_&.,,
-
.
e
.
.
.
Docket Nos. 50-317
'
50-318
23.IS$j
Mr. Robert E. Denton
Vice President - Nuclear Energy
Baltimore Gas and Electric Company
Calvert Cliffs Nuclear Power Plant
1650 Calvert Cliffs Parkway
Lusby, Maryland 20657 - 4702
,
Dear Mr. Denton:
f
SUBJECT:
NOTICE OF VIOLATION NRC REGION I COMBINED INSPECTION
REPORT NOS. 50-317/93-21 AND 50-318/93-21
This letter transmits the NRC Region I Inspection Report for the announced inspection
conducted by Mr. R. Bhatia of this office from June 28,1993, to July 2,1993, at Calvert
Cliffs Units 1 and 2, in Lusby, Maryland. Mr. Bhatia discussed the fmdings of this
inspection with members of your staff at the conclusion of the inspection. Subsequent to this
,
inspection, on July 27,1993, the inspector reviewed additional information provided by your
!
staff to clarify cor.cerns of the cited violation included in this report.
i
The inspection was directed toward areas important to public health and safety. Areas
examined during this inspection included the resolution and corrective actions taken for open
items identified previously during the Electrical Distribution System Functional Inspection
(EDSFI). c in this scope, the inspection consisted of selective examinations of design
l
5
<
records, pc
- and representative records, interviews with personnel, and observations
'
.
by the inspme
Based upon the results of this inspection, it appears that one of your activities was in
,
violation of NRC requirements, as set forth in the Notice of Violation, enclosed herewith as
Appendix A. The violation has been categorized by severity level in accordance with the
" General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2,
Appendix C (Enforcement Policy). You are required to respond to the Notice of Violation.
In preparing your response, you should follow the instructions in Appendix A.
-
A:CC9321. INS
\\
I
ig\\
i
I
9309300213 9M923
E
d
ADOCK 05000317
E
G
h
.
..
_
SEP 23 73N
_
.
.
.
.
Mr. Robert E. Denton
2
It appears that the above violation was due to a' weakness in implementing your design
review process with regard to facility change requests. The facility change requests were
implemented without adequately reviewing the existing design parameters. This resulted in .
,
changing an important setpoint of the loss of coolant incident (LOCI) sequencer timer, which
>
was previously corrected during the EDSF1 inspection to prevent the overloading of the
t
!
In addition, the corrective actions for five previously identified issues were found to be
adequate and the items are closed. Your interim corrective actions pertaining to 'he
j
ventilation sys'.em were found to be adequate. However, additional long-term corrective
j
actions, as committed in your previous responses, require further NRC review; therefore,
,
this item is updated in this report and remains open.
l
,
!
Your cooperation with us in this matter is appreciated.
i
Sincerely,
,
i
oris -31 Sir,a:c y.
!
'
Jacque P. Durr,
.ief
Engineering Branch
Division of Reactor Safety
,
Enclosures:
1. Notice- of Violation
2. NRC Region I Combined Inspection Report Nos.
50-317/93-21 and 50-318/93-21
'
cc w/enci
G. Detter, Director, Nuclear Regulatory Matters (CCNPP)
R. McLean, Administrator, Nuclear Evaluations
i
J. Walter, Engineering Division, Public Service Commission of Maryland
i
K. Burger, Esquire, Maryland People's Counsel
R.'Ochs, Maryland Safe Energy Coalition
K. Abraham, PAO (2) All Inspection Reports
Public Document Room (PDR)
Ixcal Public Document Room (LPDR)
Nucler Safety Information Center (NSIC)
NRC Resident Inspector
State of Maryland (2)
A:CC9321. INS
i
i
.
._.
SEP 2 31931
~
,
j
..
'
i
.
Mr. Robert E. Denton
3
!
bec w/ encl
Region 1 Docket Room (with concurrences)
C. Cowgill, DRP
I
L. Nicholson, DRP
l
J. Yerokun, DRP
,
D. Weaver, DRP
P. Wilson - Calvert Cliffs
'
V. McCree, OEDO
-
R. Capra, NRR
D. Mcdonald, NRR
.
i
.
E
i
,
1
..
,
-
' fd
.
RI:DIb
.
/
1S
RI:DRS
rr I
Bhatia
Rtlan -
%$
q \\ 17
y
8/0/93
8/ J9
/93
A:CC9321. INS
OFFICIAL RECORD COPY
!
i
1
.
..
-
-.
i