___ . _ _ _ - . . _ . - -- - - -

-~,

s

,o 1

Alabama Power Comp;ny 40 inverness Center Parkway Post Office Box 1295 j Birmingham Alabama 35201  ;

Telephone 2o5 668-5581 W. G. Hairston, til i

Senior Vice President  !

Nuclear Operation. Alabama Power the southern ekctre system July 13, 1990 10 CFR 50.90 l

i Docket Nos. 50-348 50-364 j

U.S. Nuclear Regulatory Commission ATTN: Document Control Desk  ;

Vashington, D. C. 20555 l Gentlemen:  !

Joseph M. Farley Nuclear Plant Proposed Change to End-of-Life Moderator Temperature Coefficient Technical Specification l The use of 18-month fuel cycles at Farley Nuclear Plant Units 1 and 2 has led to higher core average temperatures and higher discharge burnup resulting in more negative end-of-life (EOL) moderator temperature ,

coefficients (MTC). Thus, it is becoming increasingly probable that reload  ;

cores vill fail to. meet the current 300 ppm surveillance criterion ,

associated with the EOL limiting condition for operation limit.- Failure to meet the surveillance criterion does not by itself imply a failure-to meet i the actual EOL MTC limit stated in limiting condition for operation but  !

, invokes the requirement that-Hot Full Power MTC continue to be measured at- l least once per 14 Effective Full Power Days during the remainder of--the  !

( fuel cycle. This. repeated surveillance is performed to demonstrate that the actual inventory conditions for operation limit on EOL MTC is not '

i i

violated. Technical Specification 3/4.1.1.3 prescribes the limiting condition for operation and surveillance requirements for the EOL MTC. The..

existing limits contain conservatism which may result in required surveillances which place undue' demand on plant operators and require plant cperation under non-steady state conditions.

Therefore, Alabama Power Company hereby proposes to amend the Farley Nuclear Plant Units 1 and 2 Technical Specification requirements for the EOL MTC. The proposed changed-pages are provided in. Attachment 1. The ,

technical justification supporting'the proposed changes is provided in- '

l Attachment 2 as.VCAP-11953 (Proprietary) and VCAP-11954 (Non-proprietary)  !

L entitled " Safety Evaluation Supporting a More Negative EOL Moderator Temperature Coefficient Technical Specification for Joseph M. Farley Nuclear Plant Units 1 and 2."- Please note that the requested changes are very similar to those previously requested by Northeast Utilities for  !

-Millstone Unit.3 (Docket No. 50-423) by two submittals dated October 5, '

1988. The NRC approved the Millstone request by letter dated December 20, 1988.

l Ab Y 9008150138 900713 f /. M i !M gDR APJCK 0500g 8 { p[ 'ggg

, g g'

r U.S. Nuclear Regulatory Commission Page 2 j I

Also enclosed with Attachment 2 is a Vestinghouse authorization letter, l CAV-89-003, Proprietary Information Notice, and accompanying affidavit. ,

VCAP-11953 contains information proprietary to Vestinghouse Electric Corporation j which is supported by an affidavit signed by Vestinghouse, the i ovner of the information. The affidavit sets forth the basis on which the j information may be withheld from public disclosure by the Commission and  ;

addresses with specificity the considerations listed in paragraph (b) (4) of Section 2.790 of the Commission's regulations. Accordingly, it is respectfully requested that the information which is proprietary to Vestinghouse be withheld j from public disclosure in accordance with 10CFR Section 2.790 of the Commission's regulations.  ;

Correspondence with respect to the proprietary aspects of the Application for  ;

Vithholding or the supporting Vestinghouse affidavit should reference CAV-89-003 i and should be addressed to R. A. Viesemann, Manager of Regulatory & Legislative Affairs, Vestinghouse Electric Corporation, P. O. Box 355, Pittsburgh, l Pennsylvania 15230-0355. l Alabama Power Company has determined that the proposed changes do not involve a >

significant hazards consideration. In accordance with 10CFR50.92 a significant hazards consideration evaluation is provided as Attachment 3. ,

Alabama Power Company requests that the NRC review and approve this proposed change by December 30, 1990. In addition, please note that four editorial changes have been made to Bases Section 3/4.1.1 to correct improper grammar and punctuation from previous revisions to these pages.

Alabama Power Company's Plant Operations Review Committee has reviewed the proposed changes and the Nuclear Operation Review Board vill review the changes at a future meeting. A copy of this proposed change is being sent to Dr. C. E. Fox, the Alabama State Designee, in accordance with 10CFR50.91(b)(1).

If there are any questions, please advise. ,

Respectfully submitted, ALABAMA POWER COMPANY dd$16s V. G. Hairston, III VGH/JARimgd 5.46 Attachments -

cc Mr. S. D. Ebneter SVORN TO AND SUBSCRIBED BEFORE ME Mr. S. T. Hoffman Mr. G. F. Maxwell THIS /3 0 DAY OF d u a , 1990 Dr. C. E. Fox g /j J llhA D f A1te[ g//JLi( Df Notary Publye-My Commission Expires: / /E 9A I I i