Requests Registration as User of Model 660B Package Identification Number USA 9033 B(U)
ML20057C124
Person / Time
Site: 07109033
Issue date: 09/17/1993
From: Eure L
NORFOLK SHIPBUILDING & DRYDOCK CORP.
To: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NSQA-93-0681, NSQA-93-681, NUDOCS 9309270104
Download: ML20057C124 (1)


Text

,

-e

.a(

RD/'5N/PE'S NORFOLK SHIPBullDING & DRYDOCK CORPORAT ION -

=====~

I:: = a s:::rr - "-

l i

1

.NSQA-93-0681 i

September 17, 1993 Mr. Charles E. MacDonald Chief Transportation Branch Division of Safeguards and Transportation,' Nuclear Material Safety and Safeguard, United States Nuclear Regulatory Commission Washington, DC 20555 l

t

Dear Mr. MacDonald:

t In accordance with 10 CFR-- 71. 72 (c). (3), Norfolk Shipbuilding Drydock Corporation #45-12042-01 requests to be registered as a j

user.of Amersham Corporation, Model 660B Package Identification i

Number USA 9033 B(U), under terms of Certificate of Compliance Number 9033 jssued to Amersham Corporation, Burlington,.MA.

l Very truly

ours, l

i

-Is

~1 L.T.

Euri Radiogr?

qupervisor i

.l

-l i

i O A 00'

- l 9309270104 930917:

5 PDR ADOCK 0:f109033 I)-

M

-}_ -

\\

C ppg g

l 4

E" CERTIFICATE OF COMPUANCE c era "

POR RADIOACTIVE ttATL~tALS PACKACes t cm,rr.ror aamp

. arviso. uneu

.**caAmasoewt-o to. unet eesossaam p

. tots muene s 9033 8

USA /9033/Bf til 1

7 S.fMEA eLX

. Thas certthcet. e eso.ed to co'TWy that the p. cit.geng.no contents descetbed in nem S heeow, meets the. ppa.catHe e.te,y et.nderna set forth m Tit 410. Code eneae,.i no on..

n n. -e.cs.o.no.no Tr.n. con i.on v n.a.o.ei~. i4er.n.c l

. th. c.n,nc ooe. ne re.e ih. con..ono,,,om corne ne. =a on,,mau ment v me,moum.on. e me u s o.oenm.ni e tron.oon.i.on, om.,

l

_,e

, -e...nc

. ~

,n, e,..n, co.ni,, moe..ni.n.cn tne,ec..e...

, e l

l a t e_came.g asuco cm. mt. Asis or. wrTv a.mys s,at,aoatgga,igo;pgo=

i t

Amersliam Corporation Amersham Corporation application dated i

40 North Avenue December 1,1989, as supplemented.

Burlington, MA 01803 l

I

. oocart meca 71-9033 4 ccNDftaONs The. oarttficate a conostion.I upon NWilleg th. roowerements of 10 Crn P.r171..s.ppiec.tne. and the concittone.pecified beiow j

l (a) Packaging (1) Model No.: 660, 660E, 600A, 660AE, 660B or 660BE

[

(2) Description i

A steel encased uranium shielded Gamma Ray Projector. Primary components censist of an outer steel shell, polyurethane potting i

material, uranium shield, *S" tube, and end plugs. The contents are i

securely positioned in the "S* tube by a source cable locking device and shipping plug. Tamper-proof seals are provided on the packaging. The r.aximum total weight of the package is approximately 53 pounds.

(3) Drawings The packaging is constructed in accordance with the following Technical Operations, Inc. Drawings:

(i)

Model No. 660B - Drawing No. 66025, Sheets 1, 2 and 3, Rev. 0; (ii)

Model No. 660 - Drawing No. 66025, Sheets 1, 2 and 3, Rev. B, i

and Sheet 4, Rev. -; or Drawing No. 66030, Sheets 1, 2, 3 and 4, Rev. -;

I (iii) Model No. 660A - Drawing No. 66030, Sheets 1, 2 and 3, Rev. As or Drawing No. 66030, Sheets 1, 2 and 3, Rev. B.

tiodel Nos. with an E suffix have an electrical circuit.

I (b) Contents s

I 4

(1) Type and form of material I

?

y Iridium-192 sources which meet the requirements of special form Q

  1. j radioactive material.

h L~L i

~,

$, p { ] } ] b/]( N d Mfw G s

ne,n xvar a

.c,

x----h -==-------.

conomons ecomon ea>

v i

i Page 2 - Certificate No. 9033 - Revision No. 8 - Docket No. 71-9033 j

j lI ll (2) Maximum quantity of material per package ll I

.I (1) 140 Curies for the Model No. 660B or 660BE package.

j l

(ii) 120 Curies for the Model No. 660, 660E, 660A or 660AE package.

)

l

_1 I

11 i

ll 6.

The source shall be secured in the shielded position of the packaging by the l

i i

source assembly. The source assembly inust be fabricated of materials capable of j

d,;

resisting a 1475 *F fire environment for one-half hour and maintaining their

!g i

positioning function. The source assembly must engage the locking device.

l l

The source assembly must be of sufficient length and diameter to provide lI

[l positive positioning of the source within the depleted uraniurn shield assembly.

]

h7 h

The source assembly for use with this packaging is limited to Technical Operations, Inc. Model No. 424-9 as shown in Technical Operations, Inc. Drawing lj l!

g No. 42409, Rev. B.

P

l l

'I l

8

!I h

The name plate must be fabricated of materials capable of resistin]

10 CFR Part 71 and maintaining its legibility.

!l!

'l i

l 9.

In addition to the requirements of Subpart G of 10 CFR Part 71:

I ll l

l' (a) The package must meet the Acceptance Test and Maintenance Program of Chapter

{l i

l 8.0 cf the application, as supplemented; and j

i (b) The package shall be prepared for shipment in accordance with the Operating g

j (l

Procedures in Chapter 7.0 of the application, as supplemented.

l

]l!

'l l 10. The package authorized by this certificate is hereby approved for use under I

general license provisions of 10 CFR 671.12.

j l

1l11.

lI l

Expiration date: October 31, 1995 l

I ll REFERENCES lI l

)jl Amersham Corporation Application dated December 1, 1989.

j l

i I

I

!I

!! Supplements dated: April 24, August 23, September 6, September 17, October 26 and s

f November 27, 1990.

lI 1

lI I

1

(

FOR THE U.S. NUCLEAR REGULATORY COMMISSION

]

II

!I

$/

I Charles E. MacDonald, Chief j

h Transportation Branch

!g (j

Division of Safeguards ll 1

ll and Transportation, NMSS lI

)

l si Date: DEC o 5 1990

'I

-- - - - - - - - - -, - - - - - - - - - - - - -- -- - - - - - - - - --,nxxxgr+ r- - - w w-v

...__./___.L.___.___

__-_1_____

^^

\\

X1 i E

N f j..x gf,'^-L:_=9cfj/ll.

a g{

g y

t...

s Y Il,

[xh gk g

s d, N

/ D a

N lx a

( A 1

\\\\

N

( 27 x

N '

N s s s

Q>$

pa

-p s

_~

b o

s I

\\

kg M

I g

=;

w lqk, e,h

'N e

EE 93o hg!

M

$!I N

t y

s pl v'

x e

3i N:

R 3 9 3 a di I

r1 m %x\\

. w: m~-w n

h 338

,/

a e.J v

!a_

k 3

d d

l I

x1 e

s 5

y a

3 R

A eJ mE 6_m g p T

~

lij P M8.

x_-

I lt E

sk 5[

g

%a s

s

[

    • s..

1 ll a li.i 3

hs, al 15

[-..

lilu, ili

.Ot i

e

( al [;

5

~ V-

\\!gli 4<;l'

(

t e

m.4 e

isg3 u_

st

g e

e o

Ir L, e c ? ;o I

o

$f I f

${h$a g

2b

'E d 8J

~R Ns E

v Ra J g i

5

\\

M G=t

/

r-f X

i_

is s s m e ms~s sssss 18 N Q[rf

[M [T I

N s

X N,, ' w N s

'a N

x.

d

\\

O

\\

\\

r

^

da ig D L )

A$h 31 n,

1.e4 m

c U"a "M M 55 I

}$E "8

11

!fi 3

e^

N@

9 t a.

N

o. U.yN 11 e

, ~,,

@m

~o up

\\._ _,_Iw %* h, 1

i L

t

/

r3

, __){y\\ ' / i@,'

gzgT-

\\

E

.i p,.

N

.r.)

y, i, ftl

?g n

44 e

i 2

'U P

a0IV ', l@y f--

b; j p i

R 4

i 1

e es.

, i 3

e

% :~)J' li M

i e

3 h

g lE j l f

g g

1 h

e

^5 IR$ ' I t

1 9 %

ig N.

--- s j

p G

g l

t 3

- e' t..

~

4__

. -.. -.. ~

$ $~w m.o ma h

,l S10 RAGE TusE DEPLETED URANiuu RADOCTivE END PLATES Mgcaptactg SHIELD - RtF SOURCE il GA,(.12G 0 4 a " L*1?MM ?"d', '

J (IN STORED POSITION COLD ROLLED STEEL e 1-20 FLAT HD SCREWS (a)

$s8 MT4 4

CAST HANDLE STEEL-CADMlUM PLATED

/(ALUM. All0Y)

  • l0 52 FLAT HD SCREW 5(6)

STEEL.-CADMILM RATED L

i

/

/

i

\\

dD 7

f a

LOCK ASSY wEu

/ -9 Tuse-aEr (SEE M Y 2)

]

(D60C&D ROLLED STEEQ SEE SWT4 EMQ i

(STEEQ 1N//////U//////t'>

3 5

i l

l V

/

/

fy l

n l

^) O @-

1

~ // /

-,. 1 1

\\

ma

/

- 7 1

1 1

- w.

s.

=. -. _:._

/

s

/

r s

ggAL "

TROL COftfCOR- /

/

/

AS6r

/

/

(SEESHT32(3) SASH -

O 8

F

.:: -. 3 s

OMIN 1,, M s

\\

/

/

I M

_/

_ / ll

/ \\'

/

'

  • f/

/

/ //

\\

M-SOURCE '10ENId hO O(,, h

/

N JKL

.m v a e

- y 7 REE 95 BCET C04R.RfvETED

- -N RUG

(.036 STAltt. ST)

~

MF g

/

pECTINGRG5@)

=

\\

CDN rmo M

-YY.,_E

/

1204 STEEL RIGlD STORAGE RUG A66Y sw e,,

ww POLYURETHArtE MOCEL 660 N RAY PROJE@

~

M -@3 7~

FOAM 660 lAoCf g#*8 m

SHimlNG CONTAINER

-,i

_ DESCRIPTIVE ASL"#MBLY JUL2F IMAt. WEIGHT-48 LBS

\\

~,,,iE F " 660s, li

~

emuusa.m enum

i l rm l m

A hNN Set SWT 1 m

)

O c""

wes w ws l

EfvD PLATE-REF.

MFIED m (CORBIN # O2290)

LOCK RETAINE"

' g). 2 S OC. H D (304 STAIN. Sh CAP SCREW (2)

WITH LOCTITE Y

Q

\\

suascum ans f

! g COVER j

M"" T,,,

f (504 Swrt.5TL) urm p

k

\\

SELECTM EXX

/

z (SERYLLUJ COPPER)

/h< ! Q 7A-T

[

COMPRE290N SPRm6 f

s (MUSAC WIRE) s l'

/

_3 2EE SHEET 5

\\

q

$1

$6 d

/

- 3 __ l '

>f

+

i

~

a

_a_.

<gdh M-g 3

_f f

N Y

Po*

C 672 50C HQ CAP SCR.

/

r j

(STAm Sit.) 4 trrH toernt pp;, n my y

mmg_a

/

i s

/

ANT'-Ra^rt toss SELEC1DM RN6 RETAINER

/

(so4 STAW. STL)

(3o4 srAn.sTt) 4 coueRe5Tica smre a

stEc n mns gc as roomw (504 sTAN. STQ myH @

% scwer) m m et>Ces)

LOCK ASSEMBLY SECTION C-C

'M 660 CAMARNPfDJB3tur su, Pens Cmruce 1

  • N,

__Ot3CMPDE AASit Y.__

-=.

__. 1 C.

eeon w

h ytt

'^

Xwm

?

)

(::,/

g 4,wg 800 he trw 5 w g

Wes'wsm DC 70510 W Ond Speckal n wy wua MN C0KPETENT AUTDOEITY CERTIFICATIUH FOR A TYPE B(U)

RADI0 ACTIVE MATERIALS PACKAGE DESICW CIRTIFICATE USA /9033/B(U), REVISICIt 7 This certifies that the radioactive materials package design described below has been certified by regulatory requirements for a Type B(U)the competent authority of the United States as m packaging for radioactive prescribed in the regulatio materigls as the United States of Aretica.gs of the International Atomic Energy Agancy and 1.

Package _ Identification - Amersham Model Nos.

660, 660E, 660A, 660AE, 660B or 660BE.

2.

Packseine Description and Authorized Padioactive contents described in U.S.

Nuclear Regulatory Commission Certificate of as Corpliance No. 9033, Revision 8 (attached).

3.

GENERAL CONDITIONS -

Each user of this certificate shall have in his a.

possession of this certificate and all documents necessary to a copy properly prepare the package for transportation.

The user shall prepare the package for shipment in accordance with the doeur.entation and applicable regulations.

b.

Each user of this certificate, other than the originsi petitioner, shall register his identity in writing to the Radioactive Materials Branch (DEM-23), Office of Easardous Materials Technology, Research and Special Progrars Administration, U.S.

Depa rtment of Transportation, Washington D.C. 20590-0001.

This certificate does not relieve any consignor or c.

carrier from corp 11ance with any requirement of the Government of any country through or into which the package is to be transported.

1 "Saf ety Series No. 6, Regulations for the Safe Transport of Radioactive Materials, 1973 Revised Edition, Atomic Energy Agency (I AEA), vienna, Austria.as ar; ended,' published by the Internatienal 2 Title 49, code of Tederal Regulations, Parts 100 - 199, United S tates of America.

(. 3.)

CERT 3FICATE DEA /9033/B(D), ksv28105 9 i

t*

4.

Merkinc and Labelinc - The package shall bear the. starking USA /9033/B(U) in addition to other required markings and labeling.

5.

Expiration ga_te, - This certificate expires on Cetober te 31, 1995.

This certificate supersedes, of USA /9033/B(U).

in its entirety, all previously issued revisions This certificate is issued in accordance with paragraph 806 of the IAEA pegulations and Section 173.471 of Title 49 of the Code of Federal Regulations, in response to the Decertbe r 5,

1990 petition by Ainersham Corporation, Burlington, MA, and file in this Office.

in consideration of other inforr.ation on-i Certified by 4

mc

!dlM MichM E. Wangler

/

Chief, Radioactive MateriaN[ Branch (DATE)

Of fice of Batardous Materials Technology Revision 7 - Issued to incorporate U.S. Nuclear Regulatory Cocr.ission Certificate of Corpliance No. 9033, Revision 8.

I v

l l

l j

l l}