ML20058E589

From kanterella
Jump to navigation Jump to search
Forwards Results of SG Tube Isis,Per TS 4.4.5.5.b,including Number & Extent of Tubes Inspected,Location & Percent of wall-thickness Penetration for Each Indication of Imperfection & Identification of Tubes Plugged
ML20058E589
Person / Time
Site: Beaver Valley
Issue date: 11/18/1993
From: Sieber J
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9312070070
Download: ML20058E589 (100)


Text

{{#Wiki_filter:__ \\ Q Beaver Vahey Power Station Shippingport. PA 15077-Ot%4 JOHN D SIEBER (412) 393-5255 ) Sensor Vice President and Fan (412) 643-8069 Chief Nuclear Officer Nuclear Power Div.sio" November 18, 1993 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

Subject:

Beaver Valley Power. Station, Unit No. 1 and No. 2 BV-1 Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 Steam Generator Tube Inservice Inspection Report This letter forwards the results of the steam generator tube inservice inspections as required by Technical Specification 4.4.5.5.b for each Beaver Valley unit. The enclosed Unit 1 and Unit 2 reports are supported by Attachments 1 through 6 and include the following information: a) number and extent of tubes inspected, b) location and percent of wall-thickness penetration for each indication of an imperfection, and c) identification of tubes plugged. If you have any questions, please contact Mr. Steve Sovick at (412) 393-5211. Sincerely, l -l / at J. D. Sieber N. cc: Mr. L. W. Rossbach, Sr. Resident Inspector Mr. T. T. Martin, NRC Region I Administrator Mr. G. E. Edison, Project Manager y ;;. ; .ELECTRK 0oon 3~ unuryor THE YEAR, 9312070070 931118 4 ~ PDR ADOCK 05000334 h I 1 0 PDR t. llg -i a

i Beaver Valley Power Staticm

  • Ikiit #1 Ninth Refueling Outage (Attachments 1 through 3)

One hundred percent (100%) of the inservice tubes in each steam generator (RC-E-1A, -1B, -1C) were examined full length with bobbin coil probes. Bobbin coil acquisition speed was 24 inches per secoM. RN 1 and 2 U-bends were examined using Rotatirg Pancake Coil (RPC) techniques. All examinations / analyses were performed in compliance with the Beaver Valley Power Station Unit #1 Technical Specifications, NRC Regulatory Guide 1.83, the EPRI Steam Generator Examination Guidelines (Rev. 3) and the NED/ISI Steam Generator Analysis Guidelines, ISIEl-7 (Rev.

1). All analysts were required to pass a site specific performance denonstration prior to analyzing any eddy current data from the current outage.

The following table summarizes the results of the examinations: S/G "A" S/G "B" S/G "C" MJBES EXAMINED (BOBBIN) 2882 3086 3144 IOCATIONS EXAMINED (RPC) 700 415 309 HJBES REMOVED FROM SERVICE 221 197 150 Additional Examinations: The Zetec 3-coil RPC probe was used on a seven hundred fifty (750) tube random sample of the Wextex expansion transition region in each steam generator. This examination was performed in accordance with the Westinghouse O.Tmr's Group (WOG) reccrrendations for examination of the Wextex region. No indications of the Wextex cracking mechanism were identified. Five hundred and eight (508) mWk and Wilcox rolled plugs were examinal using a RPC probe. Thirty six (36) plugs (1 from Ht. #7042; 35 from Ht. #2848) were renoved from the generators for exhibitire crack-like indications. All replacement plugs were fabricated from Inconel 690 material. Sixty-two (62) Westinghouse Plug-in-Plug (PIP) retainers were visually examined. No indications were observed. A remote visual examination of the inlet aM outlet nozzle inner radius areas was performed. This examination met the requirements of ASME Section XI (IWA-2211c) and satisfies DLC relief request #BV1-B3.140-1 Rev.1. There were no indications observed.

Deaver Valley Power Station

  • Unit /2 Fourth Refuelirg Outage (Attachments 4 through 6)

One hurdred percent -(100%) of the inservice tubes in each steam generator (2RCS-SG21A, -SG21B, -SG21C) were examined full length with bobbin coil probes. Bobbin coil acquisition speed was 24 inches per second. Row 1 and 2 U-bends were examined using Rotating Pancake Coil (RPC) techniques. All examinations / analysis were performed in compliance with the Beaver Valley Power Station Unit #2 Technical Specifications, NRC Regulatory Guide 1.83, the EPRI Stean Generator Examination Guidelines (Rev. 3) and the NED/ISI Steam Generator Analysis Guidelines, ISIEl-8 (Rev. 2). All analysts were required to pass a site specific performance demonstration prior to analyzing any eddy current data frce the current outage. The follcuing table sunmarizes the results of the examinations: S/G "A" S/G "B" S/G "C" TUBES EXN4INED (BOBBIN) 3365 3369 3361 LOCATIONS EXAMINED (RPC) 315 368 512 TUBES REMOVID FROM SERVICE 34 25 29 Additional Pxaminations: The Zetec 3-coil RPC probe was used on a one hundred fifty (150) tube randam sample of the tubesheet expansion transition region in each steam generator. No indications were identified. Six (6) MWk and Wilcox rolled plugs were examined using a RPC prote. The 6 plugs were removed from the generators for exhibiting crack-like indications. Replacement plugs were fabricated from Inconel 690 material. Eighteen (18) Westinghouse Plug-in-Plug (PIP) retainers were visually examined. No indications were observed. Eight (8) tubes regaired stabilization as a result of foreign objects wear against the tubes. These tubes were also renoved from service. W

i i i i ATTACHMENT 1 l CSIT #1 i r 9TH REXELING OLTAGE STEAM GENERATOR "A" 4 9 i RC-E-1 A>1 [ I f h

l-l BWNS TUBAN II (Version 1.0) 10/22/1993.14:06:17 Beaver Valley Unit 1

.e..............

sg A 4/93 RFO Page 1 of 17 STEAM GENERATOR A (RC-E-1A) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A 1 4 ODI 29 TSH +17.89 Bobbin SG A 1 5 ODI 22 TSH +17.83 Bobbin SG A 1 6 ODI 27 TSH +17.61 Bobbin l SG A 1 19 ODI 30 O1H +0.22 Bobbin i SG A 1 26 DSI O1H -0.03 Bobbin SG A. 1 30 DSI O1H -0.14 Bobbin SG A 1 70 DNG Olc +33.94 Bobbin SG A DSI O1H -0.19 Bobbin SG A SAI O1H -0.07 MRPC 9R DSI's SG A 1 94 ODI 24 TSC +17.81 Bobbin l SG A 2 11 DSI O2H -0.11 Bobbin SG A 2 14 DSI 02H -0.11 Bobbin SG A 2 16 ODI 25 01H +0.03 Bobbin SG A 2 24 DSI O1H -0.28 Bobbin SG A DSI 02H -0.08 Bobbin SG A 2 30 DSI O1H -0.08 Bobbin SG A 2 33 DSI 03H -0.06 Bobbin SG A 2 36 DSI O1H +0.00 Bobbin SG A 2 37 ODI 23 O1H -0.23 Bobbin SG A 2 38 DSI O1H -0.06 Bobbin SG A 2 40 DSI O1H -0.11 Bobbin SG A 2 44 DSI O1H +0.03 Bobbin SG A SAI O1H -0.05 MRPC 9R DSI's SG A 2 50 DSI O1H +0.06 Bobbin SG A 2 53 DSI O1H +0.06 Bobbin SG A 2 57 DSI O1H +0.00 Bobbin SG A SAI O1H +0.05 MRPC 9R DSI's SG A 2 69 ODI 24 O1H +0.03 Bobbin SG A 2 70 DSI 02H +0.03 Bobbin SG A 2 85 DSI 03H -0.08 Bobbin SG A 2 86 DSI 02H -0.05 Bobbin SG A 2 92 DSI 01H -0.03 Bobbin SG A SAI O1H +0.02 MRPC 9R DSI's SG A 2 93 ODI 10 02C -0.06 Bobbin SG A ODI 30 01C -0.09 Bobbin SG A 3 3 DSI 02H +0.08 Bobbin SG A 3 9 DSI O1H +0.00 Bobbin SG A 3 11 DSI 02H -0.11 Bobbin SG A 3 19 DSI 02H -0.14 Bobbin SG A 3 20 DSI O1H -0.14 Bobbin SG A DSI 02H -0.11 Bobbin SG A MAI O1H +0.01 MRPC 9R DSI's SG A SAI 02H -0.08 MRPC 9R DSI's SG A 3 21 DSI O1H -0.19 Bobbin SG A 3 24 DSI O1H +0.00 Bobbin SG A MAI O1H +0.01 MRPC 9R DSI's SG A 3 26 DSI O1H -0.11 Bobbin SG A MAI O1H +0.02 MRPC 9R DSI's SG A 3 32 DSI O1H +0.06 Bobbin SG A SAI O1H +0.01 MRPC 9R DSI's SG A 3 35 DSI O1H -0.17 Bobbin SG A 3 36 DSI O1H -0.22 Bobbin SG A 3 47 DSI 01H -0.03 Bobbin SG A DSI 03H +0.06 Bobbin SG A 3 63 DSI O1H +0.00 Bobbin SG A DSI 02H -0.13 Bobbin SG A ODI 27 07H +0.00 Bobbin SG A 3 85 DSI O1H +0.02 Bobbin SG A SAI O1H +0.10 MRPC 9R DSI's SG A 4 1 DSI O1H +0.12 Bobbin SG A 4 9 DSI O1H +0.12 Bobbin SG A DSI 02H +0.00 Bobbin SG A ODI 10 Olc -0.09 Bobbin SG A SA! O1H +0.12 MRPC 9R DSI's SG A 4 10 DSI 01H +0.06 Bobbin (

3 ~ L! BWNS TUBAN II (Version 1.0) 10/22/1993 14:06:17 - Beaver Valley Unit 1

                          • =**

so A { 4/93 RFO l L Page 2 of 17 STEAM GENERATOR A (RC-E-1A) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A DSI 02H -0.03 Bobbin f SG A 4 17 DSI O1H +0.00 Bobbin SG A 4 19 DSI O1H -0.06 Bobbin SG A SAI O1H -0.05 MRPC 9R DSI's i SG A 4 30 DSI O1H +0.00 Bobbin SG A 4 33 DSI O1H +0.00 Bobbin SG A DSI 02H +0.03 Bobbin SG A ODI 40 03H -0.12 Bobbin SG A 4 34 DSI O1H -0.09 Bobbin SG A MAI O1H -0.06 MRPC BR DSI's SG A 4 35 ODI 63 O1H -0.09 Bobbin SG A 4 37 DSI O1H +0.00 Bobbin SG A MAI O1H +0.01 MRPC BR DSI's SG A 4 38 DSI O1H +0.11 Bobbin SG A 4 40 DSI O1H +0.00 Bobbin SG A DSI 03H +0.00 Bobbin i SG A MAI O1H -0.05 MRPC 9R DSI's I SG A SAI' 03d -0.06 MRPC 9R DSI's SG A 4 49 MAI O1H -0.14 MRPC BR DSI's SG A 4 53 DSI O1H +0.05 Bobbin i SG A 4 54 DSI O1H -0.03 Bobbin { SG A 5 1 DSI O1H +0.06 robbin SG A 5 3 ODI 60 O1H +0.00 Bobbin SG A 5 11 DSI O1H +0.03 Bobbin SG A 5 19 DSI O1H +0.03 Bobbin SG A 5 22 DSI O1H +0.00 Bobbin SG A MAI O1H -0.01 MRPC 9R DSI's ] SG A 5 25 DSI 02H +0.00 Bobbin SG A 5 29 ODI 36 04H -0.06 Bobbin SG A ODI 63 01H -0.09 Bobbin SG A 5 30 DSI 03H -0.12 Bobbin SG A ODI 27 O1H -0.09 Bobbin l SG A 5 31 ODI 49 01H -0.06 Bobbin SG A 5 32 DSI O1H -0.06 Bobbin SG A SAI O1H +0.02 MRPC 9R DSI's .) SG A 5 34 DSI O1H -0.09 Bobbin L! SG A 5 40 DSI O1H +0.06 Bobbin ? SG A 5 42 DSI O1H +0.06 Bobbin i SG A DSI 02H +0.14 Bobbin 5 SG A SAI O1H -0.07 MRPC 9R DSI's l SG A 5 43 DSI 02H +0.00 Bobbin i SG A 5 51 DSI O1H +0.00 Bobbin SG A MAI O1H -0.08 MRPC BR DSI's SG A 5 54 DSI O1H +0.03 Bobbin SG A DSI 02H +0.06 Bobbin SG A MAI O1H +0.00 MRPC BR DSI's SG A SAI O2H +0.14 MRPC.9R DSI's SG A 5 66 DSI O1H +0.03 Bobbin l SG A 5 73 DSI O1H +0.00 Bobbin SG A 5 79 DSI O1H +0.06 Bobbin SG A 5 81 ODI 69 OIH +0.03 Bobbin SG A 6 6 DSI O1H +0.03 Bobbin l SG A 6 9 DSI 03H -0.03 Bobbin' SG A 6 12 DSI O1H +0.06 Bobbin i SG A MAI O1H +0.00 ERPC 9R DSI*s SG A 6 15 DSI O1H +0.00 Bobbin l SG A SAI O1H -0.11 MRPC 9R DSI's SG A 6 17 DSI O1H +0.06 Bobbin' SG A 6 18 DSI O1H -0.03 Bobbin SG A MAI O1H +0.01 MRPC BR DSI's SG A 6 21 ODI 77 O1H +0.00 Bobbin '{ SG A 6 23 DSI 02H +0.00 Bobbin SG A 6 26 DSI O1H +0.09 Bobbin SG A DSI 02H -0.06 Bobbin SG A MAI O1H +0.09 MRPC 9R DSI's er-

i BWNS TUBAN II (Version 1.0) 10/22/1993 14:06:17 Beaver Valley Unit 1 so A 4/93 RFO i j .e*****.. l } l Page 3 of 17 j STEAM GENERATOR A (RC-E-1A) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE l r SG A 6 28 DSI O1H -0.06 Bobbin l SG A MAI O1H +0.03 MRPC 9R DSI*s SG A 6 29 DSI O1H +0.06 Bobbin l SG A 6 35 DSI O1H +0.00 Bobbin SG A 6 44 DSI O1H +0.06 Bobbin SG A 6 48 DSI O1H -0.06 Bobbin SG A SAI O1H -0.04 MRPC 8R DSI's SG A 6 50 DSI O1H -0.09 Bobbin SG A 6 59 DSI O2H +0.18 Bobbin SG A 6 60 DSI 01H +0.00 Bobbin SG A DSI 02H +0.09 Bobbin SG A SAI O1H +0.04 MRPC BR DSI's i SG A 7 2 DSI 04H +0.09 Bobbin i SG A 7 5 DSI 03H +0.03 Bobbin SG A DSI 07H +0.03 Bobbin SG A 7 B DSI O1H +0.06 Bobbin SG A DSI 02H +0.06 Bobbin SG A SAI O1H -0.07 MRPC 9R DSI's j SG A 7 10 DSI 02H +0.15 Bobbin SG A DSI 03H -0.06 Bobbin 5 SG A SAI 03H -0.10 MRPC 9R DSI's SG A 7 11 DSI O1H -0.06 Bobbin SG A 7 18 DSI O1H' +0.06 Bobbin SG A 7 25 DSI O1H +0.09 Bobbin SG A MAI O1H -0.10 MRPC 9R DSI's ? SG A 7 29 DSI 02H -0.15 Bobbin SG A ODI 42 O1H -0.03 Bobbin t SG A 7 36 DSI 03H +0.03 Bobbin SG A 7 37 DSI O1H +0.00 Bobbin l SG A DSI 02H -0.06 Bobbin SG A 7 42 ODI 84 O1H +0.00 Bobbin' } SG A MAI 01H -0.09 MRPC BR DSI's l' SG A 7 43 DSI 01H -0.09 Bobbin SG A 7 44 DSI O1H -0.12 Bobbin SG A DSI 02H +0.09 Bobbin i SG A SAI O1H -0.02 MRPC 9R DSI's SG A SAI 02H -0.02 MRPC 9R DSI's .I SG A 7 53 DSI 02H +0.06. Bobbin. l SG A ODI 32 O1H +0.00 Bobbin SG A 7 54 DSI O1H +0.00 Bobbin ( SG A DSI 02H +0.00 Bobbin t SG A SAI O1H -0.07 MRPC 9R DSI's i SG A SAI 02H -0.13 MRPC 9R DSI's SG A 7 56 DSI O1H -0.09' Bobbin SG A DSI 02H +0.00 Bobbin SG A 7 68 DSI 02H +0.03 Bobbin SG A 7 80 DSI O1H -0.06 Bobbin i SG A 8 4 DSI O1H +0.03 Bobbin SG A DSI 02H +0.06 Bobbin SG A SAI O1H +0.08 MRPC 9R DSI's SG A 8 5 DSI O1H +0.09 Bobbin i SG A DSI O1H +0.06 Bobbin i SG A DSI 02H +0.03 Bobbin l SG A DSI 02H +0.06 Bobbin _l SG A DSI 03H +0.09 Bobbin 1 SG A DSI 03H +0.09 Bobbin ? SG A SAI 03H +0.11 MRPC BR DSI's l SG A 8 ~6 DSI 02H +0.09 Bobbin SG A DSI 02H +0.06 Bobbin i SG A 8 10 DSI 01H +0.03 Bobbin SG A DSI 01H +0.06 Bobbin SG A 8 16 ODI 37 01H +0.15 Bobbin i SG A 8 24 ODI 31 01H -0.09 Bobbin l SG A MAI 01H +0.07 MRPC BR DSI's SG A B 25 DSI 04H -0.12 Bobbin I J t

BWNS TUBAN II (Version 1.0) 10/22/1993 14:06:17 Beaver Valley Unit 1-i +..........**.. so A 4/93 RFO g t Page 4 of 17 STEAH GENERATOR A (RC-E-1A) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A 8 27 PVN 02C +46.94 Bobbin SG A 8 34 ODI 79 TSH +0.29 Bobbin SG A 8 36 DSI 04H -0.03 Bobbin SG A ODI 36 O1H +0.00 Bobbin i SG A 8 54 DSI O1H -0.09 -Bobbin SG A 8 56 DSI O1H -0.06 Bobbin SG A MAI O1H -0.01 MRPC 9R DSI's SG A 8 59 DSI 02H -0.03 Bobbin SG A 8 62 DSI O1H +0.00 Bobbin i SG A-DSI 02H -0.06 Bobbin SG A MAI-O1H -0.12 MRPC 9R DSI's SG A 8 68 DSI O1H +0.00 Bobbin SG A 8 76 DSI O1H +0.12 Bobbin SG A MAI O1H -0.01 MRPC BR DSI's SG A 8 80 DSI O1H +0.03 Bobbin SG A 8 86 ADR TSH +7.05 Bobbin SG A VOL TSH +5.23 MRPC Special In SG A 9 2 EXP Olc +0.00 Bobbin i SG A EXP 02C +0.00 Bobbin SG A ODI 25 02C -0.05 MRPC Special In SG A 9 5 DSI O1H +0.15 Bobbin SG A 9 7 DSI O1H +0.09 Bobbin SG A DSI 02H +0.03 Bobbin SG A 9 8 DSI 02H +0.03 Bobbin SG A 9 9 DSI 03H +0.00 Bobbin SG A 9 11 DSI 03H +0.06 Bobbin SG A 9 14 DSI 02H +0.03 Bobbin SG A-9 15 DSI O1H +0.09 Bobbin ,i SG A SAI O1H +0.03 MRPC 9R DSI's v SG A 9 16 DSI 02H +0.00 Bobbin SG A 9 17 DSI 02H +0.03 Bobbin SG A 9 19 DSI O1H +0.09 Bobbin SG A MAI O1H -0.01 MRPC 8R DSI's SG A 9 21 DSI O1H -0.09 Bobbin SG A 9 23 DSI O1H +0.09 Bobbin SG A 9 24 ODI 15 01H +0.21 Bobbin SG A 9 31 DSI O1H +0.06 Bobbin i SG A SAI CIH -0.08 MRPC 9R DSI's SG A 9 32 DSI O1H +0.03 Bobbin SG A DSI 02H +0.09 Bobbin SG A ODI 75 TSH +0.65 Bobbin f SG A 9 36 DSI 03H -0.06 Bobbin SG A ODI 9 TSH +0.57 Bobbin SG A 9 57 DSI O1H -0.06 Bobbin SG A DSI 02H +0.06 Bobbin SG A 9 75 DSI O1H +0.00 Bobbin SG A 9 77 DSI O1H +0.06 Bobbin SG A MAI O1H -0.07 MRPC BR DSI's SG A 9 83 DSI O1H +0.09 Bobbin SG A 9 84 ODI 35 03E +0.00 Bobbin SG A 9 86 DSI 02H +0.06 Bobbin SG A SAI 02H +0.00 MRPC BR DSI's SG A 9 88 DSI 02H +0.17 Bobbin SG A 10 3 DSI O1H +0.06 Bobbin SG A 10 4 DSI O1H +0.21 Bobbin SG A DSI 02H- +0.00 Bobbin SG A 10 7 DSI O1H +0.06 Bobbin SG A MAI O1H -0.20 MRPC 9R DSI's SG A 10 8 DSI O1H +0.00 Bobbin SG A SAI O1H -0.13 MRPC 9R DSI's SG A 10 10 DSI 01H +0.09 Bobbin SG A SAI O1H +0.00 MRPC 9R DSI's SG A 10 15 DSI O1H +0.09 Bobbin SG A SAI O1H +0.00 MRPC BR DSI's SG A 10 18 DSI O1H +0.03 Bobbin i n

l BWNS TUBAN II (Version 1.0) 10/22/1993 14:06:17 Beaver' Valley Unit 11 i So A ....e* I 4/93 RFO

        • e..**.......

Page 5 of 17 i STEAM GENERATOR A (RC-E-1A) 9R INDICATIONS GEN ROW COL IND '%TW LOCATION TEST TYPE l SG A DSI 02H -0.06 Bobbin SG A 10 21 DSI O1H +0.06 Bobbin SG A 10 23 ODI 11 O1H +0.03 Bobbin SG A 10 26 DSI O1H +0.00 Bobbin SG A MAI O1H -0.15 MRPC 8R DSI's SG A 10 30 DSI O1H +0.06 Bobbin SG A 10 31 ODI 24 O1H -0.12 Bobbin SG A 10 32 DSI O1H +0.09 Bobbin SG A ODI 5 TSH +1.41 Bobbin i SG A 10 33 NOI TSH +0.80 Bobbin SG A ODI 11 TSH +0.80 Bobbin SG A SAI TSH. +0.66 MRPC TSH Wextex SG A 10 36 DSI 02H +0.09 Bobbin 3 SG A ODI 5 TSH +0.66 Bobbin SG A ODI 26 O1H +0.00 Bobbin -j SG A 10 37 ODI 53 TSH +1.14 Bobbin SG A 10 40 ODI 43 TSH +0.76 Bobbin SG A 10 41 ODI 43 TSH +1.43 Bobbin SG A 10 44 ODI 52 TSH +0.87 Bobbin SG A 10 45 ODI 70 TSH +1.33 Bobbin SG A 10 51 ODI 24 O1H +0.00 Bobbin SG A 10 52 DSI O1H +0.06 Bobbin SG A SAI O1H -0.04 MRPC 9R DSI's SG A 10 54 DSI 02H +0.00 Bobbin SG A 10 55 DSI' 02H +0.00 Bobbin l SG A 10 57 DSI O1H +0.00 Bobbin SG A 10 60 DSI O1H +0.06 Bobbin SG A 10 63 DSI 01H +0.00 Bobbin SG A 10 66 DSI O1H +0.09 Bobbin SG A SAI O1H -0.09 MRPC 9R DSI's SG A 10 76 DSI O1H -0.03 Bobbin SG A 10 77 DSI O1H +0.00 Bobbin l SG A 11 4 DSI O1H +0.09 Bobbin i SG A EXP Olc +0.00 Bobbin SG A EXP 02C +0.00 Bobbin SG A ODI 13 01C -0.07 MRPC Special In SG A 11 7 ODI 48 01H -0.12 Bobbin SG A 11 11 DSI O1H -0.06 Bobbin SG A 11 13 DSI~ 03H +0.03 Bobbin SG A 11 16 DSI 02H +0.06 Bobbin SG A 11 17 DSI O1H -0.09 Bobbin SG A SAI O1H +0.04 MRPC 9R DSI's SG A 11 18 DSI O1H -0.03 Bobbin SG A SAI O1H -0.12 MRPC 9R DSI's SG A 11 19 DSI OIH +0.00 Bobbin SG A MAI O1H -0.02 MRPC SR DSI's SG A 11 21 ODI 11 01H +0.00 Bobbin SG A 11 26 DSI O1H +0.03 Bobbin i SG A 11 27 DSI O1H .~0.03 Bobbin SG A 11 28 DSI O1H +0.00 Bobbin l SG A 11 32 ODI 34 TSH +1.56 Bobbin 'I SG A Il 33 ODI 64 TSH +1.46 Bobbin a SG A 11 37 DSI O1H +0.00 Bobbin SG A ODI 65 TSH +2.04 Bobbin l SG A 11 39 ODI 57 TSH +1.26 Bobbin i SG A 11 40 ODI 67 TSH +1.10 Bobbin i SG A 11 42 ODI 38 TSH +2.02 Bobbin SG A 11 44 ODI 21 TSH +1.88 Bobbin SG A ODI 32 TSH +1.50 Bobbin SG A 11 46 DSI 01H -0.09 Bobbin SG A ODI 45 TSH +1.60 Bobbin SG A 11 47 DSI O1H +0.00 Bobbin SG A 11 55 DSI O1H +0.06 Bobbin SG A II -59 DSI O1H +0.03 Bobbin SG A DSI 02H +0.17 Bobbin

BWNS TUBAN II (Version 1.0) 10/22/1993'14:06:17 Beaver Valley Unit 1 so A -.w............... 4/93 RFO l f Page 6 of 17 STEAM GENERATOR A (RC-E-1A) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE i SG A MAI O1H +0.01 MRPC BR DSI's SG A 12 4 EXP Olc +0.00 Bobbin SG A EXP 02C +0.00 Bobbin SG A ODI 9 02C +0.21 MRPC Special In SG A 12 11 DSI 02H +0.18 Bobbin SG A SAI 02H +0.09 MRPC 9R DSI's SG A 12 15 DSI O1H +0.03 Bobbin SG A 12 21 DSI O1H -0.03 Bobbin SG A SAI 01H -0.13 MRPC 8R DSI's SG A 12 23 DSI O1H +0.00 Bobbin l' SG A 12 26 DSI O1H +0.09 Bobbin SG A SAI O1H -0.02 MRPC 9R DSI's SG A 12 32 ODI 50 TSH +1.13 Bobbin SG A 12 33 ODI 40 TSH +1.69 Bobbin i SG A ODI 46 TSH +1.49 Bobbin. SG A 12 44 ODI 45 TSH +2.81 Bobbin SG A 12 50 DSI O1H -0.09 Bobbin SG A 12 51 DSI O1H +0.00 Bobbin r SG A 12 54 DSI O1H -0.12 Bobbin SG A 12 55 DSI 01H +0.00 Bobbin SG A 12 56 DSI O1H +0.18 Bobbin SG A DSI O2H +0.00 Bobbin SG A 12 58 DSI 01H +0.12 Bobbin f SG A SAI O1H +0.01 MRPC BR DSI's SG A 12 59 DSI O1H +0.15 Bobbin SG A DSI 02H +0.09 Bobbin SG A 12 62 DSI O1H +0.06 Bobbin SG A 12 69-SAI TSH -0.91 MRPC TSH Wextex l SG A 12 70 PVN Olc +23.68 Bobbin SG A 12 78 DSI 02H +0.00 Bobbin SG A 13 9 DSI 01H +0.09 Bobbin SG A 13 12 DSI O2H +0.03 Bobbin' l SG A 13 17 DSI O1H -0.06 Bobbin i SG A 13 21 DSI 02H +0.12 Bobbin SG A 13 22 DSI O1H +0.03 Bobbin SG A SAI O1H -0.04 MRPC 9R DSI's SG A 13 24 DSI O1H +0.00 Bobbin SG A DSI O2H +0.00 Bobbin SG A MAI O1H -0.01 MRPC 9R DSI's SG A 13 29 DSI O1H -0.03 Bobbin SG A 13 30 ODI 51 TSH +1.22 Bobbin SG A 13 35 ODI 56 TSH +2.14 Bobbin SG A 13 37 ODI 37 TSH +2.47 Bobbin SG A 13 41 ODI 77 TSH +1.76 Bobbin 4 SG A 13 47 DSI 01H +0.09 Bobbin SG A 13 56 DSI O1H. -0.06 Bobbin i SG A 13 67 DSI 01H +0.00 Bobbin SG A 13 75 DSI O1H +0.21 Bobbin 1 SG A DSI 02H -0.09 Bobbin SG A SAI O1H -0.12 MRPC 9R DSI's SG A 14 3 ODI 25 Olc -0.06 Bobbin 4 SG A 14 5 EPI Olc -0.06 Bobbin l SG A EXP O2C +0.00 Bobbin SG A ODI 34 Olc +0.00 MRPC Special In SG A 14 6 DSI O1H +0.00 Bobbin SG A MAI O1H -0.20 MRPC 9R DSI's l SG A 14 14 ODI 49 01H +0.00 Bobbin l SG A SAI O1H 40.00 MRPC BR DSI's SG A 14 32 ODI 35 O1H -0.12 Bobbin-1 SG A ODI 57 TSH +1.24 Bobbin SG A MAI O1H +0.11 MRPC BR DSI's SG A SAI TSH +0.93 MRPC Special In 4 SG A 14 33 ODI 9 TSH +1.41 Bobbin SG A SAI TSH +1.45 MRPC Special In SG A SAI TSH +1.58 MRPC Special In i

h BWNS TUBAN II (Version 1.0) 10/22/1993 14:06:17 Beaver Valley Unit 1 sg A ' 4/93 RFO Page 7 of'17' STEAM GENERATOR A (RC-E-1A) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A 14 34 ODI 34 TSH +1.77 Bobbin SG A 14 36 NQI TSH +1.86 Bobbin SG A SAI TSH +1.91 MRPC TSH'Wextex SG A 14 37 ODI 65 TSH +1.49 Bobbin SG A 14 38 ODI 53 TSH +1.35 Bobbin SG A 14 39 ODI 50.TSH +1.40 Bobbin SG A 14 47 ODI 52 TSH +1.14 Bobbin SG A 14 48 ODI 74 TSH +0.91 Bobbin SG A 14 50 ODI 83 TSH +0.73 Bobbin SG A 14 53 DSI O1H +0.09 Bobbin SG A 14 56 DSI O1H ' +0.00 Bobbin SG A MAI O1H -0.01 'MRPC BR DSI's SG A 14 59 DSI O1H ' -0.06 Bobbin SG A 14 63 DSI O1H +0.00' Bobbin SG A MAI O1H -0.09 MRPC 9R DSI's SG A 14 69 DSI. O1H +0.00 Bobbin SG A 14 72 VOL TSH +0.70 MRPC TSH Wextex SG A 14 87 DSI 02H +0.00 Bobbin SG A 14 92 EXP Olc +0.00 Bobbin SG A EXP 02C +0.00 Bobbin SG A ODI 18 Olc -0.11 MRPC Special In SG A 15 10 DSI O1H -0.06 Bobbin SG A DSI 03H +0.00 Bobbin SG A MAI O1H +0.14 MRPC 9R DSI's SG A 15 24 SAI TSH -1.47 MRPC TSH Wextex SG A 15 35 NQI TSH +1.34 Bobbin SG A SAI TSH +1.53 MRPC Special In SG A 15 37 ODI 50 TSH +1.33 Bobbin SG A 15 38 ODI 65 TSH +1.35 Bobbin SG A 15 42 NQI TSH +1.27 Bobbin-SG A SAI TSH +0.78 MRPC TSH Wextex SG A 15 43 ODI 43 TSH +1.20 Bobbin SG A 15 48 NQI TSH +0.62 Bobbin SG A 15 59 DSI O1H +0.03 Bobbin SG A 15 61 DSI O1H -0.03 Bobbin SG A 15 64 MAI O1H +0.09 .MRPC BR DSI's-SG A 15 70 DSI 02H +0.00 Bobbin SG A 16 5 DSI O1H +0.06 Bobbin SG A SAI O1H +0.01 MRPC 9R DSI's SG A 16 12 DSI O1H -0.03 Bobbin SG A DSI O2H +0.03 Bobbin SG A SAI D1H +0.00 MRPC 9R DSI's SG A 16 13 DSI O1H +0.03 Bobbin. SG A DSI 02H +0.22 Bobbin SG A SAI O1H -0.08 MRPC 9R DSI's SG A 16 22 DSI O1H +0.09 Bobbin SG A SAI O1H- +0.10-MRPC 9R DSI's-SG A 16 23 DSI O1H. +0.00 Bobbin-SG A SAI O1H -0.11 MRPC 9R DSI's SG A 16 24 DSI-O1H -0.08 Bobbin SG A SAI O1H -0.12 ' MRPC BR DSI's SG A 16 25 DSI. O1H -0.06 . Bobbin SG A 16 28 DSI O1H +0,03 Bobbin SG A SAI. 01H +0.00. MRPC 9R DSI's SG A -16 32 DSI O1H +0.00 Bobbin-SG A SAI O1H -0.17 MRPC BR DSI's SG A 16 33 ODI 24 TSH +0.79 ' Bobbin SG A 16 34 DSI O1H +0.00 Bobbin SG A 16 35 DSI O1H -0.03 Bobbin SG A SAI O1H -0.15 MRPC 9R DSI's SG A 16 36 ODI 10 TSH +0.77-Bobbin SG A SAI TSH +0.56 MRPC Special In SG A 16-38 ODI 35 TSH +1.06 Bobbin SG A 16 39 DSI O1H +0.00 Bobbin SG A 16 41 ODI 58 TSH +0.93 Bobbin

BWNS'TUBAN II'(Version 1.0) 10/22/1993 14:06:17 Beaver Valley Unit 1 SG A 'f **************** 4/93 RFO Page 8 of 17 STEAM GENERATOR A (RC-E-1A) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A l'6 42 ODI 62 TSH +1.12 Bobbin SG A 16 43 DSI O1H +0.03 Bobbin SG A ODI 39 TSH +1.07 Bobbin SG A 16 45 DSI O1H +0.00 Bobbin-SG A SAI O1H -0.17 MRPC 9R DSI's SG A 16 49 DSI O1H +0.06 Bobbin SG A 16 55 DSI O1H +0.18 Bobbin SG A SAI O1H -0.18 MRPC 9R DSI's SG A 16 5B DSI O1H +0.15 Bobbin SG A 16 59 DSI 02H +0.06 Bobbin SG A 16 85 DSI 02H +0.12 Bobbin SG A DSI 03H +0.00 Bobbin SG A SAI 03H -0.15 MRPC 9R DSI's SG A 17 5 ODI 29 Olc -0.21 Bobbin SG A 17 13 DSI 02H +0.00 Bobbin SG A 17 24 DSI O1H -0.03 Bobbin SG A 17 37 NQI TSH +1.06 Bobbin SG A MAI TSH +0.83 MRPC TSH Wextex SG A 17 39 ODI 77 TSH +1.01 Bobbin SG A 17 40 ODX 60 TSH +0.85 Bobbin SG A 17 41 ODI 58 TSH +0.80 Bobbin SG A 17 42 ODI 26 TSH +0.80 Bobbin SG A 17 43 ODI 54 TSH +0.87 Bobbin SG A 17 44 DSI O1H +0.03 Bobbin SG A 17 45 DSI O1H +0.09 Bobbin SG A MAI O1H -0.07 MRPC 9R DSI's SG A 17 54 DSI O1H +0.03 Bobbin SG A 17 68 OSI 02H +0.09 Bobbin SG A 17 90 EXP 01C +0.00 Bobbin SG A EXP 02C +0.00 Bobbin SG A ODI 26 Olc -0.28 MRPC Special In SG A 18 23 ODI 10 O1H +0.00 Bobbin SG A 18 32 DSI O1H +0.06 Bobbin SG A SAI O1H +0.06 MRPC BR DSI's SG A 18 39 NQI TSH +0.67 Bobbin SG A SAI TSH +0.61 'MRPC.TSH Wextex SG A 18 58 DSI O1H +0.00 Bobbin SG A 18 69 DSI 02H +0.06 Bobbin SG A 18 89 ODI 13 Olc -0.18 Bobbin SG A 19 6 ODI 10 01C -0.21 Bobbin SG A '19 9 DSI 03H +0.09 Bobbin SG A 19 25 DSI O1H +0.00 Bobbin SG A SAI 01H -0.09' MRPC 9R DSI's SG A 19 27 DSI O1H +0.00 Bobbin SG A 19 30 DSI O1H +0.21 Bobbin SG A SAI Ola -0.14 MRPC 9R DSI's SG A 19 35 DSI O1H +0.09 Bobbin SG A SAI 01H +0.01 MRPC 9R DSI's SG A 19 37 DSI O1H +0.15 Bobbin SG A SAI O1H +0.05 MRPC 9R DSI's SG A 19 38 DSI 01H +0.00 Bobbin SG A SAI O1H -0.07 MRPC 9R DSI's. SG A 19 54 DSI O1H -0.06 Bobbin. SG A SAI O1H -0.19 MRPC 9R DSI's SG A 19 82 DSI O1H +0.00 Bobbin SG A DSI 02H +0.00 Bobbin SG a PVN 02H +0.38 MRPC 9R DSI's SG A 20 6 DSI O1H +0.27 Lobbin SG A DSI 03H -0.18 Bobbin t SG A SAI 03H -0.02 MRPC 9R DSI's 'I SG A 20 12 DSI 02H +0.00 Bobbin i SG A DSI 03H -0.03 Bobbin SG A SAI 02H -0.04 MRPC 9R DSI's SG A SAI 03H -0.01-MRPC 9R DSI's SG A 20 19 DSI O2H +0.00 Bobbin l t ? f I

t. (* e rOgNNNMmmm rv 0m.rN eee.oaeea*oeeeeee uc*)u bDQCZ HH w>Qem4oc 4.O-ee*eaeeeeeeeeeee L 1 .e c e eeeeeeeeeeeeeee* 5 >m*4G> Dc4p 1 ee*eeeeeeeeeooee 0oe>e41 lO Mi eeeaoaeeeeoeeoe* u oa*eooeeeeaeeeeo eeeeeeeeoeeeaeee v%eM MEO eeeeeeeeeoeooaee .a eeooeeooeeeeeeoa eee*eoeeeee*eeee Aeo0 m 0e. HN )bMC% OMZNMcHOM C wMUIMIeg-u s 4 mM H%oHOCHHO2)u s QNZ MO3 OOA HZo ab2 AOOtbHO2 HW)ub b><DM s P M0 C ooh mo 0sl + 0. <r W s t e C QOAA4c C u0 C NO Nc oMH 0v% +0.4N QOD44c ~ r E 1 4 ) ~ )u0 C N0 NM anH 0AC +0.0m QOD44c u r: C m0 t N0 MN onH 0N: 40.0W QODA4c s u C C ~ M0 C N0 MW onH 0s% +0.OW QODA4c ~ e C u )V0 C N0 Mf 04% 40.OM QODA4c ~ o2H v E U 0ODAHc )u0 C N0 vO a)uH 0HZ +0.rC10 1 n0 C N0 vN onH 0tC +0.00 0OAA4c e: 5 ~ u u a0 t NO vm anH 0v: +0.0m QO444c u u n S eC 0tC 40.0b r XC0.O mM oMH.m )u0 t e 2CH v# C u0 C NO mN otH 0rZ +0.1n QODA4c e u r E ) 4 )CveH 0H: +0.0O C .%4 O mM oMH.a )u0 C 5O C n0 C N0 mm oMH 0<r: +0.0e 0ODAec u

  • 8 C

)0 t N0 mv anH 0e: +0.0m 0ODA*c r u o u 5 C v c 0e: 10.0r %M%0 oM oMH.e M0 C mCH s C 4 ~ M0 t NO @r o)VH 04Z +0.00 0OD44C r e C )u0 C omH 0NC 10.0m QOD44C ~ C 0sZ 80.0u XMDO mM o)uH.t e l o m0 t MCH a I ~ )u0 C NO Wm o)uH 0 <r : +0.Oo QODA4c o C 3CH 0e% 40.Om XMOO mM a)uH.a )0 C u o vs n W0 C N0 @m o)uH 0H% +0.0@ QOD44c C u0 t N0 cc o3H 0tN +0.0@ E ~ e QOD44c s u l 04C 80.0W EMD0 mM oMH.e e: e ~ M0 C mCH a M0 t NO rO ouH 0mC: i0.0W QOA44C s C ) 8 )0 C NO om onH u ( 0r: +0.rN 0OA44C u <C i 0n% +0.oO mOA44C u0 t Ne rr auH s e e v 14 n ) m0 C Nr N4 oMH 0<e% +0.CO 8 r 0OAA4C 4 m0 C N <e NN olH 0n: +0.oQ QODA4C u e 1 C m0 C Nr Nm oMH-0e% +0.rN E ~ QOAA4C 1 E r u0 C Nr mM onH 0r: +0.0m QODAec n u <C 1 )0 C omH 0N: + 0. OO. 0O A,A e-u e C 5 c )0 C Nc Mv a)UH 0r% + 0. +r CD QOAQ*c u n S e u s t e C n0 C Nr Mm ooh 0nZ +0.0M QOAA4c t m0 C Ne v4 o)uH 0eC +0.0O r: EQODA4c ~ o a0 t Nc v@ o)uH 0r: 40.mN QOAA4c C e e 4C t U e E u0 C Ne v(O o3H 0<r: +0.im QODA4c e e C ) S ~ onH 0HC + 0. t N. QODA4c u e M0 C u0 C N <r mM o2H 0m: +0.OO QODA4c E ) C u E )0 C omH-0<e: 60.0M QOD44c e C 0e: +0.0W lMO0 oM omHne c 30 C o>Z W o sC C. - n0 C Nc mv onH 0<r: +0.0O QOD44c u o C u e 4 C s e C M0 t Ns mm oMH 0<r: +0.0O QO,D44c C M0 C N4 mr ohH 0 <e :C +0.OO QO044c s e t E 04Z +0.OO CM%O mM o)uH.a e M0 C A>2 1 V0 t Ne mm AnH 0e% +0.Om e c U 0ODA4c 4 ) ~ )u0 C Nr 4s oMH s e 04Ce: t0.1m (O444c r Q e c Q>E 0<r: t0.01 XMk0 oM anH.e u M0 C s C )0 C NH 44 u o c E ~ QOD44c o3H 0e% +0.00 u 0v: 10.O4 e .ty 0 oM oMH.a c lCO )0 t c>Z u s 4C (OD4wec m0 C Nc eh o)uH 0<e% +0.O0 s Q o )u0C Nt hO onH 0N% +0.00 QODA4c e u E ~ fv OaH rm C>v +0.00 QODA4c s C )u0 C Ns o e 1 ~ QODA4c u S c ( 1m C>m +0.00 c 8 )0 C . ooh u Q0D44c' n0 C N1 bD omH Or: +0.0c E e eC s 5 c m0 C MCH OH:C 40.ON E4kU oM o)uH m (O ouH OH% +0.Om QOAA4c e0 C Nt s e O ) )u0 C a)uH ONC +0.OW QOD44c ~ s E u0 t MCH ONZ +0.Ov E4.OO mM oMH,o s s ( t ) r E ~ O4U +0.OO QODA4c CC m0 C Nc oD NXA. 4 )0 t wX.A ONO +0.OO QOD44c' u s C ~ M0 C ooh No Ot0 40.<r@ XMCU aOGO44e. f4c s e . ~. Oc: 00.Om QOAA4c )u0 C NN m o)uM .S s eC u0 C NHO OvO +0.OO QOAA4c S ) C ~ u0 C WHC OmO +0.OO QODA4c n e n0 C ooh ee OnO +0.OO CMOO )u.OGO4m 4 Hc e e u <1 i

1 -l 1 BWNS'TUBAN II (Version'1.0)' ~10/22/1993 14:06:17-Beaver Valley Unit 1 so A 4/93 RFO l I Page 10 of 17 STEAH GENERATOR A (RC-E-1A) i 9R INDICATIONS GEN ROW COL IND 4TW LOCATION TEST TYPE i SG A 22 9 ODI 34 01C +0.00 Bobbin l SG A 22 20 DSI 02H -0.03 Bobbin SG A 22 21 ODI 36 O1H +0.09 Bobbin I SG A 22 36 DSI O1H +0.14 Bobbin' SG A MAI O1H +0.00 MRPC 9R DSI's t SG A 22 38 ODI 15 O1H +0.06 Bobbin SG A 22 41 DSI O1H +0.00 Bobbin SG A 22 43 DSI O1H +0.00 Bobbin SG A DSI 02H +0.00 Bobbin SG A 22 44 DSI O1H +0.09 Bobbin SG A SAI O1H -0.02 MRPC 9R DSI's 5 SG A 22 45 ODI 24 01H -0.06 Bobbin SG A SAI O1H +0.00 MRPC 8R'DSI's SG A 22 47 DSI O1H -0.06 Bobbin 6 SG A SAI O1H +0.14 MRPC 9R DSI's SG A 22 53 DSI O1H +0.00 Bobbin r SG A SAI O1H -0.02 MRPC 9R DSI's SG A 22 55 DSI O1H +0.00 -Bobbin SG A SAI O1H -0.05 MRPC 9R DSI's SG A 22 60 DSI O1H +0.00 Bobbin SG A SAI O1H -0.04 MRPC BR DSI's SG A 22 73 DSI 02H +0.00 Bobbin t SG A 23 8 EXP Olc +0.00 Bobbin SG A EXP O2C +0.00 Bobbin SG A ODI 16 Olc +0.06 MRPC Special In ' i SG A 23 9 DSI O1H +0.06 Bobbin i SG A 23 13 DSI 02H +0.06 Bobbin ~! SG A 23 20 DSI O1H +0.06 Bobbin SG A 23 23 DSI O1H +0.03 Bobbin SG A 23 24 ODI -27 02H +0.00 Bobbin l SG A 23 25 DSI O1H -0.03 Bobbin SG A DSI 02H -0.03 Bobbin i SG A 23 29 DSI O1H +0.12-Bobbin SG A ODI 21 02H +0.00 Bobbin SG A 23 34 DSI O1H +0.06 Bobbin SG A 23 35 ODI 18 02H +17.27 Bobbin SG A 23 36 DSI O1H -0.06 Bobbin i SG A DSI 02H -0.06 Bobbin SG A 23 38 DSI O1H +0.06 Bobbin SG A 23 40 DSI C1H +0.06 Bobbin SG A DSI 028 -0.03 Bobbin SG A MAI O1H +0.02' 'MRPC 9R DSI's { SG A 23 42 DSI O1H +0.00 -Bobbin SG A SAI O1H -0.02 MRPC BR DSI's- -l SG A 23 43 DSI O1H +0.00 Bobbin SG A 23 47 DSI O1H -0.03 Bobbin SG A SAI .01H -0.02 MRPC 9R DSI's SG A 23 50 DSI O1H -0.03 Bobbin SG A ODI '16 AV3 +0.00 Bobbin ti SC A ODI 18 AV3 +16.62 Bobbin l SG A SAI. O1H -0.15 MRPC 9R DSI's SG A 23 57 DSI O1H +0.06' Bobbin SG A 23 60 DSI 02H +0.03 Bobbin -f SG 1. 23 67 DSI O1H +0.06 Bobbin + SG t 23 78 DSI O2H +0.09 Bobbin i SG A 24 8 EXP Olc +0.00 Bobbin-SG A-EXP 02C +0.00 Bobbin SG A ODI 18 OIC - +0.00 MRPC Special In i Sr, A ODI 18 02C +0.12 MRPC Special In FG A 24 11 DSI 05H +0.09 Bobbin SG A 24 12 DSI 03H +0.09 Bobbin SG A 24 16 DSI O1H +0.09 Bobbin i SG A 24 19 DSI O1H +0.00 Bobbin SG A 24 21 DSI O1H +0.03 Bobbin SG A 24 22 DSI O1H +0.06 Bobbin j i i

oaeeeeeeeoeoeoee c 4.O-1OgNN%4mmm Hv*O@=eb eeeeeeoeeeeoeeee eeeaoa4eeeeeeeee Q3mM HQC4M HH >eue40C e. r r ~ ( Q 4 DC4p 1 eeeoeeeeoeeaaeoe ~ r ee >NdtQ> QGm>G4 eeaeeeeoeeeeeeee .Mo Ci eeeeeeeeeeeeeoee eeeeeeeeooeeeeee eeee'eoeeeeeeeeee 9Nmm 5tO 4u eeaeoeeeeeeeeeee e e e e e e e e e o e e o e t' o MHWgM OWmWMCHO(C C MU8 Wies-s 0u 4o vv e QeOo 44 4c mM HmAHUCHHOZM e sb2 AOOCPMOm HWMh b>eAM s OWm MO3 UOA HmO e4 v 1 ~ O4m t0.OO 0 ODD 4c M0 C N4 NN AMH ~ M0 C QMH Orm I0.OW f DD4c .fO e 5 ~ 0 ODD 4c O4m +0.4N r c M0 C Nv

  • e 0MH e

4 M0 t Nv

  • W 0MH Orm

+0.0m nODD4c s i 4 C M0 C Nv vh QMH oem +0.0W QODD4c s 4 8 ~ 0ODG4c M0 C N4 mr OQH N4 t>m +0.0O e s 4 ~ M0 C OQH NN C>N +0.0O QODD4c s C s S M0 t OQH NN C>v +0.0O QODD4c M0 C 0QH mr C>H +0.OO QODD4c a E 4 e M0 C Nv m4 0MH Orm +0.em QODD4c S 4 M0 C Ne mm 0MH ONm +0.0O QODD~c E 4 C ~ M0 C Nv @0 QMH ohm +0.0@ QODD4c a E ~ M0 C QMH ONm +0.O0 QODD4c a o4m +0.40 XM.DU msg QMH.e r r M0 t MCH e s v s S ~ 4m C>N t0.0O QODD4C M0 C Nv Qm OOH d (ODD 4C ~ M0 C Nv &o QMH ONm +0.0O Q C ~ M0 C Nv &m QMH ONm +0.0m QODD4c M0 C Ne he QMH ONm +0.0o QODD4c C ~ s ~ M0 C Nm er NMg OrO +0.00 QODD4c S s s1 b 4 S ~ .C *' C WMA ONU +0.04 QODD4c s z. l a tN AMH ONm +0.0@ QODD4c. HC im OrU 10.0m Z;iQO oOGuAl4 r M ** C OQH s 4 E ~ e MO C Nm M0 C QMH ONm +0.OM QODD4c ~ C s r r C ~ 1v QMH ONm +0.4N QODD4c M0 C Nm s (D XC.D mM oMH.a M0 c mCH ONm +0.0M s a ~ M0 C Nm rm AMH ONm +0.0O QODD4C-C S ~ QODD4C m M0 C Nm Ne QMH Orm 80.OQ s 1 4 IQODD4c M0 C Ne NN QMH Orm +0.0O s 4 O4m +0.0O QODD4c r E M0 C QMH e E QODD4c O4m +0.0O M0 C Nm Ne QMH e s (ODD 4c O4m +0.0O. r M0 C Nm m@ QMH Q M0 C Nm mm QMH ONm +0.0O. 0 ODD 4c-s s E QODD4c M0 C Nm mm QMH Oem +0.0Q s e C M0 C Nm ve QMH Orm +0.0M QODD4c a 4 4 O4m +0.0@ QODD4c r C M0 C Nm vN QMH s S ~ M0 C QMH ONm +0.0m QODD4c E ~ QODD4c M0 C Ne vm QMH Ovm +0.Om 4 ~ M0 C Nm vW Q4H Oem +0.No 0 ODD 4c 8 f 4 r 8 O4m +0.Om 0 ODD 4c M0 C Nm vm QmH s XCAD oM oMH.a M0 C MCH Orm 40.Om s C s 4 (ODD c M0 C Nm mm QMH Orm +0.0m s Q 4 e S M0 C QMH ONm +0.0o QODD4c e

  • C

~ M0 C Nm @m OQH m4 C>e t0.O0 QODD4c (ODD 4c: ~ M0 C Nm &r QMH ONm +0.O0 e Q 4 (ODD 4c M0 C N@ @ NMQ. OrO +0.OC Q 4 5 0 ODD 4c M0 ;s NMA ONU +0.Oo 8 ~ 4O OQH om OvU 40.Om 0 ODD 4c M0 C N@ r s M0 C N@ ec QMH Orm t0 Om QODD4c-4 s E ~ 44 4 O4m i0.O4 2%AU mM OMH.e r

sH M0 C lCt

~ O4m +0.OO Q0DD4C C M0 C N@ Nm QMH e Q0DD~C O4m +0.rN C e M0 C N@ NW QMH 4 4 500DD4c M0 C OQH NM C>e +0.0O O4m 60.0v 2 MAD mM QMH.a r M0 C MCH s 8 0 ODD 4c M0 t N@ N& QMH ohm +0.0m s 8 0 ODD 4c M0 M N@ Nm QMH Orm 40.0@ 4 5 M0 C N@ mo QMH Ovm +0.0m 0 ODD 4c s 4 Orm t0.OO QODD4c C M0 C N@ mM QMH s 4 ~ M0 C N@ Me OQH vN C>H t0.OO QODD4c s C 4 SQODD4c 4m C>m +0.OO e M0 C OQH s $0 ODD 4c ~ M0 C OQH Nv C>m +0.OO s M0 C OQH m0 C>e +0 OO QODD4c C ~ I QODD4c e M0 C N@ mm QMH ohm +0.1m M0 C N@ m@ QMH Orm +0.0m QODD~c C e 4 4 (ODD ~c M0 C N@ eco QMH Orm +0.0m s Q 4 4 M0 C MCH Orm 1O.01 XMAU mM QMH.m s e 4 ~

'l 10/22/1993 14:06:17 (Version 1.0) ley Unit 1 fMNS TUBAN II Beaver Val so A ~ 4/93 RFO

                        • =***

s Page 12 of 17 -j STEAM GENERATOR A (RC-E-1A). f 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A 26 51 DSI O1H +0.14 Bobbin' l SG A SAI O1H -0.05. MRPC 9R DSI's l SG A 26 55 SAI O1H -0.04 MRPC BR DSI's SG A 26 67 DSI 02H +0.20 Bobbin l SG A 27 19 SAI O1H -0.07 MRPC BR DSI's SG A 27 21 DSI O1H +0.15 Bobbin SG A 27 31 DSI O1H +0.03 Bobbin SG A 27 32 DSI O1H +0.09 Bobbin SG A 27 38 DSI O1H +0.12 Bobbin SG A 27 40 DSI O1H +0.15 ' Bobbin SG A DSI 02H +0.00 Bobbin SG A 27 53 SAI O1H -0.10 MRPC BR DSI's SG A 27 66 DSI O1H +0.03 Bobbin SG A SAI O1H +0.04 MRPC 9R DSI's SG A 27 75 DSI 04H +0.00 Bobbin SG A SAI 04H -0.05 MRPC 9R DSI's SG A 27 85 EXP 01C +0.00 Bobbin SG A EXP 02C +0.00 Bobbin SG A ODI 19 OIC +0.00 MRPC Special In SG A ODI 24 02C +0.00 MRPC Special In SG A 28 10 ODI 2 02C -0.24 Bobbin SG A ODI 39 Olc -0.06 Bobbin SG A 28 17 DSI O1H +0.03 Bobbin SG A SAI O1H +0.02 MRPC 8R DSI's SG A 28 23 DSI 04H +0.03 Bobbin SG A ODI 29 03H -0.12 ' Bobbin SG A MAI 04H -0.06 MRPC 9R DSI's SG A 28 32 DSI O1H -0.38 Bobbin SG A 28 41 DSI O1H +0.09 Bobbin SG A SAI O1H -0.01 MRPC BR DSI's SG A 28 42 DSI O1H +0.03 Bobbin SG A 28 46 DSI 02H +0.09 Bobbin SG A 28 58 DSI O1H -0.03 Bobbin SG A 28 63 DSI O1H +0.09 Bobbin SG A SAI O1H -0.08 ~ MRPC 9R DSI's SG A 28 69 DSI 02H +0.09 Bobbin SG A 28 71 DSI O2H +0.06 Bobbin SG A DSI 03H +0.06 Bobbin SG A 28 85 EXP Olc +0.00 Bobbin SG A EXP O2C +0.00 Bobbin SG A ODI 12 Olc +0.00 MRPC Special In SG A 29 14 ODI 1 Olc -0.33 Bobbin SG A 29 21 DSI -O1H -0.09 Bobbin SG A MAI O1H +0.00 MRPC BR DSI's SG A 29 23 DSI O1H +0.06 Bobbin SG A DSI 02H +0.03 Bobbin SG A SAI O1H -0.02 MRPC 9R DSI's SG A 29 34 ODI 30 AV4 +0.00 Bobbin SG A 29 44 DSI O1H +0.06 Bobbin SG-A MAI O1H -0.03 MRPC BR DSI's-SG A 29 50 DSI O1H +0.03 Bobbin SG A 29 51 DSI O1H +0.00 Bobbin SG A SAI O1H -0.03 MRPC 9R DSI's ~ SG A 29 60 ODI 14 AV2 +0.00 Bobbin SG A ODI 18 AV3 +0.00 Bobbin SG A 29 61 DSI 02H +0.03 Bobbin SG A 29 62 DSI 02H -0.06 Bobbin SG A 29 64 DSI O1H +0.00 Bobbin SG A 29 84 ODI 7 03C -0.12 Bobbin SG A 30 12 EXP Olc +0.00 Bobbin SG A EXP 02C +0.00 Bobbin SG A 30 13 EXP Olc +0.00 Bobbin SG A EXP 02C +0.00 Bobbin SG A ODI 20 02C +0.00 MRPC Special In SG A 30 14 ODI 7 Olc -0.31 Bobbin ~

BWNS TUBAN II.(Version 1.0) 10/22/1993 14:06:17 Beaver Valley Unit'l Sc A 4/93 pro ~! 1 Page 13 of 17 STEAM GENERATOR A (RC-E-1A) 9R INDICATIONS GEN ROW COL IND STW LOCATION TEST TYPE s SG A ODI 8 02C -0.06 Bobbin SG A 30 16 EXP Olc +0.00 Bobbin l SG A EXP 02C 40.00 Bobbin ~ SG A ODI 18 01C -0.12 MRPC Special In i SG A 30 24 DSI 03H +0.03 Bobbin SG A SAI 03H -0.03. MRPC 9R DSI's SG A 30 29 DSI O1H +0.03 Bobbin SG A 30 33 DSI 02H +0.03 Bobbin SG A 30 37 DSI O1H +0.09 Bobbin SG A 30 39 DSI 02H +0.03 Bobbin SG A VOL TSH -0.91 MRPC TSH Wextex SG A 30 42 DSI O1H +0.09 Bobbin SG A 30 45 DSI 02H +0.18 Bobbin SG A SAI 02H -0.08 MRPC 9R DSI's SG A 30 53 ODI 19 AVI +0.00 Bobbin-SG A ODI 27 AV2 +0.00 Bobbin SG A 30 61 DSI O1H +0.03 Bobbin SG A 30 62 DSI O1H +0.09 Bobbin SG A 30 70 DSI 02H +0.03 Bobbin SG A 30 74 DSI O1H +0.00 Bobbin SG A 30 81 ODI 17 03C -0.14 Bobbin i SG A 31 16 EXP Olc +0.15 Bobbin i SG A EXP 02C +0.39 Bobbin SG A ODI 21 01C +0.00 MRPC Special In SG A 31 20 DSI O1H +0.00 Bobbin SG A MAI O1H -0.01 MRPC BR DSI's SG A 31 23 ODI 36 TSH +32.50 Bobbin SG A ODI 53 TSH 432.97 Bobbin SG A 31 26 DSI 03H +0.21 Bobbin SG A 31 35 ODI 14 AV2 +D.00 Bobbin SG A ODI-15 AV4 +0.00 Bobbin SG A 31 36 DSI O1H +0.12 Bobbin SG A 31 56 DSI O1H +0.00 Bobbin SG A SAI 01H -0.02 MRPC 9R DSI's-SG A 31 69 ODI 22 AV1 +0.00 Bobbin l SG A 31 72 DSI O1H +0.17 Bobbin SG A 31 74 DSI O1H +0.09 Bobbin SG A 32 16 EXP Olc +0.00 Bobbin SG A EXP 02C +0.00 Bobbin SG A ODI 22 Olc +0.15 MRPC Special In SG A 32 32 DSI O1H +0.09 Bobbin SG A ODI '27 AV4 +0.00 Bobbin SG A-ODI 34 AV2 +0.00 Bobbin SG A ODI 35 AV3 +0.00 Bobbin SG A ODI 39 AVI -0.09' Bobbin 1 SG A MAI O1H +0.01 MRPC BR DSI's. i SG A 32 35 DSI O1H +0.06 Bobbin SG A 32 40 DSI O1H +0.12 Bobbin i SG A SAI O1H -0.07 MRPC 9R DSI's SG A 32 45 DSI O1H +0.03 Bobbin SG A SAI O1H +0.00 MRPC 8R DSI's SG A 32 51 DSI O1H -0.03 Bobbin' [ SG A SAI O1H -0.06 MRPC 9R DSI's SG A 33 17 ODI 7 03C' -0.18 Bobbin SG A 33 18 ODI 31 Olc -0.33 Bobbin SG A 33 33 DSI O1H +0.24 Bobbin SG A SAI O1H -0.07 MRPC 9R DSI's i SG A 33 37 DSI O1H +0.15 Bobbin l SG A 33 38 DSI O1H +0.09 Bobbin SG A 33 40 DSI 03H +0.06 Bobbin SG A 33 50 DSI O1H -0.03 Bobbin SG A 33 56 ODI 31 AV1 +0.00 Bobbin SG A ODI 31 AV4 +0.00 Bobbin SG A ODI 38 AV2 +0.00 Bobbin i SG A ODI 40 AV3 +0.00 Bobbin i

I BWNS TUBAN II (Version 1.0) 10/22/1993 14:06:17 l Deaver Valley Unit 1 SG A i i 4/93 RFO l -i Page 14 of 17 i STEAM GENERATOR A (RC-E-1A) l 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE i SG A 34 16 EXP Olc +0.00 Bobbin' SG A EXP 02C +0.00 Bobbin i SG A 34 17 EXP Olc +0.00 Bobbin ~ ^ SG A EXP 02C +0.00 Bobbin SG A ODI 21 Olc +0.00 MRPC Special In SG A 34 20 DSI O1H +0.12 Bobbin l SG A 34 23 DSI O1H +0.15 Bobbin SG A DSI 03H +0.18 Bobbin r SG A ODI 10 05H +0.15 . Bobbin '[ SG A SAI O1H -0.04 MRPC 9R DSI's j SG A 34 26 DSI 02H +0.00 Bobbin SG A 34 27 DSI O1H +0.06 Bobbin SG A DSI O2H +0.06 Bobbin i SG A 34 29 DSI O1H +0.06 Bobbin j SG A DSI 02H -0.03 Bobbin 1 SG A 34 30 DSI O1H +0.03 Bobbin l SG A SAI O1H -0.10 MRPC 9R DSI's SG A 34 31 DSI O1H +0.00 Bobbin SG A MAI O1H -0.04 MRPC 8R DSI's SG A 34 33 LSI O1H +0.00 Bobbin SG A 34 40 DSI 02H +0.00 Bobbin SG A 34 44 DSI-01H +0.09 Bobbin i SG A 34 53 DSI 02H +0.00 Bobbin SG A 34 58 DSI 02H +0.00 Bobbin i SG A 34 60 DSI O1H +0.00 Bobbin SG A DSI O2H +0.00 Bobbin SG A SAI O1H -0.06 MRPC 9R DSI's + SG A 34 64 DSI O1H +0.06 Bobbin SG A DSI 02H +0.00 Bobbin i' SG A 35 17 ODI 34 02C +0.03 Bobbin SG A 35 18 EXP Olc +0.00 Bobbin SG A EXP 02C +0.00 Bobbin SG A ODI 15 02C '40.18 MRPC Special In j SG A 35 19 EXP Olc +0.00 Bobbin SG A EXP 02C +0.00 Bobbin .j SG A ODI 13 Olc +0.00 MRPC Special In SG A 35 28 DSI O1H -0.0? Bobbin SG A DSI 02H +0.13 Bobbin 'l SG A DSI 03H +0.06 Bobbin SG A 35 33 DSI O1H +0.06 Bobbin I SG A 35 70 DSI O1H +0.23 Bobbin SG A DSI 02H +0.17' Bobbin .1 SG A 36 19 ODI 23 Olc -0.28 Bobbin. i SG A 36 20 EXP Olc +0.00-Bobbin SG A EXP 02C +0.00 Bobbin SG A ODI 13 Olc -0.12' MRPC Special In i SG A 36 22 EXP Olc +0.00 Bobbin j SG A EXP 02C +0.00 Bobbin. SG A ODI 27 Olc -0.16 MRPC Special In j SG A 36 23 DSI 03H +0.05 -Bobbin SG A ODI 34 05H +0.05-Bobbin 1 SG A 36 24 DSI O1H +0.08 Bobbin _i SG A DSI 02H +0.08 Bobbin j SG A SAI 02H -0.09 MRPC 9R DSI's SG A 36 25 PVN 02C +34.50 Bobbin-t SG A 36 28 ODI .24 AV2 +0.00 Robbin i ODI 27 AV3 +0.00 Bobbin g SG A _ 36 DSI 02H +0.03 Bobbin - 1 SG A 36 SG A SAI O1H +0.02 MRPC BR DSI's SG A-36 40 DSI 02H +0.00 Bobbin l SG A DSI 03H +0.03 Bobbin SG A 36 41 DSI O2H +0.00 Bobbin l SG A 36 48 DSI 02H +0.06 Bobbin i SG A 36 51 DSI-02H +0.03 Bobbin SG A 36 52 DSI 02H +0.00 Bobbin

a. ,~ >e elm 4Oc t.Oa 4ONNN%4mmM r9.aOe*v& ~ e v v e*eeeeeeseeeeeae c9**m HO2cm H H eeeeeaeeeeeeeoee Q e

  • 4 8

s >444e,> OC44 H e*eaoeeeeeeeeeea ee ~ e4eaeeeeeeeeeeee 0ee> eel t0 C, e*eeeaee*eeoeeae u eeeeeiee4eeeeeee s e*eoaeae*eeeeaea eeoeeeeae*eeaeee 9%em c.nO fi e*eeeeeeeaae*eee eeeeaaeee4oae4ee m v 4& e QeDe 4m 04% vo t WMc, bOCeC MOtWa4c-mHWc,m OWZ,HMOZ)u mM HZOHOC bWnH b>e%W u tO3 OO.1 HZQ ab3 AO0CHHOZ 0WZ c p Q (OA4dc m0 4, me mm QMH 0Nl +0.OO C .~ M0 c. me me Q)uH 0Nm +0.Om QOA04c E n0 c me me QsH 0, Nc: t0.Om QODA4c c C u v m0 c. OOH 1e c,>w t0.OO QO4A4c c C w C ~ 1e c>m t0.OO QO4A4c r n0 c. 0OH u E ~ )0 c m@ e4 0MH ONc: +0.Om QOAA4c u. v m0 c, 0)u H 0,mm 40.O@ QOAA4c C 80 ODD 4c ec +0.OO 4o c>n M0 4 OQH XM%0 cM QnH.e n0 c. H ON: +0.Om u u c o 3 ~ 0OA44c m0 c, m@ Wm Q3H 0Nc: 10.Om u 5 ~ 040 +0.OO 0OD44c r W0 c, m@ &m WM% C ~ )u0 c, NM0 0N0 +0.OO QODA4c ~ c m0 c. m& rm Q)uH 0m: +0.OW QOAQ4c. Hc m0 c, OQH rm 0e0 +0.O& XM%.U. )uQeu 4e 4 4 4 C c 4 tm 0n0 40.NN QODR4c E ~ e m0 c, OQH M0 c. m& NN QtH 0v: +0.ON QODA4c ~ C u c e C ~ 01m +0.O@ QOA44c a0 c. m& m4 u e uH Qs,H 04c +0.OO %MD.0 eM QnH.a r: u uc m0 c, ~ m0 c. m& mc Q1H 0Nm +0.Om 0O444c 5 u n0 c, m& mh Q4H 0Nm +0.Oo QO444c E u m0 c, m& Wm mCH 0N: 10.Ov XM00 mM QnH.e u c ~ a0 4 m& @o oa,H 0Nm +0.O@ QOD44c C u m 0 c,. mCH 0Nc: +0.OO E4%0 oM QhH.e C c u )u0 c M& 2m omH 0<e2 +0.OM QOD44c S E ~ QOD44c m0 < mm Ne WM% 04O +0.O0 e (OA4~c U0 c, WM% 0NO +0.O0 C 4 1 EM%U 3Qeu44e Hc ~ m0 c, OQH o 0NO +0.OO u. t 4 C ~ QODA4c 4e 0mO 40.44 r rr m0 c,, mto Nn OQH 8 ~ m0 c. m(o No OQH No 0eO +0.00 0OAA4c 4 0OAA4c 8 ~ tee 0HO 80.Nm m0 c. mO Nw OQH ( QOA44c e0 c, mO Nm OQH Ne 0H0 I0.44 C rr C e 0 a0 c m(o me O)uH 0mn: t0.0@ 1OA44c E4.U mM a)uH.a u0 e, Mc, H 0m2 +0.C& CQ ) C I )0 c, mO eO QnH 0Nm 40.oW QO4Adc u u 80OA44c 20 4 mo mm Q)uH 0N: +0.oO t U n XM.DO oM o1H.e c r m0 c. Xc,H 0N:c 40.4O U 8 ~ a0 c m o( mm QtH 0Nc: +0.tN 0O0D4c u u r )0 c XeH 0Nc: t0.4W XM%U mCc Q)uH.e U s e E QODA4c m0 c, mo Wto Q)uH 0Nc: t0.0@ s t C )0 c Q)u H 0mM +0.CO QODD4c u m0 < ccH 0n

  • 60.OC cM%0 mM Q)uH.a l

c C 3OD44c QnH 0H2 +0.OO W0 < mCD Wc u n 8QOD44c ~ )0 < QmH 0N: +0.OO u c 0em +0.Om QOD44c C m0 c, mto &O Q)uH e ~ QnH 0nm +0.Om QOA44c E u m0 4, 1 ~ 0OA44c' 04m +0.Oe l0 c mCD &o QtH r u u m0 c, Ec.H 0Hm +0.OO XMC0 mM QhH.m u 5 tew 0MO 40.mt 0OA44c r e W0 c. mm No OQH 8 ~ m0 < OQH Ne 0NO i0.r9 0OAA4c 4 4 8 ~ e 0OAA4c m0 < mm Ne WM0 0eO +0.0O E ~ QOAA4c M0 c, WM0 0NO +0.0O 4O 040 40.4h XM%0 mQeu4Ne.Hc c e r m0 c, 0QH M0 c, mc N& QnH 0N:c +0.0m QOD44c. 4 C u n ~ 0im +0.0e QOAA4c C e )0 < mm Nc 0)uH u o m0 c,, Q)uH 0mc: t0.0M QOAD4c E C ~ M0 c mm mO QlH 0m= +0.0O QODA4c u a M0 c. mm mm QiH 0e:c +0.rM QO444c C u 4 sO444c M0 c. mm mm QnH 0Nt t0.0O u )0 4 AyH 0Nc: +0.0O Ay%O oN otH.m C c u u (0DD4c QnH 0rm +0.0m 30 c, mm mv u U Q Qsu 0N: +0.0O QODA4c - i 4 C Lq, H m0 c. c u r ( E4.0-mM osH.m H 0N:c 10.0m CO u M0 4, M0 c, mm mm QnH 0.rm +0.N4 Q0D4dc-c ~ m0 e QMH 0N:c 4C.OM 40A,44c r E ~ 4O 0No +O.OM Q0D04c M0 < vo Nm OQH

1 .4 eeeeeeeeeeeeeeee ~ b w 4O%NN%rmmm 4v*o@.es eeeeeeeoeeeeeeee A3EM HO8s2 HH .>meniOC 4.o~ v e 0c eeeeaeaeeaeeeeee >n44Wb ~ r eaeeeeoeeeeeaeeo re eeoaeeeeee4eeeee m0 4e OC4p 4 CQoe>D54 6 oeeeeaeeo*eeeeoe m%em 4iO eeeeeeeeoeeeooee .n eeeeeeaae*eeeeee eeeeeeaeeeaeeeee eeeeeeeeeeeeaeee .Aece 4@ mHWcM CW2NE4HO l %OlWI44-i Ow 4et e s s e t mM H2 OHO 4HH0Z.m OWz EO3 0O1-H2O aH3 4O04HHO2 HNmb b><%W p M0 4 OOH et 0v0 40eoW QOD44c S v 4o t M0 4 vo No OOH Nm 0N0 I0.4ee QODA4c. ~ E m0 4 vo Nm nmo. 0e0 t0.0o E QODD4c e 0ODA4c - 5 m0 4 WMo 0NO +0eoc

  • e m0 4 OQH Nm 0N0

+0ooo.. 0e: +oeoo 0OD44c. Hc .hCO0 mOGU4e4 y. e 5 ~ m0 4 vo mv QmH Q 0t% 80ao@ %EO0 mE QmH a r uls H M0 4 t m0 4 vo mo omH 0em +0eom Q0A44c ~ S 0sO +0eoo Q0A44c m0 4 vo f'4 WMA. r r C m0 4 WMA. 0NO +0 oo Q0A44c S ~ r ~ e rr 0NO +o.4m D0 mAGu44n Hc m0 4 OQH iA 04O 60e0m Q0D44c. Nt r@ m0 4 vet e C Mo' OQH 4 WM% 0rO +0 oo Q0D44c ~ M0 4 ve I 4 4 M0 4 WM.o 0NO +0eoo QODA4c ~ C - e <m 0nO +0eoo XEO0 mQGo4m4 Hc e e . ~ M0 4 OQH 1N o4O 10.NN QOD44c. M0 4 vr me OQH e r S 4 4 m0 4 v4 mN OQH NN 4>m +0.oo QOD44c e C 80OD44c m0 4 OQw mm :t>v +0eoo s M0 4 vN Nm WMn 0eU 00et& OODA4c r r C ~ 800DR4c ~ M0 4 WMo. 0NO 00e4& r M0 4 OQH Nm 0N0 80 mm X%O0 m.OGu44e Hc w t M0 4 vN Nm OQH rN 0m0 i0.rb QOA44c C ~ 1 4 M0 4 OQH H@ 0HU +0.oo QOD44c E ~ m0 4 OQM Nm 0NU 0eNm (OD4~c Q 4 (OD4~c m0 4 vN m4 WHO 0HU 10evN e O 4 mL* 4 WM% 0NU 10emm QOD44c C M0 4 OQH Nm 0NU i0 N1 - e e %fO0 u.CGo4e4 Hc .f. e0 4 OQH Mm oeU +0 o0 mQ - e Hc %M%0 c.eu4n4 C a0 4 vN mN WX% 0M0 80.nM QOD44 m0 4 WH% 0N0 +0eoc QOD4,c E 4 m0 4 OQH cm 0m0 40eNN QOD44c C 1 .- e m0 4 OQH N@ oN0 10eHm % EAU mOoo4en Hc E 4N 0N0 +0eom QODAec m0 4 vN mm OQH e m0 4 vN mv MXo 0e0 00eom QOD44c S 4 m0 4 MMa. 0N0 +0.oo. QOD44c ~ S r r - e 1N o<e0 10eio %MO0 maeu4at Hc M0 4 OQH M0 4 vN @n OQH Mm 0mO I0esG. ~ DOD44c r C M0 4 vM mo MMsL 0<e O +0eoo

.OD44c a

5 ~ 0GD44c m0 4 WM% 0NO +0eoO 8 07D44c m0 4 OQH em 0mO 40e4N r 4 4m 0HO +0oem ~ e e e %XCO uOGo4m4 Hc e0 4 OQH L M0 4 OQH Nm 0NO 8oeNv %;0%0 mQGu44e Hc M0 4 vM m4 WXA 0eO +0eoc QOD44c. 4 C e (OA4~c M0 4 WXk 0nO - 00eNM +0eoo Q 4 (0D4 c M0 4 OQH r 0mO Q 4 M0 4 OQH NM 0NO 1ooNN E;0%U.mQGo4e4 Hc e M0 4 vM mm OQH n 0NO. 40eNo QODA4c. S M0 4 vM me OQH e 0<eO +0eom 8 0OD44c er 0m0 40 oW E QOD44c-M0 4 OOH 44 m0 4 vM ee OmH 0N0 +0.om 0OD44c s (ODD 4c W0 4 vv nm ooh Hr 0e0 10eoW Q t@ 0m0 60eNM QOD44c e C W0 4 OOH m0 4 vv mr OOM m 0m0 i0oNM (OD4~c Q 4 A0 4 vv mm OOM rm 0<e0 i0eNo QODAwec C 4 M0 4 vv eo WMA 0H0 +0.oo QODA4c ~ C M0 4 WMi 0N0- +0.oo QOD44c C b M0 4 OQH re 0eO +0.oo %M%0 mQeu e4 Hc e m0 4 vv mm OQM r@ 0mO +0.om QOA44c. 4 1< s s ~ (OD4~c M0 4 vv eo WM.A 0eO +0eoc r Q 4 (0D4~c M0 4 WMo 0nO +0eoo Q 4 w e M0 4 OQH No 0HO 60.o@ %4O.0 m4Oo4n4 Hc ~ m0 4 vv @N WXA o<eO +0eoo QOD44c C M0 4 WMs oNO +0eo0 Q0AA4c E ~ L M0 4 OOH em oN0 +0eo0 E;0DO m.OGo4eH Hc 4 S m0 4 vm mr QmH oN0 +0eNm QODR4c ~ c 1; I I ] lJ)!

=... BWNS TUBAN II (Version 1.0) 10/22/1993 14:06:17 Beaver Valley Unit 1 sg A 4/93 RFO f 1 Page 17 of 17 STEAM GENERATOR A (RC-E-1A) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A PVN 02H +0.15 MRPC 9R DSI's SG A 45 38 ODI 7 03C -0.23 Bobbin SG A 45 39 EXP Olc +0.00 Bobbin SG A EXP 02C +0.00 Bobbin SG A ODI 25 04C -0.03 Bobbin SG A 45 41 ODI 13 02C -0.14 Bobbin SG A 45 44 ODI 15 01C +0.09 Bobbin SG A 45 45 EXP Olc +0.00 Bobbin SG A EXP 02C +0.00 Bobbin-SG A ODI 9 01C +0.00 MRPC Special In i SG A ODI 28 02C -0.14 MRPC Special In SG A 45 50 ODI 11 01C +0.06 Bobbin l SG A 45 52 ODI 6 03C +0.18 Bobbin i SG A 46 42 ODI 30 02C -0.23 Bobbin ~ SG A 46 47 DSI 05H +0.09 Bobbin Total Indications Found = 1055 Total Tubes Found = 647 i a i I f l l 1 1 1 l

a I ) BWNS TUBAN II (Version 1.0) 10/22/1993 09:47:40 Beaver Valley-Unit 1 sg A I 4/93 RFO f Page 1 of 5 STEAM GENERATOR A (RC-E-1A) 9R PLUGGED TUBES GEN ROW COL IND %TW LOCATION TEST TYPE j SG A 1 70 SAI O1H -0.07 MRPC 9R DSI's SG A ~2 44 SAI O1H -0.05 MRPC 9R DSI's 6 SG A 2 57 SAI O1H +0.05 MRPC 9R DSI's SG A 2 92 SAI 01H +0.02 MRPC 9R DSI's i SG A 3 20 MAI O1H 40.01 MRPC 9R DSI's SG A SAI 02H -0.08 MRPC 9R DSI's i SG A 3 24 MAI O1H +0.01 MRPC 9R DSI's SG A 3 26 MAI O1H +0.02 MRPC 9R DSI's i SG A 3 32 SAI O1H +0.01 MRPC 9R DSI's SG A 3 85 SAI O1H +0.10 MRPC 9R DSI's SG A 4 9 ODI IO 01C -0.09 Bobbin SG A SAI O1H +0.12 MRPC 9R DSI's SG A 4 19 SAI O1H -0.05 MRPC 9R DSI's SG A 4 33 ODI 40 03H -0.12 Bobbin SG A 4 34 MAI O1H -0.06 MRPC BR DSI's SG A 4 35 ODI 63 01H -0.09 Bobbin SG A 4 37 MAI O1H +0.01 MRPC BR DSI's SG A 4 40 MAI O1H -0.05 MRPC 9R DSI's SG A SAI 03H -0.06 MRPC 9R DSI's f SG A 4 49 MAI O1H -0.14 MRPC 8R DSI's SG A 5 3 ODI 60 01H +0.00 Bobbin SG A 5 22 MAI O1H -0.01 MRPC 9R DSI's SG A 5 29 ODI 36 04H -0.06 Bobbin SG A ODI 63 O1H -0.09 Bobbin SG A 5 31 ODI 49 O1H -0.06 Bobbin SG A 5 32 SAI O1H +0.02 MRPC 9R DSI's SG A 5 42 SAI O1H -0.07 MRPC 9R DSI's SG A 5 51 MAI 01H -0.08' MRPC BR DSI's' SG A 5 54 MAI O1H +0.00 MRPC 8R DSI's SG A SAI 02H +0.14 MRPC 9R DSI's SG A 5 81 ODI 69 O1H '+0.03 Bobbin SG A 6 12 MAI O1H +0.00 MRPC 9R DSI's SG A 6 15 SAI 01H -0.11 MRPC 9R DSI's SG A C 18 MAI O1H +0.01 MRPC BR DSI's i SG A 6 21 ODI 77 O1H +0.00 Bobbin SG A 6 26 MAI O1H +0.09 MRPC 9R DSI's i SG A 6 28 MAI O1H +0.03 MRPC 9R DSI's SG A 6 48 SAI O1H -0.04 MRPC BR DSI's SG A 6 60 SAI O1H +0.04 MRPC-BR DSI's SG A 7 8 SAI O1H -0.07 MRPC 9R DSI's SG A 7 10 SAI 03H -0.10 MRPC 9R DSI's SG A 7 25 MAI O1H -0.10 MRPC 9R DSI's SG A 7 29 ODI 42 O1H -0.03 Bobbin + SG A 7 42 ODI 84 O1H +0.00 Bobbin SG A MAI O1H -0.09. MRPC BR DSI's SG A 7 44 SAI O1H -0.02 MRPC 9R DSI's SG A SAI 02H -0.02 MRPC 9R DSI's SG A 7 54 SAI O1H -0.07 MRPC 9R DSI's SG A SAI 02H -0.13 MRPC 9R DSI's SG A 8 4 SAI O1H +0.08 MRPC 9R DSI's SG A 8 5 SAI 03H +0.11 HRPC 8R DSI's SG A 8 24 ODI 31 O1H -0.09 Bobbin + SG A MAI O1H +0.07 MRPC BR DSI's SG A 8 34 ODI 79 TSH +0.29 Bobbin SG A 8 56 MAI O1H -0.01 MRPC 9R DSI's l SG A 8 62 MAI O1H -0.12 MRPC 9R DSI's' SG A 8 76 MAI O1H -0.01 MRPC BR DSI's t SG A 9 15 SAI O1H +0.03 MRPC 9R DSI's SG A 9 19 MAI O1H -0.01 MRPC BR DSI's SG A 9 31 SAI O1H -0.08 MRPC 9R DSI's l SG A 9 32 ODI 75 TSH +0.65 Bobbin SG A 9 77 MAI O1H -0.07 MRPC BR DSI's SG A 9 86 SAI O2H +0.00 MRPC BR DSI's-SG A 10 7 MAI O1H -0.20 MRPC 9R DSI's SG A 10 8 SAI O1H -0.13 MRPC 9R DSI's

i BWNS TUBAN II (Version 1.0) 10/22/1993 09:47440 Beaver Valley Unit 1 SG A { 4/93 RFO I Page 2 of 5 } STEAM GENERATOR A (RC-E-1A) 9R PLUGGED TUBES GEN ROW COL IND %TW LOCATION TEST TYPE SG A 10 10 SAI O1H +0.00 MRPC 9R DSI's SG A 10 15 SAI O1H +0.00 MRPC 8R DSI's SG A 10 26 MAI O1H -0.15 MRPC 8R DSI's SG A 10 33 NQI TSH +0.80 Bobbin i SG A ODI 11 TSH +0.80 Bobbin SG A SAI TSH +0.66 MRPC TSH Wextex SG A 10 37 ODI 53 TSH +1.14 Bobbin I SG A 10 40 ODI 43 TSH +0.76 Bobbin SG A 10 41 ODI 43 TSH +1.43 Bobbin SG A 10 44 ODI 52 TSH +0.87 Bobbin SG A 10 45 ODI 70 TSH +1.33 Bobbin SG A 10 52 SAI O1H -0.04 MRPC 9R DSI's SG A 10 66 SAI O1H -0.09 MRPC 9R DSI's SG A 11 7 ODI 48 O1H -0.12 Bobbin i SG A 11 17 SAI O1H +0.04 MRPC 9R DSI's SG A 11 18 SAI O1H -0.12 MRPC 9R DSI's SG A 11 19 MAI O1H -0.02 MRPC BR DSI's SG A 11 32 ODI 34 TSH +1.56 Bobbin SG A 11 33 ODI 64 TSH +1.46 Bobbin 7 SG A 11 37 ODI 65 TSH +2.04 Bobbin i SG A 11 39 ODI 57 TSH +1.26 Bobbin SG A 11 40 ODI-67 TSH +1.10 Bobbin SG A 11 46 ODI 45 TSH +1.60 Bobbin SG A 11 59 MAI O1H +0.01 MRPC BR DSI's t SG A 12 11'SAI 02H +0.09 MRPC 9R DSI's SG A 12 21 SAI O1H -0.13 MRPC BR DSI's SG A 12 26 SAI O1H -0.02 MRPC 9R DSI's SG A 12 32 ODI 50 TSH +1.13 Bobbin SG A 12 33 ODI 40 TSH +1.69 Bobbin SG A ODI 46 TSH +1.49 Bobbin SG A 12 44 ODI 45 TSH +2.81 Bobbin SG A 12 58 SAI O1H +0.01 MRPC BR DSI's SG A 12 69 SAI TSH -0.91 MRPC TSH Wextex SG A 13 22 SAI O1H -0.04 MRPC 9R DSI's SG A 13 24 MAI O1H -0.01 MRPC 9R DSI's-SG A 13 30 ODI 51 TSH +1.22 Bobbin SG A 13 35 ODI 56 TSH +2.14 Bobbin SG A 13 37.ODI 37 TSH +2.47 Bobbin SG A 13 41 ODI 77 TSH +1.76 Bobbin i SG A 13 75 SAI O1H -0.12 MRPC 9R DSI's LG A 14 6 MAI 01H -0.20 MRPC 9R DSI's SG A 14 14 ODI 49 01H +0.00 Bobbin SG A SAI O1H +0.00 MRPC BR DSI's SG A 14 32 ODI 35 O1H -0.12 Bobbin SG A ODI 57 TSH +1.24 Bobbin SG A MAI O1H +0.11 MRPC 8R DSI's. SG A SAI TSH +0.93 MRPC Special In SG A 14 33 ODI 9 TSH +1.41 Bobbin SG A SAI .TSH +1.45 MRPC Special In SG A SAI TSH +1.58 MRPC Special In SG A 14 34 ODI 34 TSH +1.77 Bobbin SG A 14. 36 NQI TSH +1.86 Bobbin SG A SAI TSH +1.91 MRPC TSH Wextex SG A 14 37 ODI 65 TSH +1.49 Bobbin SG A 14 38 ODI 53 TSH +1.35 Bobbin { SG A 14 39 ODI 50 TSH +1.40 Bobbin SG A 14 47 ODI 52 TSH +1.14 Bobbin SG A 14 48-ODI 74 TSH +0.91 Bobbin SG A 14 50 ODI 83 TSH +0.73 Bobbin SG A 14 56 MAI O1H -0.01 MRPC BR DSI's SG A 14 63 MAI O1H. -0.09 MRPC 9R DSI's j SG A 14 72 VOL TSH +0.70 MRPC TSH Wextex SG A 15 10 MAI O1H +0.14 MRPC 9R DSI's i SG A 15 24 SAI TSH -1.47 MRPC TSH Wextex SG A 15 35 NQI TSH +1.34 Bobbin i j

v BWNS TUBAN II (Version 1.0) 10/22/1993 09:47:40

                    • =*****

Beaver Valley Unit 1 i +ene************ SG A r 4/93 RFO Page 3 of 5 STEAM GENERATOR A (RC-E-1A) j 9R PLUGGED TUBES GEN ROW COL IND %TW LOCATION TEST TYPE SG A SAI TSH +1.53 MRPC Special In SG A 15 37 ODI 50 TSH +1.33 Bobbin l SG A 15 38 ODI 65 TSH +1.35 Bobbin- ~ SG A 15 42 NQI TSH +1.27 Bobbin SG A 'SAI TSH +0.78 MRPC TSH Wextex SG A 15 43 ODI 48 TSH +1.20 Bobbin { SG A 15 48 NQI TSH +0.62 Bobbin SG A 15 64 MAI O1H +0.09 MRPC BR DSI's SG A 16 5 SAI O1H +0.01 MRPC 9R DSI's SG A 16 12 SAI O1H +0.00 MRPC 9R DSI's SG A 16 13 SAI O1H -0.08 MRPC 9R DSI's SG A 16 22 SAI O1H +0.10 MRPC 9R DSI's l SG A 16 23 SAI O1H -0.11 MRPC 9R DSI's SG A 16 24 SAI O1H -0.12 MRPC 8R DSI's SG A 16 28 SAI O1H +0.00 MRPC 9R DSI's SG A 16 32 SAI O1H -0.17 MRPC 8R DSI's SG A 16 33 ODI 24 TSH +0.79 Bobbin. SG A 16 35 SAI O1H -0.15 MRPC 9R DSI's SG A 16 36 ODI 10 TSH +0.77 Bobbin SG A SAI TSH +0.56 MRPC Special In SG A 16 41 ODI 58 TSH +0.93 Bobbin SG A 16 42 ODI 62 TSH +1.12 Bobbin SG A 16 43 ODI 39 TSH +1.07 Bobbin SG A 16 45 SAI O1H -0.17 MRPC 9R DSI's SG A 16 55 SAI O1H -0.18 MRPC 9R DSI's SG A 16 85 SAI 03H -0.15 MRPC 9R DSI's SG A 17 37 NQI TSH +1.06 Bobbin SG A MAI TSH +0.83 MRPC TSH Wextex SG A 17 39 ODI 77 TSH +1.01 Bobbin 4 SG A 17 40 ODI 60 TSH +0.85 Bobbin SG A 17 41 ODI 58 TSH +0.80 Bobbin SG A 17 42 ODI 26 TSH +0.80 Bobbin SG A 17 43 ODI 54 TSH +0.87 Bobbin SG A 17 45 MAI O1H -0.07 MRPC 9R DSI's SG A 18 32 SAI O1H +0.06 MRPC 8R DSI's SG A 18 39 NQI TSH +0.67 Bobbin SG A SAI TSH +0.61 MRPC TSH Wextex-i SG A 19 25 SAI O1H -0.09 MRPC 9R DSI's SG A 19 30 SAI O1H -0.14 MRPC 9R.DSI's -[ SG A 19 35 SAI O1H +0.01 MRPC 9R DSI's SG A 19 37 SAI O1H +0.05 MRPC 9R DSI's l SG A 19 38 SAI O1H -0.07 MRPC 9R DSI's SG A 19 54 SAI O1H -0.19 MRPC 9R DSI's SG A 20 6 SAI 03H -0.02 MRPC 9R DSI's SG A 20 12 SAI 02H -0.04 MRPC 9R DSI's SG A SAI 03H. -0.01 MRPC 9R DSI's SG A-20 49 SAI O1H -0.07 MRPC 9R DSI's: SG A 20 52 SAI 01H' +0.08 MRPC 9R DSI's l SG A 20 54 SAI O1H -0.01 MRPC BR DSI's 4 SG A.20 61 SAI O1H -0.05 MRPC 9R DSI's SG A 20 63 SAI O1H -0.09 MRPC 9R DSI's SG A 20 66 SAI O1H -0.05 MRPC 9R DSI's SG A 21 78 SAI O1H -0.02 .MRPC BR DSI's SG A 21 80 SAI 02H +0.04 MRPC 9R DSI's' SG A 22 36 MAI O1H +0.00 MRPC 9R DSI's i SG A 22 44 SAI O1H -0.02 .MRPC 9R DSI's i SG A 22 45 ODI 24 O1H -0.06 Bobbin SG A SAI O1H +0.00 MRPC 8R DSI's SG A 22 47 SAI O1H +0.14 MRPC 9R DSI's SG A 22 53 SAI O1H -0.02 MRPC 9R DSI's SG A 22 55 SAI O1H -0.05 MRPC.9R DSI's t SG A 22 60 SAI O1H -0.04 MRPC BR DSI's -t SG A 23 40 MAI O1H +0.02 HRPC 9R DSI's [ SG A 23 42 SAI O1H -0.02 MRPC BR DSI's SG A 23 47 SAI O1H -0.02 MRPC 9R DSI's I

BWNS TUBAN II (Version 1.0) 10/22/1993 09:47:40-Beaver Valley Unit 1 SG A 4/93 RFO Page 4 of-5 STEAM GENERATOR A (RC-E-1A) 9R PLUGGED TUBES GEN ROW COL IND %TW LOCATION TEST TYPE SG A 23 50 ODI 16 Av3 +0.00 Bobbin SG A ODI 18 AV3 +16.62 Bobbin SG A SAI O1H -0.15 MRPC 9R DSI's. SG A 24 60 SAI O1H +0.10 MRPC 9R DSI's-SG A 25 14 MAI 02H +0.03 MRPC 8R DSI's SG A 25 48 SAI O1H -0.09' MRPC 9R DSI's SG A 26 10 ODI 45 Olc -0.09 Bobbin SG A 26 11 MAI O1H -0.04 MRPC 9R DSI's SG A 26 26 ODI 28 AV4 +0.00 Bobbin SG A SAI O1H -0.04 MRPC 9R DSI's SG A 26 48 SAI O1H -0.01 MRPC 9R DSI's SG A 26 51 SAI O1H -0.05 MRPC 9R DSI's SG A 26 55 SAI O1H -0.04 MRPC BR DSI's SG A 27 19 SAI O1H -0.07 MRPC 8R DSI's SG A 27 53 SAI O1H -0.10 MRPC BR DSI's SG A 27 66 SAI O1H +0.04 MRPC 9R DSI's SG A 27 75 SAI 04H -0.05 -MRPC 9R DSI's SG A 28 17 SAI O1H +0.02 MRPC SR DSI's SG A 28 23 ODI 29 03H -0.12 Bobbin SG A MAI 04H -0.06 MRPC 9R DSI's SG A 28 41 SAI 01H -0.01 MRPC 8R DSI's SG A 28 63 SAI O1H -0.08 MRPC 9R DSI's SG A 29 21 MAI O1H +0.00 MRPC BR DSI's SG A 29 23 SAI O1H -0.02 MRPC 9R DSI's SG A 29 44 MAI O1H -0.03 MRPC BR DSI's SG A -29 51 SAI O1H -0.03 MRPC 9R DSI's SG A 30 24 SAI 03H -0.03 MRPC 9R DSI's SG A 30 39 VOL TSH -0.91 MRPC TSH Wextex SG A 30 45 SAI 02H -0.08 MRPC 9R DSI's SG A 31 20 MAI O1H -0.01 MRPC 8R DSI's SG A 31 23 ODI 36 TSH +32.50 . Bobbin SG A ODI 53 TSH +32.97 Bobbin SG A 31 56 SAI O1H -0.02 MRPC 9R DSI's SG A 32 32 ODI 27 AV4 +0.00 Bobbin +' SG A ODI 34 AV2 +0.00 Bobbin SG A ODI 35 AV3 +0.00 Bobbin SG A ODI 39 AV1 -0.09 Bobbin SG A MAI O1H +0.01 MRPC BR DSI's-SG A 32 40 SAI' O1H -0.07 MRPC 9R DSI's SG A 32 45 SAI O1H +0.00 MRPC BR DSI's SG A 32 51 SAI O1H --0.06 MRPC 9R DSI's SG A 33 33 SAI O1H -0.07 MRPC 9R DSI's SG A 33 56 ODI 31 AV1 +0.00 Bobbin 'SG A ODI 31 AV4 +0.00 Bobbin- 'f SG A ODI 38 AV2 +0.00 Bobbin-SG A ODI 40 AV3 +0.00 ' Bobbin -i SG A. 34 23 ODI 10 05H +0.15 Bobbin ~ SG A SAI O1H -0.04 'HRPC 9R DSI's SG A 34 30 SAI O1H -0.10 hRPC 9R DSI's' SG A.34 31 MAI O1H -0.04 MRPC 8R DSI's SG A 34 60 SAI O1H -0.06 MRPC 9R DSI's SG A 36 24'SAI 02H -0.09 MRPC 9R DSI's SG A 36 36 SAI O1H +0.02 MRPC BR DSI's l SG A 36 61 ODI 18 AV2 +0.00 Bobbin f SG A MAI 02H +0.09 MRPC 8R DSI's SG A 37 31 SAI O1H +0.00 'MRPC 9R DSI's-SG A 37-63 SAI 02H -0.04 MRPC BR DSI's SG A 37 67 SAI 02H +0.00 MRPC BR DSI's SG A 38 36 SAI 03H +0.07 MRPC 9R DSI's SG A 38 53 MAI 02H -0.10 MRPC BR DSI's i SG A 38 55 MAI 02H -0.16 MRPC 8R DSI's i SG A 38 68 MAI-02H -0.06 MRPC BR DSI's SG A 38 74 MAI O1H +0.00 MRPC BR DSI's SG A. 39 39 MAI 02H +0.00 MRPC BR DSI's SG A 39 51 MAI 02H -0.05 MRPC 8R DSI's i l

i BWNS TUBAN II (Version 2.0) 10/22/1993 09:47:40 Beaver Valley Unit 1 SG A 4/93 RFO Page 5 of 5 STEAM GENERATOR A (RC-E-1A) 9R PLUGGED TUBES GEN ROW COL IND %TW LOCATION TEST TYPE + SG A 40 34 SAI OlH -0.06 MRPC 9R DSI's Total Indications Found = 261 Total Tubes Found = 221 Total Tubes in Input File = 221 1 + 6 h a + 9 l I f i l a

ATTACH WENT 2 1 i CSIT #1 9TH REFLELING OLTAGE t i STEAM GENERATOR "B" (<RC-E-1B; F 1 l a

[ BWNS TUBAN II (Version.1.0) '10/22/1993 14:16:47 Beaver Valley Unit 1 ~ SG B 4/93 RFO r t i Page 1 of 13 l STEAM GENERATOR B (RC-E-1B) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 1 1 DSI 02H -0.03 Bobbin SG B SAI 02H +0.09 MRPC 9R DSI's ? SG B 1 3 DSI O1H -0.06 Bobbin t SG B SAI 07H +10.03 MRPC U-Bend SG B MAI O1H +0.03 MRPC 9R DSI's SG B 1 4 DSI O1H -0.06 Bobbin .I SG B DSI 02H -0.03 Bobbin SG B 1 5 DSI O1H +0.00 Bobbin SG B 1 7 DSI O1H -0.08 Bobbin SG B DSI 03H -0.06 Bobbin i SG B SAI 07H +10.15 KRPC U-Bend .i SG B 1 11 SAI 07H +9.91 MRPC U-Bend i SG B 1 13 DSI O1H -0.08 Bobbin i SG B DSI 02H -0.06 Bobbin SG B 1 14 DSI 02H -0.17 Bobbin SG B DSI 04H -0.11 . Bobbin SG B 1 15 DSI O1H -0.06 Bobbin SG B DSI 02H -0.08 Bobbin l SG B MAI 02H +0.00 MRPC 9R DSI's SG B SAI O1H +0.11 HRPC 9R DSI's SG B 1 16 DSI O1H +0.00 Bobbin i SG B DSI 02H -0.08 Bobbin SG B SAI O1H +0.02 MRPC 9R DSI's SG B 1 18 DSI O1H -0.14 Bobbin SG B DSI 04H -0.14 Bobbin SG B SAI 07H +4.51 MRPC U-Bend SG B 1 20 DSI O1H -0.14 Bobbin SG B DSI O2H -0.17 Bobbin SG B SAI 07H +10.14 MRPC U-Bend SG B SAI O1H -0.02 MRPC BR DSI's SG B 1 21 DSI O1H -0.11 Bobbin i SG B DSI 02H -0.11 Bobbin SG B DSI 04H -0.06 Bobbin SG B SAI O1H +0.05 MRPC 9R DSI's SG B 1 23 DSI O1H -0.14 Bobbin SG B 1 25 ODI 17 02H -0.11 Bobbin SG B SAI 07H +10.41 MRPC U-Bend SG B 1 26 DSI O1H -0.20 Bobbin.. SG B SAI 07H +10.27 MRPC U-Bend SG B 1 30 SAI 07H +10.01 MRPC U-Bend I SG B 1 35 SAI 07H +10.45 MRPC U-Bend SG B 1 37 SAI 07H +10.20 MRPC U-Bend SG B 1 40 PVN 04C +16.52 Bobbin SG B 1 41 SAI 07H +11.14 MRPC U-Bend l SG B 1 42 SAI 07H +10.24 MRPC U-Bend ~ SG B 1 45 ODI 23 O1H -0.06 Bobbin SG B-1 49 ODI 26 02H +0.03-Bobbin SG B 1 53 SAI 07H +9.60 MRPC U-Bend i SG B 1 56 SAI 07H +3.45 MRPC U-Bend SG B SAI 07H +3.97 MRPC U-Bend j SG B 1 59 SAI 07H +3.49 MRPC U-Bend SG B 1 61 ODI 22 O1H -0.03 Bobbin .) SG'B SAI 07H +3.56 MRPC U-Bend j SG B 1 62 ODI 28 O1H +0.00 Bobbin i SG B 1 65 DSI 04H -0.08 Bobbin SG B ODI 38 O1H +0.03 Bobbin SG B 1 66 DSI 02H -0.06 Bobbin SG B 1 67 DSI 02H -0.08 Bobbin SG B 1 68 DSI 02H -0.05 Bobbin SG B 1 70 DNT 06H +9.24 Bobbin SG B DSI 02H -0.11 Bobbin SG B 1 73 SAI 07H +3.72 MRPC U-Bend SG B 1 74 MAI 07H +3.74 MRPC U-Bend SG B 1 80 SAI 07H +10.14 MRPC U-Bend SG B 1 92 ODI 21.TSH +17.61 Bobbin i

BWNS TUBAN II (Version 1.0) 10/22/1993 14:16:47 Beaver Valley Unit 1

  • e**************

SG-B 4/93 RFO Page 2 of 13 STEAM GENERATOR B (RC-E-1B) 9R INDICATIONS GEN ROW COL IND %TW LOCATION . TEST TYPE SG B 1 93 ODI 30 TSH +17.78 . Bobbin SG B 2 5 DSI 02H -0.06 Bobbin SG B '2 8 DSI O1H -0.06 Bobbin SG B SAI O1H +0.09 MRPC 9R DSI's SG B 2 9 DSI O1H -0.14 Bobbin SG B DSI O2H -0.08 Bobbin SG B SAI O1H +0.04 MRPC 9R~DSI's SG B 2 10 DSI O1H -0.11 Bobbin SG B DSI 02H -0.14 Bobbin SG B SAI 07C +4.46 MRPC U-Bend SG B 2 13 DSI O1H -0.06 Bobbin SG B DSI 03H +0.00 Bobbin SG B 2 19 ODI 21 O1H -0.19 Bobbin SG B 2 21 NQI TSH +0.31 Bobbin SG B 2 22 DSI O1H -0.11 Bobbin SG B SAI O1H +0.01 MRPC 9R DSI's SG B 2 23 DSI O1H -0.03 Bobbin SG B 2 24 DSI 02H -0.14 Bobbin SG B 2 28 DSI 02H -0.17 Bobbin SG B 2 30 DSI 02H -0.08 Bobbin SG B 2 31 DSI O1H -0.08 Bobbin SG B 2 34 DSI O1H -0.11 Bobbin SG B DSI 02H +0.00 Bobbin SG B ODI 20 04H +0.00 Bobbin SG B SAI O1H +0.00 MRPC 9R DSI's SG B SAI 02H +0.02 MRPC 9R DSI's SG B 2 36 DSI 02H -0.05 Bobbin SG B 2 38 DSI 02H -0.05 Bobbin SG B SAI 02H +0.03 MRPC BR DSI's SG B 2 40 DSI O1H -0.08 Bobbin SG B 2 41 ODI 18 O1H -0.08 Bobbin SG B 2 42 DSI O1H -0.03 Bobbin SG B 2 46 DSI O1H -0.08 Bobbin SG B 2 47 DSI 02H +0.00 Bobbin SG B 2 60 DSI O1H -0.08 Bobbin SG B SAI O1H +0.17 MRPC 9R DSI's SG B 2 65 DSI 02H -0.08 Bobbin SG B 2 66 DSI 02H -0.05 Bobbin SG B 2 69 DSI 02H -0.11. Bobbin SG B 2 71 DSI O1H -0.05 Bobbin SG B DSI 02H -0.05 Bobbin SG B SAI 02H +0.00 MRPC BR DSI's SG B 2 72 DSI O1H -0.08 Bobbin. SG B DSI 03H +0.00 Bobbin SG B 2 73 DSI O1H -0.08 Bobbin SG B DSI 02H -0.03 Bobbin. SG B 2 74 DSI O2H +0.00 Bobbin SG B 2 79 DSI C2H -0.11 Bobbin SG B 2 81 DSI 03H -0.03 Bobbin SG B DSI 04H -0.03 Bobbin-SG B 2 . 83 DSI 03H -0.03 Bobbin SG B 2 85.DSI 03H -0.05 Bobbin SG B 2 86 DSI 03H -0.05 Bobbin. SG B DSI 04H -0.05 Bobbin SG B 2 90 ODI 25 04H -0.03-Bobbin-SG B 3 1 DSI O1H -0.08 Bobbin SG B DSI O1H +0.05 Bobbin SG B 3 2 DSI O1H -0.08 Bobbin SG B DSI O1H +0.03 Bobbin SG B DSI 02H +0.05 Bobbin SG B SAI O1H -0.05 MRPC 9R DSI's SG B 3 6 DSI O1H +0.08 Bobbin SG B 3 7 DSI O1H +0.03 Bobbin SG B 3 8 DSI 02H -0.11 Bobbin SG B DSI 04H -0.11 Bobbin

i BWNS TUBAN II (Version 1.0) 10/22/1993 14 16:47 Beaver Valley Unit 1 SG B 4/93 RFO Page 3 of 13 STEAH GENERATOR B (RC-E-1B) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 3 9 DSI O1H -0.11 Bobbin SG B 3 12 DSI O1H -0.06 Bobbin SG B 3 15 DSI O1H -0.06 Bobbin i SG B 3 18 DSI O1H -0.06 Bobbin SG B 3 21 DSI O1H -0.11 Bobbin SG B SAI O1H +0.00 MRPC 9R DSI's SG B 3 22 DSI O1H -0.14 Bobbin SG B 3 24 DSI O1H -0.06 Bobbin SG B 3 27 DSI O1H -0.14 Bobbin SG B SAI O1H -0.08 MRPC 9R DSI's SG B 3 35 DSI O1H +0.00 Bobbin SG B 3 43'DSI O1H -0.03 Bobbin SG B 3 46 DNT TSH -0.14 Bobbin SG B 3 47 DNT TSH -0.25 Bobbin SG B 3 49 DSI 01H +0.08 Bobbin SG B DSI 02H -0.06 Bobbin + SG B 3 53 DSI O1H -0.03 Bobbin SG B DSI 02H +0.06 Bobbin i SG B 3 55 DSI O1H -0.11 Bobbin SG B SAI 01H -0.06 MRPC 9R DSI's + SG B 3 58 DSI O1H -0.06 Bobbin SG B 3 61 ODI 17 O1H +0.11 Bobbin SO 8 3 63 DSI 03H -0.03 Bobbin SG B 3 64 DSI 03H -0.06 Bobbin SG B 3 68 DSI 03H -0.14 Bobbin SG B SAI 03H +0.04 MRPC 9R DSI's SG B 3 70 ODI 26 01H +0.08 Bobbin SG B 3 75 DSI 03H -0.03 Bobbin SG B MAI 03H -0.12 MRPC BR DSI's SG B 3 92 DSI 02H +0.03 Bobbin SG B SAI 02H -0.12 MRPC 8R DSI's SG B 4 5 DSI 02H +0.00 Bobbin SG B SAI 02H +0.01 MRPC 9R DSI's SG B 4 6 DSI O1H +0.03 Bobbin SG B DSI 02H +0.03 Bobbin SG B DSI 03H +0.05 Bobbin SG B SAI 02H +0.00 MRPC BR DSI's SG B 4 8 DSI 02H -0.03 Bobbin i SG B DSI 03H +0.00 Bobbin SG B 4 10 OD7 7 O1H +0.16 Bobbin i SG B 4 13 DSI O1H -0.03 Bobbin SG B SAI O1H +0.10 MRPC 9R DSI's + SG B 4 14 DSI O1H -0.06 Bobbin SG B DSI 02H -0.11 Bobbin SG B SAI 02H -0.04 MRPC 9R DSI's~ SG B 4 15 DSI O1H -0.06 Bobbin i SG B 4 29 DSI O1H -0.08 Bobbin SG B SAI O1H -0.07 MRPC BR DSI's SG B 4 31 DSI O1H +0.00 Bobbin I SG B SAI O1H -0.04 MRPC 9R DSI's SG B 4 35 DSI 02H +0.08 Bobbin l SG B 4 49 DSI O1H -0.06 Bobbin SG B 4 57 DSI O1H +0.00 Bobbin SG B 4 58 DSI O1H +0.04 Bobbin ? I SG B SAI O1H -0.03 MRPC 9R DSI's SG B 4 60 DSI O1H +0.03 Bobbin SG B SAI O1H +0.01 MRPC 9R DSI's SG B 4 65 DSI 02H +0.03 Bobbin SG B 4 82 DSI O1H +0.06 Bobbin SG B 4 84 DSI O1H +0.03 Bobbin SG B DSI 02H +0.00 Bobbin SG B MAI 02H +0.05 MRPC BR DSI's SG B 4 85 DSI 04H +0.03 Bobbin SG B 5 3 ODI 37 04H +0.14 Bobbin SG B 5 12 DSI O1H +0.00 Bobbin

(Version 1.0) ley Unit 1 10/22/1993 14:16:47 BWNS TUBAN II Beaver Val SG B 4/93 RFO Page 4 of 13 STEAM GENERATOR B (RC-E-1B) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B DSI O2H +0.03 Bobbin SG B MAI O2H -0.01 MRPC 9R DSI's SG B 5 13 DSI 02H +0.09 Bobbin SG B DSI 04H -0.15 Bobbin SG B 5 14 ODI 23 O1H -0.03 Bobbin SG B 5 18 DSI 02H +0.03 Bobbin SG B 5 35 DSI 02H -0.03 Bobbin SG B SAI 02H +0.02 MRPC 9R DSI's SG B 5 39 DSI O2H +0.11 Bobbin SG B 5 40 DSI O1H +0.14 Bobbin SG B 5 41 DSI O1H +0.06 Bobbin SG B SAI O1H +0.00 MRPC BR DSI's SG B 5 47 DSI O1H -0.12 Bobbin SG B SAI O1H -0.06 MRPC 9R DSI's SG B 5 54 DSI O1H +0.09 Bobbin SG B DSI 02H -0.03 Bobbin SG B 5 57 DSI O1H +0.06 Bobbin SG B 5 79 DSI 02H +0.00 Bobbin SG B SAI 02H +0.04 MRPC 9R DSI's SG B 5 93 ODI 9 Olc +0.00 Bobbin SG B 5 94 ODI 23 02C -0.12 Bobbin SG B 6 1 DSI 01H +0.08 Bobbin SG B 6 5 DSI O1H -0.05 Bobbin SG B SAI O1H -0.09 MRPC 8R DSI's SG B 6 9 DSI O1H -0.05 Bobbin SG B MAI O1H -0.08 MRPC 9R DSI's SG B 6 11 DSI O1H +0.09 Bobbin SG B DSI 02H +0.06 Bobbin SG B 6 14 DSI O1H -0.06 Bobbin SG B 6 19 DSI O1H +0.00 Bobbin SG B 6 23 DSI O1H +0.03 Bobbin SG B DSI 03H +0.09 Bobbin Sr, B SAI 03H -0.02-MRPC 9R DSI's St B 6 24 DSI O1H +0.09 Bobbin SG B ODI 26 TSH +1.38 Bobbin SG B 6 26 DSI O1H -0.06 Bobbin t SG B 6 28.DSI O1H +0.06 Bobbin SG B SAI O1H +0.03 MRPC 8R DSI's SG B 6 30 DSI O1H -0.09 Bobbin i SG B 6 31 DSI O1H +0.00 Bobbin SG B 6 36 DSI O1H -0.06 Bobbin SG B DSI O2H +0.03 Bobbin SG B DSI 03H +0.00 Bobbin SG B SAI O1H -0.10 MRPC 9R DSI's SG B SAI 02H -0.08 MRPC 9R DSI's SG B SAI 03H -0.04 MRPC 8R DSI's SG B 6 40 SAI O1H +0.03 MRPC 8R DSI's v SG B 6 56 DSI 91H +0.12 Bobbin SG B 6 78 DSI O1H +0.20 Bobbin SG B DSI 03H +0.03 Bobbin SG B SAI O1H +0.04 MRPC 9R DSI's SG B 6 83 ODI 35 01H +0.12 Bobbin 1 SG B 6 93 ODI 40 02C -0.15 Bobbin SG B 7 1 ODI-10 02C +0.06 Bobbin I SG B 7 6 DSI O1H +0.11 Bobbin SG B-MAI O1H +0.03 MRPC 8R DSI's SG B 7 8 DSI O2H +0.05 Bobbin SG B SAI O2H +0.01 MRPC 9R DSI's-SG B 7 9 DSI O1H +0.08 Bobbin SG B MAI O1H -0.12 MRPC 9R DSI's SG B 7 10 DSI O1H +0.05 Bobbin SG B 7 12 DSI O1H +0.06 Bobbin SG B 7 20 DSI O1H -0.06 Bobbin SG B DSI 03H +0.00 Bobbin SG B MAI O1H +0.01 MRPC 9R DSI's -l I

BWNS'TUBAN'II (Version 1.0) 10/22/1993 14:16:47

                          • 5**

l Beaver Valley Unit 1

    • a*************

SG B i 4/93 RFO Page 5 of 13 STEAH GENERATOR B (RC-E-1B) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B SAI 03H +0.00 MRPC 9R DSI's i SG B 7 21 DSI O1H +0.03 Bobbin SG B SAI O1H +0.00 MRPC 9R DSI's i SG B 7 22 DSI O1H +0.00 Bobbin SG B DSI O2H +0.00 Bobbin SG B SAI O1H +0.00 MRPC BR DSI's i SG B 7 32 ODI 36 01H -0.09 Bobbin i SG B 7 58 DSI O1H +0.09 Bobbin SG B SAI O1H +0.03 MRPC 9R DSI's SG B 7 92 ODI 28 Olc -0.06 Bobbin SG B 7 94 ODI 29 Olc -0.03 Bobbin i SG B 8 2 ODI 20 02C +0.00 Bobbin SG B 8 13 DSI O1H +0.00 Bobbin SG B SAI 01H -0.09 HRPC 9R DSI's SG B 8 18 DSI OIH +0.09 Bobbin l SG B SAI O1H +0.00 MRPC 9R DSI's j SG B 8 31 ODI 27 TSH +1.20 Bobbin t SG B 8 37 DSI O1H +0.06 Bobbin i SG B 8 45 DSI O1H -0.03 Bobbin l SG B 8 47 DSI O1H +0.03 Bobbin SG B SAI O1H -0.04 MRPC 9R DSI's SG B 8 50 DSI O1H -0.03 Bobbin SG B SAI O1H +0.00 MRPC 9R DSI's r SG B 8 69 PVN TSH -0.01 MRPC TSH Wextex SG B 8 92 ODI 34 Olc -0.17 Bobbin SG B 9 5 DSI 03H +0.00 Bobbin SG B 9 8 DSI O1H +0.08 Bobbin SG B DSI 02H +0.05 Bobbin i SG B 9 9 ODI 19 O1H +0.00 Bobbin i SG B 9 10 DSI O1H +0.03 Bobbin SG B SAI 01H +0.00 MRPC 9R DSI's SG B 9 13 DSI O1H -0.03 Bobbin SG B DSI 02H -0.09 Bobbin SG B SAI O1H -0.04 MRPC 8R DSI's SG B 9 19 DSI O1H +0.06 Bobbin SG B SAI O1H +0.00 MRPC 9R DSI's SG B 9 22 DSI O1H -0.03 Bobbin [ SG B SAI O1H -0.06 MRPC 9R DSI's SG B 9 29 ODI 42 TSH +1.17 Bobbin i i SG B 9 31 DSI O1H +0.00 Bobbin SG B SAI O1H +0.00 MRPC 8R DSI's SG B 9 32 ODI 47 TSH +1.47 Bobbin SG B 9 34 ODI 60 TSH +1.18 Bobbin SG B 9 36 NQI TSH +0.96 Bobbin SG B ODI 32 02H -0.03 Bobbin' SG B VOL TSH +0.75 MRPC TSH Wextex SG B 9 41 DSI O1H +0.03 Bobbin i SG B SAI O1H +0.01 MRPC 9R DSI's i SG B 9 48 DSI O1H -0.09 Bobbin i SG B DSI 02H +0.12' Bobbin l SG B 9 59 DSI O1H +0.03 Bobbin i SG B SAI O1H +0.02 MRPC BR DSI's j SG B 9 70 DSI O1H +0.12 Bobbin SG B ODI 16 03H +0.00 Bobbin SG B 9 72 DSI O1H +0.03 Bobbin SG B SAI O1H +0.01 MRPC BR DSI's SG B 9 73 DSI 02H +0.00 Bobbin SG B 9 82 DSI O1H +0.00 Bobbin SG B SAI O1H -0.07 MRPC 9R DSI's SG B 9 83 DSI O1H +0.00 Bobbin SG B SAI O1H -0.08 MRPC 8I DSI's E SG B 9 93 ODI 25 02C +0.03 Bobbin ? 2" B s 2 ODI 8 02C -0.11 Bobbin 3G B 10 4 DSI O1H +0.05 Bobbin E7 B SAI 01H +0.00 MRPC 9R DSI's i

's BWNS'TUBAN II (Version 1.0) 10/22/1993 14:16:47 Beaver Valley Unit 1 SG B 1 l 4/93 RFO

I Page 6 of 13 STEAH GENERATOR B (RC-E-1B) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 10 14 DSI 02H

-0.03 Bobbin i SG B 10 39 ODI 32 01H +0.03 Bobbin SG B 10 72 DSI O1H +0.15 Bobbin SG B 10 73 DSI O1H +0.06 Bobbin SG B 10 92 ODI 33 Olc -0.17 Bobbin SG B 11 27 DSI O1H +0.00 Bobbin SG B 11 41 ODI 42 TSH +1.41 Bobbin i SG B VOL TSH +1.34 MRPC TSH Wextex SG B 11 47 NQI TSH +0.80 Bobbin I SG B 12 7 DSI O1H -0.08 Bobbin l SG B DSI 02H +0.03 Bobbin SG B DSI 03H +0.08 Bobbin SG B MAI O1H +0.00 MRPC 9R DSI's t SG B MAI 03H -0.02 MRPC 9R DSI's j SG B SAI 02H +0.00 MRPC 9R DSI's SG B 12 11 DSI O1H +0.09 Bobbin j SG B MAI O1H -0.02 MRPC 9R DSI's SG B 12 15 ODI 62 O1H +0.12 Bobbin i SG B 12 19 DSI 02H -0.03 Bobbin SG B SAI 02H +0.04 MRPC 9R DSI's SG B 12 22 DSI O1H -0.03 Bobbin [ SG B DSI 02H -0.03 Bobbin i SG B MAI O1H -0.14 MRPC 8R DSI's SG B SAI 02H -0.01 MRPC 9R DSI's l SG B ~12 32 DSI 02H +0.03 Bobbin SG B SAI 02H +0.01 MRPC 9R DSI*s -l SG B 12 34 ODI 57 TSH +2.40 Bobbin SG B 12 37 SAI O1H -0.02 MRPC 8R DSI's j SG B 12 40 DSI O1H +0.03 Bobbin SG B SAI O1H +0.05 MRPC BR DSI's SG B 12 50 DSI O1H +0.06 Bobbin SG B 12 51 ODI 28 O1H +0.00 Bobbin t SG B.22 80 DSI O1H +0.06 Bobbin SG B SAI O1H +0.11 MRPC 9R DSI's i SG B 12 92 ODI 13 Olc -0.06 Bobbin i SG B 13 3 DSI O1H +0.05 Bobbin i SG B SAI O1H +0.03 MRPC 9R DSI's t SG B 13 4 ODI .26 02C -0.03 Bobbin i SG B 13 22 DSI O1H -0.06 Bobbin SG B SAI O1H -0.11 MRPC 9R DSI's SG B 13 25 NQI TSH +0.50 Bobbin I SG B 13 26 DSI O1H +0.03 Bobbin SG B ODI 62 TSH +0.57 Bobbin [ SG B SAI O1H +0.01 MRPC BR DSI's i SG B 13 32 DSI O1H -0.15 Bobbin SG B 13 33 DSI O1H -0.09 Bobbin I SG B DSI 02H -0.03 Bobbin I SG B ODI 84 TSH +2.47 Bobbin SG B SAI 02H +0.02 MRPC 9R'DSI's o SG B. 13 35 ODI 44 TSH- +2.71 Bobbin i SG B 13 36 ODI 25 TSH +2.65 Bobbin SG B 13 49 DSI O1H: +0.03 Bobbin SG B 13 53 DSI O1H +0.12 Bobbin i SG B SAI O1H +0.00 MRPC 9R DSI's l SG B 13 69 DSI O1H +0.03 Bobbin SG B . SAI 01H +0.01 MRPC 9R DSI's i SG B 13 73 DSI O1H +0.00 Bobbin SG B MAI O1H -0.04 MRPC BR DSI*s SG B 13 78 DSI 01H' +0.09 Bobbin SG B 13 80 PVN O1H +0.00 MRPC BR DSI's 'I SG B 13 90 ODI 28'02C +0.14 Bobbin SG B 13 91 ODI 29 Olc -0.11 Bobbin SG B 14 4 ODI 25 02C -0.03 Bobbin l SG B 14 13 DSI O2H +0.00 Bobbin-i SG B SAI 02H -0.01 MRPC 9R DSI's si y s.

I l I BWNS TUBAN II (Version 1.0) 10/22/1993 14:16:47 Beaver Valley Unit 1 SG B t 4/93 RFO _l e **............ Page 7 of 13 -l STEAH CENERATOR B (RC-E-1B) l 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE 4't SG B 14 28 DSI O1H +0.00 Bobbin l SG B SAI O1H +0.00 MRPC 9R DSI's SG B 14 41 DSI O1H +0.03 Bobbin i SG B MAI O1H +0.00 MRPC 9R DSI's i SG-B 14 71 DSI O1H +0.09 Bobbin i SG B 14 77 DSI 01H -0.03 Bobbin l SG B 14 79 DSI O1H +0.03 Bobbin f SG B 14 82 DSI O1H +0.00 Bobbin SG B 15 3 ODI 34 Olc -0.05 Bobbin i SG B 15 5 DSI O1H +0.00 Bobbin SG B 15 6 ODI 35 Olc -0.11 Bobbin SG B 15 10 DSI 02H -0.03 Bobbin SG B SAI 02H -0.02 MRPC 9R DSI's ( SG B 15 11 DSI O1H -0.06 Bobbin SG B SAI O1H -0.07 MRPC 9R DSI's [ SG B 15 12 DSI O1H +0.15 Bobbin i SG B DSI 02H -0.06 Bobbin i SG B SAI O1H +0.07 MRPC 9R DSI's SG B SAI O2H +0.06 MRPC 9R DSI's SG B 15 30 DSI O1H +0.06 Bobbin I SG B ODI 54 TSH +1.43 Bobbin SG B 15 31 ODI 47 TSH +1.23 Bobbin SG B 15 32 ODI 65 TSH +1.27 Bobbin SG B 15 35 ODI 36 TSH +2.37 Bobbin SG B 15 37 DSI O1H +0.06 Bobbin i SG B SAI O1H +0.02 MRPC 9R DSI's SG B 15 39 DSI O1H +0.09 Bobbin SG B SAI O1H +0.01 MRPC 9R DSI's SG B 15 49 DSI O1H -0.03 Bobbin SG B 15 51 VOL TSH +0.95 MRPC TSH Wextex SG B 15 52 DSI O2H +0.06 Bobbin j SG B 15 58 DSI O1H +0.03 Bobbin t SG B 15 91 ODI 20 Olc +0.06 Bobbin SG B 16 5 ODI 35 Olc -0.06 Bobbin SG B 16 6 ODI 27 OIC -0.08 Bobbin SG B 16 7 DSI O1H +0.06 Bobbin SG B 16 20 DSI 02H +0.00 Bobbin i SG B 16 24 DSI O1H +0.09 Bobbin l SG B 16 25 PVN TSH +3.67 Bobbin SG B 16 30 DSI O1H . +0.00 Bobbin SG B ODI 78 TSH +0.70 Bobbin SG B 16 35 ODI 78 TSH +0.89 Bobbin SG B 16 41 DSI O1H +0.06 Bobbin i SG B SAI O1H +0.00 MRPC 9R DSI's i SG B 16 42 DSI O1H +0.00 Bobbin i SG B 16 57 DSI 03H +0.09 Bobbin SG B 16 60 DSI O1H +0.09 Bobbin SG B 16 78 DSI O1H +0.03 Bobbin i SG B 17 4 ODI 28 01C -0.14 Bobbin SG B 17-6 DSI O1H +0.03 Bobbin SG B 17 13 DSI 02H +0.03 Bobbin SG B SAI O2H +0.01 MRPC 9R DSI's. SG B 17 15 DSI O1H +0.00 Bobbin i SG B SAI O1H -0.02 MRPC 9R DSI's SG B 17 16 DSI DIH +0.1B Bobbin-SG B ODI 28 02H +0.15 Bobbin l SG B 17 23 DSI O1H +0.00 Bobbin SG B SAI O1H +0.00 MRPC 9R DSI's ' 0.00 Bobbin i SG B 17 24 DSI O1H + SG B DSI 02H +0.03 Bobbin SG B SAI O1H -0.09 MRPC 9R DSI's SG B 17 30 DSI O1H +0.06 Bobbin i SG B 17 33 ODI 28 03H +0.06 Bobbin t SG B 17 35 DSI O1H +0.12 Bobbin i SG B SAI O1H +0.01 MRPC 9R DSI's I i 7

I I een......ee...e-BWNS TUBAN II (Version.1.0) 10/22/1993 14:16:47 Beaver Valley Unit 1 SG B 4/93 RFO Page 8 of 13 i STEAM GENERATOR B (RC-E-1B) [ ~ 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 17 37 DSI O1H -0.03 Bobbin -i SG B 17 48 DSI 02H +0.00 Bobbin i SG B SAI 02H +0.02 MRPC 9R DSI's i SG B 17 56 DSI O1H +0.06 Bobbin' SG B DSI 02H +0.00 Bobbin SG B MAI O1H +0.07 MRPC 9R DSI's SG B 17 64 DSI O1H +0.06 Bobbin SG B 17 67 DSI 02H -0.03 Bobbin SG B 17 70 DSI 03H -0.06 Bobbin j SG B 17 71 DSI O1H +0.03 Bobbin ) SG B 18 8 ODI 16 O1H +0.03 Bobbin SG B 18 10 ODI 26 03H +0.06 Bobbin i SG B 18 12 DSI O1H +0.06 Bobbin i SG B SAI O1H -0.03 MRPC 9R DSI's SG B 18 23 DSI O1H +0.09 Bobbin SG B 18 26 DSI O1H +0.00 Bobbin SG B SAI O1H +0.01 MRPC 9R DSI's SG B 18 30 ODI 19 AV3 +0.00 ' Bobbin i SG B 'ODI 27 AV2 +0.00 -Bobbin a SG B 18 32 DSI O1H +0.12 Bobbin SG B ODI 64 TSH +0.49 Bobbin e l SG B 18 40 ODI 41 TSH +0.76 Bobbin SG B 18 50 DSI O1H +0.16 Bobbin SG B 18 53 DSI O1H +0.21 Bobbin: i SG B 18-54 DSI O1H +0.11 Bobbin 1 SG B SAI O1H -0.02 MRPC 9R DSI's i SG B 18 59 DSI O1H +0.15 Bobbin [ a SG B PVN 01H +0.00 MRPC 9R DSI's 6 SG B 18 61 DSI O1H +0.12 Bobbin i 3 SG B 18 65 ODI 27 AVI +0.00. Bobbin 1 SG B 18 76 DSI O1H +0.00 Bobbin SG B SAI O1H -0.05 MRPC 9R DSI's SG B 18 89 ODI 22 02C -0.09 Bobbin 'l SG B 19 10 DSI O1H +0.14 Bobbin SG B SAI O1H +0.00 MRPC 9R DSI's SG B 19 19 DSI O1H +0.03 Bobbin SG B SAI O1H -0.01 MRPC 9R DSI's SG B 19 23 DSI 02H +0.03 Bobbin SG B SAI 02H -0.01 MRPC 9R DSI's SG B 19 28 ODI 20 AVI +0.00 Bobbin SG B 19 31 DSI 02H -0.03 Bobbin SG B 19 37 DSI O1H -0.06 Bobbin SG B 19 39 DSI O1H +0.00 Bobbin SG B MAI O1H -0.05 MRPC BR DSI's SG B 19 43 DSI O1H +0.18 Bobbin SG B 19 56 DSI O1H +0.06 Bobbin SG B MAI O1H +0.00 .MRPC 9R DSI's SG B 19 58 DSI 02H +0.03 Bobbin SG B 19 62 DSI O1H +0.06 Bobbin SG B SAI O1H -0.01 MRPC 9R DSI's SG B 19 65 DSI' O1H +0.06 Bobbin l SG B SAI' O1H -0.14 MRPC 9R DSI's ? SG B 19-68 DSI O1H +0.03 Bobbin I SG B 19 82 DSI 03H +0.00 Bobbin SG B 20 21 ODI 29.01H -0.06 Bobbin .) SG P 20 25'DSI O1H +0.00 Bobbin' l SG B SAI O1H -0.13 MRPC 9R DSI's 1 SG B 20 26 DSI OIH +0.03 Bobbin' SG B MAI O1H -0.04 MRPC ER DSI's-SG B 20 29 DSI O1H +0.03 Bobbin SG B DSI 02H -0.09 Bobbin SG B SAI 02H -0.11 MRPC 9R DSI's SG B 20 31 DSI 01H -0.03 Bobbin SG B SAI O1H -0.08 MRPC 9R DSI's SG B 20 35 DSI O1H +0.00 Bobbin s

BWNS TUBAN II (Version 1.0) 10/22/1993 14:16:47 Beaver Valley Unit 1 SG B t l 4/93 RFO Page 9 of 13 i STEAM GENERATOR B (RC-E-1B) j 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 20 48 DSI O1H +0.06 Bobbin SG B 20 69 DSI 02H +0.06- = Bobbin SG B SAI 02H +0.05 MRPC 9R DSI's SG B 20 89 ODI 22 Olc -0.25 Bobbin SG B 21 6 ODI 13 Olc -0.20 Bobbin SG B 21 12 DSI O1H +0.06 Bobbin SG B 21 13 DSI 02H -0.09 Bobbin r SG B 21 18 DSI O1H -0.03 Bobbin l SG B SAI O1H - -0.01 MRPC BR DSI's SG B 21 20 DSI O1H +0.06 Bobbin SG B MAI O1H -0.10 MRPC 9R DSI's l SG B 21 25 DSI O1H +0.06 Bobbin SG B 21 26 PVN Olc +26.06 Bobbin SG B 21 33 DSI O1H -0.03 Bobbin SG b SAI O1H -0.06 MRPC 9R DSI's + SG B 21 34 DSI O1H +0.09 Bobbin SG B 21 39 DSI O1H +0.00 Bobbin ' i SG B -21 40 DSI O1H +0.03 Bobbin SG B 21 46 DSI O1H +0.00 Bobbin SG B SAI O1H -0.03 MRPC 9R DSI's [ SG B 21 47 DSI 02H +0.03 Bobbin- 'i SG B 21 49 DSI O1H +0.03 Bobbin SG B SAI O1H +0.00 MRPC 9R DSI's -- i SG B 21 51 DSI 03H +0.03 Bobbin SG B 21 53 DSI 02H +0.03 Bobbin -l SG B 21 55 DSI O1H -0.03 Bobbin i SG B 21 57 DSI 02H +0.00 Bcbbin SG B 21 58 PVN TSH -0.41 MRPC TSH Wextex SG B 21 62 PVN TSH -1.39 MRPC TSH Wextex SG B 21 66 DSI O1H +0.03 Bobbin f SG B 21 67 PVN TSH -0.82 MRPC TSH Wextex SG B 21 83 DSI O1H +0.06 Bobbin i SG B 21 87 ODI 30 02C -0.20 Bobbin i SG B 22 10 DSI O1H +0.11 Bobbin SG B SAI 01H +0.01 MRPC 9R DSI's l SG B 22 11 DSI 02H +0.03 Bobbin l SG B SAI 02H +0.01 MRPC 9R DSI's SG B 22 19 DSI O2H +0.00 Bobbin 1 SG B 22 20 DSI 03H +0.06 Bobbin SG B 22 22 DSI O1H -0.03 Bobbin. SG B DSI 02H -0.06 Bobbin SG B SAI 02H -0.03 MRPC 9R DSI's f SG B 22 23 DSI O1H +0.00 Bobbin SG B 22 24 DSI O1H -0.03 Bobbin j SG B SAI O1H -0.07 MRPC BR DSI's -i SG B 22 27 DSI 03H +0.18 Bobbin SG B ODI 16 O1H +0.00 Bobbin SG B 22 41 DSI O1H -0.03 Bobbin SG B SAI O1H -0.02 MRPC 9R DSI's SG B 22 42 DSI O1H +0.09 Bobbin f SG B SAI O1H +0.08 MRPC 9R DSI's SG B 22 59 DSI 01H. +0.03-Bobbin SG B SAI O1H - +0.00 MRPC 9R DSI's t SG B 22 70 DSI '02H +0.09 Bobbin SG B 22 84 DSI O1H +0.03-Bobbin SG B - SAI O1H -0.03 MRPC 9R DSI's SG B 23 9 ODI 34 Olc -0.08 Bobbin i SG B 23 17 PVN 07H +3.04-Bobbin l SG B 23 52 DSI O1H +0.06 Bobbin i SG B DSI 02H +0.12 Bobbin SG B 23 55 ODI 14 AV3 +0.00 Bobbin SG B .ODI 19 AV4 +0.03 Bobbin SG B 23 86 ODI 24 Olc -0.11 Bobbin i SG B ODI 32 02C -0.19 Bobbin SG B 23 88 ODI 27 Olc -0.16 Bobbin {

l .BWNS TUBAN II (Version 1.0) 10/22/1993 14:16:47 Beaver Valley Unit 1 SG B 4/93 RFO i r Page 10 of 13 STEAM GENERATOR B (RC-E-1B) 9R INDICATIONS I GEN ROW COL IND %TW LOCATION TEST TYPE i SG B 24 11 DSI O1H -0.06 Bobbin SG B 24 36 DSI O1H +0.09 Bobbin' SG B 24 38 DSI O1H +0.09 Bobbin SG B '24 40 DSI O1H +0.06 Bobbin SG B ODI 23 01H +0.06 Bobbin SG B 24 41 DSI O1H +0.00 Bobbin SG B 24 46 DSI O1H +0.12 Bobbin-1 SG B 24 55 DSI O1H +0.09 Bobbin ? SG B 24 56 DSI 02H +0.09 Bobbin SG B 24 58 ODI 22 02H +0.03 Bobbin SG B 24 60 DSI 02H +0.03 Bobbin SG B 24 86 ODI 11 01C -0.11 Bobbin SG B 24 87 ODI 25 Olc -0.03 Bobbin SG B 25 10 ODI 16 01C -0.17 Bobbin SG B ODI 32 02C +0.08 Bobbin SG B 25 21 DSI O1H +0.03 Bobbin SG B SAI O1H +0.00 MRPC 9R DSI's SG B 25 22 DSI O1H +0.09 Bobbin SG B 25 84 ODI 30 Olc -0.32 Bobbin SG B 26 85 ODI 32 02C -0.25 Bobbin SG B 27 13 ODI 18 Olc -0.12 Bobbin SG B 27 47 DSI O1H +0.03 Bobbin SG B 27 62 DSI O1H +0.09 ' Bobbin SG B SAI 01H +0.00 MRPC 9R DSI's SG B 27 84 ODI 12 Olc -0.15 Bobbin SG B 27 85 ODI 31 Olc -0.14 Bobbin SG B 28 60 ODI 15 07C -0.03 Bobbin SG B 28 82 ODI 22 Olc +0.00 Bobbin' SG B 29 12 ODI 19 O1H +0.27 Bobbin SG B 29 14 ODI 26 Olc -0.15 Bobbin SG B 29 16 ODI 14 AV1 30.00 Bobbin SG B 29 84 ODI 24 Olc -0.20 Bobbin SG B 30 14 ODI 31 Olc -0.21 Bobbin SG B 30 16 ODI 34 Olc -0.15 Bobbin SG B 30 28 ODI 11 AV2' -0.18 Bobbin SG B 30 81 ODI 18 Olc -0.12 Bobbin SG B 30 82 ODI 15 02C -0.06 Bobbin SG B ODI 18 01C -0.12 Bobbin SG B 31 13 SAI O1H +0.30 MRPC BR DSI's SG B 31 15 ODI 34 Olc -0.24 Bobbin SG B 31 17 ODI 26 Olc -0.24 Bobbin SG B 31 22 DSI O2H +0.06 Bobbin SG B 31 36 DSI O1H +0.03 Bobbin SG B DSI 02H -0.03-Bobbin SG B 31 66 SAI O1H -0.08 MRPC 8R DSI's SG B 31 73 DSI 019 +0.06 Bobbin SG B 31 78 ODI 35 02C -0.21 Bobbin SG B 31 80 ODI 32 Olc ' -0.03 Bobbin SG B 32 46 ODI AV4 +0.00 Bobbin SG B ODI 28 AV2 +0.39 Bobbin-- SG B ODI 31 AV3 +0.00 Bobbin SG B 32 53 ODI 18 AV1 +0.00 Bobbin SG.B-ODI 25 AV3 +0.00 Bobbin SG B ODI' 34 AV2 +0.00 Bobbin SG B 32 78 ODI 19 02C -0.15 Bobbin SG S ODI 21 Olc -0.24 Bobbin SG B 33 34 DSI O2H -0.06 Bobbin SG B DSI 05H +0.19-Bobbin SG B 33 39 DSI O1H +0.08 Bobbin. SG B ODI 25 03H +0.03 Bobbin SG B SAI O1H +0.11 MRPC 9R DSI's SG B 33 .40 DSI O1H '+0.09 Bobbin SG B SAI O1H +0.05 MRPC BR DSI's SG B 33 51 DSI' O1H +0.03 Bobbin-SG B DSI 02H -0.03 Bobbin

~ BWNS TUBAN II (Version 1.0) 10/22/1993 14:16:47 Beaver Valley Unit 1 SG B 4/93 RFO. [ i Page 11 of 13-l STEAH GENERATOR B (RC-E-1B) L 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE j SG B SAI O1H -0.01 MRPC 9R DSI's SG B 33 59 DSI 02H +0.03 Bobbin SG B 33 61 DSI O1H +0.03 Bobbin i SG-B 33 79 ODI 24 01C +0.06 Bobbin SG B 34 18 ODI 32 02C +0.11 Bobbin SG B 34 24 DSI O1H +0.00 Bobbin SG B SAI O1H +0.01 MRPC 9R DSI's SG B 34 26 ODI 24 O1H +0.11 Bobbin SG B 34 28 DSI 03H +0.08 Bobbin i SG B 34 33 DSI 01H +0.14 Bobbin SG B 34 36 DSI 03H -0.05 Bobbin i SG B ODI 17 O1H +0.13 Bobbin I SG B 34 41 DSI 02H -0.05 Bobbin SG B SAI O2H +0.02 MRPC 9R DSI's SG B 34 43 DSI 05H +0.03 Bobbin SG B SAI OSH +0.03 MRPC 9R DSI's SG B' 34-44 DSI O1H -0.11 Bobbin SG B DSI O2H -0.03 Bobbin -i SG B 34 45 DSI 03H +0.08 Bobbin SG B 34 46 DSI O1H +0.03 Bobbin SG B ODI 27 AV1 +0.00 Bobbin SG B ODI 32 AV3 +0.00 Bobbin .{ SG B ODI 34 AV2 +0.00 Bobbin 1 SG B 34 77 ODI 39 Olc -0.15 Bobbin k SG B ODI 42 02C -0.24 Bobbin SG B 34 78 ODI 25 Olc -0.15 Bobbin SG B 34 79 ODI 11 01C -0.06 Bobbin SG B 35 17 ODI 33 Olc -0.34 Bobbin SG B 35 18 ODI 20 02C -0.22 Bobbin-SG B 35 26 DSI O1H +0.08 Bobbin SG B MAI O1H +0.00 MRPC 9R DSI's SG B 35 27 ODI 27 O1H +0.00 Bobbin .i SG B MAI O1H -0.03 MRPC 8R DSI's SG B 35 28 DSI 03H +0.06 Bobbin i SG B 35 34 DSI O1H +0.11 Bobbin SG B DSI 02H +0.08 Bobbin SG B 35 37 ODI 26 02H +0.03 Bobbin i SG B 35 75 ODI 38 02C -0.18 Bobbin l SG B 35 78 ODI 3 01C -0.12 Bobbin i SG B 36 23 DSI O1H +0.11 Bobbin I -SG B DSI 03H +0.08 Bobbin t SG B 36 26 ODI 25 AV3 +0.00 Bobbin-SG B 36 30 DSI O1H +0.11 Bobbin f SG B 36 68 ODI 20 03C +34.55 Bobbin SG B 36 73 ODI 36 01C -0.24 Bobbin + SG B 36 75 ODI -10 01C +0.00 Bobbin SG B 37 21 ODI 28 02C -0.25 Bobbin SG B 37 22 ODI 12 02C -0.25 Bobbin' t SG B 37 31 DSI O1H +0.03 Bobbin l SG B SAI O1H +0.01 KRPC 9R DSI's SG B 37 59 ODI 37 AV2 +0.00 Bobbin j SG B ODI 38 AVI +0.00 Bobbin i SG B 37 62 ODI 20 AV4 +0.00 Bobbin-SG B ODI 34 AV3 +0.00 Dobbin SG B-37 74 ODI 24 02C +0.06-Bobbin SG B 37 76 ODI 10 02C -0.21 Bobbin SG B 38 E21 ODI 13 02C -0.16 Bobbin SG B 38 24 ODI 31 O1H +0.24 -Bobbin SG B SAI O1H +0.21 MRPC Special In SG B 38 31 DSI O1H +0.04 Bobbin SG B 38 32 DSI 02H +0.00 Bobbin SG B 38 69 ODI 17 02C -0.12 Bobbin SG B-38 72 ODI 25 02C +0.09 Bobbin SG B 39 23 ODI 30 02C -0.24 Bobbin 1 SG B 39 24 ODI 6 02C -0.21 Bobbin -1 l i

e.....r********* BWNS TUBAN II (Version'1.0) 10/22/1993-14:16:47 Beaver Valley Unit 1 SG B 4/93 RFO Page 12 of 13 STEAM GENERATOR B (RC-E-1B) 9R INDICATIONS GEN ROW COL'IND %TW LOCATION TEST TYPE SG B 39 25 ODI 39 02C -0.24 Bobbin SG B 39 26 ODI 13 Olc -0.24 Bobbin SG B 39 39 ODI 29 AV4 +0.00 Bobbin SG B ODI 35 AV3 +0.00 Bobbin SG B 39 44 DSI 02H +0.12 Bobbin SG B SAI 02H +0.06 MRPC 9R DSI's SG B 39 52 ODI 35 01H +0.12 Bobbin SG B 39 55 DSI O1H +0.06 Bobbin SG B SAI O1H -0.04 MRPC 9R DSI's SG B 39 56 ODI 20 AV3 +0.00 Bobbin SG B ODI 24 AV4 +0.00 Bobbin SG B 39 58 ODI 35 AV3 +0.00 Bobbin SG B 39 61 ODI 31 AV3 +0.00 Bobbin SG B 39 71 ODI 10 02C -0.24 Bobbin SG B 39 72 ODI 34 02C +0.12 Bobbin SG B 39 73 ODI 14 02C +0.12 Bobbin SG B 40 25 ODI 37 Olc -0.18 Bobbin SG B ODI 40 02C -0.24 Bobbin SG B 40 27 ODI 17 02C -0.21 Bobbin SG B 40 28 ODI 16 02C -0.15 Bobbin SG B 40 49 DSI O1H +0.03 Bobbin SG B SAI O1H -0.03 MRPC 9R DSI's SG B 40 70 ODI 31 01C -0.24 Bobbin SG B ODI 36 02C -0.24 Bobbin SG B 40 71 DSI 02H +0.15 Bobbin SG B 41 26 ODI 34 02C -0.24 Bobbin !;G B 41 27 ODI 38 02C -0.24 Bobbin SG B 41 30 ODI 42.02C +0.09 Bobbin SG B 41 43 ODI 16 AV4 +0.00 Dobbin SG B ODI 21 AV3 -0.06 Bobbin SG B ODI 25 AV2 +0.06 Bobbin-SG B 41 51 ODI 29 AV3 +0.00 Bobbis. SG B ODI 34 AV4 +0.00 Bobbin SG B 41 66 ODI 30 Olc -0.18 Bobbin SG B 42 28 ODI 27 02C -0.06 Bobbin SG B 42 29 ODI 33 02C -0.09 Bobbin SG B 42 30 ODI 23 02C -0.21 Bobbin SG B 42 33 ODI 35 02C -0.24 Bobbin SG B 42 36 ODI 33 01C -0.18 ' Bobbin. SG B 42 45 DSI DEH +0.06 Bobbin SG B 42 51 DSI O1H +0.06 Bobbin SG B SAI 01H -0.05 MRPC 9R DSI's SG B 42 57 DNT 07H +38.39 Bobbin SG B ODI 27 Olc -0.24' Bobbin SG B 42 59 ODI 16 02C -0.15 Bobbin SG B 42 66 ODI-43 Olc -0.03 Bobbin SG B 43 30 ODI 46 02C -0.11 Bobbin SG B 43 34 ODI 24 Olc -0.23 Bobbin SG B ODI 25 02C -0.26 Bobbin SG B 43 35 ODI 42 02C -0.20 Bobbin SG B 43 48 DSI O1H -0.06 Bobbin SG B 43 55 ODI 41'01C -0.09 Bobbin SG B 43 58 ODI 22 Olc -0.18 Bobbin SG B ODI 46 TSH +1.83 Bobbin SG B SAI TSH +0.00 MRPC Special In SG B VOL TSH +2.24 MRPC Special In SG B 43 59 ODI. 23 Olc -0.27 Bobbin SG B 43 60 ODI 32 Olc -0.21 Bobbin SG B ODI 41 02C -0.27 Bobbin' SG B 43 65 CDI 29 02C +0.06 Bobbin SG B 44 33 ODI 26 Olc -0.14 d;bbin SG B ODI 42 02C -0.09 Bobbin SG B 44 34 ODI 11 Olc +0.00 Bobbin SG B 44 37 ODI 9 Olc -0.17 Bobbin SG B 44 38 ODI-15 01C -0.08 Bobbin

BWNS TUBAN II (Version 1.0) 10/22/1993 14:16:47 .**......**r'*** Beaver Valley Unit 1 SG B 4/93 RPO Page 13 of 13 STEAM GENERATOR B (RC-E-1B) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B ODI L4 02C -0.20 Bobbin 3 SG B 44 43 ODI 21 02C -0.23 Bobbin SG B 44 44 ODI 11 01C -0.08 Bobbin SG B 44 46 ODI 16 Olc +0.10 Bobbin l SG B 44 50 ODI 16 AV4 +0.00 Bobbin SG B ODI 25 02C -0.27 Bobbin SG B 44 53 ODI 36 Olc -0.12 Bobbin l SG B 44 55 ODI 46 02C -0.18 Bobbin i SG B 44 57 ODI 25 01C -0.06 Bobbin SG B ODI 36 02C -0.03 Bobbin SG B 44 58 ODI 29 Olc -0.12 Bobbin SG B 44 59 ODI 10 Olc -0.18 Bobbin SG B ODI 30 02C -0.21 Bobbin SG B 44 61 ODI 42 OIC -0.18 Bobbin SG B 44 62 ODI 16 O1H +0.14 Bobbin SG B ODI 35 02C -0.20 Bobbin SG B ODI 37 02C -0.27 Bobbin SG B 45 36 ODI 18 Olc +0.00 Bobbin i SG B ODI 36 02C -0.08 Bobbin SG B 45 37 ODI 26 02C -0.04 Bobbin SG B 45 38 ODI 13 Olc -0.09 Bobbin SG B 45 40 ODI 31 03H +0.27 Bobbin SG B 45 42 ODI 24 02C -0.22 Bobbin SG B ODI 26 Olc -0.17 Bobbin SG B 45 43 ODI 4 02C -0.02 Bobbin SG B ODI 22 Olc -0.06 Bobbin SG B 45 44 ODI 13 02C -0.13 Bobbin SG B ODI 24 01C -0.15 Bobbin l SG B 45 46 ODI 25 01C -0.17 Bobbin SG B 45 47 ODI 25 01C -0.25 Bobbin SG B 45 49 ODI 31 Olc -0.18 Bobbin. SG B 45 50 ODI 43 Olc -0.12 Bobbin SG B 45 51 ODI 40 01C -0.03 Bobbin SG B 45 53 ODI 18 02C -0.24 Bobbin SG B ODI 33 Olc -0.15 Bobbin SG B 45 54 ODI 14 TSC +37.42 Bobbin SG B ODI 15 02C -0.21 Bobbin SG B ODI 17 TSH +10.66 Bobbin SG B ODI 28 TSH +11.43 Bobbin SG B ODI 29 Olc +0.09-Bobbin SG B 45 55 ODI 28 TSH +3.26 Bobbin SG B ODI 43 02C -0.18 Bobbin SG B VOL TSH +2.91 MRPC TSH Wextex SG B 45 56 ODI 26 02C -0.12 Bobbin SG B 45 57 ODI 26 01C -0.09 Bobbin SG B 45 58 ODI 21 01C -0.15 Bobbin SG B 45 59 ODI 41 02C -0.30 Bobbin-SG B 46 44 ODI 29 01C +0.09 Bobbin SG B 46 45 ODI 34 02C -0.17 Bobbin SG B 46 46 ODI 26 OIC -0.12 Bobbin SG B ODI 34 02C -0.04 Bobbin I SG B 46 49 ODI 12 Olc -0.18 Bobbin Total Indications Found = 832 rotal Tubes Found = 551 l

i BWHS TUBAN II (Version 1.0) 10/22/1993 10:39:16 j Beaver Valley Unit 1 SG B 4/93 RFO f Page 1 of 4 l STEAM GENERATOR B (RC-E-1B) 9R PLUGGED TUBES GEN ROW COL IND %TW LOCATION TEST TYPE SG B 1 1 SAI 02H +0.09 MRPC 9R DSI's SG B 1 3 SAI 07H +10.03 MRPC U-Bend SG B MAI O1H +0.03 MRPC 9R DSI's SG B 1 7 SAI 07H +10.15 MRPC U-Bend SG B 1 11 SAI 07H +9.91 MRPC U-Bend SG B 1 15 MAI O2H +0.00 MRPC 9R DSI's i SG B SAI O1H +0.11 MRPC 9R DSI's SG B 1 16 SAI O1H +0.02 MRPC 9R DSI's i SG B 1 18 SAI 07H +4.51 MRPC U-Bend SG B 1 20 SAI 07H +10.14 MRPC U-Bend SG B SAI-01H -0.02 MRPC 8R DSI's SG B 1 21 SAI O1H +0.05 MRPC 9R DSI's SG B 1 25 ODI 17 02H -0.11 Bobbin-l SG B SAI 07H +10.41 MRPC U-Bend SG B 1 26 SAI 07H +10.27 MRPC U-Bend SG B 1 30 SAI 07H +10.01 MRPC U-Bend SG B 1 35 SAI 07H +10.45 MRPC U-Bend SG B 1 37 SAI 07H +10.20 MRPC U-Bend SG B 1 41 SAI 07H +11.14 MRPC U-Bend SG B 1 42 SAI 07H +10.24 MRPC U-Bend j SG B 1 53 SAI 07H +9.60 MRPC U-Bend SG B 1 56 SAI 07H +3.45 MRPC U-Bend i SG B SAI 07H +3.97 MRPC U-Bend SG B 1 59 SAI 07H +3.49 MRPC U-Bend SG B 1 61 ODI 22 O1H -0.03 Bobbin SG B SAI 07H +3.56 MRPC U-Bend SG B 1 73 SAI 07H +3.72 MRPC U-Bend SG B 1 74 MAI 07H +3.74 MRPC U-Bend SG B 1 30 S4I 07H +10.14 MRPC U-Bend SG B 2 8 SAI O1H +0.09 MRPC 9R DSI's SG B 2 9 SAI O1H +0.04 MRPC 9R DSI's SG B 2 10 SAI 07C +4.46 MRPC U-Bend SG B 2 21 NQI TSH- +0.31 Bobbin SG B 2 22 SAI O1H +0.01 MRPC 9R DSI's SG B 2 34 ODI 20 04H +0.00 Bobbin SG B SAI O1H +0.00 MRPC 9R DSI's SG H SAI 02H +0.02 MRPC 9R DSI's SG B 2 38 SAI 02H +0.03 MRPC BR DSI's SG B 2 60 SAI O1H +0.17 MRPC 9R DSI's SG B 2 71 SAI 02H +0.00 MRPC 8R DSI's SG B 3 2 SAI O1H -0.05 MRPC 9R DSI's SG B 3 21 SAI O1H +0.00 MRPC 9R DSI's SG B 3 27 SAI O1H -0.08 MRPC 9R DSI's SG B 3 55 SAI O1H -0.06 MRPC 9R DSI's SG B 3 68 SAI 03H +0.04 MRPC 9R DSI's l SG B 3 75 MAI 03H -0.12 MRPC 8R DSI's SG B 3 92 SAI 02H -0.12 MRPC BR DSI's SG B 4 5 SAI 02H +0.01 MRPC 9R DSI's SG B 4 6 SAI 02H +0.00 MRPC 8R DSI's SG B 4 13 SAI O1H' +0.10 MRPC 9R DSI's SG B 4 14 SAI O2H -0.04 MRPC 9R DSI's SG B 4 29 SAI O1H -0.07 MRPC BR DSI's SG B 4 31 SAI O1H -0.04 MRPC 9R DSI's SG B 4 58 SAI O1H -0.03 MRPC 9R DSI's + SG B 4 60 SAI O1H +0.01 MRPC 9R DSI's SG B 4 84 MAI 02H +0.05 MRPC BR DSI's I SG B 5 12 MAI 02H -0.01 MRPC 9R DSI's SG B 5 35 SAI O2H +0.02 MRPC 9R DSI's SG B 5 41 SAI O1H +0.00 MRPC BR DSI's ? SG B 5 47 SAI O1H -0.06 MRPC 9R DSI's SG B 5 79 SAI 02H +0.04 MRPC 9R DSI's SG B 6 5 SAI O1H -0.09 MRPC BR DSI's SG B 6 9 MAI O1H -0.08 MRPC 9R DSI's SG B 6 23 SAI 03H -0.02 MRPC 9R DSI's i SG B 6 28 SAI O1H +0.03 MRPC 8R DSI's

I l l~ l I I BWNS TUBAN II (Version 1.0) 10/22/1993 10:39:16 Beaver Valley Unit 1 i ...e************ SG B l 4/93 RFO i l Page'2 of 4 l STEAM GENERATOR B (RC-E-1B) l 9R PLUGGED TUBES GEN RDW COL IND %TW LOCATION TEST TYPE SG B 6 36 SAI O1H -0.10 MRPC 9R DSI's SG B SAI 02H -0.08 MRPC 9R DSI's SG B SAI 03H -0.04 MRPC BR DSI's SG B 6 40 SAI O1H +0.03 MRPC BR DSI's i i SG B 6 78 SAI O1H +0.04 MRPC 9R DSI's SG B 6 93 ODI 40 02C -0.15 Bobbin i SG B 7 6 MAI O1H +0.03 MRPC BR DSI's SG B 7 8 SAI O2H +0.01 MRPC 9R DSI's i SG B 7 9 MAI O1H -0.12 HRPC 9R DSI's i SG B 7 20 MAI 01H +0.01 MRPC 9R DSI's SG B SAI 03H +0.00 MRPC 9R DSI's SG B 7 21 SAI O1H +0.00 MRPC 9R DSI's SG B 7 22 SAI O1H +0.00 MRPC BR DSI's SG B 7 58 SAI O1H +0.03 MRPC 9R DSI's l SG B 8 13 SAI O1H -0.09 MRPC 9R DSI's SG B 8 18 SAI. 01H +0.00 dRPr 9R DSI's SG B 8 47 SAI 01H -0.04 MRP. 9R DSI's SG B 8 50 SAI O1H +0.00 MRPC 9R DSI's SG B 9 10 SAI O1H +0.00 MRPC 9R DSI's SG B 9 13 SAI O1H -0.04 MRPC BR DSI's I SG B 9 19 SAI O1H +0.00 MRPC 9R DSI's SG B 9 22 SAI O1H -0.06 MRPC 9R DSI's SG B 9 29 ODI 42 TSH +1.17 Bobbin 'i SG B 9 31 SAI O1H +0.00 MRPC BR DSI's SG B 9 32 ODI 47 TSH +1.47 Bobbin i SG B 9 34 ODI 60 TSH +1.18 Bobbin l SG B 9 36 NQI TSH +0.96 Bobbin l SG B ODI 32 02H -0.03 Bobbin SG B VOL TSH +0.75 MRPC TSH Wextex SG B 9 41 SAI O1H +0.01 MRPC 9R DSI's SG B 9 59 SAI O1H +0.02 MRPC BR DSI's SG B 9 72 SAI O1H +0.01 MRPC BR DSI's SG B 9 82 SAI O1H -0.07 MRPC 9R DSI's SG B 9 83 SAI O1H -0.08 MRPC BR DSI's SG B 10 4 SAI O1H +0.00 MRPC 9R DSI's SG B 11 41 ODI 42 TSH +1.41 Bobbin SG B VOL TSH +1.34 MRPC TSH Wextex SG B 11 47 NQI TSH +0.80 Bobbin SG B 12 7 MAI O1H +0.00 MRPC 9R DSI's SG B MAI 03H -0.02 MRPC 9R DSI's SG B SAI 02H +0.00 MRPC 9R DSI's i SG B 12 Il MAI O1H -0.02 MRPC 9R DSI's i SG B 12 15 ODI 62 O1H +0.12 Bobbin SG B 12 19 SAI 02H +0.04 MRPC 9R DSI's SG B 12 22 MAI O1H -0.14 MRPC 8R DSI's SG B SAI 02H -0.01 MRPC 9R DSI's SG B 12 32 SAI O2H +0.01 MRPC 9R DSI's SG B 12 34 ODI 57 TSH +2.40 Bobbin SG B 12 37 SAI 01H -0.02 MRPC BR DSI's SG B 12 40 SAI O1H +0.05 MRPC BR DSI's SG B 12 80 SAI O1H +0.11 MRPC 9R DSI's SG B 13 3 SAI 01H +0.03 MRPC 9R DSI's ) SG B 13 22 SAI 01H -0.11 MRPC 9R DSI's SG B 13 25 NQI TSH +0.50 Bobbin SG B 13 26 ODI b2 TGh +0.57 Bobbin SG B SAI O1H +0.01 MRPC BR DSI's SG B 13 33 ODI 84 TSH +2.47 Bobbin SG B SAI O2H +0.02 MRPC 9R DSI's SG B 13 35 ODI 44 TSH +2.71 Bobbin SG B 13 36 ODI 25 TSH +2.65 Bobbin SG B 13 53 SAI O1H +0.00 MRPC 9R DSI's SG B 13 69 SAI O1H +0.01 MRPC 9R DSI's SG B 13-73 MAI O1H -0.04 MRPC BR DSI's SG B 14 13 SAI 02H -0.01 MRPC 9R DSI's i SG B 14 28 SAI O1H +0.00 MRPC 9R DSI's i

BWNS TUBAN II (Version 1.0) 10/22/1993 10:39:16 i l Beaver Valley Unit 1 SG B 'i 4/93 RFO STEAM GENERATOR B (RC-E-1B) 9R PLUGGED TUBES GEN ROW COL IND %TW LOCATION TEST TYPE SG B 14 41 MAI O1H +0.00 MRPC 9R DSI's: SG.B 15 10 SAI 02H -0.02 MRPC 9R DSI's SG B 15 11 LAI O1H -0.07 MRPC 9R DSI's SG B 15 12 SAI-O1H +0.07 MRPC 9R DSI's SG B SAI 02H +0.06 MRPC 9R DSI's SG B 15 30 ODI 54 TSH +1.43 Bobbin SG B 15 31 ODI 47 TSH +1.23 Bobbin SG B 15 32 ODI 65 TSH +1.27 Bobbin SG B 15 35 ODI 36 TSH +2.37 Bobbin SG B 15 37 SAI OIH +0.02 MRPC 9R DSI's SG B 15 39 SAI O1H +0.01 MRPC 9R DSI's SG B 15 51 VOL TSH +0.95 MRPC TSH Wextex SG B 16 30 ODI 78 TSH +0.70 Bobbin SG B 16 35 ODI 78 TSH +0.89 Bobbin j SG B 16 41 SAI 01H +0.00 MRPC 9R DSI's SG B.17 13 SAI 02H +0.01 MRPC 9R'DSI's SG B 17 15 SAI O1H -0.02 MRPC 9R DSI's SG B 17 23 SAI O1H +0.00 MRPC 9R DSI's SG B 17 24 SAI O1H -0.09 MRPC 9R DSI's SG B 17 35 SAI O1H +0.01 MRPC 9R DSI's SG B 17 48 SAI 02H +0.02 MRPC 9R DSI's SG B 17 56 MAI O1H +0.07 MRPC 9R DSI's SG B 18 12 SAI O1H -0.03 MRPC 9R DSI's SG B 18 26 SAI O1H +0.01 MRPC 9R DSI's 1 SG B 18 32 ODI 64 TSH +0.49 Bobbin l SG B 18 40 ODI 41 TSH +0.76 Bobbin

f SG B 18 54 SAI O1H

-0.02 MRPC 9R DSI's i SG B 18 76 SAI 01H -0.05 MRPC 9R DSI's SG B 19 10 SAI O1H +0.00 MRPC.9R DSI's SG B 19 19 SAI O1H -0.01 MRPC 9R'DSI's f SG B 19 23 SAI O2H -0.01 MRPC 9R DSI's SG B 19 39 MAI O1H- -0.05 MRPC BR DSI's. SG B 19 56 MAI O1H +0.00 MRPC 9R DSI's SG B 19 62 SAI O1H -0.01 MRPC 9R DSI's SG B 19 65 SAI O1H -0.14 MRPC 9R DSI's SG B 20 25 SAI O1H -0.13 MRPC 9R DSI's. SG B 20 26 MAI O1H -0.04 MRPC BR DSI's SG B 20 29 SAI 02H -0.11 MRPC 9R DSI's SG B 20 31 SAI O1H -0.08 MRPC 9R DSI's SG B 20 69 SAI 02H +0.05 MRPC 9R DSI's SG B 21 18 SAI O1H -0,01 MRPC BR DSI's SG B 21 20 MAI O1H -0.30 MRPC 9R DSI's SG B 21 33 SAI O1H -0.06 MRPC 9R DSI's SG B 21 46 SAI O1H -0.03 MRPC 9R DSI's SG B 21 49 SAI O1H +0.00 MRPC 9R DSI's SG B 22 10 SAI O1H +0.01 MRPC 9R DSI's SG B 22 11 SAI 02H +0.01 MRPC 9R DSI's SG B 22 22 SAI 02H. -0.03 MRPC 9R DSI's. i SG B 22 24 SAI O1H -0.07 MRPC BR DSI's. ~ SG B 20 41 SAI 01H -0.02 MRPC 9R DSI's SG B 22 42 SAI O1H +0.08-MRPC 9R DSI's SG B 22 59 SAI O1H +0.00 MRPC 9R DSI's SG B 22. 84 SAI O1H -0.03 MRPC 9R DSI's SG B 25 21 SAI O1H +0.00 MRPC 9R DSI's SG B 27 62 SAI O1H +0.00 MRPC 9R DSI's SG B 31 13 SAI O1H +0.30 MRPC'8R DSI's SG B 31 66 SAI O1H -0.08 MRPC BR DSI's SG B 33 39 ODI 25 03H +0.03 Bobbin SG B SAI O1H +0.11 MRPC 9R DSI's SG B 33 40 SAI' O1H +0.05 MRPC BR DSI's J SG B 33 51 SAI O1H -0.01 MRPC 9R DSI's SG B 34 24 SAI O1H +0.01 MRPC 9R DSI'm SG B 34 41 SAI 02H +0.02 MRPC 9R DSI's SG B 34 43 SAI 05H +0.03 MRPC 9R DSI's-SG B 34 77 ODI 39 Olc -0.15 Bobbin

p j BWNS TUBAN II (Version 1.0) '10/22/1993 10:39:16 Beaver Valley Unit 1 J SG B 4/93 RFO ~ STEAM GENERATOR B (RC-E-1B) 9R PLUGGED TUBES GEN ROW COL IND %TW LOCATION TEST TYPE SG B ODI 42 02C -0.24 Bobbin SG B 35 26 MAI O1H +0.00 MRPC 9R DSI's SG B 35 27 ODI 27 01H +0.00 Bobbin l SG B MAI O1H -0.03 MRPC BR DSI's e SG B 37 31 SAI O1H +0.01 MRPC 9R DSI's SG B 38 24 ODI 31 O1H +0.24 Bobbin i SG B SAI O1H +0.21 MRPC Special In SG B 39 44 SAI 02H +0.06 MRPC 9R DSI's SG B 39 55 SAI O1H -0.04 hAPC 9R DSI's SG B 40 25 ODI 37 Olc -0.18 Bobbin' SG B ODI 40 02C -0.24 Bobbin SG B 40 49 SAI O1H -0.03 MRPC 9R DSI's SG B 41 30 ODI 42 02C +0.09 Bobbin SG B 42 51 SAI O1H -0.05 MRPC 9R DSI's SG B 42 66 ODI 43 01C -0.03 Bobbin i SG B 43 30 ODI 46 02C -0.11 Bobbin SG B 43 35 ODI 42 02C -0.20 Bobbin i SG B 43 55 ODI 41 Olc -0.09 Bobbin { SG B 43 58 ODI 22 Olc -0.18 Bobbin SG B ODI 46 TSH +1.83 Bobbin 4 SG B SAI TSH +0.00 MRPC Special In SG B VOL TSH +2.24 MRPC Special In SG B 43 60 ODI 32 Olc -0.21 Bobbin i SG B ODI 41 02C -0.27 Bobbin SG B 44 33 ODI 26 Olc -0.14 Bobbin i SG B ODI 42 02C -0.09 Bobbin i SG B 44 55 ODI 46 02C -0.18 Bobbin SG B 44 61 ODI 42 01C -0.18 Bobbin SG B 45 50 ODI 43 Olc -0.12 Bobbin SG B 45 SI ODI 40 Olc -0.03 Bobbin SG B 45 55 ODI 28 TSH +3.26 Bobbin SG B ODI 43 02C -0.18 Bobbin SG B VOL TSH +2.91 MRPC TSH Wextex SG B 45 59 ODI 41 02C -0.30 Bobbin Total Indications Found = 229 Total Tubes Found = 197 Total Tubes in Input File = 499 l I i i j 1 I

ATTACHMENT 3 CSIT #: 9TH REFLELING OLTAGE STEAM GENERATOR "C" (RC-E-1C)

4 eeeeeeeeeeeeee** BWNS-TUBAN II (Version 1.0). 10/22/1993 14:25:31 l Beaver Valley Unit 1 SG.C 4/93 RFO Page 1 of 9 STEAM GENERATOR C (RC-E-1C) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE l t SG C 1 1 ODI 43 TSH +17.64 Bobbin i SG C SAI 07H +3.72 MRPC U-Bend i SG C 1 2 ODI 47 TSH +17.61 Bobbin 1 SG C SAI 07H +3.79 MRPC U-Bend SG C 1 5 ODI 34 TSH +17.78 Bobbin SG C 1 7 SAI 07H +3.86 HRPC U-Bend SG C 1 17 DSI 06H -0.09 Bobbin SG C 1 44 DSI 02H -0.03 Bobbin l SG C 1 45 DSI O1H -0.09 Bobbin SG C 1 47 DSI O1H -0.09 Bobbin i SG C 1 92-DSI 02H +0.00 Bobbin SG C SAI 02H +0.00 MRPC 9R DSI's SG C 2 3 ODI 16 04H -0.03 Bobbin SG C 2 6 DSI 02H -0.09 Bobbin SG C 2 7 DSI O1H +0.00 Bobbin SG C DSI 02H -0.06 Bobbin SG C DSI 02H -0.06 Bobbin i SG C 2 8 DSI O1H -0.23 Bobbin SG C 2 10 DSI O1H +0.00 Bobbin SG C DSI O1H -0.03 Sobbin SG C 2 11 DSI O1H -0.06 Bobbin SG C 2 13 DSI O1H -0.15 Bobbin SG C 2 14 DSI O1H -0.12 Bobbin 3G C 2 15 DSI O1H -0.06 Bobbin SG C DSI 02H +0.00 Bobbin SG C 2 18 DSI 02H -0.15 Bobbin SG C 2 19 DSI O1H -0.06 Bobbin SG C 2 21 DSI O1H -0.14 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C 2 22 DSI O1H -0.14 Bobbin SG C DSI 02H -0.12 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's i SG C 2 23 DSI O1H -0.14 Bobbin i SG C 2 25 DSI O1H -0.08 Bobbin SG C DSI O1H -0.06 Bobbin SG C DSI 02H -0.06 Bobbin i SG C 2 33 DSI O1H +0.03 Bobbin SG C 2 66 DSI O1H +0.00 Bobbin. SG C MAI O1H +0.03 HRPC 9R DSI*c '[ SG C 2 76 DSI 02H -0.06 Bobbin SG C 2 87 DSI 02H -0.12 Bobbin SG C 2 92 DSI 02H -0.05 Bobbin f SG C SAI 02H +0.00 MRPC 9R DSI's SG C 3 14 DSI 02H -0.03 Bobbin l SG C 3 22 DSI 02H -0.06 Bobbin SG C 3 26 DSI O1H -0.12 Bobbin SG C DSI 02H -0.09 Bobbin SG C 3 36 DSI O1H -0.06 Bobbin SG C 3 51 DSI 01H -0.09 Bobbin SG C 3 62 DSI O1H -0.06 Bobbin SG C 3 81 DSI 02H -0.09 Bobbin SG C 3 94 ODI 22 01C +0.00 Bobbin SG C 4 3 DSI O1H +0.12 Bobbin SG C 4 7 DSI 02H +0.03 Bobbin SG C 4 35 DSI O1H +0.06 Bobbin SG C 4 43 DSI O1H +0.05 Bobbin SG C 4 50 DSI 02H +0.09 Bobbin i SG C 4 61 DSI O1H +0.12 Bobbin i SG C 5 25 DSI 01H -0.03 Bobbin-SG C 5 26 DSI O1H +0.09 Bobbin SG C 5 28 DSI O1H +0.03 Bobbin SG C SAI O1H +0.09 MRPC 9R DSI's SG C 5 49 DSI O1H +0.00 Bobbin SG C 5 54 ODI 27 O1H +0.00 Bobbin SG C 5 60 DSI O1H +0.03 Bobbin l v

.. ~ ~ I BWNS TUBAN II (Version 1.0) 10/22/1993 14:25:31 j Beaver Valley Unit 1 -1 SG C 4/93 RFO } l Page 2 Eof 9 STEAH GENERATOR C (RC-E-1C) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C SAI O1H +0.01 MRPC 8R DSI's SG C 5 63 ODI 21 02C -0.03 Bobbin SG C 5 81 DSI O1H +0.09-Bobbin SG C 5 85 DSI 02H -0.03 Bobbin SG C 6 4 PVN 07H +25.80 Bobbin SG C 6 5 PVH 07H +22.65 Bobbin SG C 6 6 PVN 07H +22.27 Bobbin SG C 6 33 DSI O1H +0.06 Bobbin SG C SAI O1H -0.05 MRPC 9R DSI's' SG C 6 36 DSI O1H +0.00 Bobbin SG C 6 38 DSI O1H +0.08 Bobbin l SG C DSI O1H +0.13 Bobbin SG C 6 43 DSI O1H +0.00 Bobbin SG C 6 44 SAI O1H -0.07 MRPC BR DSI's SG C 6 81 DSI O1H +0.12 Bobbin SG C DSI 04H +0.00 Bobbin SG C 6 82 DSI O1H +0.06 0,bbin SG C 6 94 ODI 20 Olc -0.08 Bobbin SG C 7 10 PVN 07H +31.58 Bobbin i SG C 7 11 DSI O1H +0.06 Bobbin SG C MAI O1H +0.03 MRPC 9R DSI's 'l SG C 7 19 DSI O1H +0.00 Bobbin SG C 7 20 DSI 01H +0.06 Bobbin SG C ODI 44 02H -0.12 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's 4 SG C 7 22 DSI O1H +0.09 Bobbin SG C ODI 31 02H -0.06 Bobbin SG C MAI O1H -0.01 MRPC 9R DSI's SG C 7 46 DSI 03H +0.05 Bobbin SG C 7 47 DSI 02H +0.11 Bobbin SG C ODI' 17 01H +0.08 Bobbin SG C ODI-62 03H -0.08 Bobbin SG C 7 68 DSI O1H -0.03 Bobbin SG C 7 90 DSI 02H +0.00 Bobbin SG C 7 91 DSI O1H -0.08 Bobbin SG C 7 92 DSI 03H +0.03 Bobbin SG C 7 94 DSI 03H +0.00 Bobbin SG C 8 22 DNT TSH +0.00 Bobbin SG C 9 8 DSI O1H +0.06 Bobbin SG C 9 10 DSI O1H +0.06 Bobbin SG C DSI 02H -0.06 Bobbin SG C DSI 03H -0.03 Bobbin SG C 9 34 ODI 23 TSH +0.64 Bobbin SG C 9 93 ODI 34 Olc -0.08 Bobbin SG C 10 48 DSI O1H +0.12 Bobbin SG C 10 56 DSI O1H +0.15 Bobbin SG C 10 66 DSI O1H -+0.06 Bobbin SG C 10 67 DSI-O1H -0.06 Bobbin SG C 10 69 DSI O1H +0.00 Bobbin SG C SAI O1H +0.12. MRPC 9R DSI's SG C 10 93 ODI 12 Olc -0.05 Bobbin SG C 12 47 PVN 01C +1.08 Bobbin SG C 12 66 VOL TSH -0.29 MRPC TSH Wextex-SG C 12 71 VOL TSH -0.13 MnPC TSH Wextex SG C 12 93 ODI 37 Olc -0.11 Bobbin SG C 13 27 ODI 38 TSH +1.36 Bobbin SG C 13 32 ODI 58 TSH +2.63 Bobbin SG C 13 33 ODI 63 TSH +2.64 Bobbin SG C 13 36 ODI 16 TSH +1.84 Bobbin SG C 13 92 ODI 15 Olc +0.00 Bobbin SG C 14 30 ODI-40 TSH +2.30 Bobbin SG C 14 37 ODI 22 TSH +2.01 Bobbin SG C 14 '89 DSI 07H +0.03 Bobbin SC C 15 4 ODI 26 02C +0.03 Bobbin R 'J SG C 15 52 DSI O1H +0.00 Bobbin l y e

BWNS'TUBAN II (Version 1.0) 10/22/1993 14:25:31 Beaver-Valley Unit 1 SG C I 4/93 RFO ~**************** STEAM GENERATOR C (RC-E-1C) 9R INDICATIONS GEM ROW COL IND %TW LOCATION TEST TYPE FJ C 15 53 DSI O1H +0.03 Bobbin SG C 15 58 DSI O1H +0.06 Bobbin SG C 15 61 DSI O1H +0.09 Bobbin SG C 15 62 DSI O1H +0.00 Bobbin SG C DSI 02H -0.09 Bobbin SG C DSI 03H +0.03 Bobbin SG C 15 63 DSI O1H +0.18 Bobbin SG C DSI 03H +0.12 Bobbin SG C 15 91 ODI 38 Olc -0.11 Bobbin SG C 16 4 ODI 18 02C +0.00 Bobbin SG C 16 30 ODI 22 TSH +1.50 Bobbin SG C 16 41 VOL TSH -0.22 MRPC TSH Wextex SG C 16 49 DSI OIH +0.15 Bobbin-SG C DSI 02H +0.03 Bobbin i SG C SAI 02H +0.00 MRPC 9R DSI's SG C 16 90 ODI 32 Olc -0.11 Bobbin SG C 17 5 ODI 36 02C +0.03 Bobbin SG C ODI 58 Olc +0.00 Bobbin SG C 17 16 DSI O1H -0.03 Bobbin SG C 17 85 DSI 02H -0.08 Bobbin SG C 17 89 ODI 25 Olc -0.24 Bobbin SG C 18 19 DSI O1H +0.06 Bobbin SG C DSI 02H -0.09 Bobbin SG C DSI 03H -0.06 Bobbin SG C 18 36 DSI O1H +0.06 Bobbin SG C 18 39 DSI 02H +0.00 Bobbin SG C 18 90 ODI 30 Olc -0.19 Bobbin SG C SAI O1H +0.01 MRPC BR DSI's SG C 19 57 DSI O1H +0.09 Bobbin SG C 19 90 ODI 22 Olc -0.21 Bobbin SG C 20 33 DSI O1H +0.09 Bobbin SG C SAI. 01H +0.00 MRPC 9R DSI's SG C 20 34 DSI O1H +0.09 Bobbin SG C DSI 02H +0.03 Bobbin SG C 20 44 DSI O1H -0.06 Bobbin i SG C 20 45 ODI 48 01H -0.06 Bobbin SG C 20 75 DSI O1H +0.09 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 21 33 DSI 02H +0.00 Bobbin I SG C SAI 02H +0.00 MRPC 9R DSI's SG C 21 42 DSI O1H +0.12 Bobbin SG C 23 9 DSI 02H +0.15 Bobbin SG C 23 10 DSI 01H +0.00 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's i SG C 23 12 DSI O1H -0.03 Bobbin SG C SAI O1H +0.00-MRPC 8R DSI's SG C 23 42 DSI O1H +0.12 Bobbin SG C DSI 02H +0.03 Bobbin-SG C 23 50 DSI O1H +0.09 Bobbin SG C SAI 01H +0.00 MRPC 9R DSI's t SG C 23 51 DSI 01H +0.06 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 23 53 DSI O1H +0.12 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 23 63 DSI O1H +0.09 Bobbin SG C 23 65 DSI 02H -0.06 Bobbin SG C SAI 02H -0.12 MRPC 9R DSI's SG C 23 73 DSI O1H +0.09 Bobbin SG C 24 10 DSI O1H +0.00 Bobbin SG C SAI O1H -0.04 MRPC 9R DSI's SG C 24 13 DSI O1H -0.03 Bobbin SG C 24 21 ODI 34 O1H +0.03 Bobbin SG C 24 25 ODI 18 AV3 +0.00 Bobbin SG C 24 27 ODI 25 AV2 +0.00 Bobbin-SG C 24 31 DSI O1H +0.00 Bobbin t i a

10/22/1993 14:25:31 (Version 1.0) ley Unit BWNS TUBAN II Beaver Val 1 j SG C 4/93 RFO ) j e Page 4 of 9 STEAM GENERATOR C (RC-E-1C) 9R INDICATIONS GEN-ROW COL IND %TW LOCATION TEST TYPE SG C 24 34 DSI O1H -0.03 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 24 45 DSI O1H +0.03 Bobbin i SG C 24 65 DSI O1H +0.06 Bobbin -t SG C SAI O1H +0.00 MRPC 9R DSI's SG C 24 69 DSI O1H +0.03 Bobbin l SG C 24 86 ODI 18 Olc -0.19 Bobbin e SG C 25 12 DSI O1H +0.03 Bobbin SG C DSI-02H -0.03 Bobbin SG C SAI O1H -0.17 MRPC 9R DSI's SG C SAI -02H +0.01 MRPC 9R DSI's SG C 25 22 DSI O1H +0.00 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 25 25 DSI O1H +0.06 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 25 27 DSI O1H +0.03 Bobbin SG C SAI 01H +0.00 MRPC 9R DSI's SG C 25 28 ODI 57 01H +0.00 Bobbin SG C 25 30 DSI O1H +0.00 Bobbin SG C SAI 01H +0.00 MRPC 9R DSI's SG C 25 31 DSI O1H +0.06 Bobbin SG C 25 32 DSI O1H +0.00 Bobbin ~> SG C SAI O1H +0.00 MRPC 9R DSIs' SG C 25 38 DSI O1H +0.09 Bobbin SG C 25 45 DSI O1H +0.09 Bobbin SG C 25 84 ODI 49 Olc -0.18 Bobbin' SG C 25 86 ODI 35 01C -0.16 Bobbin SG C 26 19 DSI O1H +0.00 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 26 20 DSI O1H -0.03 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's-SG C 26 25 ODI 48 O1H +0.00 Bobbin SG C 26 26 ODI 80 01H +0.09 Bobbin L SG C 26 29 DSI O1H +0.00 Bobbin l SG C 26 31 DSI O1H +0.06 Bobbin SG C 26 33 DSI 02H +0.00 Bobbin SG C SAI 02H +0.00 MRPC 9R DSI's SG C 26 35 DSI 02H +0.06 Bobbin SG C 26 36 DSI O2H +0.00 Bobbin t SG C 26 38 DSI O1H +0.09 Bobbin SG C 26 42 DSI 02H -0.06 Bobbin SG C SAI 02H- +0.00 MRPC 9R DSI's SG C 26 58 DSI 02H -0.03 Bobbin SG C SAI TSH +0.16 MRPC TSH Wextex SG C 26 62 DNT 04C +32.32 Bobbin SG C DNT TSC +47.23 Bobbin SG C 26 67 DSI 02H +0.03 Bobbin SG C 26 70 DSI 02H +0.03 Bobbin SG C 26 84 ODI 22 Olc -0.12 Bobbin SG C 27 16 DSI 02H -0.06 Bobbin SG C 27 26 ODI 30 AV2 +0.00 Bobbin SG C 27 41 DSI O1H +0.14 Bobbin SG C SAI O1H +0.00 MRPC 8R DSI's SG C 27 44 DSI ~01H +0.06 Bobbin l SG C 27 45 DSI O1H +0.03 Bobbin i SG C DSI 02H -0.06 Bobbin SG C SAI O1H +0.00 MRPC BR DSI's SG C 27 51 DSI O1H +0.06 Bobbin SG C 27 63 DSI 02H +0.09 Bobbin SG C SAI 02H +0.01 MRPC 9R DSI's SG C 27 83 ODI 34 01C -0.18 Bobbin SG C 28 21 DSI O1H +0.00 Bobbin I SG C DSI 02H -0.03 Bobbin SG C SAI . 01h2 +0.00 MRPC BR DSI's SG C SAI 02H +0.00 MRPC 9R DSI's i l t

i BWNS TUBAN II (Version 1.0) 10/22/1993 14:25:31 Beaver Valley Unit 1 SG C 4/93 RTO Page 5 of 9 STEAM GENERATOR C (RC-E-1C) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C 28 23 ODI -56 O1H +0.03 Bobbin SG C 28 25 DSI O1H +0.00 Bobbin SG C SAI O1H +0.00 MRPC SR DSI's SG C 28 27 ODI 51 01H +0.00 Bobbin SG C 28 28 DSI O1H +0.12 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 28 29 DSI O1H +0.15 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C 28 36 ODI 43 O1H +0.23 Bobbin i SG C 28 50 ODI 59 O1H +0.03 Bobbin + SG C 28 62 ODI 70 03H -0.06 Bobbin SG C 28 83 ODI 32 Olc -0.21 Bobbin SG C 29 15 ODI 18 Olc -0.18 Bobbin SG C 29 22 DSI O1H +0.00 Bobbin SG C DSI 02H +0.03 Bobbin i' SG C MAI O1H -0.05 MRPC 9R DSI's SG C MAI 02H +0.00 MRPC 9R DSI's SG C 29 27 DSI O1H +0.06 Bobbin SG C SAI O1H +0.00 MRPC BR DSI's SG C 29 28 DSI O1H +0.09 Bobbin SG C SAI 01H +0.00 MRPC BR DSI's SG C 29 36 DSI O1H +0.00 Bobbin i SG C SAI O1H +0.00 MRPC 9R DSI's SG C 29 40 DSI O1H +0.09 -Bobbin l SG C 29 46 ODI 23 AV1 +0.00 Bobbin i SG C ODI 24 AV4 +0.00 Bobbin SG C ODI 32 AV3 +0.00 Bobbin SG C ODI 35 AV2 +0.00 Bobbin i SG C 29 49 DSI 02H +0.00 Bobbin SG C SAI 02H +0.00 MRPC 9R DSI's SG C 29 53 DSI O1H +0.03 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 29 65 DSI O2H +0.06 Bobbin SG C SAI O2H +0.02 MRPC 9R DSI's SG C 29 77 ODI 62 02H +0.12 Bobbin SG C 29 82 ODI 35 02C +0.09 Bobbin SG C ODI 50 Olc -0.06 Bobbin SG C 29 84 ODI 36 Olc -0.13 Bobbin SG C 30 14 ODI 39 02C -0.15 Bobbin SG C 30 15 DNT TSH +15.02 Bobbin SG C DNT TSH +14.11 Bobbin SG C ODI 35 TSH +2.42 Bobbin SG C VOL TSH +1.61 MRPC TSH Wextex SG C 30 36 DSI O1H -0.09 Bobbin SG C DSI 02H -0.09 Bobbin SG C 30 38 DSI O1H +0.09 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 30 44 DSI O1H +0.21 Bobbin SG C 30 53 DSI O1H +0.06 Bobbin SG C SAI O1H +0.03 MRPC 9R DSI's SG C 30 61 DSI 02H +0.00 Bobbin SG C 30 81 ODI 40 Olc -0.09 Bobbin SG C 30 82 ODI 40 OIC -0.08 Bobbin SG C 30 83 ODI 29 Olc -0.14 Bobbin i SG C 31 17 DSI O1H +0.06 Bobbin SG C 31 19 ODI .~44 01H +0.17 Bobbin SG C SAI O1H +0.00 MRPC BR DSI's SG C 31 22 DSI O1H +0.06 Bobbin l SG C 31 26 DSI O1H +0.00 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's [ SG C 31 27 DSI O1H +0.06 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 31 28 DSI O1H +0.06 Bobbin 4 SG C SAI O1H +0.00 MRPC 9R DSI's SG C 31 38 DSI-O1H +0.09 Bobbin

~ (Version 1.0) ley Unit 1 10/22/1993 14:25:31 BWNS TUBAN II Beaver Val SG C 4/93 RFO Page 6 of 9 STEAM GENERATOR C (RC-E-1C) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C 31 39 DSI O1H +0.00 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 31 40 DS1 O1H +0.00 Bobbin I SG C SAI O1H +0.00 MRPC 9R DSI's SG C 31 43 DSI O1H +0.23 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 31 45 DSI O1H +0.03 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 31 50 ODI 73 02H -0.06 Bobbin SG C 31 62 DSI 03H +0.03 Bobbin SG C 32 18 DSI O1H +0.06 Bobbin SG C 32 24 DSI O1H +0.06 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C 32 25 DSI O1H +0.09 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's e SG C 32 27 DSI O1H +0.00 Bobbin i SG C SAI O1H +0.00 MRPC BR DSI's SG C 32 33 DSI O1H +0.03 Bobbin SG C 32 34 DSI 02H -0.09 Bobbin SG C 32 36 DSI O1H +0.03 Bobbin SG C DSI 02H +0.03 Bobbin SG C MAI O1H +0.00 .MRPC 9R DSI's SG C 32 37 DSI O1H +0.14 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 32 39 DSI O2H +0.00 Bobbin i SG C 32 41 DSI O1H +0.06 Bobbin ~ SG C 32 42 DSI O1H +0.12 Bobbin i SG C 32 43 DSI. O1H +0.12 Bobbin SG C DSI 02H +0.12 Bobbin SG C SAI O1H -0.01 MRPC 9R DSI's SG C SAI 02H +0.00 MRPC 9R DSI's t SG C 32 46 DSI O1H +0.00 Bobbin SG C SAI O1H +0.00 MRPC 8R DSI's SG C 32 50 ODI 40 01H +0.09 Bobbin SG C ODI 73 02H -0.09 Bobbin + SG C 32 56 DSI O1H -0.03 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 33 18 ODI 35 01C -0.21 Bobbin SG C 33 26 DSI O1H +0.06 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 33 27 DSI O1H +0.06 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 33 30 DSI O1H +0.06 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C 33 31 DSI O1H +0.06 Bobbin i SG C MAI O1H +0.00 MRPC 9R DSI's SG C 33 36 DSI 01H +0.06 Bobbin SG C 33 79 ODI 31 O1H +0.27 Bobbin SG C 34 26 DSI 02H +0.03 Bobbin SG C SAI O2H +0.04 MRPC 9R DSI's SG C 34 28 DSI O1H +0.03 Bobbin SG C SAI O1H +0.00 MRPC BR DSI's SG C 34 29 DSI O1H +0.06 Bobbin SG C DSI 02H +0.03 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C SAI 02H +0.00 MRPC 9R DSI's SG C 34 30 DSI O1H +0.06 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C 34 31 DSI O1H +0.03 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C 34 32 DSI O1H +0.00 Bobbin SG C 34 34 DSI O1H +0.03 Bobbin SG C DSI 02H +0.06 Bobbin SG C SAI 02H -0.01 MRPC 9R DSI's SG C 34 40 DSI O1H +0.09 Bobbin i

BWNS TUBAN II (Version 1.0) 10/22/1993 14:25:31 Beaver Valley Unit 1 SG C 4/93 RFO Page 7 of 9' STEAM GENERATOR C gRC-E-1C) 9R INDICATIONS GEN ROW-COL IND %TW LOCATION TEST TYPE SG C DSI 03H +0.03 Bobbin SG C 34 43 DSI O1H +0.09 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C 34 50 ODI 45 02H +0.00 Bobbin SG C 34 56 ODI 70 O1H +0.09 Bobbin SG C 34 63 DSI O1H +0.03 Bobbin SG C PVN 01H +0.00 MRPC 8R DSI's SG C 34 77 ODI 29 OIC -0.26 Bobbin SG C 34 78 ODI 27 02H +0.27 Bobbin SG C ODI 29 OSC -0.15 Bobbin SG C ODI 43 Olc -0.06 Bobbin SG C 34 79 ODI 25 01C -0.03 Bobbin SG C ODI 31 02C -0.03 Bobbin SG C 35 20 DSI O1H +0.21 Bobbin SG C ODI ' 27 02H +0.00 Bobbin SG C 35 24 DSI O1H +0.06 ' Bobbin SG C DSI 02H +0.06 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C MAI 02H +0.00 MRPC 9R DSI's SG C 35 28 DSI O1H +0.03 Bobbin SG C DSI 04H +0.03 Bobbin SG C SAI O1H +0.00 MRPC 8R DSI's SG C 35 30 DSI O1H +0.00 Bobbin SG C SAI O1H +0.00 MRPC BR DSI's SG C 35 34 DSI O1H +0.03 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C 35 35 DSI 02H ~ -0.06 Bobbin SG C 35 36 DSI 02H -0.03 Bobbin SG C SAI 02H +0.00 MRPC 9R DSI's SG C 35 40 DSI O1H +0.06 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 35 43 DSI O1H +0.06 Bobbin SG C 35 44 DSI O1H +0.09 Bobbin SG C 35 45 DSI O1H +0.09 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 35 47 ODI 33 01H +0.15 Bobbin SG C 35 53 DSI O1H +0.12 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C 35 61 DSI 02H +0.03 Bobbin SG C 35 78 ODI 24 04C -0.27 Bobbin SG C 36 20 DSI 07H +0.03 Bobbin SG C 36 22 DSI 02H +0.03 Bobbin-SG C MAI 02H +0.00 MRPC 9R DSI's SG C 36 28 DSI O1H +0.09 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 36 31 DSI O1H +0.06 Bobbin SG C 36 35 DSI 01H +0.15 Bobbin SG C DSI 02H +0.09 Bobbin SG C 36 36 DSI 03H +0.06 Bobbin SG C ODI 59 02H -0.03 Bobbin SG C SAI 03H +0.00 MRPC 9R DSI's SG C 36 41 DSI O1H +0.12 Bobbin SG C DSI 03H +0.09 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 36 42 DSI 03H -0.09 Bobbin SG C 36 43 DSI O1H +0.06 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 36 45 DSI O1H +0.15 Bobbin SG C DSI 02H -0.03 Bobbin SG C SAI O1H +0.16 MRPC 9R DSI's SG C SAI 02H +0.00 MRPC 9R DSI's SG C 36 47 ODI 23 AV2 -0.29 Bobbin SG C 36 50 DSI 03H +0.00 Bobbin SG C SAI 03H +0.00 MRPC 9R DSI's SG C 37 19 ODI 34 01C- -0.29 Bobbin

[ BWNS TUBAN II (Version 1.0) 10/22/1993'14:25:31 Beaver Valley Unit 1 SG C 4/93 RFO t i Page 8 of 9 STEAH GENERATOR C (RC-E-IC) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE I SG C 37 25 DSI O1H +0.00 Bobbin SG C 37 26 DSI O1H +0.00 Bobbin ? SG C SAI O1H +0.00 MRPC 9R DSI's .i SG C 37 37 DSI O1H +0.09 Bobbin-SG C SAI O1H +0.00 MRPC 9R DSI's SG C 37 41 DSI O1H +0.12 Bobbin i SG C SAI O1H +0.00 MRPC 9R DSI's SG C 37 42 DSI O1H +0.12 Bobbin 6 SG C SAI O1H +0.00 MRPC 9R DSI's SG C 37 62 ODI 47 02H +0.03 Bobbin SG C 37 74 ODI 32 Olc -0.12 Bobbin SG C 38 23 ODI 38 Olc -0.26 Bobbin c SG C 38 27 DSI 02H +0.03 Bobbin l SG C 38 30 DSI O1H +0.06 Bobbin i SG C 38 31 DSI O1H +0.06 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 38 34 DSI O1H +0.00 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 38 37 DSI 02H +0.12 Bobbin 7 SG C MAI 02H +0.00 MRPC BR DSI's SG C 38 41 DSI OIH +0.06 Bobbin SG C SAI O1H +0.00 MRPC 9R DSI's SG C 38 47 DSI OIH -0.09 Bobbin SG C S Al - O1H +0.00 MRPC 9R DSI's SG C 38 59 DSI O1H +0.03 Bobbin SG C SAI OIH +0.00 MRPC 9R DSI's SG C 38 62 DSI O1H +0.17 Bobbin SG C MAI O1H +0.10 MRPC 9R DSI's SG C 38-66 DSI 03H +0.00 Bobbin SG C ODI 13 04H +0.00 Bobbin SG C MAI 03H +0.01 MRPC 9R DSI's SG C 39' 27 ODI 25 OIC -0.21 Bobbin SG C 39 29 DSI O1H -0.03 Bobbin' SG C MAI O1H +0.00 MRPC 9R DSI's h SG C 39 30 DSI O1H +0.06 Bobbin SG C 39 33 DSI O1H +0.12 Bobbin i SG C SAI O1H +0.02 MRPC BR DSI's l SG C 39 35 PVN 02C +50.03 Bobbin i SG C 39 37 DSI O1H +0.06 Bobbin SG C 39 40 DSI O1H +0.06 Bobbin i SG C SAI O1H +0.00 MRPC 9R DSI's SG C-39 58 ODI 26 AV4 +0.00 Bobbin r SG C 40 25 ODI 39 Olc -0.32 Bobbin i SG C 40 27 DSI O2H +0.15 Bobbin l SG C SAI 02H +0.00 MRPC 9R DSI's SG C 40 39 DSI O1H +0.09 Bobbin i SG C SAI O1H +0.00 MRPC 9R DSI's SG C 40 50 ODI 22 AV2 +0.00 Bobbin SG C 40 52 ODI -18 AV3 +0.00 Bobbin SG C ODI 27 AV4 +0.00 Bobbin SG C 40 66 DSI 02H +0.00 Bobbin i SG C 41 26 DSI O1H +0.15-Bobbin SG C ODI 27 04C +0.12 Bobbin SG C 41 27 ODI 49 Olc -0.12 Bobbin SG C 41 29 DSI 04H +0.03 Bobbin SG C ODI 35 04C +0.06 Bobbin SG C 41 48 DSI 02H +0.03 Bobbin SG C 41 56 DSI 03H +0.06 Bobbin SG C 41 P3 DSI 02H . +0.00 Bobbin SG C SAI 02H -0.01 MRPC 9R DSI's SG C 41 2DI 23 OIC -0.26 Bobbin l SG C 42 DI 27 04C +0.12 Bobbin SG C 42-34 JDI 20 Olc -0.18 Bobbin SG C 42 44 ODI 21 03H +2.28 Bobbin SG C 42 53 ODI 14 02C -0.18 Bobbin .( a

.BWNS TUBAN II (Version 1.0) 10/22/1993 14:25:31 Beaver Valley Unit 1 SG C 4/93 RFO Page 9 of 9 STEAH GENERATOR C (RC-E-1C) 9R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C 42 63 ODI 48 OIC -0.20 Bobbin SG C 43 30 ODI 35 04C -0.06 Bobbin SG C 43 37 DSI O1H +0.21 Bobbin SG C SAI O1H +0.16 MRPC 9R DSI's SG C 43 45 DSI 02H -0.06 Bobbin SG C DSI 05H +0.03 Bobbin SG C 43 48 DSI O1H +0.09 Bobbin SG C 44 33 DNT 07H +137.57 Bobbin SG C ODI 12 04C -0.27 Bobbin SG C ODI 35 03C -0.27 Bobbin SG C 44 35 ODI 12 04C -0.09 Bobbin SG C 44 36 ODI 26 03C +0.09 Bobbin SG C 44 39 ODI 36 03C -0.21 Bobbin SG C 44 47 ODI 43 02C -0.18 Bobbin SG C 44 49 ODI 25 03C +0.09 Bobbin SG C 44 62 ODI 29 Olc -0.14 Bobbin SG C 45 36 ODI 29 04C +0.18 Bobbin SG C 45 37 ODI 29 04C +0.12 Bobbin SG C 45 39 ODI 22 04C +0.15 Bobbin SG C 46 46 ODI 26 03C +0.15 Bobbin Total Indications Found = 540 Total Tubes Found = 355

i ) BWNS TUBAN II (Version'1.0) 10/22/1993 11:07:58 Beaver Valley Unit 1 i SG C i ') 4/93 RFO ~**************** 1 1 Page 1 of 3 1 STEAM GENERATOR C (RC-E-1C) 9R PLUGGED TUBES i GEN ROW COL IND %TW LOCATION TEST TYPE SG C 1 1 ODI 43 TSH +17.64 Bobbin SG C SAI 07H +3.72 MRPC U-Bend' SG C 1 2 ODI 47 TSH +17.61 Bobbin SG C SAI 07H +3.79 MRPC U-Bend SG C 1 7 SAI 07H +3.86 MRPC U-Bend SG C 1 92 SAI 02H +0.00 MRPC 9R DSI's SG C 2 21 MAI O1H +0.00 MRPC 9R DSI's SG C 2 22 SAI O1H +0.00 MRPC 9R DSI's SG C 2 66 MAI O1H +0.03 MRPC 9R DSI's SG C 2 92 SAI 02H +0.00 MRPC 9R DSI's SG C 5 28 SAI O1H +0.09 MRPC 9R DSI'm SG C 5 60 SAI O1H +0.01 MRPC 8R DSI's SG C 6 33 SAI O1H -0.05 MRPC 9R DSI's SG C 6 44 SAI O1H. -0.07 MRPC BR DSI's SG C 7 Il MAI O1H +0.03 MRPC 9R DSI's + SG C 7 20 ODI 44 02H -0.12 Bobbin SG C MAI O1H +0.00 MRPC 9R DSI's SG C 7 22 ODI 31 02H -0.06 Bobbin SG C MAI O1H -0.01 MRPC 9R D'3I's SG C 7 47 ODI 17 O1H +0.08 Bobbin SG C ODI 62 03H -0.08 Bobbin SG C 10 69 SAI O1H +0.12 MRPC 9R ESI's SG C 12 66 VOL TSH -0.29 MRPC TSH Wextex SG C 12 71 VOL TSH -0.13 MRPC TSH Wextex SG C 13 32 ODI 58 TSH +2.63 Bobbin SG C 13 33 ODI 63 TSH +2.64 Bobbin SG C 14-30 ODI 40 TSH +2.30 Bobbin. SG C 16 41 VOL TSH -0.22 MRPC TfH Wextex SG C 16 49 SAI 02H +0.00 MRPC 9A DSI's SG C 17 5 ODI 36 02C +0.03 Bobbi.s SG C-ODI 58 Olc +0.00 Bobbin SG C 28 90 ODI -30 OIC -0.19 Bobbin SG C SAI O1H +0.01 MRPC BR DSI's SG C 20 33 SAI O1H +0.00 MRPC 9R DSI's SG C 20 45 ODI 48 O1H -0.06 Bobbin SG C 20 75 SAI O1H +0.00 MRPC 9R DSI's SG C 21 33 SAI 02H +0.00 MRPC 9R DSI's SG C 23 10 MAI O1H +0.00 MRPC 9R DSI's SG C 23 12 SAI O1H +0.00 MRPC BR DSI's SG C 23 50 SAI O1H +0.00 MRPC 9R DSI's SG C 23 51 SAI O1H +0.00 MRPC 9R DSI's SG C 23 53 SAI O1H +0.00 MRPC 9R DSI's SG C 23 65 SAI 02H -0.12 MRPC 9R DSI's SG C 24 10 SAI O1H -0.04 MRPC 9R DSI's SG C 24 34 SAI O1H +0.00 MRPC 9R DSI's SG C 24 65 SAI O1H +0.00 MRPC 9R DSI's SG C 25 12 SAI O1H -0.17 MRPC 9R DSI's SG C SAI 02H +0 01 MRPC 9R DSI's SG C 25 22 SAI O1H +0.00 MRPC 9R DSI's SG C 25 25 SAI O1H +0.00 MRPC 9R DSI's SG C 25 27 SAI O1H +0.00 MRPC 9R DSI's SG C 25 28 ODI 57 O1H +0.00 Bobbin SG C 25 30 SAI O1H +0.00-MRPC 9R DSI's SG C-25 32 SAI O1H +0.00 MRPC 9R DSI's SG C 25 84 ODI 49 Olc -0.18 Bobbin SG C 26 19 SAI O1H +0.00 MRPC 9R DSI's SG C 26 20 SAI O1H +0.00 MRPC 9R DSI's SG C 26 25 ODI 48 01H +0.00 Bobbin SG C 26 26 ODI 80 O1H +0.09 Bobbin SG C 26 33 SAI 02H +0.00 MRPC 9R DSI's SG C 26 42 SAI 02H +0.00 MRPC 9R DSI's SG C 26 58 SAI TSH +0.16 MRPC TSH Wextex SG C 27 41 SAI O1H +0.00 MRPC 8R DSI's .SG C 27 .45 SAI. O1H +0.00 MRPC BR DSI's SG C 27' 63 SAI O2H +0.01 MRPC 9R DSI's 1

BWNS TUBAN II (Version 1.0) 10/22/1993 11:07:58 Beaver Valley Unit 1 SG C 4/93 RFO i Page 2 of 3 STEAM GENERATOR C (RC-E-1C) 9R PLUGGED TUBES i GEN ROW COL IND %TW LOCATION TEST. TYPE SG C 28 21 SAI O1H +0.00 MRPC BR DSI's SG C SAI 02H +0.00 .MRPC 9R DSI's SG C 28 23 ODI 56 O1H +0.03 Bobbin SG C 28 25 SAI O1H +0.00 MRPC 9R DSI's SG C 28 27 ODI 51 O1H +0.00 Bobbin SG C 28 28 SAI O1H +0.00 MRPC 9R DSI's SG C 28 29 MAI O1H +0.00 MRPC 9R DSI's SG C 28 36 ODI 43 O1H +0.23 Bobbin SG C 28 50 ODI 59 01H +0.03 Bobbin SG C 28 62 ODI 70 03H -0.06 Bobbin SG C 29 22 MAI O1H -0.05 MRPC 9R DSI's SG C MAI O2H +0.00 MRPC 9R DSI's SG C 29 27 SAI O1H +0.00 MRPC BR DSI's i SG C 29 28 SAI O1H +0.00 MRPC 8R DSI's SG C 29 36 SAI O1H +0.00 MRPC 9R DSI's a SG C 29 49 SAI 02H +0.00 MRPC 9R DSI's SG C 29 53 SAI O1H +0.00 MRPC 9R DSI's SG C 29 65 SAI 02H +0.02 MRPC 9R DSI's SG C 29 77 ODI 62 02H +0.12 Bobbin SG C 29 82 ODI 35 02C +0.09 Bobbin SG C ODI 50 Olc -0.06 Bobbin SG C 30 15 ODI 35 TSH +2.42 Bobbin i SG C VOL TSH +1.61 MRPC TSH Wextex SG C 30 38 SAI O1H +0.00 MRPC 9R DSI's SG C 30 53 SAI O1H +0.03 MRPC 9R DSI's. SG C 30 81 ODI 40 Olc -0.09 Bobbin SG C 30 82 ODI 40 Olc -0.08 Bobbin SG C 31 19 ODI 34 O1H +0.17 Bobbin SG C SAI O1H +0.00 MRPC BR DSI's SG C 31 26 SAI O1H +0.00 MRPC 9R DSI's-SG C 31 27 SAI O1H +0.00 MRPC 9R'DSI's SG C 31 28 SAI O1H +0.00 MRPC 9R DSI's 5 SG C 31 39 SAI 01H +0.00 MRPC 9R DSI's SG C 31 40 SAI O1H +0.00 MRPC 9R DSI's SG C 31 43 SAI O1H +0.00 MRPC 9R DSI's 'i SG C 31 45 SAI O1H +0.00 MRPC 9R DSI's SG C 31 50 ODI 73 02H -0.06 Bobbin SG C 32 24 MAI O1H +0.00 MRPC 9R DSI's SG C 32 25 SAI O1H +0.00 MRPC 9R DSI's SG C 32 27 SAI O1H +0.00 MRPC BR DSI's SG C 32 36 MAI O1H +0.00 MRPC 9R DSI's SG C 32 37 SAI O1H +0.00 MRPC 9R DSI's SG C 32 43 SAI O1H -0.01 MRPC 9R DSI's SG C SAI 02H +0.00 MRPC 9R DSI's SG C 32 46 SAI O1H +0.00 MRPC BR DSI's SG C 32 50 ODI 40 O1H +0.09 Bobbin SG C ODI 73 02H -0.09 Bobbin SG C 32 56 SAI O1H +0.00 MRPC 9R DSI's SG C 33 26 SAI O1H +0.00 MRPC 9R DSI's s SG C 33 27 SAI O1H +0.00 MRPC 9R DSI's SG C 33 30 MAI O1H +0.00 MRPC 9R DSI's SG C' 33 31 MAI 01H' +0.00 MRPC 9R'DSI's SG C 34 26 SAI 02H +0.04 MRPC 9R DSI's SG C 34 28 SAI O1H +0.00 MRPC BR DSI's SG C 34 29 SAI O1H +0.00 MRPC 9R DSI's SG C SAI 02H +0.00 MRPC 9R DSI's SG C 34 30 MAI O1H +0.0; MRPC 9R DSI's SG C 34 31 MAI O1H +0.00 MRPC 9R DSI's SG C 34 34 SAI 02H -0.01 MRPC 9R DSI's SG C 34 43 MAI O1H +0.00 MRPC 9R DSI's SG C 34 50 ODI 45 02H +0.00 Bobbin SG C 34 56 ODI 70 O1H +0.09 Bobbin t SG C 34 78 ODI 27 02H +0.27 Bobbin I SG C ODI 29 05C -0.15 Bobbin SG C ODI 43 01C -0.06 Bobbin

E BWNS'TUBAN II (Versio'n 1.0) 10/22/1993'11:07:58 i / Beaver Valley Unit 1 j SG C + 4/93 RFO e,*e************ 1 i i Page 3 of 3-STEAM GENERATOR C (RC-E-1C) 9R PLUGGED TUBES GEN ROW COL IND %TW LOCATION TEST TYPE i SG C 35 24 MAI O1H +0.00 MRPC 9R DSI's SG C MAI 02H +0.00 MRPC 9R DSI's SG C 35 28 SAI O1H +0.00 MRPC BR DSI's i SG C 35 30 SAI O1H +0.00 MRPC BR DSI's i SG C 35 34 MAI O1H +0.00 MRPC 9R DSI's SG C 35 36 SAI O2H +0.00 MRPC 9R DSI's SG C 35 40 SAI O1H +0.00 MRPC 9R DSI's i' SG C 35 45 SAI O1H +0.00 MRPC 9R DSI's SG C '35 53 MAI O1H +0.00 MRPC 9R DSI's SG C 36 22 MAI O2H +0.00 MRPC 9R DSI's -i SG.C 36 28 SAI O1H +0.00 MRPC 9R DSI's SG C 36 36 ODI 59 02H -0.03 Bobbin SG C SAI 03H +0.00 MRPC 9R DSI's i SG C 36 41 SAI O1H +0.00 MRPC 9R DSI's l SG C 36 43 SAI O1H +0.00 MRPC 9R DSI's SG C 36 45 SAI O1H +0.16 MRPC 9R DSI's SG C SAI 02H +0.00 MRPC 9R DSI's + SG C 36 50 SAI 03H +0.00 MRPC 9R DSI's i SG C 37 26 SAI O1H +0.00 MRPC 9R DSI's l SG C 37 37 SAI O1H +0.00 MRPC 9R DSI's i SG C 37 41 SAI O1H +0.00 MRPC 9R DSI's t SG C 37 42 SAI O1H +0.00 MRPC 9R DSI's SG C 37 62 ODI 47 02H +0.03 Bobbin l SG C 38 31.SAI O1H +0.00 MRPC 9R DSI's SG C 38 34 SAI 01H +0.00 MRPC 9R.DSI's SG C 38 37'MAI 02H +0.00 MRPC BR DSI's SG C 38 41 SAI O1H +0.00 MRPC 9R DSI's SG C 38 47 SAI' O1H +0.00 MRPC 9R DSI's s SG C 38 59 SAI O1H +0.00 MRPC 9R DSI's SG C 38 62 MAI O1H +0.10 MRPC 9R DSI's i SG C 38 66 ODI. 13 04H +0.00 Bobbin SG C MAI 03H +0.01 MRPC 9R DSI's SG C 39 29 MAI O1H +0.00 MRPC 9R DSI's SG C 39 33 SAI O1H +0.02 MRPC BR DSI's SG C 39 40 SAI O1H +0.00 MRPC 9R DSI's SG C 40 27 SAI 02H +0.00 MRPC 9R DSI's SG C 40 39 SAI O1H +0.00 MRPC 9R DSI's SG C 41 27 ODI 49 Olc -0.12 Bobbin SG C 41 63 SAI 02H -0.01 MRPC 9R DSI's SG C 42 63 ODI 48 Olc -0.20 Bobbin SG C 43 37 SAI O1H +0.16 MRPC 9R DSI's SG C 44 47 ODI 43 02C -0.18 Bobbin Total Indications Found = 172 Total Tubes Found = 150 Total Tubes in Input File = 394 l t v t 1 1 /

r

t r

ATTACHMENT 4 CNIT #2 LTH REFUELING OLTAGE STEAM GENERATOR "A" (2RCS-SG21A)

i BWNS TUBAN II (Version 1,0) ley Unit 2 10/22/1993-07:33:16 Beaver Val SG A 4R 9/93

                  • =******

l Page 1 of 18-STEAM GENERATOR A (2RCS-SG21A) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A 1 1 ADR SH +4.00 BOBBIN SG A NQI 7C +47.35 BOBBIN r SG A INF 7C +47.35 MRPC U-Bend SG A 1 3 ADR IH +7.06 BOBBIN SG A VOL IH +6.29 MRPC Special In SG A 1 4 ETL TSH +1.77 BOBBIN-SG A INF TSH +1.77 MRPC Special In l SG A 1 6 NQI 7C +47.72 BOBBIN SG A INF 7C +47.72 MRPC U-Bend SG A 1 7 NQI 7C +47.24 BOBBIN SG A INF 7C +47.24 MRPC U-Bend SG A 1 9 NQI 7C +47.05 BOBBIN SG A INF 7C +47.05 MRPC U-Bend SG A 1 10 NQI 7C +46.57 BOBBIN SG A INF 7C +46.57 MRPC U-Bend SG A 1 11 NQI 7C +47.00 BOBBIN SG A INF 7C +47.00 MRPC U-Bend SG A 1 12 NQI 7C +47.30 BOBBIN SG A INF 7C +47.30 KRPC U-Bend SG A 1 13 NQI 7C +47.61 BOBBIN SG A INF 7C +47.61 MRPC U-Bend a SG A 1 14 NQI 7C +46.83 BOBBIN SG A INF 7C +46.83 MRPC U-Bend 't SG A 1 15 NQI 7C +46.79 BOBBIN SG A INF 7C +46.79 MRPC U-Bend SG A 1 16 NQI 7C +46.63 BOBBIN SG A INF 7C +46.63 MRPC U-Bend SG A 1 17 NQI 7C +47.79 BOBBIN. SG A INF 7C +47.79 MRPC U-Bend i SG A 1 18 NQI 7C +48.24 BOBBIN-SG A INF 7C +48.24 MRPC U-Bend l SG A 19 NQI 7C +47.20 . BOBBIN SG A INF 7C +47.20-MRPC U-Bend 3 SG A 1 20 HQI 7C +48.79 BOBBIN SG A NQI BH -0.92 BOBBIN SG A INF 7C +48.79 MRPC U-Bend SG A INF 8H -0.92 MRPC U-Bend SG A INF EH -0.92 MRPC Special In SG A 1 25 NQI 7C +48.22 BOBBIN SG A INF 7C +48.22 MRPC U-Bend SG A 1 26 NQI 7C +48.81 BOBBIN SG A INF 7C +48.81 MRPC U-Bend SG A 1 27 NQI 7C +49.19 BOBBIN SG A INF 7C +49.19 MRPC U-Bend SG A 1 29 NQI 7C +48.96 BOBBIN SG A INF 7C +48.96 MRPC U-Bend SG A 1 30 NOI 7C +48.71 BOBBIN SG A INF 7C +48.71 MRPC U-Bend SG A 1 33 NQI 7C +48.64 BOBBIN SG A INF 7C +48.64 MRPC U-Bend SG A 1 34 NQI 7C +49.09 BOBBIN SG A INF 7C +49.09 MRPC U-Bend SG A 1 35 NQI 7C +48.64 BOBBIN SG A INF 7C +48.64 MRPC U-Bend SG A 1 36 NQI 7C +48.51 BOBBIN SG A INF 7C +48.51 MRPC U-Bend SG A 1 37 NQI 7C +49.19 BOBBIN SG A INF 7C +49.19 MRPC U-Bend. SG A 1 40 NQI 7C +48.81 BOBBIN SG A INF 7C +48.81 MRPC U-Bend-SG A 1 45 NQI 7C +47.12 BOBBIN i SG A INF 7C +47.12 MRPC U-Bend SG A INF 3H +0.00 MRPC 4R DSIs SG A 1 49 NQI 70 +47.51 BOBBIN SG A INF 7C +47.51 MRPC U-Bend-i l

  • *
  • e e '*
  • e e e e e * * * * ~

BWNS TUBAN II (Version 1.0) 10/22/1993 07:33:16 i Beaver Valley Unit 2 l SG A i '[ 4R 9/93 i Page 2 of 18 I STEAM GENERATOR A (2RCS-SG21A) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A 1 53 NQI 7C +47.07 BOBBIN SG A INF 7C +47.07 MRPC U-Bend i SG A 1 57 NQI 7C +48.49 BOBBIN i SG A INF 7C -+48.49 MRPC U-Bend SG A 1 63 NQI 7C +48.60 BOBBIN SG A INF 7C +48.60 MRPC U-Bend SG A 1 74 NQI BC +0.42 BOBBIN SG A INF SC . +0.42 MRPC U-Bend SG A 1 79 NQI-7C +47.64 BOBBIN j SG A INF 7C +47.64 MRPC U-Bend SG A 1 80 ADR 7H +32.08 BOBBIN SG A NQI 7C +47.15 BOBBIN SG A INF 7C +47.15 MRPC U-Bend SG A 1 81 NOI 7C +47.30 BOBBIN SG A INF 7C +47.30 MRPC U-Bend SG A 1 84 ADR 6H +17.25 BOBBIN i SG A VOL BH +13.13 MRPC U-Bend SG A 1 85 DTI TSC -0.15 BOBBIN t SG A INF TSC -0.15 MRPC Special In l SG A 1 91 NQI 7C +47.62 BOBBIN i SG A INF 7C +47.62 MRPC U-Bend { SG A INF 7C +47.62 MRPC U-Bend SG A 1 92 NQI 8C +0.54 BOBBIN SG A INF BC +0.54 MRPC U-Bend SG A 1 93 DNT BH +0.25 BOBBIN SG A NQI BH +0.b0 MRPC U-Bend i SG A NQI 8H +0.56 MRPC Special In f SG A 1 94 DNG 8C +1.86 BOBBIN 't' SG A INF BC +1.86 MRPC U-Bend SG A 2 1 NQI BH +1.24 BOBBIN SG A INF BH +1.24 MRPC U-Bend SG A 2 2 NQI '8H +1.41 BOBBIN SG A INF BH +1.41 MRPC U-Bend SG A 2 4 NQI BH +1.75 BOBBIN i SG A INF 8H +1.75 MRPC U-Bend SG A 2 5 NQI 8C +0.70 BOBBIN l SG A NQI 8H +0.87 BOBBIN SG A INF BC +0.70 MRPC U-Bend l SG A INF 8H 40.87 MRPC U-Bend i SG A 2 7 NQI BH +0.92 BOBBIN t SG A INF BH +0.92 MRPC U-Bend i SG A 2 10 NQI BH +1.03 BOBBIN SG A INF SH +1.03 MRPC U-Bend SG A 2 11 NQI BC +0.33 BOBBIN SG A NQI BH- +0.92 BOBBIN SG A INF BC +0.33 MRPC U-Bend SG A INF BH +0.92 MRPC U-Bend SG A 2 12 NQI BH +0.97 BOBBIN SG A INF 8H +0.97 MRPC U-Bend i SG A 2 13 NQI 8C +0.70 BOBBIN SG A NQI 8H +0.66 BOBBIN SG A INF 8C +0.70 MRPC U-Bend SG A INF BH +0.66 MRPC U-Bend SG A 2 14 INF 3H +0.00 BOBBIN SG A NQI BC +0.51 BOBBIN SG A NQI 8H +0.69 BOBBIN SG A INF BC +0.51 MRPC U-Bend- .i SG A INF 8H +0.69 MRPC:U-Bend i SG A INF 3H +0.00 MRPC 4R DSIs SG A 2 15 DSI SH -0.04 BOBBIN SG A NQI BH +0.66 BOBBIN [ SG A INF 8H +0.66 MRPC U-Bend SG A INF 5H -0.04 MRPC 4R DSIs SG A 2 16 NQI BC +0.51 BOBBIN SG A NQI BH ' +0.97 BOBBIN 4

t f BWNS TUBAN II (Version 1;0) 10/22/1993 07:33:16 ( -Beaver Valley Unit.2. 3g A f 1**************** 4R 9/93 i Page 3.of 18 l STEAM GENERATOR A (2RCS-SG21A) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE l SG A INF 8C +0.51 MRPC U-Bend i SG A INF 8H +0.97 MRPC U-Bend SG A 2 17 ADR 3H +33.98 BOBBIN SG A NQI BH +1.18 BOBBIN SG A INF 8H +1.18 MRPC U-Bend l SG A 2 18 NQI BH +0.67 BOBBIN r SG A INF 8H +0.67 MRPC U-Bend l SG A 2 19 NQI BC +0.53 BOBBIN i SG A NQI BH +1.00 BOBBIN l SG A INF BC +0.53 MRPC U-Bend SG A INF BH +1.00 'MRPC U-Bend 3 SG A 2 20 NQ1 BC +0.48 BOBBIN r SG A NQI BH +0.74 BOBBIN i SG A ETL TSC +3.24 BOBBIN .i SG A INF 8C +0.48 MRPC U-Bend i SG A INF BH +0.74 MRPC U-Bend 5 SG A INF TSC +1.24 MRPC Special In 'l SG A 2 21 NQI 8C +0.56 BOBBIN SG A NQI BH +0.53 BOBBIN SG A ETL TSH +1.68 BOBBIN' i SG A INF 8C +0.56 MRPC U-Bend i SG A INF BH +0.56 MRPC U-Bend i l SG A SAI TSH +1.51 MRPC Special In SG A 2 23 NQI BC +0.48 BOBBIN I SG A INF BC +0.48 MRPC U-Bend I SG A 2 24 NQI BH +1.10 BOBBIN-SG A INF BH +1.10 MRPC U-Bend l SG A 2 25 NQI BC +0.38 BOBBIN SG A NQI 8H +0.96 BOBBIN SG A INF BC +0.38 MRPC U-Bend l SG A INF 8H +0.96 MRPC U-Bend SG A 2 26 ADR 4H +15.26 BOBBIN I SG A NQI BH +1.04 BOBBIN i SG A INF BH +1.04 MRPC U-Bend ~ SG A 2 27 NQI BC +0.36 BOBBIN SG A NQI BH +1.25 BOBBIN SG A INF BC +0.36 MRPC U-Bend SG A INF BH +1.25 MRPC U-Bend t SG A 2 28 NQI BH +0.99 BOBBIN SG A INF 8H +0.99 MRPC U-Bend i SG A 2 29 DSI 5H +0.02 BOBBIF SG A NQI BC +0.41 BOBBIN SG A NQI BH +0.73 BOBBIN 'SG A INF BC +0.41 MRPC U-Bend SG A INF 8H +0.73 MRPC U-Bend SG A INF 5H +0.02 MRPC 4R DSIs t SG A 2 30 NQI 8C +0.33 BOBBIN SG A INF 8C +0.33 MRPC U-Bend SG A 2 31 NQI 8C +0.36 BOBBIN SG A NOI-BH

  • 1.36

' BOBBIN SG A INF BC +0.36 MRPC U-Bend SG A INF BH. +1.36 MRPC U-Bend I SG A 2 33 NQI 8H +1.19 BOBBIN SG A INF 8H +1.19 MRPC U-Bend SG A 2 34 NQI 8C +0.38 BOBBIN .i SG A NQI BH +0.62 BOBBIN SG A INF 8C +0.38 MRPC U-Bend SG A INF BH +0.62 MRPC U-Bend SG A INF 2H +0.00 MRPC 4R DSIs SG A 2 35 DSI 2H +0.00 BOBBIN SG A NQI BC +0.31 BOBBIN 2 SG A NOI BH +0.70 BOBBIN I SG A INF BC +0.31 MRPC U-Bend SG A INF 8H +0.70 MRPC U-Bend l SG A INF 2H +0.00 MRPC 4R DSIs t 'r

i BWNS TUBAN II (Version 1.0) 10/22/1993 07:33:16 Beaver Valley Unit 2 -l so A 4R 9/93 t i Page 4 of 18 STEAM GENERATOR A (2RCS-SG21A) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A 2 36 NQI 8C +0.28 BOBBIN SG A NQI BH +0.62 BOBBIN SG A INF 8C +0.28 MRPC U-Bend-SG A INF 8H +0.62 MRPC U-Bend SG A INF 2H +0.00 MRPC 4R DSIs i SG A 2 37 NQI BC +0.39 BOBBIN SG A NQI BH +0.50 BOBBIN SG A INF 8C +0.39 MRPC U-Bend SG A INF BH +0.50 MRPC U-Bend l SG A INF 4H +0.00 MRPC 4R DSIs SG A 2 38 NQI BC +0.33 BOBBIN SG A INF BC +0.33 MRPC U-Bend SG A 2 40 NQI BH +0.61 BOBBIN SG A INF 8H +0.61 MRPC U-Bend SG A INF 5H +0.00 MRPC 4R DSIs SG A 2 41 VOL BC -2.54 MRPC U-Bend t SG A VOL BC -1.73 MRPC U-Bend SG A VOL BH +0.01 MRPC U-Bend SG A INF 2H +0.00 MRPC 4R DSIs SG A 2 44 NQI SC +0.42 BOBBIN SG A NQI BH +1.08 BOBBIN SG A INF BC +0.42 MRPC U-Bend SG A INF 8H +2.08 MRPC U-Bend SG A 2 45 NQI BC +0.35 BOBBIN-SG A INF 8C +0.35 MRPC U-Bend SG A 2 46 NQI BH +1.10 BOBBIN SG A INF 8H +1.10 MRPC U-Bend SG A 2 49 NQI BC +0.39 BOBBIN SG A INF BC +0.39 MRPC U-Bend SG A 2 50 DNG 7C +28.64 BOBBIN SG A 2 51 NQI BC +0.37 BOBBIN-SG A INF SC +0.37 MRPC U-Bend SG A 2 52 ADR 2C +34.72 to +* BOBBIN SG A VOL 2C +34.71 to +* MRPC Special In SG A 2 55 NQI 8C +0.62 BOBBIN SG A INF BC +0.62 MRPC U-Bend i' SG A 2 64 NQI BC +0.40 BOBBIN SG A INF BC +0.40 MRPC U-Bend SG A 2 68 NQI BC +0.49 BOBBIN SG A INF 8C +0.49 MRPC U-Bend SG A 2 73 NQI BC +0.87 BOBBIN SG A INF 8C 40.57 MRPC U-Bend SG A 2 74 NQI BC +0.52 BOBBIN SG A INF BC +0.52 MRPC U-Bend SG A 2 78 NQI BC +0.44 BOBBIN SG A INF 8C +0.44 MRPC U-Bend SG A 2 85 NQI 8C +0.49 BOBBIN SG A NQI BH +0.57 BOBBIN SG A DTI TSC -0.12 BOBBIN SG A INF BC +0.59 MRPC U-Bend SG A INF BH +0.57 MRPC U-Bend SG A INF TSC -0.12 MRPC Special In SG A 2 86 NQI BC +0.44 BOBBIN SG A INF BC +0.44 MRPC U-Bend SG A 2 87 ADR SC +26.62 BOBBIN SG A 2 88 NQI 8H +0.51 BOBBIN SG A INF BH +0.51 MRPC U-Bend SG A 2 90 NQI 8H +0.55 BOBBIN SG A INF BH +0.55 MRPC U-Bend SG A 2 92 DNG IC +20.53 BOBBIN SG A DNG IC +21.26 BOBBIN SG A DNG IC +7.24 BOBBIN SG A DNG IH +12.22 BOBBIN SG A DNG 6C +25.41 BOBBIN SG A NQI BC +0.49 BOBBIN

l BWNS TUBAN II (Version 1.0) 10/22/1993 07:33:16 i i Beaver Valley Unit 2 sc A 4R 9/93 1 ? i Page 5 of 18 STEAM GENERATOR A (2RCS-SG21A) .l 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE 6 SG A INF BC +0.49 MRPC U-Bend f SG A 2 93 DNG IH +8.70 BOBBIN I SG A DNG IH +7.90 BOBBIN i SG A DNG 7H +44.22 BOBBIN j SG A DNG 7H +48.04 BOBBIN SG A DNG 7H +48.68 BOBBIN SG A DNT SH -0.27 BOBBIN SG A DNT 8H +0.46 BOBBIN SG A DNG BH -1.65 MRPC U-Bend SG A DNT 8H +0.47 MRPC U-Bend SG A DNT BH -0.19 MRPC U-Bend SG A INF 7H +48.04 MRPC U-Bend SG A DNG BH -7.28 MRPC Special In i SG A DNG BH -2.C3 MRPC Special In SG A 3 1 ADR 2H +33.69 BOBBIN t SG A INF 2H +33.69 MRPC Special In SG A 3 10 ETL TSH -0.82 BOBBIN SG A ETL TSH +1.16 BOBBIN SG A INF TSH -0.82 MRPC Special In SG A INF TSH +1.64 .MRPC Special In SG A 3 16 ETL TSH +1.64 BOBBIN SG A INF TSH +1.64 MRPC Special In SG A 3 23 ADR 3H +11.01 BOBBIN SG A VOL 3H +10.95 MRPC Special In SG A 3 35 ADR 2H +45.38 BOBBIN SG A ADR 2H +39.17 BOBBIN i SG A VOL 3H -7.05 MRPC Special In i SG A 3 37 ADR 2H +31.88 BOBBIN i SG A DNG 2H +10.84 BOBBIN SG A ETL TSH +0.82 BOBBIN SG A NQI TSH +1.58 MRPC Special In j SG A 3 38 ADR 3H +36.32 BOBBIN SG A ADR 3H +20.97 BOBBIN SG A ADR LH +32.47 BOBBIN f SG A ADR SH +37.69 BOBBIN-SG A ADR SH +20.84 BOBBIN SG A INF 3H +36.32 MRPC Special In i SG A INF 3H +20.97 MRPC Special In SG A INF 5H +21.12 MRPC Special In SG A VOL SH +32.47 MRPC Special In SG A VOL 5H +37.69 MRPC Special In SG A 3 41 ADR TSH +39.71 BOBBIN SG A ADR TSH +39.96 BOBBIN SG A INF TSH +39.71 MRPC Special In SG A INF TSH +39.96 MRPC Special In SG A VOL TSH +37.56 MRPC Special In f SG A 3 43 ADR 6H +32.92 BOBBIN SG A 3 45 ADR 2H +28.58 BOBBIN f SG A VOL 2H +28.58 MRPC-Special In SG A VOL 2H +25.86 MRPC Special In SG A 3 47 DNG 6C +30.08 BOBBIN SG A DNG TSC +8.45 BOBBIN SG A 3 48 ADR 4H +5.36 BOBBIN l SG A DNG (7 +41.47 BOBBIN SG A 3 49 PVN 4H +15.01 BOBBIN l SG A 3 50 DNG 7C +26.91 BOBBIN SG A DNG 7C +27.69 BOBBIN .,} SG A DNG 7H +30.86 BOBBIN-SG A DNG 7H +30.14 BOBBIN i SG A 3 54 DNG 7H +29.70 BOBBIN SG A DNG 7H +29.05 BOBBIN { SG A 3 70 INF 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 3 72 ADR TSC +8.31 BOBBIN r SG A-3 78 INF 4H +0.00 BOBBIN

~ L**************** BWNS TUBAN II (Version l'0) 10/22/1993 07:33:16 Beaver Valley Unit 2 SG A 4R 9/93 i i Page 6 of 18 STEAH GENERATOR A (2RCS-SG2IA) 4R INDICATIONS i GEN ROW COL IND %TW LOCATION TEST TYPE SG A INF 4H +0.00 MRPC 4R DSIs SG A 3 90 ETL TSH +1.23 BOBBIN SG A INF TSH +1.23 MRPC Special In SG A 3 93 DNG 3H +27.05 BOBBIN SG A DNG 7H +45.99 BOBBIN r SG A DNG 7H +46.97 BOBBIN SG A DNG 7H +46.46 BOBBIN SG A DNG 7H +49.12 BOBBIN ? SG A DNT BH -0.56 BOBBIN SG A 4 1 DNG 3H +13.51 BOBBIN SG A 4 15 DSI 4H +0.03 BOBBIN SG A INF 4H +0.03 MRPC 4R DSIs SG A 4 24 DNG 2C +8.16 BOBBIN SG A 4 31 ADR SC +25.29. BOBBIN l i SG A 4 33 INF 2H +0.00 MRPC 4R DSIs SG A 4 34 DRI TEC +9.16 BOBBIN SG A INF TEC +9.16 MRPC Special In SG A 4 44 DRI TEC +9.44 BOBBIN SG A INF TEC +9.44 MRPC Special In SG A 4 48 DSI 6H +0.07 BOBBIN SG A INF 6H +0.07 MRPC.4R DSIs SG A 4 49 ADR TSC +32.02 BOBBIN SG A VOL TSC +32.02 MRPC Special In SG A 4 50 INF 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 4 52 INF 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 4 57 DNG 7C +27.00 BOBBIN SG A DNG 7C +27.73 BOBBIN SG A DNG 7H +29.24 BOBBIN SG A DNG 7H +28.47: BOBBIN i SG A 4 71 DNG IH +6.52 BOBBIN SG A DNG IH +5.83 BOBBIN I SG A DNG 5H +46.85 B0BBIN SG A 4 72 DNG 7C +4.29 BOBBIN SG A DNG TSH +8.43 BOEBIN SG A DNG TSH +7.72 BOBBIN SG A 4 78 INF 5H +0.00 BOBBIN SG A INF 5H +0.00 MRPC 4R DSIs SG A 5 8 DSI 2H +0.03 BOBBIN SG A INF 2H +0.03 MRPC 4R DSIs SG A 5 19 ADR 3H +B.27 BOBBIN SG A 5 23 ETL TSH +0.83 BOBBIN SG A INF TSH +0.83 MRPC Special In -l SG A 5 30 DSI 2H +0.07 BOBBIN SG A INF 2H +0.07 MRPC 4R DSIs SG A 5 42 ADR 4H +34.76 BOBBIN i SG A 5 47 DNG 6H +40.80 BOBBIN i SG A 5 48 DNG 7H +7.92 BOBBIN SG A DSI 6H +0.08 BOBBIN } SG A INF 6H +0.08 MRPC 4R DSIs SG A 5 70 ETL TSH +0.76 BOBBIN SG A INF TSH +0.76 MRPC Special In SG A 6 10 ETL TSH +1.22 BOBBIN SG A INF TSH +1.22 MRPC Special In i SG A 6 32 DSI 2H -0.04 BOBBIN SG A INF 2H -0.04 MRPC 4R DSIs SG A 6 34 INF 2H +0.00 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs SG A 6 41 ADR SH +35.15 BOBBIN SG A VOL 5H +34.48 MRPC Special In [ SG A 6 43 DSI 2H +0.00 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs i SG A 6 48 DNG 6H +47.24 BOBBIN t SG A 6 69 INF 3H +0.00 MRPC 4R DSIs _l i

i l BWNS TUBAN II (Version 1.0) 10/22/1993 07:33:16 Beaver Valley Unit 2 so A

                                • ~

4R 9/93 Page 7 of 18 STEAM GENERATOR A (2RCS-SG21A) i 4R INDICATIONS t GEN RGW COL IND %TW LOCATION TEST TYPE l SG A 6 70 INF 2H +0.00 BOBBIN l SG A INF 2H +0.00 MRPC 4R DSIs SG A PVN 2H +2.29 MRPC 4R DSIs SG A 6 91 DSI SH +0.09 BOBBIN SG A INF 5H +0.09 MRPC 4R DSIs SG A 6 92 ADR SC +28.60 BOBBIN SG A VOL SC +29.46 MRPC Special In SG A 7 1 ADR 2H +16.45 BOBBIN SG A INF 2H +16.45 MRPC Special In l SG A 7 3 INF 3H 40.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs i SG A 7 21 INF-4H +0.00 MRPC 4R DSIs s SG A 7 32 DNG 4H +18.65 BOBBIN SG A 7 43 DNG 2C +48.14 BOBBIN SG A 7 50 DSI 3H +0.07 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 7 54 ADR 3H +32.00 BOBBIN j SG A DSI 3H +0.12 BOBBIN SG A INF 3H 40.12 MRPC 4R DSIs SG A NQI JH +29.00 to +* MRPC Special In SG A 7 64 ADR 8C -0.99 BOBBIN SG A INF 8C -0.99 MRPC Special In SG A 7 71 DNG 6C +32.49 BOBBIN SG A 7 78 DSI 2H +0.05 BOBBIN' SG A DSI 3H -0.07 BOBBIN t SG A INF 2H +0.05 MRPC 4R DSIs SG A INF 3H -0.07 MRPC 4R DSIs-SG A 7 81 DSI 4H +0.00 BOBBIN SG A INF 4H +0.00 MRPC 4R DSIs SG A 7 83 DSI 4H +0.17 BOBBIN SG A INF 4H +0.17 MRPC 4R DSIs ? SG A 7 89 ETL TSH +0.91 BOBBIN SG A NQI TSH +0.55 MRPC Special In 7 SG A 8 3 ADR 7C +28.97 BOBBIN SG A INF 7C +28.97 MRPC Special In .i SG A 8 11 DSI 2H +0.00 BOBBIN i SG A INF 2H +0.00 MRPC 4R DSIs SG A 8 19 DSI 2H -0.07 BOBBIN { SG A INF 2H -0.07 MRPC 4R DSIs i SG A 8 28 DNG 2H +20.59 BOBBIN SG A 8 29 ADR SH +24.54 BOBBIN SG A DSI 2H -0.04 BOBBIN SG A INF 2H -0.04 MRPC 4R DSIs i SG A 8 34 DSI 2H +0.00 BOBBIN .SG A INF 2H +0.00 MRPC 4R DSIs .i SG A 8 36 DSI 5H +0.00 BOBBIN l SG A INF SH +0.00 MRPC 4R DSIs i SG A 8 42 DSI 3H -0.09 BOBBIN SG A INF 3H -0.09 MRPC 4R DSIs SG A B 48 DSI 2H 40.00 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs l SG A 8 50 INF 2H +0.00 MRPC 4R DSIs SG A 8 51 PVN 4H +1.57 BOBBIN f SG A 8 52 INF 3H +0.00 BOBBIN SG A INF 4H +0.00 BOBBIN-a SG A INF 3H +0.00 MRPC 4R DSIs SG A INF-4H +0.00 MRPC 4R DSIs SG A 8 54 INF 3H +0.00 MRPC 4R DSIs i SG A 8' 57 ADR 6C +41.07 BOBBIN l SG A ADR 6C +26.74 BOBBIN SG A ADR 7C +5.31 BOBBIN i SG A ADR' 7C +16.69 BOBBIN -l SG A ADR 7C +9.47 BOBBIN l SG A ADR 7C +20.88 BOBBIN j SG A 8 58 DSI 2H +0.11 BOBBIN j

BWNS TUBAN II-(Version 1.0) 10/22/1993 07:33:16 Beaver Valley Unit 2 SG A 4R 9/93 Page 8 of 18 STEAM GENERATOR A (2RCS-SG21A) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A INF 2H +0.11 MRPC 4R DSIs SG A B 59 DSI 2H +0.00 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs SG A 8 75 ADR 3H +44.10 BOBBIN SG A ADR SC +45.54 BOBBIN SG A ADR BH +10.37 BOBBIN I SG A INF 8H +10.37 MRPC Special In SG A 8 76 ADR 3C +47.26 BOBBIN SG A 8 88 DNG 7C +8.20 BOBBIN-l SG A DNG 7C +7.49 BOBBIN SG A 9 16 DSI 4H -0.11 BOBBIN SG A INF 4H -0.11 MRPC 4R DSIs SG A 9 18 DNG 7H +34.68 BOBBIN SG A 9 22 DSI 3H -0.04 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs a SG A 9 24 DSI 2H -0.07 BOBBIN SG A INF 2H -0.07 MRPC 4R DSIs SG A 9 26 INF 2H +0.00 MRPC 4R DSIs f SG A 9 27 ETL TSC -0.88 BOBBIN SG A INF TSC -0.88 MRPC Special In SG A 9 28 ETL TSC -0.91 BOBBIN SG A INF TSC -0.91 MRPC Special In SG A 9 31 DSI 2H -0.07 BOBBIN SG A ETL TSC -0.95 BOBBIN SG A INF 2H -0.07 MRPC 4R DSIs i SG A INF TSC -0.95 MRPC Special In SG A 9 40 DSI 3H -0.07 BOBBIN SG A INF 3H -0.07 MRPC 4R DSIs SG A 9 48 DSI 2H +0.03 BOBBIN SG A PVN 2H +0.23 MRPC 4R DSIs SG A PVN 2H +1.18 MRPC 4R DSIs i SG A 9 57 DSI 3H -0.03 BOBBIN SG A INF 3H -0.03 MRPC 4R DSIs SG A 9 58 DNG 3C +39.98-BOBBIN. SG A 9 74 DSI 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 9 80 ADR 4C +10.01 BOBBIN SG A 9 86 ADR 7H +23.29 BOBBIN SG A 9 92 ADR BH +12.58 BOBBIN SG A INF BH +12.58 MRPC Special In' SG A 10 8 DSI 2H -0.02 BOBBIN SG A INF 2H -0.02 MRPC 4R DSIs SG A 10 25 DSI 2H -0.04 BOBBIN SG A INF 2H -0.04 MRPC 4R DSIs SG A 10 26 DNG 4H +44.98 BOBBIN SG A 10 38 DSI 63 +0.07 BOBBIN SG A INF 6H +0.07 MRPC 4R DSIs SG A 10 39 ETL TSH -0.91 BOBBIN SG A INF TSH -0.91 MRPC Special In .SG A VOL TSH +1.45 MRPC Special In i SG A VOL TSH +5.32 MRPC Special In SG A VOL TSH +0.16 MRPC Special In i SG A 10 4? ADR TSC +11.61 BOBBIN SG A VOL TSC +12.51 MRPC Special In SG A 10 52 INF 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 10 63 INF 3H +0.05 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 10 79 DSI 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC-4R DSIs I SG A 10 85 ADR SC +17.22 BOBBIN SG A 11 6 DSI 4H +0.00 BOBBIN SG A INF 4H +0.00 MRPC 4R DSIs SG A 11 15 ADR 2H +26.55 BOBBIN SG A 11 30 ADR IH +6.33 BOBBIN

5 BWNS TUBAN II (VersionL1.0) -10/22/1993 07:33:16 - Beaver valley Unit 2 Sc A t . 4R 9/93 l STEAH GENERATOR A (2RCS-SG21A) f 4R INDICATIONS t' GEN ROW COL IND %TW LOCATION TEST TYPE SG A INF 1H +6.33 MRPC Special In 7 SG A 11 49 ADR TSC +20.97 BOBBIN SG A 11 51 ADR 3C +1.91 BOBBIN SG A Il 54 DRI TSC -0.13 BOBBIN SG A INF TSC -0.13 MRPC Special In l SG A 11 55 ADR 7H +35.73 BOBBIN SG A 11 56 ADR 4H +6.92 BOBBIN SG A 11 60 ADR AV4 +7.47 BOBBIN SG A INF AV4 +7.47 MRPC Special In SG A 11 61 ADR AV4 +6.49 BOBBIN i SG A INF AV4 +6.49 'MRPC Special In-SG A 11 63 INF 4H +0.00 BOBBIN-t SG A INF 4H +0.00 MRPC 4R DSIs i SG A 11 66 DSI 3H +0.03 BOBBIN i I SG A INF 3H +0.03 MRPC 4R DSIs SG A 11 75 DSI 3H +0.03 BOBBIN- + SG A INF 3H +0.03 MRPC 4R DSIs j SG A 11 77 DSI 3H +0.08 BOBBIN i SG A INF 3H +0.08 MRPC 4R DSIs SG A 11 79 INF 3H +0.03 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 11 84 ADR 4C +17.40 BOBdIN SG A 11 86 ADR 3H +41.85 BOBBIN SG A 11 91 ADR 7H +42.50 BOBBIN i SG A 12 4 DNG 4C +28.68 BOBBIN SG A DSI 3H -0.05 BOBBIN I SG A INF 3H -0.05 MRPC 4R DSIs. SG A 12 15 ADR SC +3.15 BOBBIN + SG A VOL SC +3.65 MRPC Special.In SG A 12 17 UNG 3H +36.21 BOBBIN SG A DNG TSH +15.32 BOBBIN SG A 12 22 NQI TSC +3.10 BOBBIN SG A VOL TSC +2.94 MRPC Special'In SG A 12 44 DSI 3H -0.11 BOBBIN SG A INF-3H -0.11 MRPC 4R DSIs SG A 12 46 ADR TSC +24.91. BOBBIN a SG A 12 54 ADR SC +14.32 BOBBIN SG A _VOL SC +14.78 ERPC Special In SG A 12 55 INF 4H +0.00 nOBBIN SG A INF 4H +0.00 MRPC 4R DSIs SG A 32 64 DSI 2H +0.00 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs i SG A 12 72 DSI 2H +0.08 BOBBIN i SG A INF 2H +0.08 MRPC 4R DSIs I SG A 13 4 DNG 6C +38.72 BOBBIN SG A 13 7 DNG 6H +40.48 BOBBIN l SG A DNG-6H +41.23 BOBBIN-i SG A 13 15 ADR 3H +24.10 BOBBIN j SG A VOL 3H. +25.48 MRPC Special In .l SG A-13 18 DSI 2H -0.08 BOBBIN SG A INF 2H -0.08 MRPC 4R DSIs ,} SG A 13 22 ADR-6H +39.41 BOBBIN SG A DNG lH +24.41 BOBBIN' SG A DNG 5H. +22.50 BOBBIN l SG'A VOL 7H -12.04 MRPC Special In SG A.13 . 26 DNG 2C '+28.93 BOBBIN SG A 13 33 ADR 7C +9.48 BOBBIN LSG A 13 41 DNG TSC +15.70 BOBBIN SG A 13 42 INF 3H +0.00 -BOBBIN SG A INF ~3H +0.00 MRPC 4R DSIs SG A 13 44 DNG 2H +37.41 BOBBIN i SG A 13 45.ADR SC +27.34 BOBBIN- =i SG A VOL SC +28.46 MRPC Special In SG A 13 48 DNG 2H +33.07 BOBBIN i SG A DNG 2H +32.59 BOBBIN 1 I i m% ---- r w e

b BWNS TUBAN II (Version 1.0) 10/22/1993 07:33:16 Beaver Valley Unit 2 ) so A .i 4R 9/93

                • +*******

i Page 10 of 18 f' STEAM GENERATOR A (2RCS-SG21A) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE l [ SG A DNG 7H +28.41 BOBBIN [ SG 7 DNG 7H +27.69 BOBBIN SG A 13 49 INF 4H +0.00 MRPC 4R DSIs i SG A 13 53 INF 4H +0.00 MRPC 4R DSIs 4 SG A 13 55 INF 4H +0.09 BOBBIN SG A INF 4H +0.00 MRPC 4R DSIs SG A 13 63 INF 3H +0.03 BOBBIN-SG A INF 3H +0.CL MRPC 4R DSIs SG A PVN 3H +1.12 MRPC 4R DSIs ? SG A 14 6 INF 3H +0.00 MRPC 4R DSIs SG A 14 21 DNG 1H +27.23 BOBBIN SG A 14 24 DNG 3H +6.78. BOBBIN SG A 14 27 DSI 5H +0.05 BOBBIN I SG A INF 5H +0.05 MRPC 4R DSIs SG A 14 47 DNG 2H +21.21 BOBBIN SG A DNG 6H +42.78 BOBBIN SG A 14 48 DNG 2C +27.51 BOBBIN t SG A DNG 7C +2B.34 BOBBIN SG A DSI 2H +0.08 BOBBIN. t SG A PVN 2H -0.11 MRPC 4R DSIs F SG A 14 62 DSI 3H +0.05 BOBBIN I SG A INF 3H +0.00 MRPC 4R DSIs SG A 14 68 DSI 2H +0.05 BOBBIN I SG A INF 2H +0.00 MRPC 4R DSIs SG A 14 70 ADR SC +23.89 BOBBIN i SG A VOL SC +24.19 MRPC Special In { SG A 14 81 DNG AV2 -0.47 BOBBIN SG A DNG AV2 -0.10 BOBBIN SG A SAI AV2 -0.85 MRPC Special In .i SG A 14 82 DNG AV2 +1.57 BOBBIN I SG A SAI AV2 +3.13 MRPC Special In f SG A 14 84 DNG AV2 +1.76 BOBBIN SG A SAI AV2 +1.76 MRPC Special In SG A 14 85 DNG AV1 +10.77 BOBBIN SG A SAI. AV1 +11.09 MRPC Special In SG A 14 89 DNG 3C +27.95 BOBBIN l SG A 15 10 ADR 7C +31.22 BOBBIN SG A 15 17 DSI 2H -0.03 BOBBIN f SG A INF 2H -0.03 MRPC 4R DSIs. i SG-A 15 25 INF 2H +0.00 MRPC 4R DSIs SG A 15 30 INF 2H +0.00 MRPC 4R DSIs 7 SG A 15 47 DNG 2C +24.01 BOBBIN l SG A DNG 6C, +35.87 BOBBIN SG A 15 48 DNG 6H +39. 73 BOBBIN j SG A 15 51 DNG 7H +30.19 BOBBIN SG A 15 55 INF 3H +0.00 BOBBIN i SG A INF 3H +0.00 MRPC 4R DSIs i SG A 15 83 DNG AV2 +4.73 BOBBIN l SG A SAI AV2 .+4.82 MRPC.Special In 9 +5.22 MRPC Special In j SG A SAI AV2 . +5.30 BOBBIN I SG A 15 84 DNG AV2 SG A DNG AV2 +3.07 BOBBIN SG A DNG AV2 +4.72 BOBBIN SG A SAI. AV2 +3.39 MRPC Special In j SG A SAI AV2 +5.13 MRPC Special.In l SG A SAI AV2 +5.70 MRPC Special In SG A 15 92 DNG 3C +21.42 . BOBBIN I SG A DNG AV1 -0.86 BOBBIN SG A DNG TSC- +15.74 BOBBIN SG A DNG TSC +8.55 BOBBIN 'l SG A DNG TSC +15.09 BOBBIN i SG A DNG TSC +9.23 BOBBIN SG A SAI AV1 -0.66 MRPC Special In SG A 16 11 DNG 5H +1.90 BOBBIN SG A DNG 6C +32.75 BOBBIN

BWNS TUBAN II (Version 1.0) 10/22/1993 07:33:16 Beaver Valley Unit 2 so A 4R 9/93 Page 11 of 18 STEAM GENERATOR A~(2RCS-SG22A) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE 16 24 DNG SH +44.50 BOBBIN l SG A ~ 16 25 DNG 3H +7.08 BOBBIN SG A SG A 16 26 INF 2H +0.00 MRPC 4R DSIs i SG A 16 32 DNG IC +2.75 BOBBIN SG A DNG IC +3.52 BOBBIN t SG A NQI IH +24.30 BOBBIN .{ SG A DNG TSC +16.97 BOBBIN SG A DNG TSC +17.71 BOBBIN I SG A INF IH +24.30 MRPC Special In ( SG A VOL 1H +19.03 MRPC Special In SG A VOL IH +21.09 MRPC Special In -j SG A 16 35 INF 2H +0.00 MRPC-4R DSIs i SG A INF 4H +0.00 MRPC 4R DSIs l SG A 16 40 DSI 3H -0.15 BOBBIN t SG A INF 3H -0.15 MRPC 4R DSIs SG A 16 41 INF 2H +0.00 HRPC 4R DSIs SG A 16 44 DSI 3H -0.13 BOBBIN ~ SG A DSI 4H +0.00 BOBBIN. SG A PVN 3H -0.13 MRPC 4R DSIs SG A PVN 4H +0.00 MRPC 4R DSIs SG A 16 45 DNG 2C +10.58 BOBBIN SG A DNG 2C +9.07 BOBBIN SG A DNG 2C +11.44 BOBBIN SG A DNG 20 +6.74 BOBRIN .) SG A 16 66 INF 33 +0.00 BOBBIN. SG A INF 3H +0.00 MRPC 4R-DSIs I SG A 16 75 INF 5H +0.00 MRPC 4R DSIs SG A 16 78 DSI SH +0.13 BOBBIN t SG A INF SH .+0.13 MRPC 4R DSIs SG A 16 79 DNG AV2 +3.71 BOBBIN SG A SAI AV2 +3.95 _MRPC Special In SG A 16 80 INF 5H +0.03 BOBBIN SG A DNG Av2 +4.30 BOBBIN SG A DNG AV2 +3.98 BO8 BIN SG A INF 5H +0.00 MRPC 4R DSIs i SG A SAI AV2 +4.39 MRPC Special In SG A SAI AV2 +4.68 MRPC Special In SG A 16 81 DNG AV2 +5.01 BOBBIN SG A DNG AV2 +3.62 BOBBIN SG A SAI AV2 +3.55. MRPC Special In i SG A SAI -AV2 +5.43-MRPC Special In { SG A 16 82 DNG AV2 +3.94 BOBBIN SG A SAF AV2 +4.51 MRPC Special.In SG A 16 83 DNG AV2 +5.24 BOBBIN 4 SG A-MAI AV2 +5.76 .MRPC Special In j SG A 17 10 DSI 3H -0.10 BOBBIN-SG A INF .3H -0.10 MRPC 4R DSIs SG A 17 23-'ADR 1H +28.20-BOBBIN SG A DNG 6H 441.52 BOBBIN SG A 17 24 ADR 4C +17.69' BOBBIN I SG A 17 41 ADR 3H +22.08 BOBBIN SG A DNG 6C +37.97 BOBBIN SG A 17 44 DSI 4H -0.02 BOBBIN-SG A. INF 4H -0.02 MRPC 4R DSIs I SC A 37 47 DNG 2H +8.74 BOBBIN SG A 17 48 DNG 2H +25.88 BOBBIN SG A DNG 6H +47.47 BOBBIN SG A 17 55 DNG 6H +43.06 BOBBIN SG A 17 59 DSI 2H +0.13 BOBBIN SG A INF 2H +0.13 MRPC 4R DSIs SG A 17 67 INF 3H +0.00 MRPC 4R DSIs SG A 17 77 DNG AV2 +6.45 BOBBIN SG A SAI -AV2 +7.17 MRPC Special In SG A 17 78 DNG AV2 +6.92 BOBBIN SG A SAI AV2 +7.59 MRPC Special In

i 'l BWNS TUBAN II (Version 4.0) 10/22/1993 07:33:16 i Beaver Valley Unit 2 SG A i 4R 9/93 l l Page 12 of 18 f STEAM GENERATOR A (2RCS-SG21A) t 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A SAI AV2 +7.92 MRPC Special In SG A 17 79 DNG AV2 +7.75 BOBBIN -i SG A DNG AV2 +3.90 BOBBIN ? SG A SAI AV2 +8.49 MRPC Special In SG A SAI AV2 +4.40 MRPC Special In SG A 18 7 INF 4H +0.00 BOBBIN SG A INF 4H +0.00 MRPC 4R DSIs SC A 18 16 DNG SH +30.20 BOBBIN Sf; A 18 19 DNG TSH +5.41 BOBBIN 'i SG A 18 22 ADR 2H +7.14 BOBBIN !G A 18 31 DNG TSC +7.98 -BOBBIN !-G A 18 39 DNG IH +6.89 BOEBIN-3G A 18 48 DNG 2C +32.18 BOBBIN SG A 18 70 INF 3H +0.00 BOBBIN 3G A INF 3H +0.00 MRPC 4R DSIs 53 A 18 82 DSI 2H +0.13 BOBBIN SG \\ INF 2H +0.13 MRPC 4R DSIs ? SG n 18 88 DNG SC +12.30 BOBBIN SG L 19 7 DNG 2H +18.94 BOBBIN SG A 19 15 DSI 3H -0.07 BOBBIN SG A INF 3H -0.07 MRPC 4R DSIs SG A 19 19 DSI 2H -0.05 BOBBIN

[

SG A INF 2H -0.05 ERPC 4R DSIs t SG A 19 26 DSI 2H +0.02 BOBBIN SG A INF 2H +0.02 MRPC 4R DSIs i SG A 19 32 DNG 1H +7.19 BOBBIN SG A DNG IH +6.49 BOBBIN. SG A 19 37 DSI 3H -0.02 ' BOBBIN- 'i SG A INF 3H -0.02 MRPC 4R DSIs SG A 19 40 DNG TSH +1.98 BOBBIN SG A 19 41 DNG 6C +28.93 BOBBIN SG A 19 44 DNG SC +30.79 BOBBIN' ( SG A 19 46 PVN 2C +26.95 BOBBIN SG A DNG TSC +17.64 BOBBIN SG A 19 47 DNG TSC +10.89 BOBBIN .i SG A 19 57 DSI 2H +0.08 BOBBIN SG A INF 2H +0.08 MRPC 4R DSIs l SG A 19 67 INF 4H +0.00 BOBBIN SG A INF 4H +0.00 MRPC 4R DSIs SG A 19 69 INF 4H +0.00 BOBBIN SG A INF 4H . +0.00 MRPC 4R DSIs SG A 19 90 DNG AV1 +20.52 BOBBIN 'SG A SAI AV1 +22.49 MRPC Special In SG A 20 47 DNG 2H +40.36 BOBBIN SG A -20 51 DSI 3H +0.00 BOBBIN E SG A INF 3H +0.00 MRPC 4R DSIs SG A 20-60 DSI 2H +0.13 BOBBIN i SG A INF 2H +0.13 MRPC 4R DSIs SG A 20 77 ADR 7C +21.62 BOBBIN SG A VOL 7C +22.04 MRPC Special In SG A 20 82 ADR 6C +14.75 BOBBIN l SG A 21 10 DNG 6H +12.34 BOBBIN' SG A 21 22 DNG 7H +4.18 BOBBIN SG A 21 34 DSI 2H +0.00 BOBBIN SG A INF 2H +0.00 'MRPC 4R DSIs SG A 21 58 ADR SC . +35.84 BOBBIN I SG A 21 60 INF 2H +0.00 MRPC 4R DSIs f SG A INF 4H +0.00 MRPC 4R DSIs a SG A INF SH +0.00 MRPC 4R DSIs. 't SG A PVN 3H +1.00 MRPC 4R DSIs SG A PVN 3H -0.11 MRPC 4R DSIs i SG A PVN 3H -0.35 MRPC 4R DSIs SG A PVN 3H +0.14 MRPC 4R DSIs: 'i SG A PVN 3H -0.81 MRFC 4R DSIs i SG A PVN 3H -1.12 MRPC 4R DSIs .n I

i - BWNS.TUBAN.II (Version 1.0) ~10/22/1993 07:33:16 Beaver Valley Unit 2 i SG-A 4R 9/93 I

...............+

t Page 13 of 18' STEAM GENERATOR A (2RCS-SG21A) 4R INDICATIONS r GEN ROW COL IND %TW LOCATION TEST TYPE SG A 22 8 DSI 4H -0.05 BOBBIN SG A INF 4H -0.05 MRPC.4R DSIs [ SG A 22 17 DSI 2H -0.05 BOBBIN SG A INF 2H -0.05 MRPC 4R DSIs-SG A 22 21 DNG 4C +10.99 BOBBIN I SG A 'e2 44 ADR 3H +24.03 BOBBIN SG A ADR 4H +22.26 BOBBIN SG A INF 4H +0.00 MRPC 4R DSIs SG A INF 3H +24.03 MRPC Special In-SG A VOL 4H +23.68 KRPC'Special In SG A 22 54 INF 2H +0.00 BOBBIN [ SG A INF 2H +0.00 MRPC 4R DSIs SG A 22 55 INF 2H +0.00 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs-SG A 22 68 DSI 4H +0.00 BOBBIN 'i SG A INF 4H +0.00 MRPC 4R DSIs SG A 22 69 INF 2H +0.00 BOBBIN SG A PVN 2H +2.86 MRPC 4R DSIs 'i SG A 22 70 DSI 6H +0.08 BOBBIN SG A INF 6H +0.00 MRPC 4R DSIs l SG A 23 11 DSI 3H -0.07 BOBBIN SG A INF 3H -0.07 MRPC 4R DSIs SG A 23 17 INF 2H +0.00 MRPC 4R DSIs l SG A 23 27 DSI 5H -0.07 BOBBIN SG A INF 5H -0.07 MRPC 4R DSIs r SG A 23 32 DNG 6H +1.15 . BOBBIN SG A DSI 2H -0.02 BOBBIN SG A INF 2H -0.02 MRPC 4R DSIs SG A 23 42 DSI 2H +0.00 BOBBIN. SG A INF 2H +0.00-MRPC 4R DSIs i SG A 23 70 INF 2H +0.00 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs SG A 24' 24 DSI 2H -0.07 BOBBIN SG A INF 2H -0.07 MRPC 4R DSIs 'I SG A 24 29 DSI 2H +0.00 BOBBIN SG A INF 2H +0.00-MRPC 4R DSIs SG A 24 37 DNG 4C +43.37 BOBBIN SG A 24 54.INF 3H +0.05 BOBBIN' t SG A PVN 3H +0.18 MRPC 4R DSIs SG A 24 59 INF 3H +0.00 MRPC 4R DSIs SG A 25 9 DSI 4H +0.00 BOBBIN SG A INF 5H +0.00 BOBBIN SG A INF 4H +0.00 MRPC 4R DSIs-l SG A INF 5H +0.00. MRPC 4R DSIs SG A 25 12 DSI 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DS. 4 SG A-25 21 ADR 4H +35.48 BOBBIN SG A 25 22 DSI 2H +0.00 DOBBIN SG A-INF 2H +0.00 MRPC 4R DSIs .l SG A 25 23 DNG SH +9.32 BOBBIN SG A 25 32 DNG SH +44.03 BOBBIN SG A 25 43 DNG 7C +28.97 BOBBIN SG A 25 52 INF 2H +0.00 BOBBIN e SG A INF 4H +0.00 KRPC 4R DSIs SG A' 25 87 DNG 6C +11.18' BOBBIN SG A 26 27 ADR IC +16.78 BOBBIN 1 SG A ADR SH +43.35 BOBBIN SG A ODI 17 IH +13.46 BOBBIN SG A VOL 1H +13.49 MRPC Special In SG A 26 35 DNG 3H +31.27 BOBBIN .j SG A-DSI 2H +0.00 BOBBIN. 1 SG A INF 2H +0.00 MRPC 4R DSIs I SG A 26 37 ADR 6H- +17.20 BOBBIN SG A 26 50 INF 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs ~

I 'BWNS TUBAN-II (Version 1.0)- 10/22/1993 07:33:16 Beaver Valley Unit 2 ............w... So x 4R 9/93 j Page 14 of 18 l STEAM GENERATOR A (2RCS-SG21A) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE j SG A 26 52 INF 3H +0.03 BOBBIN i SG A INF 3H +0.00 MRPC 4R DSIs SG A 26 57 ADR 3C +3.05 BOBBIN SG A 26 75 DNG IC +9.57 BOBBIN' SG A 27 33 DNG 7C +31.03 BOBBIN SG A 27 38 DNG 1H +3.09 BOBBIN SG A 27 48 INF 2H +0.08 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs SG A 27 63 INF 2H +0.05 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs SG A 27 65 ADR 7H +6.09 BOBBIN i SG A 27 71 ODI 10 AV2 +0.00 BOBBIN SG A 27 72 ODI 21 AV1 +0.00 BOBBIN SG A 27 79 ETL TEH +18.91 BOBBIN SG A ETL TEH +4.80 BOBBIN SG A INF TEH +18.91 MRPC Special'In. SG A INF TEH +4.80 MRPC Special In SG A 27 80 ADR 6H +34.96 BOBBIN SG A 28 50 DSI 3H 40.00 BOBBIN SG A INF 3H 40.00 MRPC 4R DSIs SG A 28 52 INF 2H +0.13 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs SG A 28 57 INF 2H -0.16 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs SG A 28 61 DSI 5H -0.03 BOBBIN SG A -INF 5H -0.03 MRPC 4R DSIs SG A 28 80 INF 3H +0.08 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 29 85 DNT 4C +0.00 BOBBIN SG A 29 16 DSI 3H -0.05 BOBBIN-SG A INF 3H -0.05 MRPC 4R DSIs I SG A 29 38 DNG IH +2.77 BOBBIN SG A 29 64 DSI 2H +0.00 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs i SG A. 30 19 DS1 2H -0.05 BCBLIN SG A INF-2H -0.05 MRPC 4R DSIs SG A 30 22 DSI 2H -0.05 BOBBIN SG A INF 2H -0.05 MRPC 4R DSIs SG A 30 43 DNG 3H +6.72 BOBBIN i SG A 30 50 DSI 2H +0.03 BOSBIN t SG A INF 2H +0.03 MRPC'4R DSIs SG A 30 51 DSI 4H -0.08 BOBBIN SG A INF 4H -0.08 MRPC 4R DSIs SG A 30 60 INF 3H +0.00 BOBBIN. SG A .INF 3H +0.00-MRPC 4R DSIs ~ e SG A 31 13 DNG 8H +1.07 BOBBIN I t SG A NQI 8H +1.02 MRPC Special In SG A 31 18 DSI 2H -0.05 BOBBIN SG A INF 2H -0.05 MRPC 4R DSIs i SG A 31 44 DNG 4C +28.54 BOBBIN SG A DNG 6C +48.19 BOBBIN SG A 31 52 ODI 15 AVI -1.35 -BOBBIN-SG A INF AV1 -1.35 MRFC Special In SG A 32 23 ODI 10 TSH +4.69 BOBBIN-1 SG A VOL TSH +4.15 MRPC Special In. SG A 32 36 DNG-SH +10.98 BOBBIN j SG A 32 39 DNG TSH +15.58 BOBBIN l SG A 32 45 DNT IC +0.36 BOBBIN SG A 32 51 DSI 2H +0.10 BOBBIN SG A INF 2H +0.10 MRPC 4R DSIs SG A 32 60 DNG SC +38.92 BOBBIN SG A 32 65 ADR AV4 +2.58 BOBBIN SG A VOL AV4 +3.10 MRPC Special In SG A 32 76 DNG 6C +40.91 BOBBIN SG A 33 18 DSI 2H +0.00 BOBBIN

BWNS TUBAN II-(Version-1.0) 10/22/1993 07:33:16 Beaver Valley Unit 2 so A 4R 9/93 I l Page 15 of 18 STEAM GENERATOR A (2RCS-SG21A) l 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A INF 2H +0.00 MRPC 4R DSIs ,j SG A 33 19 DNG 4C +12.29 BOBBIN l SG A 33 26 DSI 3H -0.08 BOBBIN SG A INF 3H -0.08 MRPC 4R DSIs SG A 33 37 DNG 4C +13.24 BOBBIN SG A 33 38 DNG -7H +32.05 BOBBIN SG A 33 45 DNG IC +1.73 BOBBIN j SG A DNG IC +22.76 BOBBIN SG A DNG 4C +4.39 BOBBIN l SG A DNT IC +0.26 BOBBIN j SG A 33 46 DNT 1C -0.18 BOBBIN SG A 33 4 8 DNG 4H +6.60 BOBBIN SG A 33 53 DNG IC +2.66 BOBBIN SG A DNG IC +3.41 BOBBIN + SG A DNG 1C +6.42 BOBBIN i SG A DNG IC +7.20 BOBBIN l SG A DNG 4C +29.98 BOBBIN i SG A 33 54 DNG 4H +43.62 BOBBIN SG A 33 61 DNG AV2 +10.00 BOBBIN i SG A SAI AV2 +10.44 MRPC Special In SG A SAI AV2 +11.23 MRPC Special In SG A 33 65 INF 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs i SG A 33 70 ODI 20 AV1 +0.00 BOBBIN r SG A 34 19 DNG 2H +44.25 BOBBIN l SG A 34 26 DNG 3C +44.14 BOBBIN SG A 34 27 DNG IH +13.75 BOBBIN SG A 34 33 DNG TSH +5.09 BOBBIN i SG A 34 35 DSI 3H -0.03 BOBBIN -j SG A INF 3H -0.03 MRPC 4R DSIs i SG A 34 40 DNG 7H +40.28 BOBBIN i SG A DNG 7H~ +39.53 BOBBIN SG A 34 51 DNG' AV1 +13.03 BOBBIN-, l SG A SAI AV1 +13.11 MRPC Special In SG A 34 52 ADR 7H +9.88 BOBBIN SG A DNG SH +46.82 BOBBIN I SG A 34 53 DSI 2H +0.03 BOBBIN i SG A INF 2H +0. 00 - MRPC 4R DSIs i SG A 34 58 DNG 2C +28.01 BOBBIN e SG A DNG 2H +33.24 BOBBIN Sli A DNG 7C +10.43 BOBBIN SG A 34 70 ODI 17 AV3 +0.00 . BOBBIN l SG A 34 77 ODI 14'2C +39.36 BOBBIN [ SG A INF 2C +39.36 MRPC Special In 't' SG A 35 24 DSI 3H -0.05 BOBBIN SG A PVN 3H -0.22 MRPC 4R DSIs l SG A 35 32 DNG SH +11.53 BOBBIN SG A 35 33 DNG SH +11.10 BOBBIN: i I SG A 35 LB INF 2H +0.00 BOBBIN. SG A INF 2H r+0.00 MRPC 4R DSIs SG A 35 60 DNG TSH +16.29 BOBBIN SG A 35 70 ODI 15 AV3 +0.00 BOBBIN SG A

35. -72 DSI 3H

+0.03 BOBBIN SG A ODI 12 AV3 +0.00 BOBBIN SG A ODI. 14 AVI +0.00 BOBBIN '{ SG A INF 3H +0.03 MRPC 4R DSIs SG A 36 23 DSI 3H -0.08 BOBBIN i SG A INF 3H -0.08 MRPC 4R DSIs SG A 36 24 DNG 4H +12.78 BOBBIN SG A 36 28 ADR IH +2.77 to +* BOBBIN SG A INF 1H +2.27 to +* MRPC Special'In SG A 36 35 DSI 6H +0.03 . BOBBIN-SG A INF 6H +0.03 MRPC 4R DSIs SG A 36 39 DNG SC +26.20 BOBBIN i' SG A 36 41 DNG 7C +43.89 BOBBIN I

L i ~ ) BWNS TUBAN II-(Version 1.0) 10/22/1993 07:33:16 l Beaver valley Unit 2 sg A 4R 9/93 i I Page 16 of 18 j STEAH GENERATOR A (2RCS-SG21A) 4R INDICATIOdS GEN ROW COL IND %TW LOCATION TEST TYPE j -f SG A 25 44 DSI 3H -0.11 BOBBIN SG A INF 3H -0.11 MRPC 4R DSIs i SG A 36 45 DNG 2H +17.53 BOBBIN SG A 36 49 INF 5H +0.00 BOBBIN j SG A INF 5H +0.00 MRPC 4R DSIs SG A PVN SH +2.41 MRPC 4R DSIs i SG A 36 56 INF 2H +0.00 BOBBIN j SG A INF 2H +0.00 MRPC 4R DSIs j SG A 36 60 INF 3H +0.00' BOBBIN t SG A INF 3H +0.00 'MRPC 4R DSIs SG A 37 22 ADR 7C +38.68 BOBBIN SG A 37 26 DSI 3H -0.03 BOBBIN SG A INF 3H -0.03 MRPC 4R DSIs SG A 37 32 ADR 3C +5.95 BOBBIN = SG A VOL 3C +6.22 MRPC Special In SG A 37 54 INF SH +0.00 BOBBIN SG A INF SH +0.00 MRPC 4R DSIs' i SG A 37 63 ADR 7C +14.40 BOBBIN SG A VOL 7C +14.39 MRPC Special In SG A 37 64 INF 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs ~! SG A 38 34 DNG TSH +7.88 BOBBIN SG A DNG TSH +7.14 BOBBIN ~* SG A 38 51 ADR 7H +12.52 BOBBIN SG A 38 54 INF 5H +0.00 BOBBIN i SG A INF 5H +0.00-MRPC 4R DSIs } SG A 38 66 INF 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs .j SG A 39 27 DNG 7H +45.59 BOBBIN SG A 39 35 DNG IH +11.00 BOBBIN SG A DNG IH +2.13 BOBBIN SG A DNG 1H +1.45 BOBBIN l SG A DNG 1H +11.74 BOBBIN ~* SG A DNT 1H -0.74 BOBBIN SG A DNG TSH +18.53 BOBBIN SG A DNG TSH +17.73 BOBBIN I SG A DNG TSH +17.05 BOBBIN I SG A 39 37 DNG 2C +27.53 BOBBIN: I SG A 39 40 ADR 4C +40.64 BOBBIN SG A VOL 4C +40.67 MRPC Special In SG A 39 53 INF 4H +0.00 BOBBIN SG A INF 4H +0.00 MRPC 4R DSIs SG A 39 54 INF 3H +0.00 BOBBIN i SG A INF 3H +0.00' MRPC 4R DSIs l SG A 39 55 INF 2H -+0.00 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs i SG A 39 66 INF 3H +0.00 BOBBIN li SG A INF 3H +0.00 MRPC 4R DSIs i SG A 39 69 ADR SH +48.69 BOBBIN SG A DNG 3C +34.43 BOBBIN SG A VOL SH +48.34 MRPC Special.In SG A 40 27 DSI 4H -0.02 ' BOBBIN-1 SG A ODI 22 7H +40.04 BOBBIN i SG A INF .4H -0.02 MRPC 4R DSIs i SG A VOL' 7H +40.41 MRPC Special In SG A 40 35 DNG 1H +8.65 -BOBBIN SG A DNG 2C ^28.82' BOBBIN-i SG A DNG 2C +28.11 BOBBIN SG A DNG 2H +27 83 ' BOBBIN j SG A 40 37 DSI' 3H -0.05 BOBBIN-_ SG A INF 3H- -0.05 MRPC 4R DSIs l SG A 40 41 ADR 7C +27.93 BOBBIN- -i SG A 40-68 ODI 16 AVI +0.00 BOBBIN .i SG A ODI 20 AV2 -+0.00-BOBBIN SG A ODI 21 AV4 +0.00-BOBBIN-l 4

'BWNS TUBAN II (Version 1.0)~ 10/22/1993 07:33:16 Beaver Valley Unit 2 ..*********=**** so A 4R 9/93 Page'17 of 18 STEAM GENERATOR A (2RCS-SG21A) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG A 41 28 DSI 3H -0.05 BOBBIN SG A INF 3H -0.05 MRPC 4R DSIs SG A 41 34 DNG 3H +27.40 BOBBIN SG A -41 36 DNG 1H +25.20 BOBBIN SG A DNG IH +25.95 BOBBIN SG A DNG IH +26.57 BOBBIN SG A DNG 6H +44.51 BOBBIN SG A DNG 8H +28.50 BOBBIN SG A DNG BH +39.67 BOBBIN SG A INF BH +28.50 MRPC.Special In SG A-INF 8H +39.67 MRPC Special In. SG A 41 40 CDI 5 6H +3.16 BOBBIN SG A NQI 6H +3.38 MRPC Special In SG A VOL 6H +5.18 MRPC Special In SG A 41 41 DSI 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 41 42 DNG TSH +8.07 BOBBIN SG A 41 59 INF 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 41 62 INF 4H +0.00 MRPC 4R DSIs SG A 42 33 DSI SH -0.07 BOBBIN SG A INF 5H -0.07 MRPC 4R DSIs SG A 42 37 DNG 7H +36.22 BOBBIN SG A 42 39 ADR 3C +5.16 BOBBIN SG A 42 44 ADR 2H +44.02 BOBBIN SG A INF 2H +44.02 MRPC Special.In .SG A 42 47 DSI 3H -0.07 BOBBIN SG A INF 3H -0.07 MRPC 4R DSIs SG A 42 60 INF 4H +0.00 BOBBIN SG A ADR AV3 +1.28 BOBBIN SG A INF 4H +0.00 MRPC 4R DSIs SG A VOL AV3 +1.59 MRPC Special In SG A 42 63 INF 3H +0.00 BOBBIN SG A INF 3H +0.00 MRPC 4R DSIs SG A 43 31 DNG 7H +45.49 . BOBBIN SG A DNG 7H +46.23 BOBBIN 4 SG A 43 32 DNG 7C +47.41 BOBBIN SG A DNG 70 +46.56 BOBBIN SG A 43 35 DNG 7C +26.65 BOBBIN l SG A 43 36 ADR 2C +5.92 BOBBIN i SG A DNG 3H +26.18 BOBBIN i SG A DNG TSH +5.91 BOB 3IN SG A INF 2C +5.92. MRPC Special.In i SG A 43 38 ADR 3C +6.35 BOBBIN SG A VOL 3C +7.20. MRPC Special In i SG A 43 40 ADR 6H +46.70 BOBBIN SG A DSI 3H -0.07 BOBBIN i SG A INF 3H -0.07 MRPC 4R DSIs 1 SG A 43 42 DNG 7H +33.16 BOBBIN SG A DNG 7H +33.86 BOBBIN SG A DNG.. 7H +44.92 BOBBIN 1 SG A 43 60 DNG AV3 +11.24 BOBBIN - j SG A ODI 11-AV3 +0.00 BOBBIN - j SG A SAI AV3 +11.12 MRPC Special In SG A 43 64 ODI 10 AV4 +0.00 BOBBIN i SG A 44 35 ADR 7C +34.44 BOBBIN - i SG A 44 36 ODI 9 6C +32.08 BOBBIN SG A VOL 6C +31.67 MRPC Special In SG A 44 39 ADR AV4 +1.79 BOBBIN SG A VOL AV4 +2.00 MRPC Special In SG A 44 43 DNG 8H +22.26 BOBBIN SG A NQI BH +22.26 MRPC Special In-SG A 44 45 DSI 4H -0.05 BOBBIN SG A INF 4H -0.05 MRPC 4R DSIs SG A 44 46 ADR 7C +34.59 BOBBIN o i

l BWNS TUBAN II (Version 1.0) 10/22/1993 07:33:16 t Beaver Valley Unit 2 so A 4R 9/93 -i 7 i Page 13 of 18 j STEAM GENERATOR A (2RCS-SG21A) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST' TYPE SG A 44 48 ADR SH +31.57 BOBBIN SG A INF 2H +0.59 BOBBIN SG A INF 2H +0.00 MRPC 4R DSIs l SG A 44 <49 ADR 4H +31.95 BOBBIN SG A ODI 11 AV3 +0.00 BOBBIN SG A VOL 4H +31.54 MRPC Special In SG A 44 52 ADR SH +16.65 BOBBIN SG A 44 55 ODI 18 AV4 +0.00 BOBBIN } SG A 44 56 ADR 2H +14.60 BOBBIN SG A ODI 12 AV4 +0.00 BOBBIN-l SG A 44 57 ODI 10 AV1 +0.00 BOBBIN SG A ODI 10 AV2 +0.00. BOBBIN l SG A 44 60 ADR 7C +46.28 BOBBIN SG A 44 61 ADR AV4 +15.47 BOBBIN SG A DNG AV3 +12.78 BOBBIN SG A DNG AV3 +12.05 BOBBIN SG A INF AV4 +15.47 MRPC Special In p SG A-SAI AV3 +12.77 MRPC Special In l SG A SAI AV3 +12.09 MRPC Special In 3 SG A 44 62 ODI 10 AV2 +0.00 BOBBIN SG A 45 36 DNG IH +8.04 BOBBIN SG A DHG IH +3.93 BOBBIN SG A DNG IH +2.59 BOBBIN ) SG A DNG IH +3.59 BOBBIN SG A DNG TSH +7.50 BOBBIN j SG A DNT BH +0.25 BOBBIN SG A DNG TSH +9.29 BOBBIN l SG A 45 37 DNT 8C +0.00 BOBBIN' SG A DNT BH +0.00 BOBBIN l SG A 45 38 DNT 8H +0.34-BOBBIN t 2 SG A-DNT 8H -0.39-BOBBIN SG A 45 49 ODI 11.AV3 +0.00 BOBBIN SG A 45 58 DNG BH +30.51 BOBBIN SG A MAI BH +33.18 MRPC Special In SG A 46 41 DNG AV3 -0.97 . BOBBIN SG A SAI AV3- -0.96 MRPC Special In Total Indications Found = 1141 Total Tuben Found = 527 .j l r i 1 l ) l 1 i ,,w. -w a

BWNS~1UBAN II (Versien 1.0) 10/22/1993 09:13:47 Beaver Valley Unit 2 So A ,ee...ua******** 4R 9/93 Page 1 of 2 STEAM GENERATOR A (2RCS-SG21A) 4R PLUGGED TUBES i GEN ROW COL IND %TW LOCATION TEST TYPE i SG A 1 84 ADR 6H +17.25 BOBBIN f SG A VOL 8H +13.13. MRPC U-Bend i SG A 1 93 DNT BH +0.25 BOBBIN SG A NQI 8H +0.50 MRPC U-Bend SG A NQI BH +0.56 MRPC Special In SG A 2 21 NQI BC +0.56 BOBBIN SG A NQI 8H +0.53 BOBBIN 'i SG A ETL TSH +1.68 BOBBIN SG A SAI TSH +1.51 MRPC Special In SG A 3 37 ADR 2H +31.88 BOBBIN SG A DNG 2H +10.84 BOBBIN SG A ETL TSH +0.82 BOBBIN SG A NQI TSH +1.58 MRPC Special In SG A 7 54 ADR 3H +32.00 BOBBIN SG A DSI 3H +0.12 BOBBIN SG A NQI 3H +29.00 to +* MRPC Special In SG A 7 89 ETL TSH +0.91 BOBBIN SG A NQI TSH +0.55 MRPC Special In SG A 10 39 ETL TSH -0.91 BOBBIN SG A VOL TSH +1.45 MRPC.Special In SG A VOL TSH +5.32 MRPC Special In SG A VOL TSH +0.16 MRPC Special In SG A 14 81 DNG AV2 -0.47 BOBBIN SG A DNG AV2 -0.10 BOBBIN j SG A SAI AV2 -0.85 MRPC Special In SG A 14 82 DNG AV2 +1.57 BOBBIN SG A SAI AV2 +3.13 MRPC Special In SG A 14 84 DNG AV2 +1.76 BOBBIN ? SG A SAI AV2 +1.76 MRPC Special In SG A 14 85 DNG AV1 +10.77 BOBBIN SG A SAI AV1 +11.09 MRPC Special In SG A 15 83 DNG AV2 +4.73 BOBBIN i SG A' SAI AV2 +4.82 MRPC Special In SG A SAI AV2 +5.22 MRPC Special In i SG A 15 84 DNG AV2 +5.30 BOBBIN SG A DNG AV2 +3.07 BOBBIN-SG A DNG AV2 +4.72 BOBBIN l SG A SAI AV2 +3.39 MRPC Special In SG A SAI AV2 +5.13 MRPC Special In SG A SAI AV2 +5.70 MRPC Special In i SG A 15 92 DNG 3C +21.42. BOBBIN SG A DNG AV1 -0.86 BOBBIN-SG A DNG TSC +15.74 BOBBIN l SG A DNG TSC +8.55 BOBBIN 1 SG A DNG TSC +15.09 . BOBBIN' SG A DNG TSC- -+9.23 BOBBIN SG A SAI AVI -0.66 MRPC Special In SG A 16 45 DNG 2C +10.58 BOBBIN SG A DNG 2C +9.07 BOBBIN 'SG A DNG 2C +11.44 BOBBIN SG A .. DNG 2C +6.74 BOBBIN I SG A 16 79 DNG AV2 +3.71 BOBBIN SG A SAI AV2' .+3.95 MRPC Special In -{ SG A 16 80 DNG AV2 +4.30 BOBBIN SG A DNG AV2 +3.98' BOBBIN j SG A SAI' AV2 +4.39 MRPC Special In r SG A SAI AV2 +4.68 ~MRPC Special In SG A 16 81 DNG AV2 +5.01 BOBBIN SG A DNG AV2 +3.62 BOBBIN SG A SAI AV2 +3.55 MRPC Special.In SG A SAI AV2 +5.43 MRPC Special In SG A 16 82 DNG AV2 +3.94 BOBBIN-SG A SAI AV2 +4.51 MRPC Special In SG A 16 83 DNG AV2 +5.24 BOBBIN SG A MAI AV2 +5.76 MRPC Special In

) 1 BWNS TUBAN II (Version 1.0) 10/22/1993 09:13:47 1' Beaver Valley Unit 2 so a 4R 9/93 P Page 2 of 2 STEAM GENERATOR A (2RCS-SG21A) 4R PLUGGED TUBES '[ GEN ROW COL IND %TW LOCATION TEST TYPE 6 SG A 17 77 DNG AV2 +6.45 BOBBIN SG A SAI AV2 +7.17 MRPC Special In l SG A 17 78 DNG AV2 +6.92 BOBBIN SG A SAI AV2 +7.59 MRPC Special In SG A SAI. AV2 +7.92 MRPC'Special In j i A 17 79 DNG AV2 +7.75 BOBBIN SG A DNG AV2 +3.90 BOBBIN l SG A SAI AV2 +8.49 MRPC Special In SG A SAI AV2 +4.40 MRPC Special.In SG A 19 90 DNG AV1 +20.52 BOBBIN SG A SAI AV1 +22.49 MRPC Special In i SG A 31 13.DNG BH +1.07 BOBBIN SG A NQI 8H +1.02 .MRPC Special In [ SG A-33 61 DNG AV2 +10.00 BOBBIN SG A SAI AV2 +10.44 MRPC Special In SG A SAI AV2 +11.23 .MRPC Special In SG A 34 51 DNG AV1 +13.03 BOBBIN SG A SAI AV1 +13.11 MRPC Special In SG A 41 40 ODI 5 6H +3.16 BOBBIN SG A NQI 6H +3.38 MRPC Special In SG A VOL 6H +5.18 MRPC Special In SG A 43 60 DNG AV3 +11.24 BOBBIN-SG A ODI 11 AV3 +0.00 BOBBIN SG A SAI AV3 +11.12 MRPC Special In SG A 44 39 ADR AV4 +1.79 BOBBIN i SG A VOL AV4 +2.00 MRPC Special In SG A 44 43 DNG 8H +22.26 BOBBIN SG A NQI BH +22.26 MRPC Special In SG A 44 61 ADR AV4 +15.47 ' BOBBIN SG A DNG AV3 +12.78 BOBBIN SG A DNG AV3 +12.05 BOBBIN SG A SAI AV3 +12.77-MRPC Special In SG A SAI AV3 +12.09 MRPC Special In SG A 45 58 DNG 8H +30.51 -BOBBIN SG A MAI BH +33.18 MRPC Special In SG A 46 41 DNG AV3 -0.97 BOBBIN SG A SAI AV3 -0.96 MRPC.Special In [ Total Indications Found = 102 Total Tubes Found = 34 Total Tubes in Input File = 34 I ? ? Y c l l i f I u

ATTACHMEN T 5 i ESIT #2 LTH REFCELING OLTAGE STEAM GENERATOR "B" (2RCS-SG21B) 't 4

I 10/22/1993 08:12'51 (Version 1.0) ley Unit 2 BWNS TUBAN II Beaver Val

    • ene***********

SG B t 4R 9/93 I i STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS i GEN ROW COL IND %TW LOCATION TEST TYPE SG B 1 1 NQI BC -1.16 . BOBBIN i SG B INF 8C -1.96 MRPC U-Bend SG B 1 2 NQI BC +0.42 BOBBIN j SG B INF BC +0.49 MRPC U-Bend SG B 1 3 NQI 7H +47.54 BOBBIN SG B INF 7H +47.54 MRPC U-Bend SG B INF 8C +0.71 MRPC U-Bend .i SG B 1 4 NQI 8C -1.59 BOBBIN i SG B INF BC -2.02 MRPC U-Bend i SG B 1 5 NQI 8C -1.55 BOBBIN i SG B INF 8C -1.55 MRPC U-Bend SG B PVN BC -0.19 MRPC U-Bend SG B 1 6 NQI 7H +47.93 BOBBIN SG B NQI 8C -1.05 BOBBIN SG B INF 7H +47.93 MRPC U-Bend + SG B INF BC -1.44-MRPC U-Bend SG B 1 10 NQI BC -1.34 BOBBIN-j SG B INF 8C -1.34 MRPC U-Bend SG B 1 11 NQI BC -1.18 BOBBIN SG B INF 8C -1.91 MRPC U-Bend SG B 1 12 NQI 7C +49.42 BOBBIN i SG B INF 7C +49.05 MRPC U-Bend SG B 1 15 NQI BC ~1.86 BOBBIN t SG B INF 8C -1.86 MRPC U-Bend. j SG B 1 16 NQI 8C -1.59 BOBBIN SG B INF BC -1.59 MRPC-U-Bend SG B 1 17 DNT TSC +14.44 BOBBIN { SG B 1 19 DNG IC +6.25 BOBBIN ~ SG B DNG IC +5.49 BOBBIN SG B NQI BC -1.94. BOBBIN SG B INF 8C -1.94 MRPC U-Bend SG B 1 20 NQI BC -2.29 BOBBIN SG B INF 8C -2.29 MRPC U-Bend SG B 1 21 NQI 7C +47.05 BOBBIN 1 SG B INF 7C +47.05 MRPC U-Bend' 'j SG B 1 24 NQI 7C +47.36 BOBBIN SG B INF 7C +47.36 MRPC'U-Bend j SG B 1 36 DSI 2H -0.05 BOBBIN i SG B INF 2H -0.05 -MRPC 4R DSIs SG B 1 54 VOL 8H -0.92 MRPC U-Bend ~ -j SG B 1 56 DNG 3H +6.31 BOBBIN SG B 1 57 DSI 4H +0.05 BOBBIN SG B INF 4H +0.05 MRPC 4R DSIs-SG B 1 59 SAI BH +3.54 MRPC U-Bend SG B 1 70 DNG 2H +19.35 BOBBIN-SG B 1 73 NQI 7C +48.11 BOBBIN SG B INF 7C +48.11 MRPC U-Bend SG B 1 74.NQI 7C +48.68 . BOBBIN. SG B INF 7C +48.68-MRPC U-Bend 3 SG B 1-75 ODI 23 7C +47.89 BOBBIN SG B INF 7C +47.89 MRPC Special In SG B 1 76 NQI 7C +48.64-BOBBIN. i SG B . INF 7C +48.64 MRPC U-Bend SG B 1 78 NQI 7C. +49.01 BOBBIN SG B INF 7C +49.01 MRPC U-Bend 't SG B 1 79 NQI 7C- +48.61 BOBBIN l - SG B INF 7C +48.61 MRPC U-Bend SG B 1 88 NQI-7C +47.60 BOBBIN-SG B INF 7C +47.60 MRPC U-Bend SG B 1 90 NQI 7C +45.73 BOBBIN SG B INF 7C +45.73 MRPC U-Bend 1 SG B 1 91 NQI 7C +46.58 BOBBIN l SG B INF 7C +46.58 MRPC U-Bend SG B 1 92 NQI 7C +46.32 BOBBIN SG B -INF 7C +46.32 MRPC U-Bend j

r ~ BWNS TUBAN II (Version 1.0) 10/22/1993 08:12:51 ..e.=*** .e***** Beaver Valley Unit 2 SG B l 4R 9/93 l t Page 2 of 16 STEAM-GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 1 93 NQI 7C +46.08 BOBBIN [ SG B INF 7C +46.08 MRPC U-Bend SG B 1 94 NQI 7C +46.18 BOBBIN ~ 46.18 MRPC U-Bend SG B INF 7C + SG B 2 1 NQI 8H +1.12 BOBBIN SG B INF BH +1.12 MRPC U-Bend SG B 2 2 NQI BH +1.21 BOBBIN SG B INF BH +1.21 MRPC U-Bend i SG B 2 7 NQI BH +0.72 BOBBIN-SG B INF BH +0.72 MRPC U-Bend l SG B 2 12 DNG 3C +45.17 BOBBIN SG B DNG 6C +28.60 BOBBIN I SG B DNG 6C +27.88 BOBBI" SG B 2 14 NQI 8H +0.40 BOBBIN SG B INF BH +0.40 MRPC U-Bend t SG B 2 16 NQI-8H +0.45 BOBBIN SG B INF 8H +0.45 MRPC U-Bend l SG B 2 17 DSI 4H +0.00 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs SG B 2 24 DNG 2C +25.13 BOBBIN SG B 2 44 DSI 2H -0.03 BOBBIN SG B INF 2H -0.03 MRPC 4R DSIs i SG B 2 48 NQI BH +0.21 BOBBIN SG B INF BH +0.21 MRPC U-Bend SG B 2 49 NQI BH +0.55 BOBBIN SG B INF BH +0.55 HRPC U-Bend SG B 2 50 INF 4H +0.00 MRPC 4R DSIs l SG B 2' 54 DSI 4H -0.05 BOBBIN SG B NQI BH +0.29 BOBBIN SG B INF 8H +0.29 MRPC U-Bend SG B INF 4H +0.00 MRPC 4R DSIs SG B 2 61 DNG 6H +16.59 BOBBIN [ SG B 2 63 DSI 4H -0.03 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs -j SG B 2 65 PVN TSH +0.28 MRPC TSH SG B 2 81 NQI BC +0.52 BOBBIN SG B INF BC +0.52 MRPC U-Bend t SG B 2 85 NQI BH +0.53 BOBBIN SG B INF 8H +0.53 MRPC U-Bend SG B 2 86 NQI 8C +0.46 BOBBIN + SG B NQI BH +0.33 BOBBIN SG B INF 8C +0.46 MRPC.U-Bend t SG B INF BH +0.33 MRPC U-Bend .) SG B 2 88 NQI 8H +0.56 BOBBIN SG B INF-8H +0.56 MRPC U-Bend j SG.B 2 89 NQI 8H +0.78 BOBBIN j SG B INF 8H +0.78-MRPC U-Bend SG B 2 90 NQI 8H '+1.35 BOBBIN SG B INF. BH +1.35 MRPC U-Bend r SG B 2 91 NQI BH +1.17 BOBBIN SG B INF 8H +1.17' MRPC U-Bend SG B 2-92 INF 4H +0.00 BOBBIN t SG B NQI BH +1.53 BOBBIN-- SG B INF 8H +1.53 MRPC U-bend I SG B INF-2H +0.00 MRPC 4R DSIs SG B INF 4H +0.00 MRPC 4R DSIs I SG B 2 94 NQI '8H +0.92' . BOBBIN l SG B INF BH- +0.92 MRPC U-Bend i SG B 3 22 ADR SC +40.15 BOBBIN SG B VOL SC +40.14 MRPC Special In SG B 3 25 DSI 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs f SG B 3 32 DSI 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs l SG B 3 52 PVN TSH -0.70 MRPC TSH

BWNS TUBAN II (Version 1.0) 10/22/1993 08:12:51 Beaver Valley Unit 2 SG B 4R 9/93 Page 3 of 16 STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 3 54 DSI 2H 40.06 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 3 60 DSI 2H +0.03 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 3 66 DRI TEC +11.08 BOBBIN SG B INF TEC +11.08 MRPC Special In SG B 3 70 DNG 3H +26.68 BOBBIN SG B DNG 4C +25.55 BOBBIN SG B 3 71 DNG 1H +17.52 BOBBIN SG B 3 72 DSI 3H +0.12 BOBBIN SG B INF 3H +0.12 MRPC 4R DSIs SG B 3 76 DNG 4C '+14.19 BOBBIN SG B 3 92 DNG 4C +48.14 BOBBIN SG B 4 13 ADR 6C +38.08 BOBBIN SG B. VOL 6C +38.08 MRPC Special In SG B 4 23 INF 2H +0.00 MRPC 4R DSIs SG B 4 32 DSI 3H -0.03 BOBBIN SG B PVN 3H +0.51 MRPC 4R DSIs SG B 4 47 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 4 54 DSI 2H -0.08 BOBBIN SG B INF 2H -0.08 MRPC 4R DSIs SG B 4 55 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 4 57 DSI 2H +0.03 BOBBIN SG B INF 2H +0.03 HRPC 4R DSIs SG B-4 58 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 4-61 DNG 6C +39.95 BOBBIN SG B 4 67 ODI 11 SC +23.02 BOBBIN SG B VOL SC +23.02 MRPC Special In-SG B 4 88 DNG 1H +28.67 BOBBIN SG B DNG TSC +6.91' BOBBIN SG B 4 94 DNG 2C +18.13 BOBBIN SG B DNG 7H +26.83 BOBBIN SG B 5 13 INF 2H +0.00 MRPC 4R DSIs SG B 5 46 DSI 2H +0.00 BOBBIN. SG B INF 2H +0.00-MRPC 4R DSIs SG B 5 50 ADR 3C +8.69 BOBBIN SG B INF 3C +8.69 MRPC Special In SG B 5 53 DSI 2H -0.03 BOBBIN SG B INF 2H -0.03 MRPC 4R DSIs SG B 5 59 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 5 61 DSI 2H -0.03 BOBBIN SG B INF 2H -0.03 MRPC 4R DSIs SG B 5 74 ADR 6C +8.75 BOBBIN SG B VOL 6C +8.75 MRPC Special In SG B 5 75 DSI 4H +0.03 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs SG B 5 76 INF 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R.DSIs SG B 5 84 DNG~ SC +47.31 BOBBIN SG B 5. 88 ETL TSC -0.71 BOBBIN SG B 6 16 DNG 7C +24.20 BOBBIN SG B DSI 3H +0.06 BOBBIN SG B INF 3H +0.06 MRPC 4R DSIs SG B 6 24 DNG IC +26.01 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 6 59 DNG 2C +35.44 BOBBIN SG B 6 61 DNG 7C +14.77 BOBBIN SG B 'ETL TSC -0.93 BOBBIN SG B 7 1 DNG 3H +34.71 BOBBIN SG B DNG 7H +11.30 BOBBIN SG B 7-6 DSI 4H +0.00 BOBBIN

e**.....~********

BWNS TUBAN II-(Version-1.0) 10/22/1993 08:12:51

                                • ?

Beaver Valley Unit 2 l

            • =*********

SG B 4R 9/93 Page 4 of 16 STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B INF 4H +0.00 MRPC-4R DSIs SG B 7 7 DNG 7H +7.73 BOBBIN SG B 7 10 DNG 4H +29.78 BOBBIN SG B DSI 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 7 13 DNG 2C +6.78 BOBBIN SG B 7 29 DSI 2H -0.02 BOBBIN-SG B INF 2H +0.00 MRPC 4R DSIs SG B 7 30 DSI 4H -0.15 BOBBIN f SG B INF 4H +0.00 MRPC 4R DSIs SG B 7 47 DNT 2C +3.73 BOBBIN SG B 7 55 DSI 4H -0.08 BOBBIN SG B INF 4H -0.08 MRPC 4R DSIs SG B 7 57 DSI 2H -0.08 BOBBIN SG B INF 2H -0.08 MRPC 4R DSIs SG B 7 68 DNG 2C +19 /7 BOBBIN SG B DNG 7H +1" 5 BOBBIN SC B 7 84 DSI 4H

  • v.08 BOBBIN SG B INF 4H

+0.08 -MRPC 4R DSIs SG B 7 87 ADR IC +12.38 BOBBIN l SG B VOL IC +12.14. MRPC Special-In SG B 8 12 DSI 4H +0.00 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs SG B 8 19 DSI 3H -0.11 BOBBIN -( SG B INF 3H -0.11 MRPC 4R DSIs SG B B 24 DSI 4H +0.00 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs SG B 8 29 DNG 4H +37.33 BOBBIN SG B DNG 4H +39.28 BOBBIN SG B DNG 4H +38.69 BOBBIN SG B 8 31 DSI 2H -0.02 BOBBIN-SG B INF 2H +0.00 MRPC 4R DSIs SG B 8 32 INF 2H -0.05 BOBBIN SG B INF 2H +0.00 MRPC.4R DSIs SG B 8 33 DSI 3H -0.07 BOBBIN SG B INF 3H +0.00-MRPC 4R DSIs SG B 8 43 DNG 5H +23.86 BOBBIN SG B 8 47 DNG 2H -1.26 BOBBIN SG B DNG 4H .+27.12 BOBBIN SG B 8 55 DSI 2H -0.08 BOBBIN.. [' SG B INF 2H -0.08 MRPC 4R DSIs. SG B 8 61 DNG TSC +38.02 BOBBIN SG B 8 63 DSI 3H +0.03 BOBBIN SG B DSI 4H. -0.10 BOBBIN. SG B INF 3H +0.03 MRPC 4R DSIs i SG B INF 4H -0.10 MRPC 4R DSIs SG B 8 70 DNG 6H +39.26 BOBBIN SG B 8 72 DSI 4H -0.05 BOBBIN SG B INF 4H -0.05 MRPC 4R DSIs SG'B B 77 DNG' 3C +23.89 BOBBIN SG B DNG 4C +31.37 BOBBIN SG B 8 85 DNG TSC +12.99 BOBBIN SG B 8 87 DNG 4C +40.40 BOBBIN SG B 9 12 DSI 3H -0.05 BOBBIN I SG B INF 3H -0.05 MRPC 4R DSIs s SG B 9 15 INF 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 9 23 DSI 2H +0.02 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs-SG B 9 24 DSI 3H -0.03 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 9 25 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 9 26 DSI 3H +0.00 BOBBIN' SG B INF 3H +0.00 MRPC 4R DSIs

1 J BWNS'TUBAN II (Version 1.0) 10/22/1993 08:12:51 Beaver Valley Unit 2 SG B t ^**************** 4R 9/93 t i Page 5 of 16 STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 9 38 PVN TSH +5.09 MRPC TSH SG B PVN TSH -0.28 MRPC TSH SG B 9 39 DNG TSC +29.16 BOBBIN i SG B 9 40 DSI 3H +0.00 BOBBIN l SG B INF 3H +0.00 MRPC 4R DSIs SG B 9 46 DSI 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 9 47 DNG 6H +40.80 BOBBIN i SG B 9 52 DSI 2H +0.00 BOBBIN SG B DSI 5H -0.08 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B INF SH -0.08 MRPC 4R DSIs SG B 9 59 DSI 3H -0.05 BOBBIN. 1 SG B INF 3H -0.05 MRPC.4R DSIs SG B 9 64 DSI 2H +0.00 BOBBIN I SG B INF 2H +0.00 MRPC 4R DSIs SG B 9 76 DSI 3H +0.06 BOBBIN SG B INF 3H +0.06 MRPC 4R DSIs i SG B 9 82 DSI 4H +0.08 BOBBIN SG B EPI TSH +7.42 BOBBIN SG B INF 4H +0.08 MRPC 4R DSIs SG B 9 92 DSI 2H +0.06 BOBBIN SG B INF 2H +0.06 MRPC 4R DSIs SG B 10 2 DNG 4C +39.31 BOBBIN SG B 10 12 DNG 4H +42.47 BOBBIN SG B 10 32 DSI 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs i SG B 10 54 DSI 2H -0.13 BOBBIN SG B INF 2H -0.13 XRPC 4R DSIs SG B 10 58 DSI SH -0.05 BOBBIN j SG B INF SH -0.05 MRPC 4R DSIs SG B 10 59 DNG TSC +14.35 BOBBIN f* SG B 10 60 DNG TSC +10.72 BOBBIN SG B DNG TSC +9.96 BOBBIN I SG B 10 62 NQI 4C +24.77 BOBBIN SG B INF 4C +24.77 KRPC Special In + SG B 10 63 DSI 2H -0.05 BOBBIN SG B INF 2H -0.05 MRPC 4R DSIs SG B 10 64 DSI 2H +0.00 BOBBIN. SG B INF 2H +0.00 MRPC 4R DSIs -i SG B 10 72 DSI 4H +0.03 BOBBIN SG B INF 4H +0.03 MRPC 4R DSIs. SG B 10 90 DSI 2H +0.06 BOBBIN SG B INF 2H +0.06 MRPC 4R DSIs SG B 10 92 NQI 2H +37.53 BOBBIN SG B VOL 2H +37.53 MRPC Special In SG B 11 5 DSI 4H -0.03 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs SG B 11 6 INF 4H +0.00 BOBBIN SG B DNG AV1 +8.18 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs i SG B INF AVI +8.18 MRPC Special In-t SG B 11 18 DNG 6C +5.36 BOBBIN SG B 11 20 INF 3H +0.00 MRPC 4R DSIs SG B 11 22 DSI 3H -0.03 BOBBIN SG B DSI 4H -0.03 BOBBIN SG B INF 3H -0.03 MRPC 4R DSIs SG B INF 4H -0.03 MRPC 4R DSIs SG B 11 47 INF 3H +0.00 MRPC 4R DSIs SG B 11 48 DSI 3H +0.09 BOBBIN- 'l SG B ODI 14 SC' +39.05 BOBBIN + SG B IN F-3H +0.09 MRPC 4R DSIs SG B VOL SC +39.05 MRPC Special In SG B 11 50 DNG 3C +9.91 BOBBIN i SG B DNG 6H +1.17 BOBBIN-l

'BWNS TUBAN II (Version 1.0) 10/22/1993 08:12:51 Beaver Valley Unit 2 1 SG B { 4R 9/93 ee************** t Page 6 of 16 STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG-B 11 56 DSI 2H -0.05 BOBBIN SG B INF 2H -0.05 MRPC 4R DSIs l SG B 11 59 DSI 3H -0.08 BOBBIN-SG B DSI 4H -0.03 BOBBIN SG B INF 3H -0.08 MRPC 4R DSIs SG B INF 4H -0.03 MRPC 4R DSIs SG B 11 60 DSI 3H -0.08 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 11 64 DNG 3C +31.21 BOBBIN SG B 11 69 DNG 6C +28.33 BOBBIN SG B 11 73 DNG 7H +28.53 BOBBIN SG B 11 75 DSI SH -0.08 BOBBIN i SG B INF SH -0.08 MRPC 4R DSIs i SG B 11 89 ODI 4 3H +12.71 BOBBIN SG B VOL 3H +12.28 MRPC Special In SG B VOL 3H +10.34 MRPC Special In SG B 12 13 DNG IH +4.23 BOBBIN SG B 12 19 DNG 7C +13.05 BOBBIN SG B 12 31 DSI 3H -0.06 BOBBIN SG B ODI 53 7C +33.01 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B PVN 7C +33.01 MRPC Special In SG B 12 35 DNG 7C +2.61 BOBBIN SG B 12 61 DSI 3H -0.03 BOBBIN SG B INF 3H -0.03 MRPC 4R DSIs SG B 12 78 ADR 2C +24.01 BOBBIN SG B VOL 2C +24.01 MRPC Special In SG B 13 32 DNG 4H +4.41 BOBBIN i SG B 13 35 DSI 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 13 37 DSI 3H -0.03 BOBBIN SG B INF 3H -0.03 MRPC 4R DSIs i SG B 13 66 DSI 2H +0.08 BOBBIN SG B INF 2H +0.08 MRPC 4R DSIs SG B 13 68 INF 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 13 79 ADR 6H +6.09 BOBBIN SG B VOL 6H +5.51 MRPC Special In SG B 13 87.DSI-2H +0.14 BOBBIN ,i SG B INF 2H +0.14 MRPC 4R DSIs SG B 13 90 DSI 2H +0.06 BOBBIN SG B INF 2H +0.06-MRPC 4R DSIs' SG B 14 7 DSI 3H +0.00 BOBBIN i SG B INF 3H +0.00 MRPC 4R DSIs. SG B INF 3H +0.00 MRPC 4R DSIs SG B 14 11 PVN 1H +6.55 BOBBIN SG B PVN 1H- +11.90 BOBBIN i SG B PVN 2H '+47.58 BOBBIN SG B PVN 2H +47.74 ' BOBBIN SG B-14 16 INF 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 14 21 DNG TSC +4.91 BOBBIN SG B DNG' TSC +4.22 BOBBIN i SG B 14 32 DSI 2H +0.03 BOBBIN SG B INF 2H +0.03 MRPC 4R DSIs i SG B 14 36 DNG 7C +37.38 BOBBIN SG B DNG 7C +36.61 BOBBIN-SG B DNG 7H +31.62 BOBBIN' i SG B DNG 7H +30.91 BOBBIN 4 SG B 14 47 DNG 2H +28.48 BOBBIN I SG B 14 55 DSI 4H +0.03 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs I SG B 14' 75'DSI 4H +0.00 BOBBIN ~! SG B INF 4H +0.00 MRPC 4R DSIs SG B 14 83 ADR IC +17.06 BOBBIN I -~~

-f***************- BWNS TUBAN II (Version 1.0)'. 10/22/1993 08:12:51 1**************** Beaver Valley Unit.2 SG B 4R 9/93 Page 7 of 16 STEAH GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B ADR 7H +18.67 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B VOL IC +16.66 MRPC Special In SG B VOL 7H +16.27 MRPC Special In SG B 14 87 DSI 4H +0.03 BOBBIN SG B INF 4H +0.03 MRPC 4R DSIs SG B 14 90 DSI 2H +0.17 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 15 11 DSI 3H +0.00 BOBBIN r SG B INF 3H +0.00 MRPC 4R DSIs SG B 15 20 DSI 2H -0.06 BOBBIN. INF 2H +0.00 MRPC 4R DSIs SG B . 48 DNG 7H +31.76 BOBBIN SG B 15 SG B DNG 7H +31.13 BOBBIN SG B 15 64 DSI 2H +0.06 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 15 71 DSI 2H +0.06 BOBBIN SG B DSI 4H +0.03 BOBBIN SG B INF 2H +0.06 MRPC 4R DSIs SG B INF 4H +0.03 MRPC 4R DSIs SG B 15 72 DNG 7C +8.35 BOBBIN SG B DNG 7C +7.34 BOBBIN SG B 15 74 DNG 7C +8.41 BOBBIN SG B 15 77 ADR 1C +18.93 BOBBIN SG B VOL 1C +18.56 MRPC Special In l SG B 15 79 ETL TSH -0.89 BOBBIN SG B 15 83 INF 3H +0.00 MRPC 4R DSIs SG B 15 87 DSI 2H +0.06 BOBBIN SG B INF 2H + 0. 0 6.- MRPC 4R DSIs SG B 16 9 INF 2H +0.00 MRPC 4R DSIs SG B 16 35 DNG 7C +16.15 BOBBIN SG B 16 47 DNG 6H +40.24 BOBBIN l SG B 16 54 DSI 29 -0.06' BOBBIN SG B INF 2H -0.06 MRPC 4R DSIs SG B 16 58 DSI 3H +0.18 BOBBIN. SG B INF 3H +0.18 MRPC 4R DSIs SG B 16 67 DNG 2H +39.04 BOBBIN SG B 16 70 INF 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 16 75 ADR AV4 +11.87. BOBBIN ~ SG B INF AV4 +11.87 'MRPC Special In SG B 16 77 ADR 6C +28.01 BOBBIN SG B VOL 6C +28.54 MRPC Special In i SG B 17 16 INF 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 17 45 DNG 7H +7.32 BOBBIN SG B 17 48 INF 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG.B 17 55 DSI 2H +0.00 BOBBIN 1 SG B INF 2H +0.00 MRPC 4R DSIs SG B 17 56 DSI 3H +0.03 BOBBIN -SG B INF 3H +0.03 MRPC 4R DSIs 'i SG B 17 57 DSI 2H +0.03 BOBBIN SG B DSI 3H +0.06 BOBBIN SG B INF 2H +0.03 MRPC 4R DSIs SG B INF 3H +0.06 MRPC 4R DSIs l SG B 17 64 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC'4R DSIs SG B 17 80 INF 4H +0.00 MRPC 4R DSIs SG B 17 86 INF 3H +0.00 BOBBIN. SG B INF 3H +0.00 MRPC 4R DSIs SG B 17 90 DSI 2H +0.14 BOBBIN SG B INF 2H +0.14 MRPC 4R DSIs SG B 18 11 INF 4H +0.00 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs i i [ yw y , ~ n

BWNS TUBAN II (Version 1.0)' 10/22/1993.08:12:51 Beaver Valley Unit 2 ~********- ^***** SG B 4R 9/93 Page 8 of 16 ' STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 18 18 DSI 2H +0.06 BOBBIN SG B INF 2H +0.06 MRPC 4R DSIs SG B 18 33 ETL TSC -0.93 BOBBIN SG B INF TEC +20.39 MRPC Special In SG B 18 41 DSI 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 18 71 ODI 14 2H +8.52 . BOBBIN SG B VOL 2H +7.32 MRPC Special In SG B 19 18 DNG 6H +22.81 BOBBIN SG B 19 21 DNG SH +36.38 BOBBIN SG B DNG 7H +6.61 BOBBIN SG B DSI 3H -0.03 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 19 22 DNG 7H +7.48 BOBBIN SG B 19 27 DSI 2H -0.03 BOBBIN-SG B INF 2H +0.00 MRPC 4R DSIs SG B 19 29 DNG 7C +17.15 BOBBIN SG B 19 40 DSI 3H -0.14 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 19 46 DSI 2H -0.03 BOBBIN SG B VOL 2H +0.18 MRPC 4R DSIs SG B 19 47 DNG 2C +9.71 BOBBIN SG B 19 50 INF 3H +0.08 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 19 54 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 19 67 DSI 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 19 74 DSI 2H +0.03 BOBBIN SG B DSI 3H +0.00 BODBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B INF 3H +0.00 MRPC 4R DSIs SG B 19 76 INF 2H +0.00 MRPC 4R DSIs SG B 19 85 DSI 2H +0.06 BOBBIN SG B INF 2H +0.06-MRPC 4R DSIs SG B 19 86 ADR 3C +36.88 BOBBIN SG B VOL 3C +36.88 MRPC Special.In SG B 20 13 ADR IH +19.16 BOBBIN SG B . VOL IH +19.16 MRPC Special In SG B 20 15 DNG 4C +25.52 BOBBIN SG B 20 16 DSI 3H +0.00 BOBBIN. SG B INF 3H +0.00 MRPC 4R DSIs SG B 20 18 DSI 2H +0.09 BOBBIN SG B DSI 4H +0.06 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B INF 4H +0.00 MRPC 4R DSIs SG B 20 19 ADR 4C +6.18 BOBBIN' SG B INF 4C +6.18 MRPC Special In SG B 20 23 DSI 3H -0.11 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 20 27 DNG IC +12.10 BOBBIN SG B 20 28 ADR 3H +20.45 BOBBIN. SG B ADR 4H +18.96 BOBBIN SG B INF 4H +18.96 MRPC Special In SG.B VOL 3H +19.96 MRPC Special In SG B 20 36 DNG SC +34.34 BOBBIN SG B 20 37 ADR 2H +48.36 BOBBIN SG-B VOL 2H +48.36 MRPC Special'In SG B 20 60 INF 4H +0.00 MRPC 4R DSIs SG B 20 62 DSI .2H -0.05 BOBBIN SG B INF 2H- -0.05 MRPC 4R DSIs SG B 20 71 DNG AV4 +6.35 BOBBIN SG B DNG AV4 +6.69 MRPC Special In SG B 20 72 DNG AV4 +6.59 BOBBIN SG B DNG AV4 +7.02 MRPC Special In r I 8

BWNS TUBAN II (Version 1.0) 10/22/1993 08:12:51 Beaver Valley Unit 2 SG B 4R 9/93 L t i Page 9 of 16 STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS I GEN ROW COL IND %TW LOCATION TEST TYPE SG B 20 73 DNG AV4 +6.51 BOBBIN SG B DNG AV4 +6.83 MRPC Special In SG B 20 79 INF 4H +0.00 MRPC 4R DSIs SG B 20 88 DSI 2H +0.09 BOBBIN SG B INF 2H +0.09 MRPC 4R DSIs SG B 21 16 DNG 7H +7.00 BOBBIN SG B 21 23 ADR 4H +10.18 BOBBIN L SG B VOL 4H +9.97 MRPC Special In SG B 21 25 DNG 3H +42.02 BOBBIN i SG B 21 45 DSI 4H -0.03 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs SG B 21 47 DSI 3H -0.06 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 21 59 DSI 4H +0.00 BOBBIN ? SG B INF 4H +0.00 MRPC 4R DSIs SG B 21 82 ODI 49 TSC +0.69 BOBBIN [ SG B VOL TSC +0.66 .MRPC Special In SG B 21 83.ODI '28 TSC +0.63 BOBBIN SG B PLP TSC +0.45 MRPC Special In SG B 21 84' EPI TSH +7.14 BOBBIN SG B 22 28 DSI 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 22 44 DSI 3H -0.06 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 22 52 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs l SG B 22 53 DSI 2H +0.00 BOBBIN SG B DSI 3H +0.06 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs-SG B INF 3H +0.06 MRPC 4R DSIs i SG B 22 55 INF 3H +0.08 BOBBIN -l SG B INF 3H +0.00 MRPC 4R DSIs-SG B 22 56 INF 2H +0.08 BOBBIN-SG B INF 2H +0.00 MRPC 4R DSIs SG B 22 58 DSI 2H +0.08 BOBBIN SG B INF 3H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs i SG B INF 3H +0.00 MRPC 4R DSIs a SG B 22 62 ADR 3C +39.52 BOBBIN t SG B VOL 3C +39.52 MRPC Special'In ( SG B 22 67 DSI 3H +0.06 BOBBIN SG B INF 3H +0.06 MRPC 4R DSIs i SG B 22 68 ADR 3C +23.04-BOBBIN l SG B VOL 3C +23.29 MRPC Special In -l SG B 22 69 ADR 3C +29.95 BOBBIN i SG B ADR 3C +35.76-BOBBIN l SG B VOL 3C +29.95 MRPC Special In SG B VOL 3C +35.76 MRPC Special In SG B 22 87 ADR AV3 +5.38 BOBBIN .i SG B INF AV3 +5.38 MRPC Special In SG B 23 7 DNG IH +7.65 BOBBIN SG B 23 28 DNG 7C +10.27 BOBBIN SG B DNG 7C . +33.52 BOBBIN SG B DSI 3H +0.06 BOBBIN-SG B INF 3H +0.06 MRPC 4R DSIs SG B 23 39 DSI 2H -0.06 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 23 56 DSI 2H -0.06 BOBBIN i SG B INF 2H +0.00 MRPC'4R DSIs SG B 23 58 DSI 2H +0.00 BOBBIN-SG B INF 2H +0.00 MRPC 4R DSIs } SG B 23 71 DNG 2C +19.19 BOBBIN SG d 23 84 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 23 86 DSI 2H +0.00 BOBBIN

m t BWNS TUBAN II (Version.1.0) 10/22/1993 08:12:51 Beaver Valley Unit 2 t SG B 4R 9/93 i Page 10 of 16 STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN-ROW COL IND %TW LOCATION TEST TYPE i f SG B ODI 21 AV3 +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs { SG B 23 87 DSI 2H +0.05 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs ? SG B 24 8 DNG IH +21.08 BOBBIN SG B 24 30 DSI 3H +0.00 BOBBIN i SG B INF 3H +0.00 MRPC 4R DSIs t SG B 24 39 DSI 3H -0.06 BOBBIN SG B INF 3H -0.06 .MRPC 4R DSIs SG B 24 41 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 24 42 DSI 2H -0.06 BOBBIN. I SG B DSI 4H -0.09 BOBBIN SG B ODI 3 7C +44.55 BOBBIN SG B ODI 13 7C +43.39 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B INF 4H +0.00 MRPC 4R DSIs. SG B VOL 7C +44.50 to +* MRPC Special In SG B 24 47 DNG AV1 +2.07 BOBBIN [ SG B SAI AV1 +2.55 MRPC Special In SG B 24 49 DNG AV1 +11.06 BOBBIN i SG B INF AV2 +11.26 BOBBIN SG B SAI AVI +12.89 MRPC Special In SG B 24 50 DNG AV1 +10.53 BOBBIN SG B NQI AVI .+10.32 BOBBIN 1 SG B SAI AV1 +12.22 MRPC Special In SG B 24 53 INF 4H +0.00 BOBBIN [ SG B INF 4H +0.00 MRPC 4R DSIs SG B 24 58 DSI 3H +0.00 BOBBIN SG B INF 3H +0.00-MRPC 4R DSIs SG B 24 64 ADR SC +1.88 BOBBIN l SG B VOL SC +2.46 MRPC Special In SG B 24 65 INF 3H +0.00 BOBBIN s SG B INF 3H +0.00 MRPC 4R DSIs l SG B 24 66 DSI 2H +0.06 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs i SG B 24 68 DNG SC +28.67 BOBBIN. l SG B 24 75 DSI 3H +0.08 BOBBIN i SG B INF 3H +0.08 MRPC 4R DSIs SG B 24 78 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 24 79 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs' SG B 24 82 DSI 2H +0.08 BOBBIN SG B INF 2H +0.00 MRPC 4R.DSIs [ SG B 24 85 DSI 2H +0.06 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 25-13 DNG 6C +35.75 BOBBIN SG B 25 18 DNG 2H +18.91 BOBBIN SG B 25 20 DNG 3C +2.71 BOBBIN SG B PVN TSH +2.27 MRPC TSH SG B 25 28 DNG 2H +39.95 BOBBIN SG B 25 39 DSI 4H +0.00 BOBBIN-i SG B INF 4H +0.00 MRPC 4R DSIs SG B 25 40 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs i SG B 25-43 DSI 5H +0.00 BOBBIN ? l SG B DNG AV1 +2.72 BOBBIN SG B INF SH +0.00' MRPC 4R DSIs SG B SAI AVI +2.84 MRPC Special In l SG B 25 44 DNG AVI +3.13 BOBBIN 4 SG B SAI AVI +2.97 MRPC Special In SG B 25 46 DNG 2C- +33.54 BOBBIN i SG B -DNG AV1 +4.34 BOBBIN i SG B SAI-AV1 +4.63 MRPC Special In l J 5 1

s BWNS TUBAN II (Version 1.0) 10/22/1993 08:12:51 Beaver Valley Unit 2 j SG B l 4R 9/93 Page 11 of 16 STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 25 48 DNG 4C +18.59 BOBBIN SG B 25 49 DNG AV1 +12.02 BOBBIN SG B SAI AV1 +13.79 MRPC Special In .} SG B 25 53 INF 5H +0.00 MRPC 4R DSIs SG B 25 55 DNG 6C +10.60 BOBBIN SG B 25 56 PVN SH +36.07 BOBBIN SG'B.25 61 DNG 3C +40.07 BOBBIN SG B 25 65 DNG 7H +14.64 BOBBIN SG B 25 66 INF 2H +0.00 BOBBIN f SG B INF 2H +0.00 MRPC 4R DSIs SG B 25 74 DSI 3H +0.06 BOBBIN SG B PVN 3H -0.13 MRPC 4R DSIs SG B 26 29 ADR IH +21.20 BOBBIN-SG B VOL IH +21.60 MRPC Special In { SG B 26 31 DSI 3H +0.03 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs 'i SG B 26 33 DNG IC +18,38 BOBBIN SG B 26 36 DSI 2H -0.06 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 26 39 DSI 3H -0.09 BOBBIN I SG B INF 3H +0.00 MRPC 4R DSIs i SG B 26 42 DSI 3H -0.06 BOBBIN l SG B INF 3H +0.00 MRPC 4R DSIs SG B 26 45 DSI 3H -0.06 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 26 51 DSI 2H &O.09 BOBBIN SG B ADR TSC +6.25 BOBBIN t SG B INF 2H +0.09 MRPC 4R'DSIs l SG B VOL TSC +6.29 MRPC Special In l SG B 26 53 ADR SC +12.26 BOBBIN SG B VOL SC +12.26 MRPC Special In l SG B 26 56 DSI 2H +0.09 BOBBIN I SG B INF 2H +0.09- 'MRPC 4R DSIs f SG B 26 57 DSI 2H +0.00 BOBBIN i SG B INF 2H +0.00 MRPC 4R DSIs i SG B 26 59 ADR 7H +26.28 BOBBIN SG B INF 7H +26.29 MRPC Special In SG B 26 60 DSI 2H +0.00 BOBBIN i SG B DSI 3H +0.09 BOBBIN f SG B INF-2H +0.00 MRPC 4R DSIs SG B INF 3H +0.09 MRPC 4R DSIs SG B 26 62 DSI 3H +0.00 BOBBIN i SG B INF 3H +0.00 MRPC 4R DSIs SG B 26 68 DSI 5H +0.08 BOBBIN i SG B PVN SH +0.00 MRPC 4R DSIs l SG B 26 75 DNG SC +27.61 BOBBIN I SG B DSI 4H +0.00 BOBBIN. l SG B INF 4H +0.00 MRPC 4R DSIs SG B 27 22 DNG 4C +7.36 BOBBIN f SG B 27 44 DNG 2H +26.70 BOBBIN l SG B 27 64 PVN TSH +0.38 -MRPC TSH r SG B 27 65 DSI-4H +0.03 BOBBIN SG B INF 4H +0.03 MRPC 4R DSIs ~i SG B 27 67-DSI SH +0.09 BOBBIN. I SG B INF 5H +0.09 MRPC 4R DSIs '} SG B 27 74 ADR 2C +28.25 BOBBIN ) SG B VOL 2C +28.19 MRPC Special In SG B 28 25 DNG 3H- +42.26 BOBBIN SG B 28. 26 DNG. 1H +2.99 BOBBIN l SG B 28 27 DNG TSH +11.51 BOBBIN l SG B 28 28 DNG 4H +42.34 BOBBIN SG B 28 36 DNG AV1 +6.74 BOBBIN SG B SAI AV1 +7.11 MRPC Special In SG B 28-38 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs l

BWNS TUBAN'II (Version 1.0) 10/22/1993 08:12:51 i l Beaver Valley Unit 2 SG B jl 4R 9/93 Page 12 of 16 STEAH GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE .1 SG B 28 39 DSI 3H -0.05 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs j SG B 28 41 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 28 50 DSI 4H -0.06 BOBBIN i SG B INF 4H -0.06 MRPC 4R DSIs SG B 28' 53 DNG SC +31.58 BOBBIN f SG B 28 57 ADR 2C +21.81 BOBBIN SG B INF 2C +21.81 MRPC Special In [ SG B 28 68 DNG 4C +26.64 BOBBIN SG B DNG SC +25.69 BOBBIN l SG B DNG SC +26.39 BOBBIN SG B 28 71 DSI SH +0.12 BOBBIN SG B. INF 5H +0.12 MRPC 4R DSIs SG B 28 80 ADR 6C +23.25 BOBBIN SG B DSI 2H +0.12 BOBBIN SG B INF 2H +0.12 MRPC 4R DSIs j SG B INF 6C +23.36 MRPC Special In SG B 28 81 DSI 2H +0.06 BOBBIN l SG B INF 2H +0.00 MRPC 4R DSIs r SG B 29 27 DSI 3H +0.06 BOBBIN-r SG B INF 3H +0.06 MRPC 4R DSIs i SG B 29 29 DNG 4H +31.46 BOBBIN SG B DNG 6H +31.32 BOBBIN SG B DNG 7H +31.27 BOBBIN SG B 29 31 DSI SH -0.07 BOBBIN SG B INF SH +0.00 MRPC 4R DSIs i SG B 29 32 DSI 3H +0.00 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 29 33 DNG 2H +4.18 30BBIN SG B 29 37 DSI 3H -0.05 BOBBIN i SG B INF 3H +0.00 MRPC 4R DSIs SG B 29 40 DSI 3H +0.00 BOBBIN f SG B INF 3H +0.00 MRPC 4R DSIs. } SG B 29 41 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 29 44 DNG 6C +30.69 BOBBIN SG B 29 46 DNG 1C +4.72 BOBBIN SG B 29 55 IFF 3H +0.06 BOBBIN j SG B INF 3H +0.00 MRPC 4R DSIs i SG B 29 63 INF 2H +0.00 BOBBIN ) SG B INF 2H +0.00 MRPC 4R DSIs 't SG B 29 81 INF TEC. +14.79 MRPC Special In SG B 29 84 INF TEC +16.09 MRPC Special In. j SG B 30 20 DNG 4H +35.14 BOBBIN SG B 30 24 DSI 4H +0.06 BOBBIN { SG B INF 4H- +0.00 MRPC 4R DSIs SG B 30 32 DSI 3H +0.00 . BOBBIN i SG B 'INF 3H +0.00 MRPC 4R DSIs SG B 30 36 DNG BH +19.89 BOBBIN 'I SG B DNG BH +21.56 MRPC Special In i SG B 30 37 DNG-6H +44.83' BOBBIN i SG B DSI 3H -0.07 BOBBIN t SG B INF 3H +0.00 MRPC-4R DSIs. SG B 30 40 DSI 3H +0.05 BOBBIN -) SG B INF 3H +0.00 MRPC 4R DSIs. l SG B 30 43 ETL TSH -0.90 BOBBIN j SG B 30 44 DSI 4H +0.00 BOBBIN SG B DNT AV1 +0.00 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs.

5 SG B.

DNT AVI +0.77 MRPC Special In 'f SG B , SAI AV1 +3.36 MRPC Special.In-r SG B 30 49 DSI 2H -0.05 . BOBBIN i SG B INF 2H +0.00 MRPC 4R DSIs j SG B 30 52 DSI 2H +0.00 BOBBIN t ~...

BWNS TUBAN II (Version 1.0) '10/22/1993 08:12:51 Beaver. Valley Unit 2 SG B r l 4R 9/93 'I Page 13 of 16 STEAH GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE i SG B INF 2H +0.00 MRPC 4R DSIs SG B 30 64 INF 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 30 66 DRI TEC +12.42 BOBBIN SG B INF TEC +12.42 MRPC Special In i SG B 30 83 INF TEC +10.76 MRPC Special In l SG B 31 15 DNG 7H +21.69 BOBBIN SG B INF TEC +18.16 MRPC Special In SG B 31 17 ADR 3H +7.32 BOBBIN i SG B INF 3H +7.32 MRPC Special In l SG B 31 20 ADR 3H +26.77 BOBBIN ~ SG B VOL 3H +25.74 MRPC Special In r SG B 31 26 ADR 2C +12.64 BOBBIN. SG B VOL 2C +12.64 MRPC Special In i SG B 31 32 DSI 3H +0.06 BOBBIN l SG B INF-3H +0.06 MRPC 4R DSIs SG B 31 44 DNG 6H +10.34 BOBBIN 1 SG B 31 46 DNG 3H +1.25 BOBBIN i SG B 31 47 DSI 3H +0.08 BOBBIN i SG B INF 3H +0.08 MRPC 4R DSIs SG B 31 50 DNT TEH +10.70 BOBBIN { SG B 31 53 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 31 54 DNT TEH +9.69 BOBBIN SG B 31 55 DSI 2H +0.08 BOBBIN -SG B INF 2H +0.08 MRPC 4R DSIs SG B 32 20 DNG 6H +9.74 BOBBIN SG B 32 33 DNG 3H +19.65 BOBBIN SG B 32 41 ADR SC +36.02 BOBBIN l SG B VOL SC +36.02 MRPC Special In SG B 32 44 PVN TSH -3.40 MRPC TSH -f SG B 32 59 ETL TSC +1.37-BOBBIN SG B 33 32 DSI 2H +0.13 BOBBIN SG B INF 2H -0.01 MRPC 4R DSIs-SG B 33 35 DSI 3H +0.08 BOBBIN l SG B INF 3H +0.00 MRPC 4R DSIs SG B 33 41 ODI 17 AV2 +0.00 BOBBIN -i SG B 33 57 ODI 15 AV2 +0.00 BOBBIN 'l SG B 33 58 ADR 2C +10.79 BOBBIN SG B INF 2C +10.79 MRPC Special In SG B 33 60 DSI 2H +0.06 BOBBIN SG B INF 2H +0.06 MRPC 4R DSIs SG B 33 62 ADR 3C +36.48 BOBBIN l SG B VOL 3C +36.48 MRPC Special In SG B 33 63 ODI 30 AV2 +0.00 BOBBIN i SG B 33 68 DNG AV2 +6.77 BOBBIN i SG B SAI AV2 +7.72 MRPC Special In SG B 33 75 DSI 2H- +0.06 BOBBIN SG B INF 2H +0.06 MRPC 4R DSIs -( SG B 33 79 ADR 6C +37.2F BOBBIN SG B VOL 6C +37.25' MRPC Special In SG B 34 31'ADR 6H +20.71 BOBBIN SG B - VOL 6H +20.13 MRPC Special In SG B 34 35 ADR 'AV2 +8.50 BOBBIN SG B VOL AV2 +9.87 MRPC Special In i SG B 34 50 DNG TSC +11.00 BOBBIN-L SG B ODI 20 AV1 +0.00 BOBBIN SG B 34 55 ODI 19 6H +2.73 BOBBIN SG B ODI 22 AV3 +0.00 BOBBIN SG B VOL 6H +2.63 MRPC Special In SG B VOL 6H +2.53 MRPC Special In SG B 34 60 ADR-AV4 +10.73 BOBBIN a SG B INF AV4 +10.73 MRPC Special In SG B 34 61'DSI 2H +0.09 BOBBIN i SG B INF 2H +0.00 MRPC 4R DSIs o )

J**************** BWNS TUBAN II (Version 1.0) 10/22/1993 08:12:51 Beaver Valley Unit 2 SG B 4R 9/93 ? Page 14 of 16 STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 34 62 DSI 5H +0.09 BOBBIN SG B INF SH +0.00 MRPC 4R DSIs SG B 35 25 ODI 16 AV2 +0.00 BOBBIN SG B ODI 20 AV3 +0.00 BOBBIN i SG B 35 29 DSI 5H +0.10 BOBBIN SG B INF 5H +0.00 MRPC 4R DSIs j SG B 35 30 ODI 26 7H +25.92 BOBBIN SG B VOL 7H +25.92 MRPC Special In [ SG B 35 34 DSI SH +0.00 BOBBIN SG B INF 5H +0.00 MRPC 4R DSIs SG B 35 40 DSI 2H +0.00 BOBBIN i SG B INF 2H +0.00 MRPC 4R DSIs l SG B 35 41 ODI 13 AV1 +0.00 BOBBIN SG B ODI 14 AV2 +0.00 BOBBIN SG B ODI 19 AV4 +0.00 BOBBIN SG B 35 45 DSI SH +0.06 BOBBIN SG B INF SH +0.00 MRPC 4R DSIs SG B 35 50 ODI 12 AV2 +0.00 BOBBIN SG B ODI 15 AV1 +0.00 BOBBIN -l SG B ODI 19 AV3 +0.00 BOBBIN SG B 35 55 ODI 23 AV3 +0.00 BOBBIN SG B 35 62 DRI TEC +10.36 BOBBIN SG B INF TEC +10.35 MRPC Special In SG B 35 67 DRI TEC +10.45 BOBBIN ~; SG B INF TEC +10.45 MRPC Special In SG B 35 7 Fe DTI TSC +0.24 BOBBIN f SG B PLP TSC +0.18 MRPC Special In SG B 36 18 DSI 3H +0.03 BOBBIN ~~ ; SG B ODI 18 6H +2.83 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B PVN 6H -0.60 MRPC Special In SG B PVN 6H- -0.87 MRPC Special In. SG B VOL 6H +2.38 MRPC Special In 3 SG B 36 25 PVN TSH -2.23 MRPC TSH J SG B 36 35 ODI 2 6C +22.85 BOBBIN + SG B VOL 6C +23.29 MRPC Special In SG B 36 41 ODI 21 AV3 -0.03 BOBBIN = f SG B ODI 22 AV2 +0.00 BOBBIN SG B ODI 26 AVI +0.00 BOBBIN i SG B 36 42 DSI 2H +0.05 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs SG B 36 45 DNG IC +17.41 BOBBIN SG B 36 48 DSI 4H +0.00 BOBBIN SG B INF 4H +0.00 MRPC 4R DSIs v SG B 36 59 ADR 2H +33.09 BOBBIN SG B DSI 3H +0.09 BOBBIN 1 SG B INF 3H +0.09 MRPC 4R DSIs SG B VOL 2H +33.09 MRPC Special In l 6 SG B 36 63 ODI 14 AV2 +0.00 BOBBIN SG B 36 64 DNG 4H +14.96 BOBBIN I SG B 36 76 DTI TSC +0.33 BOBBIN SG B PLP TSC +0.22 MRPC Special In SG B SAI TSC +0.21 MRPC Special In 'l SG B 36 77 DTI TSC +0.28 BOBBIN SG B PLP TSC 40.27 MRPC Special In SG B SAI TSC +0.28' MRPC Special In SG B 37 20 DNG 6H +38.54 BOBBIN SG B DNG 7H +46.99 BOBBIN SG B DNG 7H +31.41 BOBBIN SG B DNG 7H +45.73-BOBBIN SG B DNG 7H +39.31 BOBBIN SG B DNG 7H +45.10 BOBBIN SG B DNG 7H +38.59 BOBBIN SG B 37 26 DSI 3H +0.14 BOBBIN [ SG B INF 3H +0.00 MRPC 4R DSIs

r t 'BWNS TUBAN II-(Version 1.0) 10/22/1993 08:12:51 ' Beaver Valley Unit 2 SG B 4R 9/93 Page 15 of 16 STEAM GENERATOR B (2RCS-SG21B) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG B 37 28 ETL TSC -1.89 BOBBIN i SG B-INF TSC -1.05 MRPC Special In } SG B 37 32 ETL TSC -1.71 BOBBIN ? SG B INF TSC -0.76 MRPC Special In SG B 37 42 ADR SC +39.57 BOBBIN SG B INF 6C -11.00 MRPC Special In SG B 37 49 DSI 2H -0.03 BOBBIN SG B DSI 4H +0.06 BOBBIN SG B INF .2H +0.00 MRFC 4R DSIs e SG B INF 4H +0.00 MRPC 4R DSIs SG B 37 57 ODI 20 AV4 +0.00 BOBBIN SG B 37 62 DSI 2H +0.06 BOBBIN l SG B INF 2H +0.00 MRPC 4R DSIs SG B 38 28 ODI 11 6H +4.26 BOBBIN SG B VOL 6H +4.26 MRPC Special In SG B 38 31 DSI 5H +0.03 BOBBIN SG B INF 5H +0.00 MRPC 4R DSIs SG B 38 35 DSI 2H +0.00 BOBBIN SG B INF 2H +0.00 MRPC 4R DSIs i SG B 38 37 DSI 3H +0.06 BOBBIN SG B INF 3H +0.00 MRPC 4R DSIs SG B 38 59 ODI 13 4H +14.49 BOBBIN i SG B VOL 4H +14.68 MRPC Special In SG B 38 60 DNG 6H +28.78 BOBBIN 7 SG B 38 61 DNG 2H +7.05 BOBBIN SG B 38 68 DNG IH +5.41 BOBBIN SG B DNG IH +4.71 BOBBIN SG B 39 24 DTI TSH +0.49 BOBBIN SG B PLP TSH +0.27 MRPC TSH SG B 39 25 DTI TSH +0.40 BOBBIN SG B PLP TSH +0.19 MRPC TSH + SG B 39 33 DNG 2H +3.77 BOBBIN SG B 39 62 DNG TSC +12.40 . BOBBIN t SG B 39 63 DNG 4H +28.09 BOBBIN SG B DNG TSC +13.56 BOBBIN SG B. DNG TSC +14.45 BOBBIN SG B 39 68 DNG IC +1.78 BOBBIN SG B DNG IC +1.05 BOBBIN-SG B 39 70 ODI 22 AV3 +0.00 BOBBIN SG B 40 24 DTI TSH +0.46 BOBBIN. SG B PLP TSH +0.24 .MRPC TSH SG B 40 33 DNG TSH +14.17 BOBBIN SG B 40. 39 DNG TSC -+7.83 BOBBIN SG B 40 40 DNG. 1H +4.25 BOBBIN' i SG B DNG IH +4.87 BOBBIN .SG B 40 41 DNG BH +0.00 BOBBIN-SG B INF' 8H +1.32 MRPC Special In. l SG B 40 63 ADR IC +6.85 BOBBIN I SG B VOL IC +6.85-MRPC Special In SG B 40 69 DSI 4H +0.06 BOBBIN SG B INF 4H- +0.00 MRPC 4R DSIs SG B 41 35 ETL TEC +6.72 BOBBIN SG B INF. TEC +6.72 MRPC Special In f SG'B 41 38 ADR 2C +44.00 BOBBIN-SG B' VOL 2C +44.00 MRPC Special In SG B 41 46 DNG SH .+10.58 BOBBIN .I +18.85 BOBBIN SG B 41 49 DRI TEH SG B INF TEH +10.58 -MRPC Special In SG B 42 28 DNT SC -0.44 BOBBIN l SG B DNT 8C +0.28 BOBBIN i SG B DNT BH -0.47 BOBBIN SG B DNT BC -0.43 .MRPC Special In SG B DNT' 8C +0.39 MRPC Special In. SG B 42 29 DNT 8C -0.47 BOBBIN ? SG B 42 51 DSI-4H +0.09 BOBBIN l

~ l ? 10/22/1993 08:12:51 (Version 1.0) ley Unit 2'

      • =************

BWNS TUBAN II Beaver Val t SG B

        • e....*******

4R 9/93 e**e 't i Page 16 of 16 STEAH GENERATOR B (2RCS-SG21B) i 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE + SG B INF 4H +0.00 MRPC 4R DSIs SG B 43 40 DNG IH +6.03 BOBBIN SG B DNG IH +6.66 BOBBIN SG B DNG TSC +3.08 BOBBIN SG B DNG TSC +3.72 BOBBIN SG B 43 41 ODI 6 2H +17.65 BOBBIN SG B VOL 2H +17.65 .HRPC Special In SG B 43 61 DNG 4H +28.20 BOBBIN SG B 44 42 DNG 3C +29.27 BOBBIN i SG B 44 56 DNG IH +8.06 BOBEIN SG B DNG IH +7.31 BOBBIN SG B DNP 2H +28.36 BOBBIN SG B .e.. 2H +29.13 BOBBIN i SG B VG TSH +16,87 BOBBIN i' SG B 44 57 r%. IC +16.01 BOBBIN SG B DNG BC +1.03 BOBBIN SG B DNG BC +1.34 MRPC Special In SG B DNT 80 +0.58 MRPC Special In SG B 44 5B DNT 8C +0.37 BOBBIN i SG B DNT 8C +0.44 MRPC Special In SG B 44 52 DNG IH -0.95 BOBBIN SG B DNG SH +36.60 BOBBIN SG B DNT SC +0.41 BOBBIN SG B DNT BC +0.44 MRPC Special In [ SG B 44 60 DNG IC +7.57 BOBBIN SG B DNG IC +6.86 BOBBIN SG B 44 62 DNG 6H +6.55 BOBBIN SG B 45 50 USI 4H +0.03 BOBBIN l SG B INF 4H +0.00 MRPC 4R DSIs -r SG B 45 57 DNT 4C +0.39 BOBBIN SG B DNT 8C +0.39 BOBBIN. m SG B DNT BC +0.55 MRPC Special In SG B 45 58 DNT 4C +0.48 BOBBIN SG B DNT 8C +0.39 BOBBIN SG B DNT 8C +0.59 MRPC Special In i SG B 45 59 DNT 4C +0.45 BOBBIN SG B DNT 8C +0.40 BOBBIN -l SG B DNT BC +0.57 MRPC Special.In Total Indications Found = 1013 Total Tubes Found = 508 r 9 ? ? l

'ee.......e**en.*- .BWNS TUBAN II (Version 1.0) 10/22/1993 09:22:37. I t Beaver. Valley Unit 2 I SG B 4R 9/93 l =t f t Page 1 of 1 STEAM GENERATOR B (2RCS-SG21B) 4R PLUGGED T*JBES GEN ROW COL IND %TW LOCATION TEST TYPE SG B 1 59 SAI BH +3.54 MRPC U-Bend SG B 7 47 DNT 2C +3.73 BOBBIN-SG B 9 82 DSI 4H +0.08 BOBBIN SG B EPI TSH +7.42 BOBBIN l SG B 12 31 DSI 3H -0.06 BOBBIN 't SG B ODI 53 7C +33.01 BOBBIN SG B 19 46 DSI 2H -0.03 BOBBIN SG B VOL 2H +0.18 MRPC 4R DSIs SG B 21 82 ODI 49-TSC +0.69 BOBBIN l SG B VOL TSC +0.66 MRPC Special In-l SG B 21 83 ODI 28 TSC +0.63 BOBBIN ~ SG S PLP TSC +0.45 MRPC Special In SG B 21 84 EPI TSH +7.14 BOBBIN SG B 24 47 DNG AVI +2.07 BOBBIN SG B SAI AV1 +2.55 MRPC Special In SG B 24 49 DNG AV1 +11.06 BOBBIN SG B SAI AV1 +12.99 MRPC Special'In SG B 24 50 DNG AV1 +10.53 BOBBIN SG B NQI AVI +10.32 BOBBIN t SG B SAI AV1 +12.22 MRPC Special In j SG B 25 43 DSI 5H +0.00 BOBBIN SG B DNG AVI +2.72 BOBBIN SG B SAI AV1 +2.84 MRPC Special In SG B 25 44 DNG AV1 +3.13 BOBBIN l SG B SAI AV1 +2.97 MRPC Special In SG B 25 46 DNG 2C +33.54 BOBBIN l SG B DNG AV1 +4.34 BOBBIN ) SG B SAI AV1 +4.63 MRPC Special In { SG B 25 49 DNG AV1 +12.02 BOBBIN SG B SAI AV1 +13.79 MRPC Special In l SG B 28 36 DNG AV1 +6.74 ' BOBBIN SG B SAI AVI +7.11 MRPC Special In f SG B 30 36 DNG BH +19.89 BOBBIN SG B DNG 3H +21.56 MRPC Special In l SG B 30 44 DSI 4H +0.00 BOBBIN SG B DNT AVI +0.00 BOBBIN 5 SG B DNT AVI +0.77 MRPC Special In SG B SAI AVI +3.36 MRPC Special In SG B 33 68 DNG AV2 +6.77 BOBBIN i SG B SAI AV2 +7.72 MRPC Special In l SG B 35 76 PLP TSC +0.18 MRPC Special In SG B 36 76 PLP TSC +0.22 MRPC Special In SG B SAI TSC +0.21 MRPC Special In SG B 36 77 PLP TSC +0.27 MRPC Special In e SG B SAI TSC +0.28 MRPC Special In-SG B 39 24 PLP TL1 +0.27 MRPC TSH t SG B 39 25 PLP TSH +0.19 MRPC TSH L SG B 40 24 PLP TSH +0.24 MRPC.TSH l Total Indications Found = 48 Total Tubes Found = 25 Total Tubes in Input File = 25 1 ) t 1

ATTACHMENT 6 CSIT #2 1 CH REFC3 LING OLTAGE I STEAM GENERATOR "C" (2RCS-SG21C,'l [ 1 i

            • =*********,

BWNS TUBAN II (Version 1.0) 10/26/1993 09:38:37 Beaver Valley Unit 2 SG C 4R 9/93 l. Page 1 of 18 STEAM GENERATOR C (2RCS-SG21C) 4R INDICATILAS i GEN ROW COL IN; %TW LOCATION TEST TYPE SG C 1 26 ODI. 10 4H +33.69 BOBBIN ~ SG C VOL 4H +33.69 MRPC Special In SG C 1 38 DSI 2H +0.10 BOBBIN SG C VOL 2H -0.06 MRED 4R DS's SG C 1 40 ODI 12 2C +31.36 BOBBIN-SG C VOL 2C +31.37 MRPC Special In j SG C 1 58 DNG 6H +12.11 BOBBIN SG C 2 11 ODI 25 2H +46.29 BOBBIN SG C INF 2H +46.29 MRPC Special In I SG C 2 12 ODI 9 2H +34.76 BOBBIN SG C VOL 2H +34.60 MRPC Special In. SG C 2 15 ODI 2 6H +25.34 BOBBIN SG C VOL 6H +25.94 MRPC Special In SG C 2 16 DSI 3H -0.08 BOBBIN SG C INF 3H +0.00 MRPC 4R Is r SG C 2 18 DSI 5H -0.03 BOBBIN l SG C INF 5H +0.00 HRPC 4R DSIs SG C 2 20 INF 3H +0.00 MRPC 4R DSIs .JC 2 21 ADR SC +13.01 to +* BOBBIN l SG C INF SC +13.01 to +* MRPC Special In i SG C 2 32 INF 3H +0.00 MRPC 4R DSIs. SG C 2 37 INF 2H +0.00 MRPC 4R DSIs SG C 2 38 INF 2H +0.00 MRPC 4R DSIs l SG C 2 41 INF 2H +0.00 MRPC 4R DSIs SG C 2 73 INF 5H +0.00 MRPC 4R DSIs SG C 2 78 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 2 85 DSI 3H -0.08 BOBBIN SG C INF 3H -0.08 MRPC 4R DSIs SG C 2 89 ODI 4 4H +45.96 BOBBIN SG C VOL 4H +45.95 MRPC Special In l SG C 3 1 DNG 7H +27.33 BOBBIN SG C DNG 7H +16.64 BOBBIN SG C DNG 7H +21.43 BOBBIN SG C DNG 7H +20.97 BOBBIN SG C 3 17 DNG 6C +48.47 BOBBIN SG C 3 18 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 3 23 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 3 30 DNG BH +11.77 BOBBIN SG C INF BH +11.77 MRPC Special In SG C 3 34 INF 2H +0.00 MRPC 4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs SG C 3 35 DSI SH -0.04 BOBBIN SG C INF 5H -0.04 MRPC 4R DSIs i SG C 3 42 DSI SH +0.00 BOBBIN SG C INF 5H +0.00 HRPC 4R DSIs SG C 3 53 DNG 4C +14.73 BOBBIN SG C 3 56 DNG TSC +4.42 BOBBIN SG C 3 60 DSI 2H +0.04 BOBBIN' SG C INF 2H +0.04 MRPC 4R DSIs SG C 3 70 DSI 3H -0.03 BOBBIN SG C INF 3H -0.03 MRPC 4R DSIs SG C 3 71.DNG 6C +36.58 BOBBIN SG C 3 87 DNG OTHER BOBBIN SG C DNG OTHER BOBBIN SG C 3 89 DNG TSH +15.52 BOBBIN. SG C DNG TSH +7.02 BOBBIN SG C DNG TSH +7.83 BOBBIN SG C 4 8 DSI 3H -0.02 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs i SG C 4 12 DSI 3H +0.05 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 4 23 DSI 3H -0.06 BOBBIN l r

-) BWNS TUBAN II (Version 1.0) 10/26/1993 09:38:37 g Beaver Valley Unit 2

  • ee*************

SG C 4R 9/93 i Page 2 of 18-l STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE l SG C INF 3H -0.06 MRPC 4R DSIs .I SG C 4 24 DNG 6C +6.15 BOBBIN SG C 4 27 INF 3H +0.00 MRPC 4R DSIs SG C 4 31 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 4 33 DSI 2H +0.02 BOBBIN SG C INF 2H +0.02 MRPC 4R DSIs SG C 4 36 INF 2H +0.00 MRPC 4R DSIs + SG C 4 37 INF 2H +0.00 MRPC 4R DSIs SG C INF 4H +0.00 MRPC 4R DSIs SG C INF 5H +0.00 MRPC 4R DSIs SG C 4 44 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC.4R DSIs i SG C 4 51 DSI 2H +0.10 BOBBIN SG C INF 2H +0.10 MRPC 4R DSIs SG C 4 60 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 4 71 DNG 6H +43.33 BOBBIN SG C 5 1 ETL TSC +1.42 BOBBIN SG C 5 8 DSI 2H +0.02 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 5 10 INF 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C INF 4H +0.00 MRPC 4R DSIs SG C INF SH +0.00 MRPC 4R DSIs SG C 5 12 DSI 4H +0.07 BOBBIN SG C INF 4H +0.00 MRPC 4R DSIs SG C 5 18 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 5 20 DNG 7H +29.33 BOBBIN SG C DNG 7H +29.81 BOBBIN SG C DNG 7H +28.68 BOBBIN SG C 5 24 INF 2H +0.00 MRPC 4R DSIs SG C 5 25 DSI 4H -0.08 BOBBIN SG C INF 4H -0.08 MRPC 4R DSIs SG C 5 37 USI 2H +0.00 BOBBIN l SG C INF 2H +0.00 MRPC 4R DSIs SG C 5 40 DSI 5H +0.04 BOBBIN i SG C INF 5H +0.04 MRPC 4R DSIs SG C 5 44 DSI 5H +0.00 BOBBIN i SG C INF SH +0.00 MRPC 4R DSIs SG C 5 48 DSI 3H -0.10 BOBBIN SG C INF 3H -0.10 MRPC 4R DSIs SG C 5 55 DSI 2H +0.06 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 5 89 DNG 2H +19.79 BOBBIN SG C 5 94 DNG 8H +10.58 BOBBIN SG C DNG 8H +16.76 BOBBIN SG C INF BH +I0.58 MRPC Special In SG C INF BH +16.76 MRPC Special In SG C 6 19 DSI 6H +0.05 BOBBIN SG C INF 4H +0.00 MRPC 4R DSIs SG C INF 6H +0.00 MRPC 4R DSIs t' SG C 6 23 DSI 2H -0.04 BOBBIN SG C DSI 3H +0.02 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs SG C 6 24 DNG 6C +32.45 BOBBIN SG C 6 26 INF 2H +0.00 MRPC'4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs SG C 6 27 DSI 3H -0.04 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 6 31 DSI 2H +0.02 BOBBIN SG C INF 2H +0.02 MRPC 4R DSIs SG C 6 35 DSI 4H +0.00 BOBBIN i

                                • ~

'BWNS TUBAN II.(Version 1.0) 10/26/1993 09:38:37 Beaver Valley Unit 2 SG C. 4R 9/93 t Page 3 of IB STEAM GENERATOR ~C (2RCS-SG21C) GEN ROW O IND %TW LOCATION TEST TYPE SG C DSI 6H -0.04 BOBBIN SG C INF 4H +0.00' MRPC 4R DSIs i SG C INF 6H -0.04 MRPC 4R DSIs SG C 6 46 DSI 5H -0.08 BOBBIN SG C INF 5H -0.08 MRPC 4R DSIs i SG C 6 55 DSI 2H +0.06 BOBBIN i SG C INF 2H +0.06 MRPC 4R DSIs' SG C 6 71 DNG 7H -1.43 BOBBIN SG C 7 1 DNG IC +7.75 BOBBIN SG C DNG IC +4.51 BOBBIN SG C DNG IC +6.04 BOBBIN SG C DNG IC 46.81 BOBBIN SG C DNG IC +5.45 BOBBIN' SG C DNG IC +6.46 BOBBIN SG C DNG IC +4.98 BOBBIN SG C DNT 4H -0.27 BOBBIN. SG C 7 20 DSI 2H -0.13 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 7 27 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 7 28 DSI 3H -0.04 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 7 30 ODI 10 2H +1.17 ' BOBBIN SG C INF 2H +1.17 MRPC Special In l SG C 7 37 DSI SH +0.00 ' BOBBIN SG C 'INF 5H +0.00 MRPC 4R DSIs-SG C 7 39 INF 2H +0.00 MRPC 4R DSIs SG C 7 40 DSI 3H -0.02 BOBBIN-SG C INF 2H +0.00 MRPC 4R DSIs SG C INF 3H -0.02 MRPC 4R DSIs-SG C INF 5H +0.00 MRPC 4R DSIs ') SG C 7 42 DSI 5H +0.00 BOBBIN SG C INF SH +0.00 MRPC 4R D3Is SG C 8 8 DSI 3H +0.12 BOBBIN SG C DSI 4H +0.05 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs. i SG C INF 4H +0.00 MRPC 4R DSIs SG C 8 11 DSI 2H +0.05 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 8 19 ODI 15 7H +1.22-BOBBIN ~ 'i SG C VOL 7H +1.32 MRPC Special In SG C 8 22 DSI 3H -0.12 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 8 23 DSI 2H -0.06 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 8 30 INF 3H +0.00 MRPC 4R DSIs SG C 8 36 DSI 2H -0.06 BOBBIN SG C INF 2H -0.06 MRPC 4R DSIs SG C 8 42 INF 4H +0.30 MRPC 4R DSIs t SG C 8 45 DSI 4H -0.04 BOBBIN SG C INF 4H -0.04 MRPC 4R DSIs SG C 8 54 DSI 3H +0.12 -BOBBIN SG C INF 3H +0.12 MRPC 4R DSIs SG C 8 59 DSI 2H +0.06 BOBBIN ~ SG C INF 2H +0.06 MRPC 4R DSIs SG C 8 75 ODI 8 4C +43.41 BOBBIN i SG C NQI 4C +45.67 MRPC Special In SG C VOL 4C +43.01 MRPC Special In SG C 8 79 DSI 3H +0.05 BOBBIN SG C INF 3H +0.05 MRPC 4R DSIs SG C 8 87 DSI 3H +0.05 BOBBIN SG C INF 3H +0.05 MRPC 4R DSIs SG C 8 88 ODI 15 2H +11.59 BOBBIN SG C VOL 2H +11.43 MRPC Special In I SG C 9 4 DSI 3H +0.09 BOBBIN t 5 u% - -

] i BWNS TUBAN-'II (Version'1.0)- 10/26/1993 09:38:37 - Beaver Valley Unit 2 SG C 4g 9/93 Page 4 of 18 i STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE e SG C INF 3H +0.00 MRPC 4R DSIv' SG C 9 6 DSI 3H +0.07 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 9 13 INF 2H +0.00 MRPC 4R DSIs SG C 9 14 DSI 2H +0.02 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 9 16 DSI 3H +0.00 BOBBIN-SG C INF 3H +0.00 MRPC 4R DSIs SG C 9 19 DSI 4H +0.05 BOBBIN SG C INF 4H +0.00 MRPC 4R DSIs SG C 9 24 DSI 5H -0.06 BOBBIN SG C INF SH +0.00 MRPC 4R DSIs SG C 9 27 INF 2H +0.00 MRPC 4R DSIs SG C 9 32 DSI 2H +0.02 BOBBIN SG C INF 2H +0.02 MRPC 4R DSIs SG C 9 34 DSI 3H -0.06 BOBBIN SG C INF 3H -0.06 MRPC 4R DSIs SG C 9 35 DSI 2H -0.13 BOBBIN SG C INF 2H -0.13 MRPC 4R DSIs I SG C 9 38 DSI 3H -0.04 BOBBIN SG C INF 3H -0.04 MRPC 4R DSIs SG C 9 40 DSI 4H +0.00 BOBBIN SG C INF 4H +0.00 MRPC 4R DSIs SG C 9 41 DSI 2H -0.02 BOBBIN SG C DSI 5H +0.02 BOBBIN i SG C INF 2H -0.02 MRPC 4R DSIs SG C INF 5H +0.02 MRPC 4R DSIs SG C 9 43 DSI '2H -0.02 BOBBIN 'j SG C INF 2H -0.02 MRPC 4R DSIs SG C 9 45 DSI 5H -0.04 BOBBIN SG C INF 5H -0.04 MRPC 4R DSIs i SG C 9 46 DSI 3H -0.02 BOBBIN SG C INF 3H -0.02 MRPC 4R DSIs SG C 9 47 DSI 2H -0.13 BOBBIN SG C INF 2H -0.13 MRPC 4R DSIs SG C 9 48 DNG 6C +41.83 BOBBIN l SG C DSI 2H -0.02 BOBBIN SG C DSI 3H +0.02 BOBBIN SG C INF 2H -0.02 MRPC 4R DSIs SG C INF 3H +0.02 MRPC 4R DSIs SG C 9 49 DNG 3C +35.09 BOBBIN SG C 9 51 DNC 7H +26.16 BOBBIN SG C 9 83 DSI 2H +0.02 BOBBIN SG C INF 2H +0.02 MRPC 4R DSIs SG C 10 9 DSI 3H +0.09 BOBBIN SG C INF 3H +0.09 MRPC 4R DSIs-SG C 10 22 DSI 3H +0.08 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 10 24 DSI 3H -0.06 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 10 25 ODI 12 SC +21.13 BOBBIN - SG C INF 3H +0.00 MRPC 4R DSIs SG C INF SC +21.13 MRPC Special In SG C 10 33 DSI 2H +0.02 BOBBIN SG C DSI 4H -0.06 BOBBIN SG C INF 2H +0.02 MRPC 4R DSIs l SG C INF 4H -0.06 MRPC 4R DSIs SG C 10 35 DSI 5H -0.02 BOBBIN SG C INF 5H -0.02 MRPC 4R DSIs SG C 10 38 DSI 3H +0.02 BOBBIN SG C DSI 7H -0.11 BOBBIN SG C INF 3H +0.02 MRPC 4R DSIs SG C INF 7H -0.11 MRPC 4R DSIs i SG C 10 40 DSI 3H

  • 0.00 BOBBIN I

SG C INF 3H +0.00 MRPC 4R DSIs .e

j 10/26/1993 09:38:37-BWNS TUBAN II'(Version 1.0) ley Unit 2 =****************' r Beaver. Val +*************** SG C 4R 9/93 .i l l; Page 5 of 18 l STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW. COL IND %TW LOCATION TEST TYPE i SG C 10 <42 DSI 2H -0.04 BOBBIN. SG C-INF 2H -0.04 MRPC 4R DSIs SG C 10 43 INF 2H +0.00 .MRPC 4R DSIs P SG C 10 47 DSI 3H +0.08 BOBBIN f SG C INF 3H +0.00 MRPC 4R DSIs SG C' INF 4H +0.00 MRPC 4R DSIs i SG C 10 84 DNT TEH +15.64 BOBBIN SG C 10 89 DNG IC +21.98 BOBBIN i SG C 11 6 NQI 2C +4.04 BOBBIN SG C VOL 2C +4.19 MRPC Special In SG C 11 13 DSI 3H +0.05 BOBBIN [ SG C INF 3H +0.05 MRPC 4R DSIs i SG C 11 20 DSI SH -0.06 BOBBIN i SG C INF 5H +0.00 MRPC 4R DSIs SG C 11 22 DSI 4H +0.00 BOBBIN l SG C INF 4H +0.00 MRPC 4R DSIs i SG C 11 34 DSI 3H +0.02 BOBBIN i SG C INF 3H +0.02 MRPC 4R DSIt SG e 11 3B DSI 3H -0.10 30BBIN SG C INF 3H -0.10 -MRPC 4R DSIs 1! SG C 11 39 INF 4H +0.00 MRPC 4R DSIs SG C 11 40 DSI 3H -0.06 BOBBIN l SG C VOL 3H -0.06 MRPC 4R DSIs SG C 11 43 DSI 3H -0.02 BOBBIN SG C DSI SH +0.00 BOBBIN e SG C INF 3H -0.02 MRPC 4R DSIs SG C INF SH +0.00 MRPC 4R DSIs I SG C 11 44 DNG 7C +32.11 BOBBIN [ SG C DNG 7C +31.34 BOBBIN SG C DNG 7H +25.91 BOBBIN i SG C DNG 7H +25.18 BOBBIN SG C 11 45 DSI 5H -0.04 BOBBIN SG C INF 5H -0.04 MRPC 4R DSIs SG C 11 56 ODI 5 TSC +7.22 BOBBIN j SG C INF TSC +7.22 MRPC Special In r SG C 11 66 DNG TSC +15.26 BOBBIN I' SG C 11 70 DSI 2H -0.07 BOBBIN SG C INF 2H -0.07 MRPC 4R DSIs SG C 11 72 DSI 2H -0.07 BOBBIN i SG C DSI 3.H -0.05 BOBBIN SG C INF 2H -0.07 MRPC 4R DSIs 'i SG C INF 3H +0.00 MRPC 4R DSIs -r SG C INF 3H -0.05 MRPC 4R DSIs i SG C 11 76 ADR 4H +10.65 BOBBIN SG C INF 4H +10.65 MRPC Special In SG C 12 4 NQI TSH +5.55 BOBBIN SG C DNG TSH +5.01 MRPC Special In ] SG C 12 5 DNG TSC +2.07 BOBBIN SG C 12 30 DSI 2H -0.02 BOBBIN l SG C INF' 2H -0.02 MRPC 4R DSIs l SG C 12 31 INF 2H +0.00 MRPC 4R DSIs i SG C INF 5H +0.00 MRPC 4R DSIs SG C 12 34 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 12' .35 DSI 5H +0.02 BOBBIN SG C INF 5H +0.02 MRPC 4R DSIs' SG C 12 37 DSI -3H +0.00 BOBBIN SG C DSI 6H -0.08 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C INF 6H -0.08 MRPC 4R DSIs SG C 12 38 DSI 2H -0.06 BOBBIN SG C DSI 3H -0.0B BOBBIN SG C INF 2H -0.06 MRPC 4R DSIs SG C INF 3H -0.08 MRPC 4R DSIs SG C 12 40 DNG 2H +21.80 BOBBIN i t a-. -n.

BWNS.TUBAN-II (version 1.0)- 10/26/1993 09:38:37 Beaver Valley Unit-2 SG C 4R 9/93 Page 6 of.18 STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C DSI 3H -0.08 BOBBIN SG C INF 3H -0.08 MRPC 4R DSIs SG C 12 42 DSI 3H -0.08 BOBBIN. SG C INF 3H 40.00 MRPC 4R DSIs' SG C 12 43 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 12 44 DSI 3H +0.00 BOBBIN SG C VOL 3H +0.51 MRPC 4R DSIs-SG C 12 53 DSI 4H +0.00 BOBBIN SG C INF 4H +0.00 MRPC 4R DSIs SG C 12 71 DNG OTHER BOBBIN SG C 12 80 DSI 3H +0.06 BOBBIN. SG C INF 3H +0.06 MRPC 4R DSIs SG C 12 83 DSI 3H +0.06 BOBBIN SG C INF 3H +0.06 MRPC 4R DSIs SG C 13 5 DRI TEC +4.53 BOBBIN SG C INF TEC +4.53 MRPC Special In SG C 13 9 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 13 19 DSI 3H +0.03 BOBBIN SG C INF 3H +0.03 HRPC 4R DSIs SG C 13 20 DSI 5H -0.04 BOBBIN. SG C INF SH +0.00 MRPC 4R DSIs SG C 13 25 DNT IC -0.54 BOBBIN SG C 13 30 INF 4H +0.00 BOBBIN SG C INF 4H +0.00 11RPC 4R DSIs SG C 13 32 DSI 5H +0.00 BOBBIN SG C INF 5H +0.00 MRPC 4R DSIs SG c 13 34 ADR 2H +7.89 BOBBIN SG C VOL 2H +7.97 MRPC Special In SG C 13 36 DNG 2H +22.26 BOBBIN SG C DSI 3H -0.13 BOBBIN SG C 'INF 3H -0.13 MRPC 4R DSIs SG C 13 37 DSI 4H +0.04 BOBBIN SG C INF 4H +0.04 HRPC 4R DSIs SG C 13 38 DSI 3H -0.06 BOBBIN SG C INF 3H -0.06 MRPC 4R DSIs SG C 13 39 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 .MRPC 4R DSIs SG C 13 40 DSI 3H +0.00 BOBBIN SG C INF 3H 40.00 MRPC 4R DSIs SG C 13 42 DSI 5H -0.04 BOBBIN SG C INF 5H -0.04 MRPC 4R DSIs SG C 13 43 DSI 3H +0.08 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C ?3 -47 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 13 49 DNG 2H +9.71 BOBBIN SG C DNG 6H +33.69 BOBBIN SG C 13 51 DSI 3H -0.02 _ BOBBIN SG C INF 3H -0.02 MRPC 4R DSIs. SG C 13 56 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 13 61 DNG SC +36.02 BOBBIN SG C 13 70 DSI 4H -0.10 BOBBIN SG C INF 4H +0.00 MRPC'4R DSIs SG C 13 71 DSI 4H -0.08 BOBBIN SG C INF 4H -0.08 MRPC 4R DSIs SG C 13 75 DNG 2C +23.20 BOBBIN SG C 13 78 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 13 83 DNG 7C +37.81 BOBBIN SG C DNG 7C +37.10 BOBBIN SG C 14 7 DNG 6C +37.77 BOBBIN SG C 14 17 DSI 4H +0.09 BOBBIN

1 .BWNS TUBAN II (Version 1.0) 10/26/1993 09:38:37 Beaver Valley Unit 2 SG C

                        • =***

4R 9/93 i \\ Page 7 of 18 STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C INF 4H +0.09 MRPC 4R DSIs SG C 14 32 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 14 37 DSI 2H +0.00 BOBBIN. SG C INF 2H +0.00 MRPC 4R DSIs SG C 14 38 DSI 2H -0.04 BOBBIN o SG C INF 2H -0.04 MRPC 4R DSIs SG C 14 39 DSI 3H +0.04 BOBBIN SG C INF 3H +0.04 MRPC 4R DSIs SG C 14 48 DNG 2H +9.82 BOBBIN SG C DNG 3C +13.40 BOBBIN SG C DNG 6C +46.52 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 14 50 DSI 2H -0.15 BOBBIN SG C DSI SH +0.00 BOBBIN SG C INF 2H -0.15 MRPC 4R DSIs SG C INF SH +0.00 HRPC 4R DSIs SG C 14 56 DSI 3H +0.02 BOBBIN SG C INF 3H +0.02 MRPC 4R DSIs SG C 14 59 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 14 64 DSI 3H +0.02 BOBBIN i SG C INF 3H +0.02 MRPC 4R DSIs SG C 14 67 DSI 3H -0.08 BOBBIN SG C INF 3H .-0.08 MRPC 4R DSIs SG C 14 68 DSI 5H -0.15 BOBBIN SG C INF 5H -0.15 MRPC 4R DSIs l SG C 14 71 DNG 2C +9.46 BOBBIN SG C 14 82 DSI 3H +0.06 BOBBIN SG C INF 3H +0.06-MRPC 4R DSIs SG C 15 5 DNG 7H +36.12' BOBBIN SG C DNG 7H +35.44 BOBBIN SG C 15 14 DSI 3H +0.12 EOBBIN SG C INF 3H +0.12 MRPC 4R DSIs SG C 15 35 INF 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 15 41 DSI 3H -0.04 BOBBIN SG C INF 3H -0.04 MRPC 4R DSIs SG C 15 42 DGI 3H -0.02 BOBBIN SG C INF 3H -0.02 MRPC 4R DSIs SG C 15 45 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 15 50 DSI 3H +0.06 BOBBIN SG C INF 3H +0.06 MRPC 4R DSIs SG C 15 55 DSI SH +0.00 BOBBIN SG C INF 5H +0.00 MRPC 4R DSIs l SG C 15 58 NQI TSC +0.59 BOBBIN SG C NQI TSC +0.45 MRPC Special In SG C 15 61 DSI 3H +0.00 BOBBIN SG r INF 3H +0.00 MRPC 4R DSIs SG C 15 65 DNG 6H +30.39 BOBBIN SG C DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG'C 15 71 DSI 4H +0.00 BOBBIN SG C INF 4H- +0.00 MRPC'4R DSIs SG C 15 72 DSI 2H -0.08 BOBBIN SG C INF 2H -0.08 MRPC 4R DSIs SG C 15 74 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 15 80 DSI 3H +0.03 BOBBIN SG C INF 3H +0.03 MRPC 4R DSIs SG C 16 15 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 16 19 INF 4H +0.00 MRPC'4R DSIs SG C 16 22 DSI 3H +0.02 BOBBIN A

4 ( s Beaver Val _ 10/26/1993 09:38:37 j (Version 1.0) ley Unit 2 ^BWNS TUBAN II SG C 4R 9/93 q Page 8 of 18 STEAM GENERATOR C (2RCS-SG21C) t 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE-SG C INF 3H +0.00 MRPC 4R DSIs SG C 16 24 DSI 3H -0.08 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs i SG C 16 26 ADR 3C +46.58 BOBBIN SG C DSI 3H -0.04' BOBBIN SG C INF 3H -0.04 MRPC 4R DSIs SG C VOL 3C +47.45 MRPC Special In SG C 16 28 INF 4H +0.00 MRPC 4R DSIs - i SG C 16 29 DSI 3H +0.06 BOBBIN f SG C INF 3H +0.06 MRPC 4R DSIs l SG C 16 31 DSI 4H -0.04 BOBBIN f SG C INF 4H -0.04 MRPC 4R DSIs SG C 16 45 PVN 6H +2.27 BOBBIN SG C 16 50 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs } SG C 16 51 DSI 3H +0.00 BOBBIN SG C INF. 3H +0.00 MRPC 4R DSIs SG C 16 52 DSI 2H +0.04 BOBBIN SG C INF 2H +0.04 MRPC 4R DSIs SG C 16 53 DSI SH -0.11 BOBBIN SG C INF SH -0.11 MRPC 4R DSIs SG C 16 54 DSI 7H -0.04 BOBBIN SG C INF 7H -0.04 MRPC 4R DSIs SG C 16 57 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 16 59 DSI 3H +0.02 ~ BOBBIN SG C INF 3H +0.02 MRPC 4R DSIs SG C 16 61 DSI 3H -0.06 BOBBIN SG C INF 3H -0.06 MRPC 4R DSIs .SG C 16 62 DSI 3H +0.00: BOBBIN SG C ITF 3H +0.00 MRPC 4R DSIs SG C 16 63 DSI 2H -0.06 BOBBIN: SG C DSI 3H -0.02 BOBBIN SG C INF 2H -0.06 MRPC 4R DSIs 3 SG C INF 3H +0.00 MRPC 4R DSIs SG C 16 73 DSI 2H -0.02 BOBBIN I SG C INF 2H -0.02 MRPC 4R DSIs i SG C 16 74 DSI 3H +0.00 BOBBIN SG C VOL 3H 40.00 MRPC 4R DSIs l SG C 16 91 ADR SH -1.18 BOBBIN 1 SG C VOL SH -0.66 MRPC Special In SG C 17 9 DSI 2H +0.03 BOBBIN-t SG C INF 2H +0.03 MRPC 4R DSIs SG C 17 30 DSI 5H +0.00 BOBBIN SG C INF 5H +0.00 MRPC 4R DSIs SG C 17 33 DSI 2H -0.06 BOBBIN T SG C INF 2H -0.06 MRPC 4R DSIs SG C 17 47 DNG 2C +4.53 BOBBIN f SG C DNG 6C +37.99 BOBBIN l SG C 17 49 DSI 3H +0.04 BOBBIN SG C INF 3H +0.04 MRPC 4R DSIs SG C. 17 50 DSI 4H -0.04-BOBBIN-SG C INF 4H -0.04 MRPC 4R DSIs SG C 17 54 DSI 3H. +0.02 BOBBIN SG C INF-3H +0.02 MRPC 4R DSIs SG C 17 61 DSI 3H +0.00 BOBBIN SG C INF-3H +0.00 MRPC 4R DSIs SG C 17 66 DSI 2H -0.06 ~ BOBBIN i SG C INF 2H -0.06 MRPC 4R DSIs SG C 17 70 DSI SH -0.04 BOBBIN SG C INF 5H -0.04 MRPC 4R DSIs SG C 17 74 DSI 4H -0.08 BOBBIN SG C INF 4H -0.0B MRPC 4R DSIs SG C 17 75 DSI 2H -0.06 BOBBIN-SG C INF 2H -0.06 MRPC 4R DSIs 't

_i l ene**ee***e** ee-BWNS'TUBAN II (Version 1.0)- 10/26/1993 09:38:37-Beaver Valley Unit 2 .l

  • e**************

SG C 4R 9/93 r 3 i i Page 9 of-18

i STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C 18 19 DSI 4H

+0.03 BOBBIN ) SG C INF 4H +0.03 MRPC 4R DSIs SG C 18 27 ODI 12 3H +13.82 BOBBIN SG C VOL 3H +14.13 MRPC Special In SG C 18 40 DSI 7H- -0.06 BOBBIN SG C INF 7H -0.06 MRPC 4R DSIs SG C 18 46 DSI 5H -0.04 BOBBIN SG C INF 5H -0.04 MRPC 4R DSIs SG C 18 48 DNG 6C +35.51 BOBBIN t SG C 18 52 DSI 4H -0.09 BOBBIN SG C INF 4H -0.09 MRPC 4R DSIs SG C 18 56 DSI 3H +0.00 BOBBIN-I SG C DSI 53 -0.13 BOBBIN SG C INF 3H + 0. 00 = MRPC 4R DSIs SG C INF 5H -0.13 MRPC 4R DSIs .2 SG C 18 62 DSI 3H -0.09 BOBBIN t! SG C INF 3H -0.09 MRPC 4R DSIs SG C 18 69 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 18 71 USI 3H -0.09 BOBBIN SG C INF 3H -0.09-MRPC 4R DSIs SG C 18 75 DSI 3H +0.02

BOBBIN INF 3H

+0.02 MRPC 4R DSIs SG C 34 DNG 4C +21.82 BOBBIN SG C 19 SG C 39 37 ADR 6H +34.42 . BOBBIN SG C INF 6H +34.42 'MRPC Special In SG C 19 38 DNG 6C +36.62 BOBBIN-SG C DNG 6H +12.60 BOBBIN-SG C DSI 3H +0.00 BOBBIN SG C INF 3H +.0.00 MRPC 4R DSIs' SG C 19 39 DNG 6C +35.68 BOBBIN-I SG C 19 44 D3I. 3H +0.02 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs l SG C 19 45 DSI 3H -0.08 BOBBIN SG C INF 3H -0.08 MRPC 4R DSIs-i SG C 19 49 DSI 2H -0.06 BOBBIN SG C DSI '3H +0.00 BOBBIN i SG C INF 2H -0.06 MRPC 4R DSIs INF 3H +0.00 'MRPC 4R DSIs SG C 58 DSI 5H +0.00 -BOBBIN SG C 19 SG C INF 5H +0.00 MRPC 4R DSIs SG C 19 60 DSI 2H -0.04 BOBBIN-SG C INF 2H -0.04 MRPC 4R DSIs SG C 19 74 DSI 3H -0.02 BOBBIN SG C INF 3H -0.02 MRPC 4R DSIs SG C 20 10 INF 4H +0.00 MRPC 4R DSIs SG C 20 34 DSI 2H -0.04 BOBBIN SG C INF 2H -0.04 MRPC 4R DSIs SG C 20 37 DSI 3H +0.02 BOBBIN SG C INF 3H +0.02 MRPC 4R-DSIs ~; SG C 20 42 DSI 3H -0.04 BOBBIN 1 SG C INF 3H -0.04 MRPC 4R DSIs J SG C 20 46 DSI 2H -0.08 BOBBIN SG C INF-2H -0.08 MRPC 4R DSIs SG C 20 50 DSI SH -0.04 BOBBIN ] SG C INF 5H -0.04 MRPC-4R DSIs SG C 20 52 DSI 5H -0.02 BOBBIN j SG C INF SH -0.02 MRPC 4R DSIs 1 SG C 20 54 DSI 3H -0.08 BOBBIN SG C DSI 4H -0.06 BOBBIN j SG C INF 3H -0.08 MRPC 4R DSIs SG C INF 4H -0.06 MRPC 4R DSIs SG C 20 62 INF 2H +0.00 MRPC 4R DSIs SG C 20 75 DSI 2H -0.04 BOBBIN' i SG C INF 2H -0.04 MRPC 4R DSIs j 1 i

BWNS TUBAN II (Version 1.0) 10/26/1993 09:38:37 Beaver Valley Unit 2 SG C + [ 4R 9/93 Page 10 of 18 STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS { GEN ROW COL IND 17W LOCATION TEST TYPE t SG C 20 76 DSI 3H +0.06 BOBBIN k SG C INF 3H +0.06 MRPC 4R DSIs r SG C 20 83 DSI 2H +0.06 BOBBIN. SG C INF 2H +0.06 MRPC 4R DSIs SG C 21 11 DNG 7C +16.94 BOBBIN L SG C 21 38 DSI 3H -0.17 BOBBIN i SG C INF 3H -0.17 MRPC 4R DSIs ~ SG C 21 41 DSI 2H -0.04 BOBBIN SG C INF 2H -0.04 MRPC 4R DSIs ,+ SG C 21 58 DSI 3H -0.06 BOBBIN SG C INF 3H -0.06 MRPC 4R DSIs SG C 21 60 DSI 2H +0.04 BOBBIN SG C DSI 3H +0.04 BOBBIN SG C INF 2H +0.04 .MRPC 4R DSIs [ SG C INF 3H +0.04 MRPC 4R DSIs SG C 21 63 DSI 2H -0.09 BOBBIN SG C DSI 3H +0.02 BOBBIN SG C DSI SH +0.04 BOBBIN SG C INF 2H -0.09 MRPC 4R DSIs i SG C INF 3H +0.02 MRPC 4R DSIs SG C INF 5H +0.04 MRPC 4R DSIs SG C 21 64 DSI 3H -0.02 BOBBIN -I SG C INF 3H -0.02 MRPC 4R DSIs SG C 21 65 DSI 3H +0.00 BOBBIN SG C DSI 5H +0.02 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs } SG-C INF 5H +0.00 MRPC 4R DSIs SG C 21 73 ODI 7 AV4 +5.86 BOBBIN SG C VOL AV4 +5.86 MRPC Special In i SG C 21 76 DSI 2H - +0.06 BOBBIN [ SG C INF 2H +0.06 MRPC 4R DSIs SG C 21 81 DSI 2H +0.03 BOBBIN SG C INF 2H +0.03 MRPC 4R ESIs SG C 21 87 ODI 13 4C +7.21 BOBBIN SG C NQI 4C +7.96 MRPC Special In SG C 21 88 ADR 3C +13.83 BOBBIN SG C ODI 31 3H +8,54 BOBBIN SG C INF 3C +13.83 HRPC Spccial In SG C VOL 3H +8.61 MRPC Special In SG C 22 12 DSI 2H +0.00 BOBBIN ' SG C INF 2H +0.00 MRPC.4R DSIs SG C 22 25 DNT TEH +6.14 BOBBIN SG C 22 36 DSI 3H -0.11 BOBBIN SG C INF 3H -0.11 MRPC 4R DSIs SG C .2 38 DSI 3H +0.12 BOBBIN SG C INF 3H +0.12 MRPC 4R DSIs SG C 22 43 DSI 3H 40.06 BOBBIN SG C INF 3H +0.06 MRPC 4R DSIs l SG C 22 53 ODI 15 TSC +1.80 BOBBIN ~ 2 SG C VOL TSC +1.21 MRPC Special In SG C 22 54 DSI 3H +0.06 BOBBIN SG C INF 3H +0.06 MRPC 4R DSIs SG C 22 63 ODI 17 7C +39.25 BOBBIN SG C VOL 7C +39.03 MRPC Special In SG C 22 64 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 .MRPC 4R DSIs SG C 22 65 DNG AV2 +10.31 BOBBIN SG C SAI AV2 +11.06 MRPC Special In SG C 22 67 DSI 2H +0.03 BOBBIN SG C INF 2H +0.03 MRPC 4R DSIs SG C 22 68 DSI 2H +0.03 BOBBIN SG C INF 2H +0.03 MRPC 4R DSIs SG C 22 76 JSI SH +0.09 BOBBIN SG C INF 5H +0.09 MRPC 4R DSIs SG C 22 79 DNG 3H +24.17 BOBBIN

BWNS TUBAN II (Version 1.0) 10/26/1993 09:38:37 Beaver Valley Unit 2 L**************** SG C l.**************** 4R 9/93 Page 11 of 18-STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C 22 81 NQI SC +21.71 BOBBIN SG C NQI SC +21.90 MRPC Special In SG C 23 24 INF 3H +0.00 MRPC 4R DSIs SG C 23 31 DSI 2H -0.04 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 23 35 INF 4H +0.00 BOBBIN SG C INF 4H +0.00 MRPC 4R DSIs SG C 23 40 INF 4H +0.00 BOBBIN SG C INF 4H +0.00 MRPC 4R DSIs SG C 23 42 DSI 2H -0.02 BOBBIN SG C DSI 3H -0.08 BOBBIN SG C INF 2H -0.02 MRPC 4R DSIs SG C INF 3H -0.08 MRPC 4R DSIs SG C 23 54 INF 2H +0.00 MRPC 4R DSIs SG C 23 55 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 23 56 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C VOL 2H +1.35 MRPC 4R DSIs SG C 23 58 DNG 6H +24.73 BOBBIN SG C DSI 2H +0.00 BOBBIN SG C DSI 3H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs SG C 24 36 DNG 5H +29.14 BOBBIN SG C 24 38 PVN TSH -0.03 MRPC TSH SG C 24 46 DSI 2H -0.06 BOBBIN SG C INF 2H -0.06 MRPC 4R DSIs SG C 24 47 DSI 3H -0.08 BOBBIN SG C INF 3H -0.08 MRPC 4R DSIs-SG C 24 48 DSI 3H +0.04 BOBBIN SG C DNG TSH +14.29 BOBBIN SG C INF 3H +0.04 MRPC 4R DSIs SG C 24 51 DSI 2H -0.04 BOBBIN t SG C DSI 4H -0.06 BOBBIN SG C INF 2H -0.04 MRPC 4R DSIs SG C INF 4H -0.06 MRPC 4R DSIs SG C 24 55 DSI 3H +0.00 ~ BOBBIN SG C DSI SH +0.02 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C INF 5H +0.02 MRPC 4R DSIs SG C 24 56 DSI 2H -0.06 BOBBIN SG C DSI 3H +0.06 BOBBIN SG C DNG TSH +13.01 BOBBIN SG C INF 2H -0.06 MRPC 4R DSIs SG C INF 3H +0.06 MRPC 4R DSIs SG C 24 57 DNG 6H +30.67 BOBBIN SG C 24 61 NQI 4H +15.64 BOBBIN SG C. VOL 4H +16.03 MRPC Special In SG C 24 68 DSI 3H +0.03 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 24 69 DSI 2H -0.03 BOBBIN SG C INF 2H -0.03' MRPC 4R DSIs SG C 24 71 DNG 2H +16.70 BOBBIN SG C DNG 1H +3.91 BOBBIN SG C DNG IH +10.23 BOBBIN SG C DNG TSH +17.99 BOBBIN SG C DNG TSH +4.89 BOBBIN SG C DNG TSH +11.48 BOBBIN SG C 25 24 ODI 4 2C +11.86 BOBBIN SG C NQI IC -1.03 to

  • BOBBIN SG C INF IC

+6.43 MRPC Special In SG C INF 2C +11.86 MRPC Special In SG-C 25 25 INF -3H +0.06 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs

BWNS TUBAN II (Version 1.0) 10/26/1993 09:38:37

                                • T I'

Beaver Valley. Unit 2 SG C 4R 9/93 .i Page'12 of 18 STEAM CENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C - 2 5 30 PVN TSH -1.02 MRPC TSH SC C PVN TSH -1.28 MRPC TSH 'f SG C 25 31 DSI 2H +0.06 BOBBIN-SG C INF 2H +0.06 MRPC 4R DSIs SG C 25 34 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 25 35 INF 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs' SG C 25 36 DSI 2H -0.08. BOBBIN l SG C INF 2H -0. 0 8 - MRPC 4R DSIs SG C 25 38 DNG 2H +41.62 BOBBIN SG C 25 47 DSI 2H -0.06 BOBBIN SG C INF 3H +0.00 BOBBIN SG C INF 2H -0.06 MRPC 4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs 1; SG C 25 48 DSI 4H -0.08 BOBBIN SG C INF 4H -0.08 MRPC 4R DSIs SG C 25 51 DSI 2H -0.04 BOBBIN i SG C DSI 3H +0.02 BOBBIN SG C INF 2H -0.04 MRPC 4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs SG C 25 54 ADR 6C +33.31 BOBBIN SG C DSI 2H +0.08 BOBBII* SG C INF 2H +0.08 MRPC 4R DSIs i SG C VOL 6C +32.76 MRPC Special In SG C 25 56 DSI 3H -0.04 BOBBIN I SG C INF 3H -0.04 MRPC 4R DSIs SG C 25 57 DSI 2H -0.04 BOBBIN SG C INF 2H -0.04' PRPC 4R DSIs SG C 25 60 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R'DSIs SG C 25 69 DSI 2H +0.06 BOBBIN-l SG C INF 2H +0.06 MRPC 4R DSIs SG C 25 73 DSI 3H +0.09 BOBBIN SG C INF 3H +0.09 MRPC 4R DSIs SG C 25 81 DNT TEH +7.50 BOBBIN SG C 26 11 PVN TSC +10.17 BOBBIN i SG C 26 14 DSI SH +0.00 BOBBIN SG C INF 5H +0.00 MRPC 4R DSIs I SG C 26 16 DNG 4C +7.27 -BOBBIN .f SG C 26 21 DNG 7C +5.21 BOBBIN SG C 26 26 DTI TEC +16.11 BOBBIN' SG C INF TEC +16.11 MRPC Special In SG C 26 31 DSI 4H -0.04 BOBBIN SG C INF 4H -0.04 MRPC 4R DSIs SG C 26 37 DSI 2H -0.04 BOBBIN 4 SG C INF 2H -0.04 MRPC 4R DSIs SG C 26 39 DSI SH +0.00 BOBBIN SG C DSI 7H -0.11 BOBBIN SG C ODI 19 2H +35.35 BOBBIN-SG C INF 5H +0.00 MRPC 4R DSIs t SG C INF 7H -0.11 MRPC 4R DSIs l SG C VOL 2H +34.99 MRPC Special In SG C 26 41 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 26 42 DSI 2H -0.08 BOBBIN SG C INF 2H -0.08 MRPC 4R DSIs SG C 26 49 DSI 2H +0.00 DOBBIN SG C INF 2H +0.00 MRPC 4R DSIs i SG C 26 53 DSI 2H -0.12 BOBBIN l SG C DSI 3H +0.00 ROBBIN i SG C INF 2H -0.12 MRPC 4R DSIs 4 SG C INF 3H +0.00 MRPC 4R DSIs .) SG C 26 55 DSI 5H +0.00 BOBBIN j SG C INF 2H +0.00 MRPC'4R DSIs -I 1 l

EBWNS TUBAN II (Version 1.0) 10/26/1993 09:38:37 Beaver Valley Unit 2. SG C 4R 9/93 C Page 13 of 18 STEAM GENERATOR C (2RCS-SG21C) -l 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C INF SH +0.00 MRPC 4R DSIs SG C 26 59 DSI 3H -0.06 BOBBIN [ SG C INF 3H -0.06 MRPC 4R DSIs SG C 26 60 DSI 3H -0.06 BOBBIN ~ SG C INF 3H -0.06 MRPC 4R DSIs SG C 26 62 DNG 4C +40.86 BOBBIN SG C DNG SC +29.05 BOBBIN SG C 26 64 DSI 5H -0.08 BOBBIN SG C INF 5H -0.08 MRPC 4R DSIs SG C 27 16 PVN 2C -1.51 BOSBIN j SG C 27 19 DSI 3H +0.06 BOBBIN SG C INF 3H +0.06 MRPC 4R DSIs SG C 27 32 DSI -2H -0.08 BOBBIN SG C INF 2H -0.0B MRPC 4R DSIs SG C 27 36 DSI SH +0.00 BOBBIN f SG C INF 5H +0.00 MRPC 4R DSIs l SG C 27 39 INF 5H -0.06 MRPC 4R DSIs SG C 27 41 DSI 3H +0.00 BOBBIN j SG C DSI SH +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C INF 5H +0.00 MRPC 4R DSIs SG C 27 42 DSI 2H -0.06 BOBBIN SG C DSI .3H +0.00 BOBBIN. SG C INF 2H -0.06 MRPC 4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs SG C 27 45 DSI 2H -0.13-BOBBIN SG C INF. 2H -0.13 MRPC 4R DSIs SG C 27 46 INF 4H +0.00 MRPC 4R DSIs SG C 27 48 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs i SG C 27 51 DSI 3H -0.02 BOBBIN 'i SG C INF 3H +0.00 MRPC 4R DSIs SG C 27 53 DNG 1H +24.05 BOBBIN SG C 27 54 DNG 2H +38.13 BOBBIN SG C 27 56 DSI 3H +0.04 BOBBIN SG C VOL 3H -0.08 MRPC 4R DSIs SG C 27 58 DSI 5H +0.00 BOBBIN SG C INF 5H +0.00 MRPC 4R DSIs SG C 27 68 DNT TEH +10.44 BOBBIN SG C 28 10 DNT 3C -0.29 BOBBIN SG C DNT 4C -0.43 BOBBIN SG C 28 27 DSI 5H +0.03 BOBBIN SG C INF SH +0.03 MRPC 4R DSIs SG C 28 28 DSI 3H +0.06 BOBBIN SG C INF 3H +0.06 MRPC 4R DSIs i SG C 28 31 DSI 3H +0.02 BOBBIN SG C DSI 4H +0.00 EOBBIN SG C INF 3H +0.02 MRPC 4R DSIs SG C INF 4H +0.00 MRPC 4R DSIs SG C 28 33 DSI 2H -0.15 BOBBIN SG C INF 2H -0.15 MRPC 4R DSIs SG C 28 36 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 28 40 DSI 2H +0.00 BOBBIN SG C DSI 3H +0.00 BOBBIN SG C DSI 4H -0.06 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs j SG C INF .4H -0.06 MRPC 4R DSIs 1 SG C 28 41 DSI 2H +0.00 BOBBIN-SG C DSI 3H +0.04 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C INF 3H +0.04 MRPC 4R DSIs SG C 28 42 DSI 2H -0.04 BOBBIN SG C INF 2H -0.04 MRPC 4R DSIs

l BWNS TUBAN II (Version 1.0) 10/26/1993 09:38:37 Beaver Valley Unit 2 SG C 4R 9/93 j Page 14 of 18 STEAM GENERATOR C (2RCS-SG21C) 1 4R INDICATIONS l GEN ROW COL IND %TW LOCATION TEST TYPE-SG C 28 44 DSI 2H -0.06 BOBBIN SG C INF 2H -0.06 MRPC 4R DSIs SG C 28 45 ODI 9 3H +19.31 BOBBIN SG C VOL 3H +19.80 .MRPC Special In SG C 28 46 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 28 47 DSI 2H .-0.04 BOBBIN SG C DSI 3H +0.00 -BOBBIN SG C INF 2H -0.04 MRPC 4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs SG C 28 48 DSI 3H -0.15 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 28 50 DSI 3H -0.04 BOBBIN SG C DSI SH -0.04 BOBBIN SG C INF 3H +0.00' MRPC 4R DSIs SG C INF 5H +0.00 MRPC 4R DSIs SG C 28 53 DNG 8H +9.08 BOBBIN 1 SAI BH +9.09 MRPC Special In SG C. 28 54 DNG BH +8.95 BOBBIN SG C SG C SAI BH +9.47 MRPC Special In SG C 28 56 DNG BH +8.67 BOBBIN SG C SAI 8H +9.23 MRPC Special In SG C 28 57 DNG BH +8.66 BOBBIN SG C DNG BH +8.79 MRPC Special In SG C 28 68 DNT TEH +19.26 ' BOBBIN SG C 28 70 ADR 7C +39.09 BOBBIN SG C VOL 7C +38.18 MRPC Special In SG C 28 75 DNT TEH +7.35 BOBBIN SG C DNT TEH +18.40 BOBBIN SG C DNT TEH +15.44 BOBBIN SG C 29 24 DSI 5H +0.12 BOBBIN SG C INF 5H +0.12 MRPC 4R DSIs SG C 29 34 DSI 3H -0.08 BOBBIN SG C INF 3H -0.08 MRPC 4R DSIs SG C 29 36 DSI 3H +0.00 BOBBIN SG C INF 2H +0.00 DOBBIN SG C INF 2H +0.00 MRFC 4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs SG C INF 4H +0.00 MRPC 4R DSIs SG C 29 38 DSI SH +0.00 BOBBIN SG C INF 5H +0.00 MRPC 4R-DSIs SG C 29 47 DSI 2H -0.08 BOBBIN SG C INF 2H -0.08 MRPC 4R DSIs SG C 29 48 DSI 2H -0.06 BOBBIN SG C DSI 3H +0.00 . BOBBIN SG C INF 2H -0.06 MRPC 4R DSIs - SG C INF 3H +0.00 MRPC 4R DSIs SG C 29 50 DSI 2H +0.00 BOBBIN SG C DSI 5H +0.04 BOBBIN. SG C INF 2H +0.00 MRPC 4R DSIs SG C INF 5H +0.00 MRPC 4R DSIs + SG C 29 57 DSI 3H -0.04 BOBBIN SG C DSI SH +0.00 BOBBIN SG C INF 3H- -0.04. MRPC 4R DSIs s SG C INF 5H +0.00 MRPC 4R DSIs SG C 29 58 DSI 3H +0.00 BOBBIN SG C VOL 3H +0.26 MRPC 4R DSIs' SG C 29 60 DSI 3H +0.00 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 29 61 DSI 3H' +0.00 BOBBIN t SG C INF 3H +0.00 MRPC 4R DSIs SG C 29 83 DNT TEH +14.46 BOBBIN SG C 30 30 DSI 4H -0.04 BOBBIN SG C INF 4H -0.04 MRPC 4R DSIs SG C 30 31 DSI 4H -0.04 BOBBIN b

t BWNS TUBAN II (Version 1.0). 10/26/1993 09:38:37 Beaver Valley Unit 2 SG C 4g 9/93 Page 15 of 18 i STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C INF 4H -0.04 MRPC 4R DSIs SG C 30 36 DSI 3H -0.06 BOBBIN SG'c INF 3H -0.06 MRPC 4R DSIs .i SG C 30 39 DSI 3H -0.13 BOBBIN _ SG C INF 3H -0.13 MRPC 4R DSIs SG C 30 41 DSI 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 30 42 DSI 2H -0.02 BOBBIN SG C INF 2H -0.02 MRPC 4R DSIs SG C 30 44 DSI 2H -0.04 BOBBIN SG C INF 2H -0.04 MRPC 4R DSIs SG C 30 48 DSI 2H -0.08. BOBBIN SG C DSI 3H +0.06 BOBBIN + SG C INF 2H -0.06 MRPC 4R DSIs SG C INF 3H -0.13 MRPC 4R DSIs SG C 30 49 DSI 2H +0.00 BOBBIN i SG C INF 2H +0.00 MRPC 4R DSIs SG C 30 50 DSI 2H +0.02 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 30 57 DSI 3H +0.02 BOBBIN SG C INF 3H +0.05 MRPC 4R DSIs SG C 30 60 DSI 2H -0.10 BOBBIN SG C INF 2H -0.10 MRPC 4R DSIs SG C 30 61 DSI 2H -0.10 BOBBIN SG C DSI 4H -0.08 BOBBIN SG C INF 2H -0.10 MRPC 4R DSIs. SG C INF 4H -0.08 MRPC du DSIs SG C 30 62 DSI 3H +0.10 BOBB".9 SG C INF. 3H +0.10 MRPC iR 23Is SG C 30 64 DSI 2H -0.08 BOBB1N SG C INF 2H -0.08 MRPC 4n DSIs SG C 30 65 PVN TSH -1.07 MRPC TSH SG C 31' 25 DNG TSC +2.30 BOBBIN SG C 31 26 INF 2H +0.00 MRPC 4R DSIs SG C 31 35 INF 2H +0.00 MRPC 4R DSIs SG C 31 42 ADR 2H +23.30 BOBBIN i SG C VOL 2H- +24.00 MRPC Special In SG C 31 46 DNG 4C +43.15 BOBBIN SG C DNG 4C +41.21 BOBBIN SG C ODI 34 TSH +6.22 BOBBIN SG C ADR 3C +5.00 to +* BOBBIN SG C VOL TSH +5.38 MRPC Special In .i SG C INF 3C +5.00 to +* MRPC Special In SG C 31 47 DSI 2H +0.06 BOBBIN SG C INF 2H +0.06 MRPC 4R DSIs SG C 31 54 USI 3H +0.12 BOBBIN SG C INF 3H +0.12 MRPC 4R DSIs i SG C 31 55 DSI 3H +0.12 BOBBIN SG C INF 3H +0.12 MRPC 4R DSIs -l SG C 31 56 DSI 2H +0.15 BOBBIN SG C INF 2H +0.15 MRPC 4R DSIs SG C 32 28 INF 2H +0.00 MRPC 4R DSIs SG C 32 34 INF 2H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs i SG C 32 38 INF 2H +0.00 MRPC 4R DSIs SG C 32 41 INF 3H +0.00 MPPC 4R DSIs SG C 32 42 DSI 4H +0.12 BOBBIN SG C NQI 2C +11.15 BOBBIN SG C INF 4H +0.12 MRPC 4R DSIs + SG C INF 2C +11.15 MRPC Special In SG C 32 52 DSI 2H +0.06 BOBBIN l SG C DSI 4H +0.00 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C INF 4H +0.00 MRPC 4R DSIs i SG C 32 55 DSI 3H +0.00 BOBBIN -)

BWNS TUBAN II (Version 1.0). 10/26/1993 09:38:37 Beaver Valley Unit 2 SG C 4R 9/93 i j Page 16 of 18. STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE-SG C INF 3H 40.00 MRPC 4R DSIs SG C 32 60 DSI 4H +0.00 ' BOBBIN SG C INF 4H +0.00 MRPC-4R DSIs SG C 32 65 ETL TSH -0.86 BOBBIN .i SG C INF TSH -0.86 MRPC-Special In SG C 33 28 INF 5H +0.09 BOBBIN SG C INF 5H +0.00 MRPC 4R DSIs SG C 33 42 DSI 3H +0.00 BOBBIN, 6 SG C INF 3H +0.00 MRPC 4R DSIs SG C 33 44 DSI 2H +0.06 BOBBIN SG C INF 2 11 +0.06 MRPC 4R DSIs SG C 33 60 DSI 3H +0.03 BOBBIN SG C INF 3H +0.03 MRPC 4R DSIs SG C 33 64 DSI 2H +0.03 BOBBIN i SG C INF 2H +0.03 MRPC 4R DSIs SG C 34 26 DNG-OTHER BOBBIN SG C 34 31 DNG IC +13.48 BOBBIN SG C 34 35 DSI 3H +0.09 BOBBIN SG C INF -3H 40.09 MRPC 4R DSIs SG C 34 43 PVN TSH -0.67 MRPC TSH SG C PVN TSH -1.11 MRPC TSH SG C 34 50 ADR AVI +21.90 BOBBIN SG C INF AVI +21.90 MRPC Special In SG C 34 63 DNG 5H +29.71 BOBBIN I SG C 34 72 PVN TSH -3.54 MRPC TSH SG C PVN TSH +1.28 MRPC TSH l SG C 35 28 DNG AV2 -1.64 BOBBIN SG C DNG AV2 -1.59 BOBBIN SG C SAI AV2 -1.86 MRPC Special In SG C 35 34 INF 3H +0.06 BOBBIN SG C INF 3H +0.00 MRPC-4R DSIs SG C 35 48 DSI 2H +0.13 BOBBIN SG C DSI 3H +0.00 BOBBIN SG C DSI 4H +0.00 BOBBIN SG C INF 2H 40.13 MRPC 4R DSIs SG C INF 3H +0.00 MRPC 4R DSIs SG C INF 4H +0.00 MRPC 4R DSIs SG C 35 56 DSI 3H +0.08 BOBBIN SG C INF 3H +0.08 MRPC 4R DSIs SG C 35 63 ODI 15 AV3 +0.00 BOBBIN SG C SAI AV3 40.00 MRPC Special In 1 SG C 35 74 DRI TEH +17.74 BOBBIN SG C INF TEH +17.74 MRPC Special In SG C 35 77 DNG 7H +20.04 BOBBIN SG C 36 22 NQI 7C +24.88 BOBBIN i SG C ETL TSC +2.08 BOBBIN SG C PVN 7C +24.78 .MRPC Special In l SG C INF' TSC +2.08 MRPC Special In SG C 36 26 DSI 3H +0.09 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 36 35 DSI 3H +0.05 BOBBIN SG C INF ,3H +0.05 MRPC 4R DSIs I SG C 36 36 DNG 6C +35.81 BOBBIN SG.C 36 61 DNG TSC +12.64 BOBBIN SG C 36 63 DNG 2H +22.51 BOBBIN ti SG C 36 77 DNG 4C +32.08 BOBBIN SG C DNG 7C +1.08 BOBBIN SG C 37-20 DNG 1H +7.06 BOBBIN SG C 37 23 DNG OTHER BOBBIN SG C 37 35 DNG 7C +25.64 BOBBIN SG C 37 38 INF 3H +0.00 MRPC 4R DSIs SG C 37 43 HQI 2H +13.48 BOBBIN SG C INF 2H +13.48 MRPC Special In SG C 37 46 ODI 14 6C +44.88 BOBBIN SG C VOL 6C +44.63 MRPC Special In 'I I

BWNS'TUBAN II (Version 1.0) 10/26/1993 09:38:37 Beaver Valley Unit 2 +.e************* SG C 4R 9/93 L Page 17 of 18 STEAM CENERATOR C (2RCS-SG22C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C 37 58 DSI 6H +0.12 BOBBIN r SG C INF 6H +0.12 MRPC 4R DSIs SG C 37 60 DSI 4H +0.00 BOBBIN SG C INF 4H +0.00 MRPC 4R DSIs SG C 37 67 DSI 4H +0.00 BOBBIN SG C ODI 13 AV3 +0.00 BOBBIN SG C INF 4H +0.00 MRPC 4R DSIs SG C VOL AV3 +0.01 MRPC Special In SG C 37 71 PVN TSH -1.36 MRPC TSH SG C 38 27 DNG OTHER BOBBIN SG C 38 28 INF 3H +0.03 BOBBIN SG C INF 3H +0.00 MRPC 4R DSIs SG C 38 41 ODI 31 6C +22.32 BOBBIN SG C VOL 6C +22.11 MRPC Special In r SG C 38 50 ODI 20 2C +45.76 BOBBIN SG C VOL 2C +45.71 MRPC Special In SG C 38 52 DSI 2H +0.05 BOBBIN SG C INF 2H +0.00 MRPC 4R DSIs SG C 38 57 DNG TSC +11.11 BOBBIN SG C 38 61 DSI 4H +0.05 BOBBIN SG C INF 4H +0.05 MRPC 4R DSIs SG C 38 64 DSI 6H +0.02 BOBBIN } SG C INF 6H +0.02 MRPC 4R DSIs SG C 39 25 DNG 3H +25.68 BOBBIN I SG C 39 29 INF 4H +0.06 BOBBIN SG C INF 4H +0.00 MRPC 4R DSIs SG C 39 35 DNG 2H +14.09 BOBBIN SG C 39 42 DNG 4C +26.79 BOBBIN SG C 39 45 ODI 16 AV4 +5.99 BOBBIN SG C INF AV4 +5.99 MRPC Special In SG C 39 46 DSI 4H +0.03 BOBBIN SG C INF 4H +0.03 MRPC 4R DSIs SG C 39 47 DSI SH +0.02 BOBBIN' SG C INF 5H +0.02 MRPC 4R-DSIs SG C 39 51 DSI 4H +0.10 BOBBIN SG C INF 4H +0.10 -MRPC 4R DSIs l SG C 39 70 DNG TSH +16.66 BOBBIN SG C DNG TSH +17.21 BOBBIN SG C 40 36 DNG 2C +4.51 BOBBIN SG C DNG 2C +5.19 BOBBIN SG C DNG 6C +37.35 BOBBIN SG C 40 49 DSI 4H +0.10 BoaBIN SG C INF 4H +0.10 MRFC 4R DSIs SG C 40 53 DSI 4H +0.05 BOBBIN SG C INF 4H +0.05 MRPC 4R DSIs SG C 40 57 DSI 3H +0.05 BOBBIN [ SG C INF 3H +0.05 MRPC 4R DSIs SG C 40 64 ADR AVI +30.16 BOBBIN SG C VOL AVI +31.88 MRPC Special In SG C 41 35 NQI TSC +12.29 BOBBIN SG C VOL IC -7.67 MRPC Special In SG C 41 36 DNG 3H +26.14 BOBBIN SG C 41 48 ODI 21 TSC +11.00 BOBBIN SG C VOL TSC +11.03 MRPC Spec 1.4 In SG C 41 51 DSI 5H- +0.15 BOBBIN SG C INF SH +0.15 MRPC 4R DSIs SG C 41 60 DSI 4H +0.10 BOBBIN SG C INF 4H +0.10 MRPC 4R DSIs SG C 41 64 NQI IC +11.47 BOBBIN SG C INF IC +11.47 MRPC Special In SG C 42 39 DNG AV2 +3.19 BOBBIN SG C OBS AV3 -21.69 BOBDIN SG C 42 48 ADR 2C +43.13 BOBBIN SG C VOL 2C +42.61 MRPC Special In SG C 43 36 DNG 3H +2.74 BOBBIN I I

BWNS TUBAN II (Version 1.0) 10/26/1993 09:38:37 Beaver Valley Unit 2 SG C 4R 9/93 .e.............. Page 18 of 18 STEAM GENERATOR C (2RCS-SG21C) 4R INDICATIONS GEN ROW COL IND %TW LOCATION TEST TYPE SG C 43 39 NQI AV2 +5.05 BOBBIN SG C SAI AV2 +5.61 MRPC Special In SG C 43 40 DNG AV2 +5.70 BOBBIN SG C SAI AV2 +6.15 MRPC Special In SG C 43 42 DNG AV4 +27.94 BOBBIN SG C INF AV4 +27.94 MRPC Special In SG C 44 40 DNG AV2 +5.64 BOBBIN SG C SAI AV2 +6.10 MRPC Special In SG C 45 40 DNG AV2 +6.18 BOBBIN SG C SAI AV2 +6.44 MRPC Special In SC C 45 47 ADR AV2 +14.18 BOBBIN SG C VOL AV2 +14.88 MRPC Special In SG C 45 58 DNG IH +23.02 BOBBIN SG C DNG 2H +15.68 BOBBIN SG C DNT 2C +0.00 BOBBIN SG C 46 42 ADR 8H +10.98 BOBBIN SG C INF BH +10.98 MRPC Special In SG C 46 48 ADR AV2 +30.39 BOBBIN SG C INF AV2 +30.39 MRPC Special In Total Indications Found = 1124 Total Tubes Found = 530 ) 1

.v. ~ e*************** BWNS TUBAN II (Version 1.0) 10/22/1993 09:28:14 Beaver Valley Unit 2 SG C 1 l 4R 9/93 i 1 Page'1 of 1 ) STEAM GENERATOR C (2RCS-SG21C) 4R PLUGGED TUBES GEN ROW COL IND %TW LOCATION TEST TYPE SG C 1 38 DSI 2H +0.10 BOBBIN SG C VOL 2H -0.06 MRPC 4R DSIs l SG C 5 1 ETL TSC +1.42 BOBBIN SG C 8 75'ODI 8 4C +43.41 BOBBIN SG C NQI 4C +45.67 MRPC Special In SG C VOL 4C +43.01 MRPC Special In 3 SG C 11 40 DSI 3H -0.06 BOBBIN SG C VOL 3H -0.06 MRPC 4R DSIs SG C 12 4 NQI TSH +5.55 BOBBIN SG C DEG TSH +5.01 MRPC.Special In SG C 12 44 DSI 3H +0.00 BOBBIN SG C VOL 3H +0.51 MRPC 4R DSIs SG C 15 58 NQI TSC +0.59 BOBBIN SG C NQI TSC +0.45 MRPC Special In SG C 16 74 DSI 3H +0.00 BOBBIN SG C VOL 3H +0.00 MRPC 4R DSIs SG C 21 87 ODI 13 4C +7.21 BOBBIN 1 SG C NQI 4C +7.96 MRPC Special In i SG C 22 65 DNG AV2 +10.31 BOBBIN SG C SAI AV2 +11.06 MRPC Special In SG C 22 81 NQI SC +21.71 BOBBIN SG C NQI SC +21.90 MRPC Special In SG C 23 56 DSI 2H +0.00 BOBBIN SG C VOL 2H +1.35 MRPC 4R DSIs SG C 27 56 DSI 3H +0.04 BOBBIN SG C VOL 3H -0.08 MRPC 4R DSIs l SG C 28 53 DNG BH +9.08 BOBBIN SG C SAI BH +9.09 MRPC Special In SG C 28 54 DNG BH +8.95 BOBBIN i SG C SAI 8H +9.47 MRPC Special In SG C 28 56 DNG BH +8.67 BOBBIN SG C SAI 8H +9.23 MRPC Special In SG C 28 57 DNG BH +8.66 BOBBIN SG C DNG 8H +8.79 MRPC Special In SG C 29 58 DSI 3H +0.00 BOBBIN SG C VOL 3H +0.16 MRPC 4R DSIs SG C 31 46 DNG 4C +43.15 BOBBIN + SG C DNG 4C +41.21 BOBBIN SG C ODI 34 TSH +6.22 BOBBIN SG C ADR 3C +5.00 to +* BOBBIN SG C VOL TSH +5.38 MRPC Special In SG C 35 28 DNG AV2 -1.64 BOBBIN t SG C DNG AV2 -1.59 BOBBIN i SG C SAI AV2 -1.86 MRPC Special In SG C 35 63 ODI 15 AV3 +0.00 BOBBIN SG C SAI AV3 +0.00 MRPC Special In SG C 36 22 NQI 7C +24.88 BOBBIN SG C ETL TSC +2.08 BOBBIN SG C 42 39 DNG AV2 +3.19 BOBBIN SG C 43 39 HQI AV2 +5.05 BOBBIN SG C SAI AV2 +5.61 MRPC Special In SG C 43 40 DNG AV2 +5.70 BOBBIN I SG C SAI AV2 +6.15 MRPC Special In SG C 43 42 DNG AV4 +27.94 BOBBIN i SG C 44 40 DNG AV2 +5.64 BOBBIN SC C SAI AV2 +6.10 MRPC Specia? In SG C 45 40 DNG AV2 +6.18 BOBBIN SG C SAI AV2 +6.44 MRPC Specia) in SG C 45 47 ADR AV2 +14.18 BOBBIN SG C VOL AV2 +14.88 MRPC Special In Total Indications Found = 60 Total Tubes Found = 29 i Total Tubes in Input File = 29 r -}}