ML20058K215
| ML20058K215 | |
| Person / Time | |
|---|---|
| Site: | Westinghouse |
| Issue date: | 12/03/1990 |
| From: | Dan Collins NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Koga R WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP. |
| References | |
| NUDOCS 9012170034 | |
| Download: ML20058K215 (1) | |
Text
.
(
~
DEC 0 3 W Docket No~ 70-1151 License No. SNM-1107 Westinghouse Electric Corporation ATTN: Mr. R. H. Koga, Manager Columbia Plant Commercial' Nuclear Fuel Division Drawer R i
Columbia, SC 29250 Gentlemen:
SUBJECT:
NRC INSPECTION REPORT-N0. 70-1151/90-08 Thank you for your response of November-16, 1990, to our Notice of Vialation, j
issued on October 18,1990,-concerning activities conducted at your Columbia facility.
We have evaluated your _ response and found that it meets the requirements of 10 CFR 2.201.-
We will examine the~ implementation of your corrective actions during future inspections'.
l We appreciate your cooperation in this-matter.
]
Sincerely, i
-ORIGIN At SIGNED BY' i
DOUGLAS A COLLNS-
]
Douglas M. Collins, Chief i
Radiological Protection and Emergency Preparedness Branch i
l Division of Radiation Safety l
l and Safeguards l
cc:
State of South Carolina i
bec: Document Cons rol Desk l
License Fee Management Branch i
=
i y
l I
RII SS Ril:DRSS Rll:D ;
% & /av it
)
M 1110tt JPotteF c
ine l
11g90 11/jc/90 J/90 i
9012170034 901203 ADOCK0700g1 DR g