September 16, 1993 p
U. S. Nuclear Regulatory Commission j
Attention:' Document Control Desk Washington, D. C.
20555 l
Subject:
McGuire Nuclear Station, Units 1 and 2 Docket Numbers 50-369 and 50-370 Inservice Inspection Plan (ISI)
Second Interval Plans for Unit 2 Relief Request 93-05 i
Dear Sir:
-The Commercial Service Date for McGuire Nuclear Station, h
Unit 2-is March 1, 1984.
As specified by Section XI of the i
ASME. Boiler and Pressure Vessel Code, the first interval for Unit 2 was from March 1, 1984 to March.1, 1994.
In accordance-withi10CFR50.55a(g)(4)(11), the ISI program for Unit 2 shall be' revised to comply with the requirements of the latest edition and addenda of the Code incorporated by reference in 10CFR50.55a(b)(2) twelve months prior to the i
start of second. inspection interval.
The latest edition of the Code that was referenced by paragraph (b) of 10CFR50.55a at that time was the 1989 edition of the Code, no addenda.
Pursuant to the requirements of 10CFR50.55a, please find
~
attached a~ copy.of the ISI plan for McGuire Nuclear Station-Unit'2 (VolumesEl and 2) to be used during the second interval.
In accordance with the requirements of.
- j 10CFR50.55a(g), the ISI plan for Unit 2 of McJuire Nuclear Station will be performed in accordance with tne 1989 i
P edition of the ASME Section XI Code.
r 1
/
h
't i
t o
29003ua i,\\
78893oo271930,26
- en ADocx osooo37o gg o
PDR gg3 a
umam wasma k
s a
U.
S. Nuclear Regulatory Commission September 16, 1993 page 2 To support your review of the ISI plan, marked up system piping layout drawings and system isometrics are being prepared.
These drawings will be submitted to you at a later date.
Further, some of the class B items do not have Calibration Blocks listed (Volume 2 Appendix A) because the 7
blocks themselves are in the course of preparation.
This information will, also, be provided at a later date.
Included within the ISI plan provided by this letter is a request for relief from certain inspection requirements that have been determined to be impractical.
Specifically, Volume 1 Section 9 of the ISI plan provides the relief request for NRC review.
Pursuant to 10CFR50.5Sa(g)(6), NRC approval of the enclosed relief is hereby requested.
An additional request for relief regarding IWF-5000 is currently in preparation and will be submitted at a later date, under a separate letter.
In Addition, please note that Volume 1 Section 1.2 of the attached ISI plan identifies the Code Cases that will be used during the second inspection interval for Unit 2.
All of the Code Cases identified are listed in revision 10 of NRC Regulatory Guide 1.147,_" Inservice Inspection Code Case Acceptability - ASME Section XI Division 1".
Accordingly, this letter provides our notification of intent to utilize the listed code cases during the second ISI interval for Unit 2.
By letter dated October 12, 1992, a copy of the ISI plan to be used during the second interval for McGuire, Unit 1 was submitted.
The letter identified a code case (Code Case N-491) that w;uld be utilized, but was not approved by the NRC yet and; thus, was not listed within Regulatory Guide 1.147..A submittal requesting NRC authorization to use this particular code case was to be submitted.
Subsequent to the October 12, 1992 letter, the NRC issued revision 10 to Regulatory Guide 1.147, which listed Code Case N-491.
As such, specific NRC authorization to use Code Case N-491 during the second ISI interval for Unit 1 is not necessary.
Please be advised that Code case N-491 will be used during the second ISI interval at McGuire, Unit 1 and that this letter serves as your notification of that fact.
f U.
S.
Nuclear Regulatory Commission l
September 16,.1993 i
page 3 i
i Please contact Paul Guill at (704) 875-4002 if there are any question regarding this submittal.
Very truly yours,
/
Ted C. McMeekin xc:
With Attachments
[
Mr.
S.
D.
Ebneter Regional Administrator, Region II l
U.
S.
Nuclear Regulatory Commission 101 Marietta Street, NW, Suite 2900 Atlanta Georgia 30323 t
Without Attachments Mr. George F. Maxwell 7
Senior NRC Resident Inspector, McGuire McGuire Nuclear Station Mr. Victor Nerses, Project Manager Office of Nuclear Reactor Regulation U.
S. Nuclear Regulatory Conaissior.
i One White Flint North, Mail Stop 9H3 Washington, D.C.
20555 Harry Payne, Commissioner of Labor At.tention: Joe Kapherr Director, Boiler & Pressure Vessel Division Department of Labor State of North Carolina 4 West Edenton Street Raleigh, North Carolina 27601 i
6
,