ML20057F177

From kanterella
Jump to navigation Jump to search
Notifies of Completion of ISI of SG Tubes,Including Number of Tubes Repaired or Removed from Svc in Each Sg,Per TS Section 4.19.5.a
ML20057F177
Person / Time
Site: Crane 
Issue date: 10/06/1993
From: Broughton T
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
C311-93-2146, NUDOCS 9310140253
Download: ML20057F177 (1)


Text

m n

GPU Nuclear Corporation 5 i Nuclear m:ntr*

Middletown, Pennsylvania 17057-0480 (717) 944-7621 Writer's Direct Dia1 Number:

(717) 948-8005 October 6, 1993 C311-93-2146 t

U. S. Nuclear Regulatory Commission

~ Attn: Document Control Desk Washington, D.C.

20555

Dear Sir:

Subject:

Three Mile Island Nuclear Station, Unit I (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 OTSG Tubes' Post Inservice Inspection Report for Refueling Interval 10R This letter fulfills the requirement of THI-1 Technical Specification section 4.19.5.a, to report to the NRC, within 15 days of the completion of inservice inspection of the steam generator tubes, the number of tubes repaired or removed from service in each steam generator.

During the 10R refueling interval, evaluation of eddy current inspection results determined the need to repair one tube and remove one defective tube from service by plugging. Specifically, one tube was repaired by sleeving in steam generator "A" and one tube was plugged in steam generator "B."

The plugging was completed on October 2, 1993.

Since their fabrication, a total of 1268 tubes have been removed from service in steam generator "A" and 373 in steam generator "B".

Sincerely, b~

T. G. Br 'ghton Vice President & Director, TM1-1 WGH 130030 9310140253 931006 Attachment PDR ADOCK 05000289 $

G PDR b

cc: Administrator, Region I TMI Senior Project Manager 0

)

TMI Senior Resident Inspector f

GPU Nuclear Corporation is a subsidiary of General Public Utilities Corporation I

ij i