Text
0FDUK01D COPY
-
.
DEC. 0 21993
Docket No. 50-62
License No. R-66
University of Virginia
ATTN: Dr. R. V. Mulder, Director
Reactor Facility
Charlottesville, VA 22901
Gentlemen:
SUBJECT: NRC INSPECTION REPORT N0. 50-62/93-04
This refers to the inspection conducted by C. Bassett of this office on
November 1-4, 1993. The inspection included a review of activities authorized
for your University of Virginia Reactor. At the conclusion of the inspection,
the findings were discussed with those members of your staff identified in the
enclosed report.
Areas examined during the inspection are identified in the report. Within
these areas, the inspection consisted of selective examinations of procedures
and representative records, interviews with personnel, and observation of
activities in progress.
Within the scope of the inspection, violations or deviations were not
identified.
In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of
this letter and its enclosure will be placed in the NRC Public Document Room.
Should you have any questions concerning this letter, please contact us.
Sincerely,
DRIGINAE SIGNED EY
DOUGLAS M. COulNS
Douglas M. Collins, Chief
Nuclear Materials Safety and
Safeguards Branch
Division of Radiation Safety
and Safeguards
Enclosure:
NRC Inspection Report
cc w/ encl:
(See page 2)
9312270262 931202
ADOCK 05000062
O
230023
!
IGC6
.
,
R.021993
University of Virginia
2
!
cc w/ encl:
Dr. Paul Allaire, Chairman
Department of Mechanical, Aerospace
'
and Nuclear Engineering
University of Virginia
Charlottesville, VA 22901
Dr. William Vernetson
,
Director of Nuclear Facilities
'
Department of Nuclear Engineering
Sciences
University of Florida
202 Nuclear Sciences Center
Gainesville, FL 32611
Dr. Ratib A. Karam, Director
Neely Nuclear Research Center
Georgia Institute of Technology
900 Atlantic Drive, NW
Atlanta, GA 30332
Mr. Pedro B. Perez
Associate Director
i
Nue: ear Reactor Program
North Carolina State University
P. O. Box 7909
Raleigh, NC 27695-7909
Leslie P. Foldesi, Director
Bureau of Radiological Health
.
Division of Health Hazards Control
109 Governor Street, Room 916
,
'
Richmond, VA 23219
bec w/ encl:
A. Adams, NRR
J. Caldwell, NRR
C. Bassett, RII
Document Control Desk
1
4
g:\\drss\\rsps\\univa304. chb
!
i
RII:DRSS
R11:DRSS
.i
'T$R
T3D1
1
CHBassett
EJMcAlpine
11/ 2- /93
12/ 2 /93
'