Forwards Application for Amend to License DPR-59,requesting Extension to Surveillance Interval for Turbine Control Valve Fast Closure Pressure Switch
ML20056F561
Person / Time
Site: FitzPatrick 
Issue date: 08/26/1993
From: Ralph Beedle
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20056F562 List:
References
JPN-93-061, JPN-93-61, NUDOCS 9308300076
Download: ML20056F561 (2)


Text

_

i 123 Man E.treet Wheo P;an Ww York 1DM1 914Mi fSid A NewYo.rkPower 4r# Authonty exece-e vee e,es eemi Nudear Generason August 26,1993 JPN-93-061 U.S. Nuclear Regulatory commission ATTN: Document Control Desk Mail Station P1-137 Washington, D.C. 20555 i

SUBJECT:

James A. FitzPatrick Nuclear Power Plant l

Docket No. 50-333 Proposed Change to the Technical Specifications One-time Extension to the Surveillance interval for Turbine Control Valve Fast Closure Oil Pressure Trio (JPTS-93-019)

Dear Sir,

f This application for an amendment to the James A. FitzPatrick Technical Specifications requests an extension to the surveillance interval for calibrating the pressure switches which sense main turbino control _ valve fast closure. The Authority is requesting an extension for this surveillance interval requirement until the fall maintenance outage, currently scheduled to start on October 23,1993. The fall maintenance outage was recently rescheduled in order to obtain lower cost replacement power for Authority customers.

The eighteen month surveillance interval with the 25% extension allowed by Technical Specification 4.0.B.1 expires on October 18,1993. The proposed amendment is required in order to allow calibration of the pressure switches during the 1993 fall maintenance outage. Although it is possible to perform this calibration while the plant is on line, it is not practical to do so. The technicians performing the calibration and the verification would be subjected to a significant radiation dose. In addition, performing this surveillance on line increases the likelihood of an inadvertent reactor scram while the pressure switches are being calibrated or from perturbing the main turbine electro-hydraulic control (EHC) system.

The Authority requests that the application for this amendment be granted by October 15,1993 since the surveillance interval including the 25% extension will expire shortly thereafter.

]

The signed original of the Application for Amendment to Operating License is enclosed for filing. Attachments I and 11 to this application contain the proposed change i

to the Technical Specifications and the associated Safety Evaluation.

9"/OG$.

9308300076 930826 n@s I

PDR ADOCM 05000333 N

P PDR I

i

(

I l

i

4 A copy of this application and the associated attachments are being provided to the designated New York State official in accordance with 10 CFR 50.91.

if you have any questions, please contact J. A. Gray, Jr.

Very truly yours.

/

('

) x

-c Ralph E. Beedle att:

as stated cc:

U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Office of Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 136 Lycoming, NY 13093 Mr. Brian McCabe Project Directorate 1-1 Division of reactor Projects - 1/II U.S. Nuclear Regulatory Commission Mail Stop 14 B2 Washington, DC 20555 Ms. Donna Ross New York State Energy Office i