I '.

L4 HANDLED BY /NI[ [ --

DATE COPlED //0 DATE SENT _ 9/7-OTHER CERTIFIED MAIL RETURN RECEIPT REQUESTED ARTICLE NUMBER: P 346 404 510 09 E NLR-E93365 Mr. Steve Mathis NJ Department of Environmental Protection and Energy Office of Enforcement Policy Southern Bureau of Water and Hazardous Waste Enforcement 20 East Clementon Road Gibbsboro, NJ 08026

Dear Mr. Mathis:

HOPE CREEK GENERATING STATION NJPDES PERMIT NO. NJ0025411 RETRACTION OF EFFLUENT TEMPERATURE VIOLATION CASE NO.

93-09-04-0550-16 On September 4, 1993, Public Service Electric and Gas Company (PSE&G) reported an exceedance of the daily maximum limit for temperature in the cooling tower blowdown discharge (DSN 461A) at the Hope Creek Generating Station.

The daily maximum permit i

limit is 96*F and the reported temperature value was 96.2*F.

The exceedance, which occurred on September 3, was reported to the NJDEPE Hotline and was issued Case No. 93-09-04-0550-16 by Operator 14.

PSE&G, in making this notification, believes that it was acting in accordance with NJAC 7:14A-3.10, which requires permittees to notify the NJDEPE of violations of daily maximum permit limits.

However, upon review of the effluent temperature data (see attached), PSE&G believes that no violation occurred based upon the guidance provided in the Department's DMR Instruction Manual (Revised February 1993).

In accordance with the Department's rounding off procedure (Page 54), calculated effluent values are l

reported to the same sensitivity as the permit limit.

Therefore, 96.2*F is rounded off to 96*F and no effluent violation occurred.

160013 MM 9309170057 930909

[5

  1. l N

PDR ADOCK 05000354 S

ppg

SEP 091993 S.

Mathis 2

NLR-E93365 If you have any questions or require additional information, please contact Pat McCabe of my staff at (609) 339-1245.

Sincerely, c-l F. X. Thomson, Jr.

j Manager -

Licensing and Regulation Att hment (1) i C

Assistant Director of Enforcement NJ Department of Environmental Protection and Energy 401 East State Street CN 029-Trenton, NJ 08625-0029 l

o

-U.

S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.

20555 4

t Y

l

[

i 6

9

. s..

}

SEP 0 91993

  • S. Math s 3

NLR-365 jd BC General Manager - Hope Creek Operations (H07) j General Manager - Environmental Affairs (Newark 17G)

Chemistry Manager - Hope Creek (H05)

~ (N21)

Principal Engineer - Environmental Licensing Station Environmental Licensing Engineer - Hope Creek (N21) i G. M. Suey (H15)

C. E. White (H15) l P. R.

LaSala-(H15)

Microfilm Records Management File 2.1.1 HC Chron File 11.2 i

i ATS CLOS: DEP PM NJ0025411-06 TASK 0021 F

l s

h l

l l

f

' I i

HOPE CREEK GENERATING STATION NJPDES PERMIT NUMBER.NJ0025411 TEMPERATURE DATA FOR SEPTEMBER 3, 1993 INFLUENT EFFLUENT DELTA TIME TEMP.

TEMP.

TEMP.

l 0100 84.0 95.9 11.9 l

0200 83.9 96.5 12.6 0300 83.7 96.7 13.0 0400 84.2 96.4 12.2 0500 84.1 95.7 11.6 0600 83.4 95.5 12.1 0700 83.1 95.4 12.3 0800 82.5 95.1-12.6:

. i 0900 82.3 95.4 13.1 1000 84.0 95.6-11.6 1100 83.9 96.5 12.6 1200 83.7 96.9 13.2 i

1300 83.6 97.1' 13.5' 1400 84.0 96.4-12.4 1500 84.3 97.3 13.0 1600 85.7 97.9-12.2 1700 84.9 97.8 12.9 l

1800 84.8 97.9

-13.1

)

1900 84.6 97.6 13.0 2000 84.1 96.8 12.7

)

2100 84.1 95.8 11.7 2200 85.0 95.2 10.2' 2300 85.0-93.8 8.8 2400 84.7 92.9 8.2

SUMMARY

MINIMUM AVERAGE MAXIMUM INFLUENT TEMPERATURE 82.30 84.07 85.70 EFFLUENT TEMPERATURE 92.90 96.17 97.90 DELTA TEMPERATURE 8.20 12.10 13.50 Notes:

All data reported in degrees Fahrenheit.

The Daily Maximum Temperature Limit is the highest

. daily averaae temperature value reported'for the monitoring period.

At Hope Creek, the daily maximum temperature limit is 96*F (35.6*C).