ML20058H482

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 931103-05.Violation Noted: Licensed Reactor Operator Failed to Observe Reactor Period Meter or Period Strip Chart Recorder During Startup & Operation as Required by Procedure,Per 10CFR2,App C
ML20058H482
Person / Time
Site: University of Missouri-Rolla
Issue date: 12/06/1993
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20058H464 List:
References
50-123-93-04, 50-123-93-4, NUDOCS 9312130091
Download: ML20058H482 (1)


Text

E NOTICE OF VIOLATION

i University of Missouri-Rolla Docket No. 50-123 j

University of Missouri-Rolla License No. R-79 Nuclear Reactor j

t During an NRC inspection conducted on November 3-5, 1993, a violation of.NRC l

requirements was identified.

In accordance with the " General Statement of j

Policy and Procedure for NRC Enforcement Actions,"' 10 CFR Part 2, Appendix C,

~l the violation is listed below:

1 i

i The University of Missouri-Rolla, Technical Specifications (TS) 6.3 states j

that the reactor starf shall utilize written procedures for the startup, j

operations and shutdown of the reactor.

i SOP-103, Reactor Startup Procedure, step h., says to observe the period l

recorder for the indication that it is within its operating range.

j Contrary to the above, on October 26, 1993, a licensed reactor operator failed i

to observe the reactor period meter or period strip chart recorder during the startup and operation as required by procedure.

7 This is a Severity Level IV violation (Supplement I).

l The inspection showed that steps had been taken to correct the identified

)

violation and to prevent recurrence. Consequently, no reply to the violation I

is required and we have no further questions regarding this matter.

1 Dated at Glen Ellyn, Illinois I

this tc ' day of December 1993 C

y 4

i i

I l

3 Dft If0$CKO5000123 91 931206 G