REGIO;; y 53 12G 31 pgo.39 August 27,1993 U.S. Nuclear Regulatory Commission, Region V Attn: B.H. Faulkenberry, Regional Administrator 1450 Maria Lane, Suite 210 Walnut Creek, CA 94596 License No. SNM-1227 Docket No. 70-1257
Dear Mr. Faulkenberry:
Subject:
Required Reporting of Effluents Pcr 10 CFR 70.59 As required by 10 CFR 70.59, Siemens Power Corporation (SPC) is reporting discharges of radioactive materials in the effluents from its nuclear fuels fabrication plant on Horn Rapids Road in Richland, Washington. Data from January 1,1993 to July 1,1993 are reported in the attached tables.
Solid effluent materials were shipped directly to U.S. Ecology for disposal and to Allied Technology Group for supercompaction prior to return to SPC. The gaseous effluent stack numbers 50 and 55 from the Solid Waste Uranium Recovery (SWUR) facility are temporarily shut down pending resolution of operationalissues with SWUR unrelated to environmental er.lissions. Stack number 47 at the Ammonia Recovery Facility (ARF) was equipped with a new stack sampler and is included for effluents for May and June.
Very truly yours, 06 Mc/
L. J. Maas, Manager Regulatory Compliance LJM:pm cc:
Robert M. Bernero, Director, NMSS Debra McBaugh, State of Washington Dept. of Health 200161
/h 9309210291 930701 D
PDR ADDCK 07001257 f
I C
PDR d
Siemens Power Corporation
.r
)
Nucioar Drmon - Engmenng and Manufac'unng Facery
' 2101 Hom Rapids Road, PO Box 130 R!chland. WA 99352 0130 Tel: (509) 375 8100 Fax: (509) 375 8402 b.
-~
SOLID EFFLUENT Reporting Period:
January 1,1993 to July 1,1993 Number of Shipments:
5 Mode of Transportation:
Truck Destination:
Allied Technology Group - Richland, WA 3
Volume:
91 m Quantity 0.009 Ci Reporting Period:
January 1,1993 to July 1,1993 Number of Shipments:
2 Mode of Transportation:
Truck Destination:
U.S. Ecology - Richland, WA 3
Volume:
77 m Quantity 0.003 Ci Material to be returned to SPC after compaction Based on 3 wt% enriched uranium t
g 4
9 LIQUID EFFLUENT Reporting Period:
January 1,1993 to July 1,1993 Location:
Sewer Line to City of Richland Concentration Error Estimate LLD Quantity Flow (pCl/mt)
(%)
(pCi/mt)
(Cl)
(m3) 5
< 1.7-7 5
1.4-7
<0.027 1.5x10 0.004 i
l i
Lower Limit of Detection for individual sarnp! s.
Based on measurements of uranium discharges from the lagoon and retention systems as reported on NRC Form 741.
GASEOUS EFFLUENT Reporting Period:
January 1,1993 to July 1,1993 Radionuclide:
3 wt% Enriched Uranium Average Error Estimate Average LLD
- Quantity, Flow Stack onc t on Number
(%)
(pCi/mt)
(pCi a)
(m3) j 3
5.29-15 5
3.1-15 1.76 3.33 + 8 6
4.71-16 5
1.8-15 0.05 1.15 + 8 9
6.60-15 5
2.5-15 0.24 3.70 +7 10 3.04-14 5
3.9-15 0.28 9.15 + 6 21 1.90-15 5
2.9-15 0.26 1.39 + 8 25 1.69-15 5
2.1-15 0.04 2.23 + 7 31 1.33-15 5
2.7-15 0.49 3.65 + 8 32 2.74-14 5
4.9-15 0.81 2.95 + 7 37 1.17-14 5
1.1-15 1,71 1.46 + 8 42 9.63-16 5
1.7-15 0.04 4.71 +7 46 3.85-16 5
2.1-15 0.05 1.25 + 8 47 2.62-15 5
3.1-15 0.01 3.27 + 6 49 4.50-15 5
2.1-15 0.23 5.10+7 50 Stacks Temporarily Shut Down 55 TOTAL 5.97 1.42 + 9 Radionuclide: Mixed Fission and Activation Products (pCi p) 52 1.04-14 5
4.2-14 0.51 4.87+7 Y
TOTAL 0.51 4.87+7 Typical Lower Limit of Detection for 7-day sampling period.
Radionuclide: Based on 3 wt% enriched uranium.
' ** New sampler on Stack 47 for last two months.