Amend 61 to License NPF-43,revising Tech Spec by Removing Footnote on LCO to Section 3.6.4.1 Re Suppression Chamber Drywell Vacuum Breakers
ML20058A663
Person / Time
Site: Fermi 
(NPF-43-A-061, NPF-43-A-61)
Issue date: 10/22/1990
From: Pierson R
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20058A665 List:
References
NUDOCS 9010290066
Download: ML20058A663 (5)


Text

.

dus d'

o UNITED STATES

'g

.["

y, NUCLEAR REGULATORY COMMISSION

~

.V.

r,,

ej WASHINGTON, D. C. 20556 l

....+

DETROIT EDISON COMPANY DOCKET NO. 50 341 FERMI-2 i

AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 61 License No. NPF-43 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by the Detroit Edison Company (the licensee) dated December 7, 1989, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

.The facility will operate in conformity with the app'sication, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized 1

by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; 1

D.

The issuance of this amendment will not be inimical to_the common

-l defense and security or to the health and safety of the public, and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations' and all applicable requirements have been satisfied.

2.

,Accordingly, the license is. amended by changes to the Technical Specifications as indicated in the attachment to this-license amendment

.and-paragraph 2.C.(2) of Facility Operating License No.-NPF-43 is hereby amended to read-as follows:

Technical Specifications and Environmental Protection Plan

.The Tec'hnical Specificttions contained 'in Appendix A, as revised-through. Amendment No. 61, and the Environmental Protection Plan o

contained in Appendix B, are hereby incorporated in the license.

Deco-shall operate the facility:in accordance with the Technical Specifications and the Environmental Protection Plan.

9010290066 901022 PDR ADOCK 05000341 P

PDC 1

j l *-

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

(,

Robert C. Pierson, Director Project Directorate 111-1 Division of Reactor Projects - III, IV, V & Special Projects Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: October 22,1990

+

s'

N ATTACHMENT TO LICENSE AMENDMENT NO. M FACILITY OPERATING LICENSE NO. NPF-43 DOCKET NO. 50-341 Replace the following pages of the Appendix "A" Technical Specifications with the attached pages. The revised pages are identified by Amendment number and contain a vertical line indicating the area of change.

l REMOVE INSERT 3/4 6-47*

3/4 6-47*

l 3/4 6-48 3/4 6-48 L;,

  • 0verleaf page provided to maintain document completeness No changes contained on this page..

1 S

d

g.

TABLE 3.3.3-1 (continued)

PRIMARY CONTAINMENT ISOLATION VALVES TABLE NOTATIONS (Continued)

(k)

Will automatically close when a) RCIC Turbine Steam Stop Valve E51-F045 closes or b) RCIC Turbine Governor Trip and Throttle Valve E51-F059 closes.

(1)

Will automatically close as a result of the conditions listed in Note (k) above, as well as when RCIC flow is greater than 130 gpm.

(m)

These valves are actuated by remote manual key-locked switches and will cut the TIP cable and seal off the TIP guide tube when actuated.

These valves are squib-fired.

(n)

May be closed remotely as a secondary actuation mode to reverse flow.

(o)

Valves realign automatically on a reactor scram signal.

(p)

Thermal relief valves.

(q)

Locked closed.

(r)

Not subject to Type C leakage tests.

l.

~.

i8 FERMI - UNIT 2 3/4 6-47

s CONTAINMENT SYSTEMS 3/4.6.4 VACUUM RELIEF SUPPRESSION CHAMBER - DRYWELL VACUUM BREAKER}

LIMITING CONDITION FOR OPERATION 3.6.4.1 All suppression chamber - drywell vacuum breakers shall be closed and at least 10 vacuum breakers shall be OPERABLE.

APPLICABILITY: OPERATIONAL CONDITIONS 1, 2, and 3.

ACTION:

a.

With one of the above required vacuum breakers inoperable for opening but known to be closed, restore the inoperable vacuum breaker to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, b.

With one or more suppression chamber - drywell vacuum breakers open, close the open vacuum breaker (s) within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

c.

With one of the closed position indicators of one or more suppression chamber - drywell vacuum breaker (s) inoperable, verify the associated vacuum breaker and all other breakers to be closed within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and:

1.

Verify the vacuum breaker (s) with the inoperable position indicator to be closed by demonstrating the other indicator to be OPERABLE within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and at least once per 14 days thereafter, or 2.

Verify.the vacuum breaker (s) with the inoperable position indicator to be closed by conducting a test which demonstrates that the drywell-to-suppression chamber is maintained at greater than or equal to 0.5 psi for one hour without makeup within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and at least once per 14-day thereafter.

Otherwise, be in at least HOT SHUTDOWN within the nex 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, d.-

With one of the closed position indicators of one or more suppression chamber - drywell vacuum breaker (s) indicating open and the redundant-closed position indicator indicating closed after a suppression chamber

- drywell vacuum breaker opening as a result of a-steam release,.within -

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, cycle the' applicable valve (s) to determine which of the redundant indicators is OPERABLE.

.r FERMI - UNIT 2 3/4 6-48 Amendment No. 32, 61

-.