ML20057F521
| ML20057F521 | |
| Person / Time | |
|---|---|
| Issue date: | 10/12/1993 |
| From: | Richings H Office of Nuclear Reactor Regulation |
| To: | Rosalyn Jones Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 9310180131 | |
| Download: ML20057F521 (2) | |
Text
.
AR Rf g
/
I UNITED STATES t
{ M ;di E fk NUCLEAR REGULATORY COMMISSION j
WASHINGTON, D.C. 20565-0001
%...s j'
October 12, 1993
.+
MEMORANDUM FOR:
Robert C. Jones, Chief Reactor Systems Branch i
Division of Systems Safety and Analysis THRU:
Laurence E. Phillips, Section Chief k Core Performance Section Reactor Systems Branch Division of Systems Safety and Analysis FROM:
Howard Richings, Sr. Reactor Engineer Core Performance Section Reactor Systems Branch Division of Systems Safety and Analysis j
SUBJECT:
MEETING WITH BWROG ON BWR THERMAL-HYDRAULIC-STABILITY PURPOSE:
Discussion of (1) LTS Plans Update (Briefly) and (2) ATWS Stability and Associated EOP DATE & TIME:
Thursday, October 28, 1993 8:30am - 2:00pm l
LOCATION:
One White Flint North, Room 8B11 11555 Rockville Pike Rockville, MD 20852 r
PARTICIPANTS:
NRC; R. Jones, L.
Phillips, H.
- Richings, H. Scott BWROG:
T. Rausch, B. Williamson ORNL:
J. March-Leuba l
'Howard Richin s, Sr. Reactor Engineer Core Performance Section Reactor Systems Branch Division of Systems Safety and Analysis cc:
See next page Meetings between NRC technical staff and applicants, or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement of NRC Staff Policy," 43 Federal Reaister 28058, 6/28/78.
Portions of this meeting may be closed to the public to allow presentation of proprietary information.
Contact:
H. Richings, SRXB/ DST /504-2888
[
& p 6 f/h NF.C HLE CENTEi! COPY g.g uv
(\\/gi y)a xgfff5,3./f#""t 93101s0131 931012 4MJ PDR TOPRP EMVCENE 150045 PDR
..-.-.. -.. -.- -... ~-.-.--
o October 12, 1993 E ETING NOTICE DISTRIBUTION Central File NRC Participants SRXB R/F LPhillips j
NRC PDR HRichings OTSB LShotkin (NLN-353) j JMTaylor (17G-13)
HScott (NIE-3 53 )
TMurley/FMiraglia (12G-18)
PBoehnert (P-315) j WRussell (12G-18)
HWood (NLS-314)
BSheron (NL-007)
JPartlow (12G-18)
DCrutchfield (12G-18)
SVarga (14E-4)
JRichardson (7D-26)
AThadani (8E-2)
MVirgilio (13E-4)
AChaffee (11A-1)
BBoger (13A-2)
GLainas (14H-3)
JZwolinski (13H-24)
OGC-WF1 (15B-18)
EJordan (MNBB-3701)
ETana (12G-18)
YOverton (12E-4)
ACRS (10)
GPA/PA (2G-5)
Guard Desk (OWFN)
T.
Rausch J. March-Leuba H.
Pfefferlen B. Williamson
....