ML20058Q004

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-327/93-46 & 50-328/93-46 on 930913-17.No Violations or Deviations Noted
ML20058Q004
Person / Time
Site: Sequoyah  
Issue date: 10/15/1993
From: Cline W
NRC Office of Inspection & Enforcement (IE Region II)
To: Medford M
Tennessee Valley Authority
Shared Package
ML20058Q007 List:
References
NUDOCS 9310260037
Download: ML20058Q004 (3)


See also: IR 05000327/1993046

Text

x.

m

h

,

00T 15.1933

. Docket Nos. 50-327, 50-328

License Nos'. OPR-77, DPR-79-

Tennessee . Valley Authority

,

' ATTN: Dr. Mark 0. Medford

Vice President, Technical

>

Support

38-Lookout Place

1101. Market Street

,

Chattanooga, TN 37402-2801

Gentlemen:

r.

SUBJECT: NRC INSPECTION REPORT NOS. 50-327/93-46 AND 50-328/93-46

'

i

This refers to the inspection conducted by D. W. Jones of this office on

-

September 13-17, 1993. The inspection included a review of activities

'

authorized for your Sequoyah facility. At the conclusion of the inspection,

the findings were ' discussed with those members of your staff identified in the

-

,

report.'

Areas examined during the inspection are identified in the report. Within

these areas, the ' inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observation of

activities in progress.

Within.the scope of the inspection, no violations or deviations were

identified.

In accordance with 10 CFR 2.790(a),- a copy of this letter and its enclosure

will be placed in the NRC Public Document Room.

Should you have any questions concerning this letter, please contact us.

Sincerely,

0,~.lGINAL SKINED GY

MUAM E. CUNE

William E. Cline', Chief

Radiological Protection and

-Emergency Preparedness Branch

Division of Radiation Safety

-

and Safeguards

Enclosure: :(See page 2)

1

9310260037 931015 ~

l

PDR- ADOCK 05000327

i

G

PDR:

-

hU0

,

-

-

-

wm

,

+

. .

l

f

' Carolina Power and Light Company.

2

" Enclosure:-

- NRC Inspection Report

cc w/ enc 1:

W. H. Kennoy,-Director

'

~

- Tennessee Valley. Authority .

ET 12A

,

' 400 West Summit Hill Drive

Knoxville, TN 37902

'

R. M.-.Eytchison, Vice President

Nuclear Operations

Tennessee-Valley Authority.

38 Lookout Place

1101 Market Street-

r

Chattanooga, TN 37402-2801

B.'S. Schofield, Manager

-

Nuclear Licensing and

Regulatory Affairs

-Tennessee Valley Authority

. 5B Lookout Place

1101 Market Street-

Chattanooga, TN 37402-2801

Robert Fenech, Vice President

Sequoyah Nuclear Plant

- Tennessee Valley Authority

P.~0.' Box 2000

L

Soddy-Daisy, TN 37379

TVA Representative-

'

. Tennessee Valley Authority

Rockville Office

11921 Rockville Pike-

. Suite 402

Rockville, MD 20852

Ralph H. Shell'

Site Licensing Manager

- Sequoyah Nuclear Plant

P. O. Box 2000

.

- Soddy-Daisy, TN -37379

Michael H. Mobley, Director.

Division,of Radiological Health

3rd Floor, L and C ' Annex

401' Church Street

' Nashville,'TN 37243-1532

cc w/ encl ~:

(cont'd on page 3)

i

_ _ _ _ _ _ _ _ _ - -

.<

,

.

,

Tennessee Valley. Authority

3

-cc w/ encl:

(cont'd)

. General Counsel.

-

Tennessee Valley Authority

'ET 11H

~400 West Summit. Hill Drive

Knoxville, TN 37902

County Judge

Hamilton County Courthouse

Chattanooga, TN 37402

Bill'Harrisi

Route.1, Box 26

~ Ten Mile,.TN.37880

bcc w/ encl:

E. W. Merschoff, RII.

J. R. Johnson, RII

-P. J. Kellogg, RII

S. E. Sparks, RII

B. M. Bordenick,-0GC

D. E. LaBarge, NRR

G. Lainas,.NRR.

F. Hebdon,.NRR

Document Control Desk

NRC Resident Inspector

U.S. Nuclear Regulatory Commission

2600 Igou Ferry.

Soddy-Daisy, TN 37379

RII:DRSS- RII:

RSS RLI RP

hf'

%

SEparks

[fJones

TDe er

so/ry/93

./p/93

lo/1993'

,

-

m__

- _ _ - - . . _ _ _ _ _ . _ _