ML20057A392

From kanterella
Jump to navigation Jump to search
Notification of 930929 Meeting W/Util to Discuss Proposed Approach for Roll Type Repairs on Pressurized Heater Penetrations for Plant
ML20057A392
Person / Time
Site: Calvert Cliffs  
Issue date: 09/02/1993
From: Mcdonald D
Office of Nuclear Reactor Regulation
To: Capra R
Office of Nuclear Reactor Regulation
References
NUDOCS 9309140140
Download: ML20057A392 (4)


Text

.

I 1

UNITED STATES

[

j NUCLEAR REGULATORY COMMISSION s

W ASHINGTON, D.C. 20556-0001 September 2, 1993 l

Docket Nos. 50-317 l

and 50-318 MEMORANDUM FOR: Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation FROM:

Daniel G. Mcdonald, Senior Project Manager Project Directorate I-l Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation i

l

SUBJECT:

FORTHCOMING MEETING WITH BALTIM0RE GAS AND ELECTRIC COMPANY (BG&E)

DATE & TIME:

Wednesday, September 29, 1993 10:00 a.m. to 11:00 a.m.

\\

LOCATION:

One White Flint North t

11555 Rockville Pike Rockville, Maryland i

Room 13 B 9 l

PURPOSE:

To discuss proposed approach for Roll Type Repairs on I

pressurizer heater penetrations, Calvert Cliffs Nuclear Power Plant, Unit Nos. I and 2.

\\

PARTICIPANTS *:

NRC ILG.1E j

G D. Mcdonald G. Tesfaye R. Capra B. Rudell R. Hermann J. Richards W. Koo J. Calle et. al et. al.

a Daniel G. Mcdonald, Senior Project' Manager i

9309140140 930902 Project Directorate I-I l

PDR ADOCK 05000317 P

PDR Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc: See next page

  • Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement of NRC Staff Policy," 43 Federal Reaister 28058,6/28/78.

{0 NRC RLE CENTER COPY l

i

QlS.TRIBUT10N - Routine Meetina Notice i

Docket File J

NP.C & Local PDRs PDI-l Reading T. Murley/F. Miraglia,12/G/18 J. Partlow, 12/G/18 l

S. Varga J. Calvo 3

R. A. Capra D. Mcdonald C. Vogan A. Chaffee, OEAB, 11/A/l OGC 1

E. Jordan, MNBB 3701 E. Rossi, 9/A/2 Receptionist (0WFN)

R. Hermann, 7/0/4 W. Koo, 7/D/4 i

ACRS (10)

OPA i

NRR Mailroom, PMAS,12/G/18 i

P. O' Dell, PMAS

)

G. Zech, RPEB, 10/A/19 V. McCree, EDO, 17/G/21 C. Cowgill, Region I K. Abraham /D. Screnci, Region I 1

i l

l l

Mr. Robert E. Denton Calvert Cliffs Nuclear Power Plant i

Baltimore Gas & Electric Company Unit Nos. I and 2 CC:

Mr. Michael Moore, President Mr. Joseph H. Walter Calvert County Board of Engineering Division Commissioners Public Service Commission of 175 Main Street Maryland Prince Frederick, Maryland 20678 American Building i

231 E. Baltimore Street 1

D. A. Brune, Esquire Baltimore, Maryland 21202-3486 General Counsel Baltimore Gas and Electric Company Kristen A. Burger, Esquire l

P. O. Box 1475 Maryland People's Counsel Baltimore, Maryland 21203 American Building, 9th Floor 231 E. Baltimore Street Jay E. Silberg, Esquire Baltimore, Maryland 21202 Shaw, Pittman, Potts and Trowbridge 2300 N Street, NW Patricia T. Birnia, Esquire Washington, DC 20037 Co-Director Maryland Safe Energy Coalition Mr. G. L. Uetter, Director, NRM P. O. Box 33111 Calvert Cliffs Nuclear Fower Plant Baltimore, Maryland 21218 1650 Calvert Cliffs Parkway Lusby, Garyland 20657-47027 j

Resident Inspector c/o U.S. Nuclear Regulatory l

Commission P. O. Box 287 St. Leonard, Maryland 20685 i

Mr. Richard I. McLean Administrator - Radioecology Department of Natural Resources 580 Taylor Avenue Tawes State Office Building B3 Annapolis, Maryland 21401 Regional Administrator, Region I U.S. Nuclear Regulatory Commission l

475 Allendale Road King of Prussia, Pennsylvania 19406 l.

l m

,.,. r 7-

..m--.-

.m.-

..-,w-

-s w.,

_=

i Docket Nos. 50-317 September 2,1993 and 50-318 1

MEMORANDUM FOR:

Robert A. Capra, Director Project Directorate I-l l

Division of Reactor Projects I/II Office of Nuclear Reactor Regulation FROM:

Daniel G. Mcdonald, Senior Project Manager r

Project Directorate I-l Division of Reactor Projects - I/II l

Office of Nuclear Reactor Regulation l

SUBJECT:

FORTHCOMING MElilNG WITH BALTIMORE GAS AND ELECTRIC COMPANY (BGLE).

i DATE & TIME:

Wednesday, September 29, 1993 10:00 a.m. to 11:00 a.m.

LOCATION:

One White Flint North 11555 Rockville Pike Rockville, Maryland Room 13 B 9 PURPOSE:

To discuss proposed approach for Roll Type Repairs on f

pressurizer heater penetrations, Calvert Cliffs Nuclear Power i

l Plant, Unit Nos. I and 2.

{

t PARTICIPANTS *:

NRC EG&E l

G D. Mcdonald G. Tesfaye R. Capra B. Rudell R. Hermann J. Richards W. Koo J. Calle et. al et. al.

Original signed by:

Daniel G. Mcdonald, Senior Project Manager i

Project Directorate I-2 l

Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation l

cc: See next page

  • Meetings between NRC technical staff and applicants or licensees are open for i

interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement of NRC Staff l

Policy," 43 Federal Reoister 28058, 6/28/78.

i OFFICE PDI-1:LA' PDI-1:M PDI-1:D N

CVogan M)

DMcDonald: avl RACapra I rf /5!,/93 e1/en/93

[J 9/Dk93

/ /

/ /

)

out 0FFICIAL RECORD COPY

~'

l FILENAME: CC50317.MTR j

-l I