] Washington StateUniversity M Nuclear Radiation Center Pullman, WA 99164-1300 509-335-8641 FAX 509-335-4433 December 12,1993 1
l Document Control Desk i
U.S. Nuclear Regulatory Commission j
Washington, D.C. 20555 Ref: Docket 50-27 1
Dear Sir:
In accortlance with the provisions of the Code of Federal Regulations section 10 CFR 50.4 and 50.36, Washington State University TRIGA reactor facility (License No. R-76) requests to amend its Technical Specifications. The proposed changes are necessary to make our document comply:
with the new 10 CFR 20 regulations and to correct some minor errors. The document including the proposed changes has been reviewed and approved by the Facility Reactor Safeguards-Committee.
Proposed Changes:
l Page Change i
2 In Reportable Occurrence:(2) change
" limiting condition for operation" '
to " limiting condition of operation listed in Section 3.0" l
13 In section 3.8, Specification: change "4 x 10-8 ci/ml" to--
j "I x 10-8 pCi/ml" 13 In section 3.8, Basis: change "4 x 10-8 pCi/ml" to "I x 10-8 pCi/ml" 14 In section 3.9, Basis: change l
" maximum permissible concentration (MPC) values."
to " derived air concentration (DAC)." '
14 In section 3.9, Basis: change l
"the appropriate MPC value."
l to "the appropriate DAC value."
14
. In section 3.10, Soecification:(5) change.
"In calculations pursuant to item 4 above,"
to "In calculations pursuant to item 5 above,"
1 M O O C. A '
t b
DO bObOb27 h
P PDR bl
18 In section 3.14, Specification: (3) change "10 CFR 20 Appendix B, Table II, Column 2 value" to "10 CFR 20 Appendix B, Table 3 value" 19 In section 3.14, Buis: (3) change.
" Table II, Column 2 limit for 60Co is 3 x 10-3 pc/t."
to " Table 3 limit for 60Co is 3 x 10-5 Ci/mt."
also change
" worst case would be atleast 1 x 104 c/f, or 100 Pc/f, or about one-thirtieth of the 10 CFR 20 limit stated above. : Setting a limit'of ten times -
' the detection limit and one-thint the discharge limits pmvide the facility" ~
to " worst case would be at least 1 x 10-7 pCi/mt, er 100 pCi/f, or -
about one-thme-hundredth of the 10 CFR 20 limit stated above. Setting a limit of 100 times the detection limit and one-thint the discharge limits pmvides the facility" 22 In section 4.3.3,Saccifications: change
" a calibration of the A-41' system" -
to " a calibration of the Ar-41 system"~
32 In section 6.5.2, change'
" The University's Radiation Safety' Supervisor"'
to " The University's Radiation Safety Director" ~
32 In section 6.5.4, Reviews: add to the list of RSC responsibilities
"(9) annual review of the radiation protection program" '
i j
34 In section 6.8, item (7) change -.
i
" power equipment" to "powercalibration"--
J
.1
'l l
I
.)
L L
~ -
i 1
-l 37 change "Lianid Waste (summarized on a monthly hacic) t)
radioactivity discharged dudng the reponing period i
total estimated quantity of radioactivity released (in curies),
{
an estimation of the s gific activity for each detectable radier aclide present if the specific activity of the released i
material after dilution is greater than 10 CFR20 Appendix t
B limits, summary of the total release (in curies) of each'nuclide i
determined just above for the reportmg penod based on.
i representativeisotopic analysis, estimated average concenuation of the released radioactive -
material at the point of release for the reporting period in terms of pCi/cc and fraction of the applicable MPC.
i i
(ii) total volume (in gallons) of effluent water (including dilutant) released during each period of release" to
}.:
"Liauid Waste (summarized on a monthly basis)
(i) monthly radioactivity discharged 0
total estimated quantity of radioactivity released (in curies),
an estimation of the specific quantity for each detectable radionuclide in the monthly release,-
fraction of 10 CFR 20 table 3, appendix B limit for each 3
detectable radionuclide taking into account the dilution factor from the total volume of sewage released by the l
licenseeinto the sewage system, i
l sum of the fractions for each radionuclide reported above.
(ii) total quantity of radioactive material released by the facility into the sewage system during the year period of the report" - -
l l
i
~
~_
1 37 In section 6.10, Gaseous Waste, (i) change
" in terms of pCi/cc and fraction of the applicable MPC value,"
l
- to "in terms of pCi/ml and fraction of the apolicable DAC value,"
~
- i 37
. greater than 8 days released in pCi/cc durinfj the" o
to " greater than 8 days aleased in pCi/ml during the" 1
38 In section 6.10, Gaseous Waste, (i) change.
" terms of pCi/cc and fraction of the applicable MPC value for the mporting period if the estimated release is greater than 20% of the applicable MPC,"
to " terms of pCi/ml and fraction of the applicable DAC value for the reponing 4 period if the estimated release is greater than 20% of the applicable DAC,"
l I
Y If you have any questions, please contact Dr. Gerald Tripard, Facility Director.(509)'335-0172
.l l
Sincerely,
.?
s*G f
}%$
V Gerald E.Tripard M. Howard Miles
.l i
Director Chair, Reactor Safeguards Committee !
cc: Region V NRC office 4
I
..f l
1 i