ML20057B550

From kanterella
Jump to navigation Jump to search
Forwards ISI Ninety-Day Rept,Beaver Valley Power Station, Unit 1 Outage 9 for 1993 from 911209-930613
ML20057B550
Person / Time
Site: Beaver Valley
Issue date: 09/13/1993
From: Sieber J
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20057B551 List:
References
NUDOCS 9309220222
Download: ML20057B550 (1)


Text

,,

4 Beaver Va ey Power Station Shippingport, PA 15077-0004 JOHN D. SIEBER (412) 393-5255 Sensor Vice President and Fax (412) 643-8069 Chief Nuclear Othcer Nuclear Power Division September 13, 1993 U.

S. Nuclear Regulatory Commission i

Attn:

Document Control Desk Washington, DC 20555

[

Subject:

Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 Ninth Refueling Outage Inservice Inspection Report This letter forwards the Inservice Inspection Ninety-Day report on ASME Class 1,

2, and 3

components examined during the' ninth refueling outage at Beaver Valley Unit No.

1.

The ASME Boiler and Pressure Vessel

Code,Section XI, Article IWA-6230 requires that an inservice inspection. report be submitted to 'the enforcement and i

regulatory authority' having jurisdiction-at the plant site within O

ninety days after completion of an inservice inspection.

The recent inservice inspection term at Beaver Valley Unit No. 1 ended on l

June 13, 1993.

l These examinations are part of Interval 2, Period 2 of the Unit No.

1 ISI schedule.

The inservice inspections were performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code, 1983 Edition through Summer 1983 Addenda.

i 1

If you have any questions, please contact Steve Sovick at (412) 393-5211.

Sincerely, Q

Siehe i

Attachment cc:

Mr.

L. W. Rossbach, Sr. Resident Inspector Mr. T. T. Martin, NRC Region I Administrator Mr. G.

E. Edison, Project Manager i>

EECTRK UiluTYof THE YEAR "ihi)f'8*

9309220222 930913 L e-9

[1_ $ YN M)

PDR ADOCK 05000334 A

__ O PDR g

i