Text
g y4:::4.;
O j
' VERMONT YANKEE NUCLEAR POWER CORPOR ATION P, O. BOX 157 GOVERNOR IIUNT ROAD VERNON, VERMONT 05354 November 10, 1990 VYV 90- 334 U.S., Nuclear. Regulatory Commission
~
- ATTN Document Control Desk
' w a s h i n g t o n=,: D. C.
20555
Dear' Sir:
Submitted' herewith is-..the Monthly Statistical Report for the
.. Vermont Yankee Nuclear' Power Station for the-month of October, 1990.
Very.truly yours, N
VERMONT YANKEE NUCLEAR POWER CORP.
k WarrenP.'Ig/M W(
e urphy Senior Vice Presiden,
perations l-o l
.cc:
1)'USNRC Region.I
~475 Allendale' Road-King of Prussia,.PA 19406
- 2) USNRC.
Resident Inspector, VYNPS DP"0411;Rev. 3 Page:1-of 1 9011130410 901031 ADOCK0500g1
- pop; 1
3 i
?
1 VERMONT YANKEE NUCLEAR POWER' STATION MONTHLY STATISTICAL REPORT 90-10 FOR THE MONTH OF OCTOBER, 1990
.i a
+
J I
\\
l-t-..
i.
DP-'0411.Rev. 3
(
Page.1-of 1 h
i l
l-
(- ;
OPERATING DATA REPORT 1
DOCKET NO.
50-271 DATE 901110 COMPLETED BY G.A.
Wallin-1 TELEPHONE (802)257-7711 l
-OPERATING STATUS
- 1. i Unit Names Vermont Yankee NOTES:
12. - Reporting Period October 3.
Licensed Thermal Power (MWt):
1593 4.
Nameplate Rating (Gross MWe):
540 5.
Design Electrical Rating (Net MWe): 514(oc) 504(cc)
~6.
Maximum Dependable capacity (Gross MWe): 535 7.
Maximum Dependable capacity (Net MWe):
504 3
- 8
_If changes occur in capacity ratings (Items Number 3 through 7)since last report, give reasons:
i N/A
[9.. Power level to: which - restricted, if any(Net MWe):
N/A
?
10 Reasons for restrictions, if.any:
N/A i
This Month Yr-to-Date Cumulative'
,-11.
. Hours InfReporting_ Period 410.43 6079.80 126745.66 745.00 7296.00-12.
Number"Of~ Hours Reactor.was Critical 13.
ReactorLReserve Shutdown Hours 0.00 0.00 0.00 14 '.
Hours Generator On-Line' 379.40 5959.76 123936.83
'15.
. Unit Reserve Shutdown Hours-0.00-0.00 0.00 116..GrosA Thermal ~ Energy; Generated (MWH)- 516063.50 9086921.00 183096477.50 117.
Gross Electrical! Energy Generated 170972.00 3049169.00 61003058.00 18.
Net Electrical ~ Energy = Generated (MWH)163599.00- ~2902177.00 57917876.00
.19.
. Unit Service = Factor 50.93 81.69 78.07 1
- 20. : Unit Availability Factor 50.93 81.69 78.07 l '21 0 Unit capacity Factor (Using MDC Net) 43.57 78.92; 72.38
'22.-. Unit Capacity Factor (Using DER Net) 42.72 77.39 70.98
-23..
Unit Forced; Outage Rate.
0.00' 2.12 5.55
.24.
Shutdowns-scheduled over next 6 months (Type, Date, and. Duration of Each): N/A 25.
If-shut down at end of. report period, estimated date of startup:.N/A
'26.1. Units;In' Test' Status (prior to' commercial operation): N/A i
Forecast Achieved
?
INITIAL CRITICALITY
' INITIAL ELECTRICITY COMMERCIAL OPERATION DP 0411 Rev. 3 Pags 1 of 1
- RT No. 13.F01.19F i
i
?..
H 'l AVERAGE DAILY UNIT POWER LEVEL r
s -
DOCKET NO. 50-271 UNIT Vermont Yankee DATE 901110 COMPLETED BY G.A. Wallin TELEPHONE (802)257-7711 T-MONTH October DAY AVERAGE' DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net)
- 1. -
0 17, 211
--5 2.
0 18, 216 4
3.
0 19, 323 L'
-4.
0 20, 449 5.
0 21.
426
~
6.
0 22, 505
- 7.
0 23.
516 8.
0 24.
514 9.-
0 25, 511 10.
0 26.
510
- 11 '.
0 27.
510 12.
0 28.
502 (25 hr. day) 13.
0 29, 514
- 14..
0
'30.
514 15.
0 31.
514 16.
61 s
INSTRUCTIONS:
On.this format, list the average daily unit power level in MWe-Net-for each day in the reporting month.
Compute to the nearest whole megawatt.
~
2
-VYDPr 0411.02 DP'0411 Rev. 3 Page 1 of 1 RT No. 13.F01.18V N
M
(
i' 1
- m.
UNZT NEUTDOWNN ' A!33 POWER ECDUCTION2 DOCIET NO 50-271 REPORT MONTH OCTOBER UNIT NAME Yermont Tankee DATE 901110 COMPLETED BT G.A.
Wallan TELEPHONE (802)257-7711 1
2 Method of License System component Cause and corrective No.
Date Type Dura tion -
Reason Shutting Down JEvent Code Code Action to
( h o u r s, )
Reactor 3 Reportt 4
5 Prevent Recurrence 90-08 901001 S
363.33-C,8 1.
5/A N/A N/A Shutdown for 1990 Refueling /
(Cont)
Maintenance' outage.
90 901016 S
2.27 B
N/A N/A N/A.
N/A Turbane overspeed testing.
1 F: Forced 2 Reason:
3 Method:
4 Exhibit G-Instructions 5: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or, Test.
2-Manual Scram Entry Sheets for Licensee C-Refueling 3-Automatic Scram ' Event Report (LER) File D-Regulatory Restriction 4-Other (Explain)
(NUBEG'0161)
E-Operator Training and License Examination
-- F-Adm i n i s t r a t i ve 5 Exhibit I - Same Scurce VYDPF 0411.03 G-Operational Error (Explain)
DP 0411 Rev. 3
-E-(Explain)
Page
- 1. o f 1
DOCKET NO. 50-271 UNIT Vermont Yankom DATE 901110 COMPLETED BY'G.A. Wallin TELEPHONE (802)257-7711 REPORT MONTH October
SUMMARY
OF OPERATING EXPERIENCES Highlights Vernont Yankee operated at 43.5% of rated thermal power for the month.
' Gross-electrical generation was 170,972 MWHe or 42.5% design electrical capacity.
Oparating Summary The following is a chronological description of plarat operations including other pertinent items of interest for the month:
At'the beginning of the reporting period the plant was operating at 00.0%
of rated thermal power.
901014~ At 2234 hours0.0259 days <br />0.621 hours <br />0.00369 weeks <br />8.50037e-4 months <br />,:the-reactor was critical.
901016 At 0320 hours0.0037 days <br />0.0889 hours <br />5.291005e-4 weeks <br />1.2176e-4 months <br />, the turbine-generator was phased.to the grid.
901016 At 0823 hours0.00953 days <br />0.229 hours <br />0.00136 weeks <br />3.131515e-4 months <br />, the turbine-generator was removed from the grid for testing.
(See Unit Shutdowns and Power Reductions) 901016 At 1039 hours0.012 days <br />0.289 hours <br />0.00172 weeks <br />3.953395e-4 months <br />,'the-turbine-generator was phased to the grid following testing and a return to full power was initiated.
=At'the end of the reporting period the plant-was operating at 99.9% of rated thermal--power.
VYDPr 0411.04 DP.0411 Rev. 3.
Page 1 of 1 RT No. 13.rO1.18x
.