7590-01 UNITED STATES NUCLEAR REGVLATORY COMMISSION NORTHEAST NUCLEAR ENERGY COMPANY DOCKET N0. 50-423 NOTICE OF CONSIDERATION OF ISSVANCE OF AMENDMENT TO FACILITY OPERATING LICENSE. PROPOSED NO SIGNIFICANT HAZARDS CONSIDERATION DETERMINATION. AND OPPORTUNITY FOR A HEARING The U.S. Nuclear Regulatory Commission (the Commission) is considering issuance of an amendment to Facility Operating License No. NPF-49, issued to Northeast Nuclear Energy Company (the licensee), for operation of the Millstone Nuclear Power Station, Unit No. 3, located in New London County, Connecticut.

The proposed amendment would revise the trip setpoints associated with the reactor trip system interlock P-10.

The P-10 reactor trip system interlock performs certain functions upon an increase in reactor power level (such as activating low reactor coolant flow reactor protection system (RPS) trips) and other functions upon a decrease in reactor power level (such as activating the intermediate range flux monitors). The present setpoint values specified in the Technical Specifications are conservative, but impractical for plant operation. The licensee has prcposed new setpoint values that retain the conservatism and are practical for plant operation.

Because the present Technical Specifications are impractical for plant operation, the Technical Specifications must be changed before plant operation resumes. The plant is presently shutdown for refueling and resumption of

)

operations is expected by October 5, 1993.

In order to process the proposed license amendment in time to permit scheduled resumption of operation exigent 9310010104 930915 1

PDR ADDCK 05000423 P

PDR.,

. approval is required. The licensee has stated that the exigent situation could not have been avoided because the understanding that the Technical Specification needed to be modified was reached on September 8, 1993.

Before isssuance of the proposed license amendment, the Commission will have made findings required by the Atomic Energy Act of 1954, as amended (the Act) and the Commission's regulations.

Pursuant to 10 CFR 50.91(a)(6) for amendments to be granted under exigent circumstances, the NRC staff must determine that the amendment request involves no significant hazards consideration. Under the Commission's regulations in 10 CFR 50.92, this means that operation of the facility in accordance with the proposed amendment would not (1) involve a significant increase in the probability or consequences of an accident previously evaluated; or (2) create the possibility of a new or different kind of accident from any accident previously evaluated; or (3) involve a significant reduction in a margin of safety. As required by 10 CFR 50.91(a), the licensee has provided its analysis of the issue of no significant hazards consideration (SHC), which is presented below:

The proposed changes do not involve an SHC because the changes would not:

1.

Involve a significant increase in the probability or consequences of an accident previously evaluated.

The proposed changes modify the trip setpoints associated with the P-10 interlock (Table 2.2-1, Functional Units 18.b.1 and 18.e). The P-10 interlock is associated with the following reactor-trips that are credited in the safety analyses:

Pressurizer Pressure - Low Pressurizer Water Level - High j

Reactor Coolant Flow - Low (more than one loop)

Reactor Coolant Pump Shaft Speed - Low i

i i

- Based on this list of reactor trips, the accidents potentially impacted include:

Loss of Forced Reactor Coolant Flow Rod Withdrawal from Subcritical Loss of Load Reactor Coolant Pump Shaft Seizure (locked rotor)

The proposed changes are intended to explicitly account for the dead band inherent in the bistable which precludes having both settings at 10% of the RTP[ reactor thermal power). The " allowable value" listed in Table 2.2-1 for Functional Unit 18.b.1 is [less than or equal to] 12.1% of the RTP and the " allowable value" listed in Table 2.2-1 for Functional Unit 18.e is [ greater than or equal to] 7.9% of the RTP. The " allowable values" of the limiting safety system settings are the values that assure that the associated design basis assumptions are valid. There are no changes proposed to these

" allowable values" associated with the P-10 interlock. Since, the allowable values are not changing, the changes do not have any impact on the design basis analyses. Therefore, the changes cannot increase the probability nor consequences of an accident previously evaluated.

2.

Create the possibility of a new or different kind of accident from any previously evaluated.

The proposed changes do not affect the plant operation or introduce any new failure mechanisms. Therefore, the proposed changes will not create the possibility of a new or different kind of accident from any previously evaluated.

3.

Involve a significant reduction in a margin of safety.

The allowable values in the technical specifications are the values that assure the validity of the design basis assumptions. The trip setpoint provides a value that limits the potential for exceeding the allowable value and thereby limits the potential for exceeding any design basis assumption. Based on this, the design basis assumptions are not impacted. Since the allowable values are not changing, the changes do not have any impact on the design basis analyses. Therefore, the proposed changes will not involve a significant reduction in a margin of safety.

The NRC staff has reviewed the licensee's analysis and, based on this review, it appears that the three standards of 10 CFR 50.92(c) are satisfied. Therefore, the NRC staff proposes to determine that the amendment request involves no significant hazards consideration.

4

_4_

The Commission is seeking public comments on this proposed determination. Any comments received within 15 days after the date of publication of this notice will be considered in making any final determination.

l Normally, the Commission will not issue the amendment until the expiration of the 15-day notice period.

However, should circumstances change during the notice period, such that failure to act in a timely way t

would result, for example, in derating or shutdown of the facility, the Commission may issue the license amendment before the expiration of the 15-day notice period, provided that its final determination is that the amendment involves no significant hazards consideration. The final determination will cor aider all public and State comments received. Should the Commission take this action, it will publish in the FEDERAL REGISTER a notice of issuance.

The Commission expects that the need to take this j

action will occur very infrequently.

Written comments may be submitted by mail to the Rules Review and Directives Branch, Division of Freedom of Information and Publications i

Services, Office of Administration, U.S. Nuclea Regulatory Commission, Washington, DC 20555, and should cite the publication date and page number of this FEDERAL REGISTER notice. Written comments may also be delivered to Room P-223, Phillips Building, 7920 Norfolk Avenue, Bethesda, Maryland, from 7:30 a.m. to 4:15 p.m. Federal workdays. Copies of written comments received may be examined at the NRC Public Document Room, the Gelman Building, 2120 L 3

i Street, NW., Washington, DC 20555.

1

On September 27, 1993, correction was sent to Office of the Federal Register _

1 to change hearing request date to October 22, 1993.

The filing of requests for hearing and petitions for leave to intervene is discussed below.

By October 7,1993

, the licensee may file a request for a hearing with respect to issuance of the amendment to the subject facility operating license and any person whose interest may be affected by this proceeding and who wishes to participate as a party in the proceeding must file a written request for a hearing and a petition for leave to intervene.

Requetts for a hearing and a petition for leave to intervene shall be filed in accordance with the Commission's " Rules of Practice for Domestic Licensing Proceedings" in 10 CFR Part 2.

Interested persons should consult a current copy of 10 CFR 2.714 which is available at the Commission's Public Document Room, the Gelman Building, 2120 L Street, NW., Washington, DC 20555 and at the local public document room located at the Learning Resources Center, Thames Valley State Technical College, 574 New London Turnpike, Norwich, Connecticut 06360.

If a request for a hearing or petition for leave to intervene is filed by the above date, the Commission or an Atomic Safety and Licensing Board, designated by the Commission or by the Chairman of the Atomic Safety and Licensing Board Panel, will rule on the request and/or petition; and the Secretary or the designated Atomic Safety and Licensing Board will issue a notice of hearing or an oppropriate order.

As required by 10 CFP. 2.714, a petition for leave to intervene shall set forth with particularity the interest of the petitioner in the proceeding, and how that interest may be affected by the results of the proceeding. The petition should specifically explain the reasons why intervention should be permitted with particular reference to the following

. factors:

(1) the nature of the petitioner's right under the Act to be made j

a party to the proceeding; (2) the nature and extent of the petitioner's property, financial, or other interest in the proceeding; and (3) the possible effect of any order which may be entered in the proceeding on the petitioner's interest.

The petition should also identify the specific aspect (s) of the subject matter of the proceeding as to which petitioner wishes to intervene.

Any person who has filed a petition for leave to intervene or who has been admitted as a party may amend the petition without requesting leave of the Board up to 15 days prior to the first prehearing conference scheduled in the proceeding, but such an amended petition must satisfy the specificity requirements described above.

Not later than 15 days prior to the first prehearing conference scheduled in the proceeding, a petitioner shall file a supplement to the petition to intervene which must include a list of the contentions which are sought to be litigated in the matter.

Each contention must cunsist of a specific statement of the issue of law or fact to be raised or P

controverted.

In addition, the petitioner shall provide a brief 1

exp!anation of the bases of the contention and a concise statement of the alleged facts or expert opinion which support the contention and on which the petitioner intends to rely in proving the contention at the hearing.

The petitioner must also provide references to those specific sources and documents of which the petitioner is aware and on which the petitioner intends to rely to establish those facts or expert opinion.

Petitioner must provide sufficient information to show that a genuine dispute exists with the applicant on a material issue of law or fact.

Contentions shall

. be limited to matters within the scope of the amendment under consideration. The contention must be one which, if proven, would entitle the petitioner to relief. A petitioner who fails to file such a supplement which satisfies these requirements with respect to at least one contention will not be permitted to participate as a party.

Those permitted to intervene become parties to the proceeding, subject to any limitations in the order granting leave to intervene, and have the opportunity to participate fully in the conduct of the hearing, including the opportunity to present evidence and cross-examine witnesses.

If the amendment is issued before the expiration of the 30-day hearing period, the Comission will make a final determination on the issue of no significant hazards consideration.

If a hearing is requested, the final determination will serve to decide when the hearing is held.

If the final determination is that the amendment request involves no significant hazards consideration, the Comission may issue the amendment and make it imediately effective, notwithstanding the request for a hearing. Any hearing held would take place after issuance of the amendment.

If the final determination is that the amendment request involves a significant hazards consideration, any hearing held would take place before the issuance of any amendment.

A request for a hearing or a petition for leave to intervene must be filed with the Secretary of the Comission, U.S. Nuclear Regulatory Comission, Washington, DC 20555, Attention: Docketing and Services Branch, or may be delivered to the Comission's Public Document Room, the

. Gelman Building, 2120 L Street, NW., Washington, DC 20555, by the above date. Where petitions are filed during the last 10 days of the notice period, it is requested that the petitioner promptly so inform the Commission by a toll-free telephone call to Western Union at 1-(800) 248-5100 (in Missouri 1-(800) 342-6700). The Western Union operator should be given Datagram Identification Number N1023 and the following message addressed to John F. Stolz, Director, Project Directorate I-4: petitioner's name and telephone number; date petition was mailed; plant name; and publication date and page number of this FEDERAL REGISTER notice. A copy of the petition should also be sent to the Office of the General Counsel, U.S.

Nuclear Regulatory Commission, Washington, DC 20555, and to Gerald Garfield, Esquire, Day, Berry & Howard, City Place, Hartford, Connecticut 06103-3499, attorney for the licensee.

Nontimely filings of petitions for leave to intervene, amended petitions, supplemental petitions and/or requests for hearing will not be entertained absent a determination by the Commission, the presiding officer or the presiding Atomic Safety and Licensing Board that the petition and/or request should be granted based upon a balancing of the factors specified in 10 CFR 2.714(a)(1)(i)-(v) and 2.714(d).

For further details with respect to this action, see the application for amendment dated September 14, 1993, which is available for public inspection at the Commission's Public Document Room, the Gelman Building,

_g_

2120 L Street, NW., Washington, DC 20555, and at the local public document room, located at the Learning Resources Center, Thames Valley State Technical College, 574 New London Turnpike, Norwich, Connecticut 06360.

Dated at Rockville, Maryland, this 15th day of September 1993.

FOR THE NUCLEAR REGULATORY COMMISSION l

.Q Vernon L. Rooney, Senipr Project Manager Project Directorate I-4 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation i