 1 bt / da y LIMITS ma/1 30 DAY CAILY 30 DAY DAILY SAMPLE SAMPLE i

PARAMETER AVG.

MAX.

AVG.

MAX.

FREQUENCY TYPE

3. From the effective date of this permit until April 1. 1995, the effluent of the following discharge (s) shall be penitored and limited at all times as follows:

Outfa11(s):

No. 004 Transformer area Approximate Flow: intermittent 011-water separator This discharge consists of:

1. Machine shop area floor drains
2. Paint storage room floor crains
3. 011 tank area and turbine oil transfer pump area drains
4. Transformer ares drains Flow 1/ week Estimate 011 and Grease 15.0 20.0 1/ week Grab outfall(s):

No. 00$ Diesel generator area Approximate Flow intermittent Oil-water separator This discharge consists of:

1. Diesel generator building floor drains
1. Diesel fuel storage area drains
3. Fuel unloading area drains e

Flow 1/ week Estimate 011 and Grease 15.0 20.0 1/ week Grab 09tfall(s):

No. 006 $creen house intake screen backwash and screenhouse sump dis-"trges.

See Special Condition No. 8 Approximate Flow (0.0$$ MGO)

Outfall(s)!

No. 007 $afe shutdown service water system Approximate Flow (47.5 MGO)

This discharge consists of

1. toutpment cooling water
2. Diesel generator cooling water l
3. Residual heat removal heat exchangers i

Flow Continuous f

i

.n-,

., ~,,

Page 5 NPDES Permit No. IL0036919 tancial fonditient SPECIAL C0#0!T!0N 1.

The pH shall be in the range of 6.0 to 9.0.

SPECI AL C0#0!T104 2.

Samples taken in compliance with the effluent monitoring requirements shall be taken at a point representative of the discharge, but prior to entry into the receiving waters.

SPECIAL CON 0!T!DN 3.

Continuous monitoring throughout a representative chlorination period shall J

be performed once per week above the second drop structure in the discharge flume during the i

respective chlorination period allowing for lag time between the initiation of chlorination and the point of sampling. If continuous monitoring cannot be performed grab samples shall be taken i

in the discharge flume at five minute intervals or less during the respective chlorinetton period to develop a chlorine concentration curve allowing for lag time between the initiation of ehlorination and the point of sampling before the first grab sample is taken. The individual values and average (mean) values for each set of grab samples shall be reported including the time samples were collected the time and duration of the chlorine dostng period plus the amount (1bs/ day) of chlorine applied. for continuous chlorine monitoring, analytical data from only one representative penitoring period each week need be reported on the monthly discharge monitoring j

report. For continuous monitoring, the chlorine concentration curve. the time of templing, the time and duration of the chlorine dosing period plus the amount (1bs/ day) of chlorine applied shall be reported.

SPECIAL CONDITION 4.

Discharges to Lake Clinton shall not exceed an effluent temperature of 960F except that during such Line as only one generating unit is in operation at the Clinton 8

Nuclear Power Station, the daily average discharge temperature shall not exceed 99 F during more than 12 percent of the hours in twelve-month periods ending with any month and shall at no time exceed 108.30F.

(a) Cone 11ance with the water temperature monitoring requirunents shall be determined by

)

reporting the datly average and daily maximum water temperature of the discharge. The 0

number of hours the discharge temperature exceeds 99.0 F during each month shall also be reported.

l (b) During the ef fective perted of PCB Order 89-213 the temperature at the second drop structure of the discharge flume shall be limited to a daily average temperature not l

exceeding 99* F during more than 90 days per year running from January 1st through December 31 and at r.o time shall the temperature of the discharge exceed 110.7* F.

SPECIAL CON 0!T!DN 5.

The ntake structure shall be operated and maintained in a professional manner so as to minimize the possible adverse impact on water quality which might result from the discharge of any collected debris or fish. So as to ministre pc

'e adverse impacts for purposes of this permit, the intake structure operation and natntt

.all include, but not be limited to the f ollowing:

a.

Outer bar racks shall be routinely cleaned and collected debris properly disposed.

SPECIAL CON 0! TION 6.

Chlorine may not be discharged from each unit's main cooling condensers for more than two hours in any one day.

l

$PECIAL CONDITION 7.

There shall be no discharge of polychlorinated biphenyl compounds (PCBs).

l SPECIAL CON 0! TION 8.

The permittee shall continue to conduct the Operational Environmental l

Monitoring Program on Clinton Lake (Operational Environmental Monitoring Program approved by ! EPA on July 1.1986) until 'he Illinois Pollution Control Board rules on Illinois Power Company's

-l upcoming site specific thermal standard request pursuant to 35111. Adm. Code 302. 211 ( f ). The l

environmental monitoring program report for the 1989-1990 period does not have to be submitted to IEPA in 1991 but must be submitted to IEPA during 1992 covering the period 1989 through 1991.

SPECIAL CON 0! TION 9.

Illinois Power Company's thermal demonstration pursuant to 35111. Adm. Code 302.211(f) is scheduled for 1992.

  • Final action on any adjusted thermal standards will be taken at that ttse and incorporated into this permit.

SPECIAL CON 0! TION 10.

Illinois Power Company's demonstration for the Clinton Nuclear Power Station regarding water intake structure operations in accordance with Section 316(b) of the Clean Water Act is pending before this Agency. Final action on this matter 13 scheduled for 1992.

j

l Page 6 NPDES Permit No. IL0036919 insetal conattions SPECIAL CDNDIT!DN 11.

The permittee sna11 record monitoring results on Discharge Monitoring Report forms using one such form for each discharge each month.

The completed Discharge Monitoring Report forms shall be meiled and received by the IEPA no l

later than the 1$th day of the following month, unless otherwise specified by the permitting authority. Discharge Monitoring Reports shall be melled to the ItPA at the following address:

Illinois Enytrommental Protection Agency Otvision of Water Pollution Control 2200 Churchill Road Springfield. Illinois 62706 Attention: Compliance Assurance Section

}

l P

4

-