Amends 64 & 29 to Licenses NPF-39 & NPF-85,respectively, Revising TS to Allow One Required on-shift SRO Position to Be Combined W/Required Shift Technical Advisor Position
ML20058B490
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 11/15/1993
From: Larry Nicholson
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20058B491 List:
References
NUDOCS 9312020091
Download: ML20058B490 (10)


Text

_

1

'l fo otag y,_

\\

UNITED STATES i

S NUCLEAR REGULATORY COMMISSION i

WASHINGTON, D.C. 20556 J001

-l

/

i PHILADELPHIA ELECTRIC COMPANY DOCKET NO. 50-352 1

LIMERICK GENERATING STATION. UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 64 License No. NPF-39 j

1.

The Nuclear Regulatory Comission (the Commission) has found that:

A.

The application for amendment by Philadelphia Electric-Company (the 3

licensee) dated July 16, 1993,. complies with the standards and i

requirements cf the Atomic Energy Act of 1954, as amended (the Act),

l l

and the Ccamission's rules and regulations set forth in 10 CFR l

Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission, a

C.

There is reasonable assurance (i) that the activities authorized by i

this amendment can be conducted without endangering the health and safety of the public,.and (ii) that such activities will be conducted in compliance with the Comission's-regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and i

E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comissior 's regulations and all applicable requirements have been satisfied.

9312O20091 931115 PDR ADOCK 05000352 p

PDR s

i l

Il l

.i t

. i 2.

Accordingly, the license is amended by changes to the Technical j

Specifications as indicated in the attachment to this license amendment,.

j

.and paragraph 2.C.(2) of Facility Operating License No. NPF-39 is.hereby

.l amended to read as follows:

~

~

l Technical Specifications ~

.i The Technical Specifications contained in Appendix A'and the Environmental l

Protection Plan contained in Appendix B,.as revised through Amendment No.

64, are hereby incorporated into this. license.

Philadelphia Electric Company shall operate the facility.in accordance with the Technical l

Specifications and the Environmental Protection Plan.

j 3.

This license amendment is effective as of its date 'of issuance.

l L

FOR THE NUCLEAR REGULATORY

  • COMMISSION-l l

I S/

j A

Larry.-Nicholson, Acting Director j

Proj t Directorate-I-2 Division of Reactor Projects.I/II Office of Nuclear Reactor Regulation

Attachment:

f Changes to the i

Technical Specifications Date of Issuance:

November 15. 1993 l

I

-3

'i i

.~

-.....t

i a

i l.

'{

2 ATTACHMENT TO LICENSE AMENDMENT NO. 64 i

FACILITY OPERATING LICENSE NO. NPF-39 DOCKET NO. 50-352 Replace the following pages of the Appendix A Technical Specifications with' the attached pages. The revised pages are identified by Amendment number and contain vertical lines indicating the area of change.

~

Remove Insert i

6-5 6-5 6 6-6 I

l t

i t

h l

l t

l i

1 1

-; l l

.. ~

r r

TABLE 6.2.2-1 MINIMUM SHIFT CREW COMPOSITION TWO UNITS WITH A COMMON CONTROL ROOM WITH UNIT 2 IN CONDITION 4 OR 5 OR DEFUELED POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION i

CONDITION 1, 2, or 3

~ CONDITION 4 OR S i

SS 1*

1*

~

SRO 1*

1*

R0 2

1 2**

NLO 2

None l _

STA 1***

WITH UNIT 2 IN CONDITION 1, 2, OR 3-POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION i

CONDITION 1, 2, or 3 CONDITION 4 or 5 SS 1*

1*

SRO 1*

1*

R0 2**

1 NLO 2**

1' STA 1*,***

None l

t TABLE NOTATIONS I

  • Individual may fill the same position on Unit 2.
    • 0ne of the two required individuals may fill the same position on Unit 2.

l

      • The STA position may be filled by the on-shift Shift Superintendent, Shift Supervisor or other SRO provided the individual meets the 1985 NRC Policy Statement on Engineering Expertise on Shift.

SS - Shift Superintendent or Shift Supervisor with a Senior Operator license

)

on Unit 1.

I l

SR0 - Individual with a Senior Operator license on Unit 1.

1 l

R0 - Individual with an Operator license on Unit 1.

NLO - Non-licensed operator properly qualified to-support the unit to which assigned.

STA - Shift Technical Advisor Except for Shift Supervision (SS), the shift crew composition may be one less than the minimum requirements of Table 6.2.2-1 for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the shift crew compo-sition to within the minimum requirements of Table 6.2.2-1.

This provision 1

does not permit any shift crew position to be unmanned upon shift change due to an oncoming shift crewman being late or absent.

During any absence of Shift Supervision (SS) from the control room while the unit is in OPERATIONAL CONDITION 1, 2, or 3, an individual with a valid Senior Operator. license shall be designated to assume the control room command function. During any absence of Shift Supervision from the control room while the unit is in OPERATIONAL CONDITION 4 l

or 5, an individual with a valid Senior Operator license or Operator license

(

shall be designated to assume the control room connand function.

l LIMERICK - UNIT 1 6-5 Amendment No. 28, 33, 64 l

l

_. _, _ -, _,.. ~.... _ _ _

ADMINISTRATIVE CONTROLS 6.2.3 INDEPENDENT SAFETY ENGINEERING GROUP (ISEG)

FUNCTION 6.2.3.1 The ISEG shall function to examine unit operating characteristics, NRC issuances, industry advisories, Licensee Event Reports, and other sources of unit design and operating experience information, including units of similar design, which may indicate areas for improving unit safety. The ISEG shall make detailed recommendations for revised procedures, equipment modifications, maintenance activities, operations activities, or other means of improving unit safety. Such recommendations shall be submitted through the General Manager-Nuclear Quality Assurance to the Executive Vice President-Nuclear.

COMPOSITION 6.2.3.2 The Limerick ISEG shall be composed of at least five, dedicated, full-time engineers, including the ISEG Superintendent, located onsite. Each shall have a bachelor's degree in engineering or related science and at least two years professional level experience in his or her field. The Limerick'ISEG Superintendent shall have at least six years of experience in the nuclear field.

The LGS ISEG reports to the General Manager-Nuclear Quality Assurance.

e RESPONSIBILITIES 6.2.3.3 The ISEG shall be responsible for maintaining surveillance of unit activities to provide independent verification

  • that these activities are performed correctly and that human errors are reduced as much as practical.

RECORDS 6.2.3.4 Records of activities performed by the ISEG shall be prepared, maintained, and forwarded each calendar month to the General Manager-Nuclear Quality Assurance.

6.2.4 SHIFT TECHNICAL ADVISOR 6.2.4.1 The Shift Technical Advisor shall provide advisory technical support to Shift Supervision in the areas of thermal hydraulics, reactor engineering, and plant analysis with regard to safe operation of the unit.

The Shift Technical Advisor shall meet the qualifications specified by the 1985 NRC Policy Statement on Engineering Expertise on Shift.

6.3 UNIT STAFF OVALIFICATIONS 6.3.1 Each member of the unit staff shall meet or exceed the minimum qualifications of ANSI /ANS 3.1-1978 for comparable positions, except for the Senior Health Physicist who shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975, and the licensed operators who shall comply with the requirements of 10CFR55.

oNot responsible for sign-off function.

i LIMERICK - UNIT 1 6-6 Amendment No. 10, 35, 5%,

64

I f

g UNITED STATES j

, j.

NUCLEAR REGULATORY COMMISSION

't WASHINGTON. D.C. 20555-0001

\\

l r

PHILADELPHIA ELECTRIC COMPANY DOCKET NO. 50-353 I

l LIMERICK GENERATING STATION.' UNIT 2 l

l AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 29

[

License No. NPF-85 1.

The Nuclear Regulatory Comission (the Comission) has found that:

i A.

The application for amendment by Philedelphia Electric Company (the licensee) dated July 16, 1993, complies with the standards and requirements of the-Atomic Energy Act of 1954, as amended (the Act),

and the Comission's rules and regulations set forth in 10 CFR' i

Chapter I; B.

The facility will operate in conformity with the application, the i

i provisions of the Act, and the rules and regulations of the i

Comission; C.

There is reasonable assurance (i) that the activities ' authorized _ by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; i

l D.

The issuance of this amendment will not be inimical to the comon I

defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

. 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-85 is hereby amended to read as follows:

Technical Snecifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.

29, are hereby incorporated into this license.

Philadelphia Electric Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

)I

/b g

Larr,

. Nicholson, Acting Director Proj kt Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

November 15, 1993 l

l l

l I

f.*

O ATTACHMENT TO LICENSE AMENDMENT NO. 29 FACILITY OPERATING LICENSE NO. NPF-85 DOCKET NO. 50-353 Replace the following pages of the Appendix A Technical Specifications with the attached pages. The revised pages are identified by Amendment number and contain vertical lines indicating the area of change.

I Remove Insert 6-5 6-5

{

6-6 6-6 e

e s

I l

i TABLE 6.2.2-1 MINIMUM SHIFT CREW COMPOSITION TWO UNITS WITH A COMMON CONTROL ROOM t

WITH UNIT 1 IN CONDITION 4 OR 5 OR DEFUELED NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION POSITION CONDIT!0'.1, 2, or 3 CONDITION 4 OR 5

[

SS 1*

1*

SR0 1*

1*

R0 2

1 i

NLO 2

2**

i STA 1***

None i,

WITH UNIT 1 IN CONDITION 1, 2, OR 3 NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION POSITION CONDITION 1, 2, or 3 CONDITION 4 or 5 l

l SS 1*

1*-

SRO 1*

1*

l RO 2**

1 NLO 2**

1 STA

]*,***

None 1

TABLE NOTATIONS

  • Individual may fill the same position on Unit 1.
    • 0ne of the two required individuals may fill the same position on Unit 1.

i

      • The STA position may be filled by the on-shift Shift Superintendent, Shift Supervisor or other SRO provided the individual meets the 1985 NRC Policy Statement on Engineering Expertise on Shift.

SS - Shift Superintendent or Shift Supervisor with a Senior Operator license on Unit 2.

SR0 - Individual with a Senior Operator license on Unit 2.

R0 - Individual with an Operator license on Unit 2.

NLO - Non-licensed operator properly qualified to support the unit to which assigned.

STA - Shift Technical Advisor Except for Shift Supervision (SS), the shift crew composition may be one less than the minimum requirements of Table 6.2.2-1 for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew l

members provided immediate action is taken to restore the' shift crew compo-l sition to within the minimum requirements of Table 6.2.2-1.

This provision does not permit any shift crew position to be unmanned upon shift change due to an oncoming shift crewman being late or absent.

1 I

During any absence of Shift Supervision (SS) from the control room while the unit -

is in OPERATIONAL CONDITION 1, 2, or 3, an individual with a valid Senior Operator license shall be designated to assume the control room command function.

During any absence of Shift Supervision from the control room while the unit is in OPERATIONAL CONDITION 4 or 5, an individual with a valid Senior Operator license or Operator license shall be designated to assume the control room command function, i

LIMERICK - UNIT 2 6-5 Amendment No. 29 i

l

~

i ADMINISTRATIVE CONTROLS 6.2.3 INDEPENDENT SAFETY ENGINEERING GROUP (ISEG)

FUNCTION 6.2.3.1 The ISEG shall function to examine unit operating characteristics, NRC issuances, industry advisories, Licensee Event Reports, and other sources of unit design and operating experience information, including units of similar design, which may indicate areas for improving unit safety. The ISEG shall make detailed recommendations for revised procedures, equipment modifications, maintenance activities, operations activities, or other means of improving unit safety. Such recommendations shall be submitted through the General Manager-Nuclear Quality Assurance to the Executive Vice President-Nuclear.

COMPOSITION 6.2.3.2 The Limerick ISEG shall be composed of at least five dedicated, full-time engineers, including the ISEG Superintendent, located onsite. Each shall have a bachelor's degree in engineering or related science and at least two years professional level experience in his or her field. The Limerick ISEG Superintendent shall have at least six years of experience in the nuclear field.

The LGS ISEG reports to the General Manager-Nuclear Quality Assurance.

. '.. RESPONSIBILITIES 6.2.3.3 The ISEG shall be responsible for maintaining surveillance of unit activities to provide independent verification

  • that these activities are performed correctly and that human errors are reduced as much as practical.

RECORDS l

6.2.3.4 Records of activities performed by the ISEG shall be prepared, maintained, and forwarded each calendar month to the General Manager-Nuclear Quality Assurance.

6.2.4 SHIFT TECHNICAL ADVISOR 6.2.4.1

' The Shift Technical Advisor shall provide. advisory technical support to Shift l

Supervision in the areas of thermal hydraulics, reactor engineering, and plant analysis with regard to safe operation of the unit.

The Shift Technical Advisor shall meet the qualifications specified by the 1985 NRC Policy Statement on Engineering Expertise on Shift.

6.3 UNIT STAFF OVALIFICATIONS 6.3.1 Each member of unit staff shall meet or exceed the minimum qualifications of ANSI /ANS 3.1-1978 for comparable positions, except for the Senior Health Physicist who shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975, and the licensed operators who shall comply with the requirements of 10CFR55.

  • Not responsible for sign-off function.

i LIMERICK - UNIT 2 6-6 Amendment No. 2, 20, 29

-