GPU Nuclear h

g{

P.O. Box 480 Middletown, Pennsylvania 17057 717-944-7621 Writer's Direct Dial Nurnber:

July 21, 1982 4400-82-L-0119 TMI Program Office Attn:

Mr. L. H. Barrett, Deputy Program Director US Nuclear Regulatory Commission c/o Three Mile Island Nuclear Station Washington, DC 20555

Dear Sir:

Three Mile Island Nuclear Station, Unit 2 (TMI-2)

Operating License No. DPR-73 Docket No. 50-320 CRDM Leadscrew Uncoupling The purpose of this letter is to inform you of our intent to uncouple all CRDM leadscrews immediately following the Quick Look Project.

It is our intent to only attempt uncoupling the leadscrews. Parking the leadscrews will not be attempted. The uncoupling activities will be accomplished utilizing procedures previously developed and approved to Technical Specification 6.8.2.

The proposed activities will cover a period of approximately three to four weeks. Based on the results of the Quick Look, an assesscent will be made to determine if the RCS heatup rate will allow the RCS to remain unpressurized and drained for the extra time period. As discussed in the Quick Look Safety Evaluation, contingency plans and emergency procedures are available, should the RCS temperature approach the limit. The proposed activities are bounded by the safety evaluation reports previously submitted to the NRC for the APSR Insertion and for the Quick Look Project.

Both Safety Evalur tionshave been reviewed and accepted by the staff.

There will be no additional criticality, boron dilution, or other safety concerns above those addressed in the referenced Safety Evaluations.

The uncoupling of the leadscrews can be accomplished without undue risk to the health and safety of the public, and does not constitute an unreviewed safety question. Therefore, GPU proposes to uncouple the CRDM leadscrews as described above.

qychrely

/

8207280167 820721 PDR ADOCK 05000320 J

. Barton P

PDR t ng Director, TMI-2 JJB/RBS/jep)6b7 CC: B. J. Snyder, Program Director - TMI Program Office GPU Nuclear is a part of the General Public Utilities System}}