SACRAMENTO MUNICIPAL UTIUTY DISTRICT O 6201 S Street, P.o. Box 1583o. Secremento CA 95852 183o (916) 452 3211-AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA 1
E
-AGM/NUC 90-212-e
+
August 07,:1990 4
j-(
U. S. Nuclear Regulatory Commissien I
Attn:~ Document Control Desk 4
Hashington, DC 20555.
+
4 m
- Docket'No 50-312 J
Rancho Seco Nuclear Generating Station p
License No. DPR '
i CORRECTION TO THE LIST OF TECHNICAL SPECIFICATIONS APPLICABLE IN THE
'DEFUELED CONDITION l
References:
1.
D. Keuter (SMUD) to G. Knighton (NRC) letter AGH/NUC 89-261 h
l' dated December 4, 1989 y
2.
D. Keuter (SMUD) to J. Larkins (NRC) letter AGM/NUC 90-109 dated May 25, 1990-1 g
.i Attention:
John Larkins a
The purpose of this letter is to notify you of.a minor change.to the list of m
Technical Specifications applicable in the;defueled' condition.-
e In Reference 1, the Disnict transmitted to.the NRC'an evaluation of the O
Rancho Seco' Technical Specifications that apply to the undefined.defueled '
i mode. The? submittal summarized the evaluation with a-list of Technical l
~ Specification sections det rmined applicable when fuel was' removed from the u
reactor-vessel in conjunction with the future status of Rancho Seco.
Also, as stated in Reference 1, the District anticipated that refinements to the list of applicable' Technical Specifications would occur, and committed to provide-f the: NRC in-writing of any refinements to this list.
L N
In-Reference 2, ths District revised the list of Technical Specifications-sghj applicable in the undefined defueled mode.
The criteria used to develop the
,oca revised list was the same as. that used in Reference 1.
Originally, D88 Reference 1 included some Technical Specification requirements the District
$8 determined were'.no' longer applicable in the defueled condition. -Now, as a result of the continuing-plant closure effort, the District has determined M.
that:a correction to the list of Technical Specifications applicable in the-18 defueled condition is required. A single item included in the list provided W
in Reference 2 is determined not to be applicable in the defueled condition.
5 A' discussion of this refinement to the list is provided below.
Attachment I 88 constitutes the present list of Technical Specifications determined applicable
- fjun-y n-the defueled condition.
g i
Lf\\
- RANCHO SECo NUCLEAR GENERATING STATloN D 14440 Twin Cities Road, Herald, CA 95638 9799;(209) 333 293
-J'ohn Larkins. AGM/NUC 90-212-p
.Technica1' Specification Table 4.1-1, Item 63, High Range Noble Gas Effluent Monitors, was inadvertently included in the list of Technical Specifications determined applicable in-the defueled condition. This surveillance requirement is associated with the high range,' noble gas accident monitoring instrumentation requirements specified in Technical Specification Table
'3.5.5-1. Item 6.
The accident monitoring requirements of Table 3.5.5-1 are not applicable in the Cold Shutdown and Refueling modes. This mode applicability limitation is specified in Table 3.5.5-1.- As stated in Reference 1, the-defueled condition is_an undefined mode, but is bounded by the Cold Shutdown'and Refueling modes.,In addition,-the District determined in Reference 1.that the Table 3.5.5-1 requirements are not applicable in the-defueled condition. Therefore, because the high range, noble gas. monitors are not required to be operable in the defueled condition, the corresponding; surveillance requirements (Table 4.1-1 Item 63) are not required to be included in the list of. Technical Specifications applicable in the defueled
-condition.
Members of.your staff with questions requiring additional information or clarification may contact Jerry Delezenski at (209) 333-2935, extension 4914.
Sincerely, s_
MJ Dan R. Keuter Assistant General Manager
. Nuclear
= Attachment cc w/atch:
S. Reynolds NRC, Rockville.
J. B. Martin, NRC, Halnut Creek C. Myers, NRC, Rancho Seco
7p
>+
y LTechnical Specifications Applicable?
';;l)'
Il.
"" k John i.arkins AGM/NUC 90-212-in the.Defueled Condition ATTACHMENT I 8/1/90-p'.
- f". -Technical i'
Specification-Section_
Conditions Section Definitions (except OPERABLE' excludes emergency power source)
- 3. 0L W:
3.8.11 Monitor-R15028 only.. Applicable whenever spent fuel is stored-in the spent 1 fuel pool.
-3.8.12t 3 9.1 o
3.9.5 3.12 Applicable-only for systems required to be OPERABLE.-
3.14 3.15
,3.16 -
3.17 3.181 3.21
'3.22' 3.23 3.25-3.26 3.29
'4.0 Table 4.1-1 Item 44a
' Applicable for process radiation monitors R-15017A, R-15044 R-15045, and R-15546A only.
Item _44b Applicable for area radiation monitor R-15028 only.
-Item 45 Item 46
. Item 47 Item 51 l
11ble 4.1-2 Item 5:
Appites to the spent fuel pool fuel handling bridge only.
. Item 8 Applicable-for HEPA Filter units only.
Item-9 Item'll
' 4.14 -
Applicable only for systems required to be OPERABLE.
4.15
.4.18 4.19
4.25 4.26
'4;27' 4.29 4.30 4.34-Section 5 Design Features (except for spent fuel pool boron, Specification 5.4.2)
'Section 6 Administrative Controls (Specification 6.lf is not applicable, and the on duty shift crew requirements (Table 6.2-1) are, as a minimum,-one Shift Supervisor, who is a NRC Senior Licensed Operator, one NRC Licensed Operator (or NRC Senior Licensed Operator), and one Non-Licensed Operator.)
1