g.

.g NORYHERN STATES POWER COMPANY M s N N E A PO LI S. M f N N E S OTA 58401 August 3, 1973

',,)u S

pLL'mau.

.' '\\

9]

U.S. fygg,;;g pEr AUG 6 1973,91 I

Mr. J F O' Lee. Y, Director Cor,gr337 Directorate of Licensing V

y'((u gp o

United States Atomic Energy Cocnission Washing tori, DC 20545 4

y l

Dear Mr. O' Leary:

MONTICELLO NUCLEAR GENERATING PLAh7 Docket No. 50-263 License No. DPR-22 Submittal of Summary Technical Report on Primarv Containment Integrated Leakage Rate Test Attached you will find 40 copies of the summary technical report,

" Reactor Centainment Building Integrated Leak Test - May,1973."

This report is submitted in accordance with Monticello Technical Specification 6.7.C.I.

Yours very truly, N

h-N L 0 Mayer, PE Director of Nuclear Support Services fj 4

c, g6 373 r LOM/D'Wbr G

UU cc: B H Grier G Charnoff g

/

Minnesota Pollution Control Agency

/*

d At tn.

K Dzugan Attachments f[, b 9104250472 730803 CF ADOCK 0500 63

-