September 7, 1993 Docket Nos. 50-321 and 50-366 Mr. J. T. Beckham, Jr.

Vice President - Plant Hatch Georgia Power Company P. O. Box 1295 Birmingham, Alabama 35201

Dear Mr. Beckham:

SUBJECT:

EDWIN I. HATCH, UNITS 1 AND 2 - RESPONSE TO NRC BULLETIN 93-02,

" DEBRIS PLUGGING OF EMERGENCY CORE COOLING SUCTION STRAINERS" (TAC N0s. M86569 and M86570)

This letter acknowledges receipt of your response transmitted by letter dated May 25, 1993, to NRC Bulletin 93-02 (Bulletin). The Bulletin was issued May 11, 1993, to all nuclear power reactor licensees.

It requested licensees to identify fibrous material in the primary containment, take any necessary compensatory measures, and remove any such material.

Your letter stated that during the recent Unit I refueling outage in the spring of 1993, filters were not installed on the drywell cooling units.

Unit 2 recently underwent a fuel inspection c :tage in the spring of 1993.

Records indicate that filters were not installed on the cooling units during this outage. However, during the Unit 2 refueling outage in the fall of 1992, filters were installed on the drywell cooling units. The maintenance work order that documented installation of these filters also documented removal of the filters on October 28, 1997, prior to the drywell closure.

Based on our review of your submittal, we consider your actions to be complete.

Please retain any records of your actions in response to this Bulletin, as subsequent inspection activities may be conducted in regard to this issue.

This completes our action on TAC Nos. M86569 and M86570.

Should you have any questions, please contact me at (301) 504-1496.

Sincerel,

Kahtan N. Jabbour, Project Manager Project Directorate 11-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc:

see next page DISTRIBUTION:

Docket File-S. Varga L. Berry ACRS (10)

NRC & Local PDRs G. Lainas K. Jabbour E. Herschoff, RII PDII-3 R/F

,/, D. Matthews OGC J. Hickman Ltd

'Lf $

SCSpf,hj

%V D:

hT R. Barrett LA:PDIl PM:PDI -3 PDII-3J-LBer y) 3 KJabbour/rt JStaref s RBarMtt Hickmin DM hews k/C/93 9 / 01/93 O/ci/93 7/ot/93 9/3 /93 9/ /93 l

0FFICIAL RECORD COPY

}

DOCUMENT NAME: G:\\ HATCH \\B93-02.2 9309150285 930907 i

[ * **~ D O M Mf

'I b, sh-

"G PDR ADOCK 0500c321 Q

PDR i

o s

ik PIOD g

E UNITED STATES j, iZ;f f !

4 NUCLEAR REGULATORY COMMISSION

^

g WASHINGTON D C. 205554c01 g

tu September 7, 1993 Docket Nos. 50-321 and 50-366 Mr. J. T. Beckham, Jr.

Vice President - Plant Hatch Georgia Power Company P. O. Box 1295 Birmingham, Alabama 35201

Dear Mr. Beckham:

SUBJECT:

EDWIN 1. HATCH, UNITS I AND 2 - RESPONSE TO NRC BULLETIN 93-02,

" DEBRIS PLUGGING OF EMERGENCY CORE COOLING SUCTION STRAINERS" (TAC N0s. M86569 and M86570)

This letter acknowledges receipt of your response transmitted by letter dated May ES, 1993, to NRC Bulletin 93-02 (Bulletin). The Bulletin was issued May 11, 1993, to all nuclear power reactor licensees.

It requested licensees to identify fibrous material in the primary containment, take any necessary compensatory measures, and remove any such material.

Your letter stated that during the recent Unit I refueling outage in the spring of 1993, filters were not installed on the drywell cooling units.

Unit 2 recently underwent a fuel inspection outage in the spring of 1993.

Records indicate that filters were not installed on the cooling units during this outage.

However, during the Unit 2 refueling outage in the fall of 1992, filters were installed on the drywell cooling units. The maintenance work order that documented installation of these filters also documented removal of the filters on October 28, 1992, prior to the drywell closure.

Based on our review of your submittal, we consider your actions to be complete.

Please retain any records of your actions in response to this Bulletin, as subsequent inspecticn activities may be conducted in regard to this issue.

This completes our action on TAC Nos. M86569 and M86570. Should you have any questions, please contact me at (301) 504-1496.

Sincerely, b b b bl. b Kahtan N. Jabbour, Project Manager Project Directorate II-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation I

cc:

see next page

1 Mr. J. T. Beckham, Jr.

Georgia Power Company Edwin I. Hatch Nuclear Plant cc:

Mr. Ernest L. Blake, Jr.

Mr. Alan R. Herdt, Chief Shaw, Pittman, Potts and Trowbridge Project Branch #3 2300 N Street, NW.

U. S. Nuclear Regulatory Commission Washington, DC 20037 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. S. J. Bethay Manager Licensing - Hatch Mr. Dan H. Smith, Vice President Georgia Power Company Power Supply Operations P. O. Box 1295 Oglethorpe Power Corporation Birmingham, Alabama 35201 2100 East Exchaiege Place Tucker, Georgia 30085-1349 Mr. L. Sumner General Manager, Nuclear Plant Charles A. Patrizia, Esquire Georgia Power Company Paul, Hastings Janofsky & Walker Route 1, Box 439 12th Floor Baxley, Georgia 31513 1050 Connecticut Avenue, NW.

Washing'.on, DC 20036 Resident Inspector U.S. Nuclear Regulatory Commission Mr. Jack D. Woodard Route 1, Box 725 Senior Vice President -

Baxley, Georgia 31513 Nuclear Operations Georgia Power Company Regional Administrator, Region Il P. O. Box 1295 U.S. Nuclear Regulatory Commission Birmingham, Alabama 35201 101 Marietta Street, NW. Suite 2900 Atlanta, Georgia 30323 Chairman i

Appling County Commissioners Mr. Charles H. Badger County Courthouse Office of Planning and Budget Baxley, Georgia 31513 Room 610 270 Washington Street, SW.

Atlanta, Georgia 30334 Harold Reheir, Director Department of Natural Resources 205 Butler Street, SE., Suite 1252 Atlanta, Georgia 30334 4

l

\\

J